Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluating Domestic Hot Water Distribution System Options with Validated Analysis Models

A developing body of work is forming that collects data on domestic hot water consumption, water use behaviors, and energy efficiency of various distribution systems. Transient System Simulation Tool (TRNSYS) is a full distribution system developed that has been validated using field monitoring data and then exercised in a number of climates to understand climate impact on performance. In this study, the Building America team built upon previous analysis modeling work to evaluate differing distribution systems and the sensitivities of water heating energy and water use efficiency to variations of climate, load, distribution type, insulation and compact plumbing practices. Overall, 124 different TRNSYS models were simulated. The results of this work are useful in informing future development of water heating best practices guides as well as more accurate (and simulation time efficient) distribution models for annual whole house simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System analysis for the Huntsville Operational Support Center distributed computer system

The Huntsville Operations Support Center (HOSC) is a distributed computer system used to provide real time data acquisition, analysis and display during NASA space missions and to perform simulation and study activities during non-mission times. The primary purpose is to provide a HOSC system simulation model that is used to investigate the effects of various HOSC system configurations. Such a model would be valuable in planning the future growth of HOSC and in ascertaining the effects of data rate variations, update table broadcasting and smart display terminal data requirements on the HOSC HYPERchannel network system. A simulation model was developed in PASCAL and results of the simulation model for various system configuraions were obtained. A tutorial of the model is presented and the results of simulation runs are presented. Some very high data rate situations were simulated to observe the effects of the HYPERchannel switch over from contention to priority mode under high channel loading.

Ingels, F. M.↗

Science opportunities from the Topex/Poseidon mission

The U.S. National Aeronautics and Space Administration (NASA) and the French Centre National d'Etudes Spatiales (CNES) propose to conduct a Topex/Poseidon Mission for studying the global ocean circulation from space. The mission will use the techniques of satellite altimetry to make precise and accurate measurements of sea level for several years. The measurements will then be used by Principal Investigators (selected by NASA and CNES) and by the wider oceanographic community working closely with large international programs for observing the Earth, on studies leading to an improved understanding of global ocean dynamics and the interaction of the ocean with other processes influencing life on Earth. The major elements of the mission include a satellite carrrying an altimetric system for measuring the height of the satellite above the sea surface; a precision orbit determination system for referring the altimetric measurements to geodetic coordinates; a data analysis and distribution system for processing the satellite data, verifying their accuracy, and making them available to the scientific community; and a principal investigator program for scientific studies based on the satellite observations. This document describes the satellite, its sensors, its orbit, the data analysis system, and plans for verifying and distributing the data. It then discusses the expected accuracy of the satellite's measurements and their usefulness to oceanographic, geophysical, and other scientific studies. Finally, it outlines the relationship of the Topex/Poseidon mission to other large programs, including the World Climate Research Program, the U.S. Navy's Remote Ocean Sensing System satellite program and the European Space Agency's ERS-1 satellite program.

Stewart, R.↗

DERHCAT (Distributed Energy Resource Hosting Capacity Analysis Tool) [SWR-16-32]

NREL's advanced hosting capacity analysis and System Analysis Reports can help utilities, policymakers, and solar developers better understand the impact of adding new distributed photovoltaic (DPV) systems to the electrical distribution system. Advanced hosting capacity analysis considers the thresholds at which new DPV systems will trigger upgrades or changes to the electrical distribution system and evaluates the cost of different options for expanding the hosting capacity. It is one part of NREL's work to help stakeholders better understand the distribution system costs associated with integrating new DPV systems at different penetration levels. NREL's analysis uses a bottom-up methodology that involves simulating distribution systems. The analysis considers sequential increases in hosting capacity and corresponding upgrade costs from a baseline scenario with no DPV up to penetration levels greater than 100% of peak load.

Ding, Fei↗

Simulation and analysis of an intermediate frequency (IF) distribution system with applications for Space Station

Simulation and analysis results are described for a wideband fiber optic intermediate frequency distribution channel for a frequency division multiple access (FDMA) system where antenna equipment is remotely located from the signal processing equipment. The fiber optic distribution channel accommodates multiple signals received from a single antenna with differing power levels. Performance parameters addressed are intermodulation degradations, laser noise, and adjacent channel interference, as they impact the overall system design. Simulation results showed that the laser diode modulation level can be allowed to reach 100 percent without considerable degradation. The laser noise must be controlled as to provide a noise floor of less than -90 dBW/Hz. The fiber optic link increases the degradation due to power imbalance yet diminishes the effects of the transmit amplifier nonlinearity. Overall, optimal operation conditions can be found to yield a degradation level of about .1 dB caused by the fiber optic link.

Costello, Thomas A.↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗

Cost and Efficiency Analysis for Hybrid AC/DC Distribution System Planning with PV and Battery

Distribution system planning is one of the main tasks for the electric utilities. Cost and energy efficiency are two main concerns in the distribution planning process. In this work, cost and efficiency analyses are conducted for the hybrid AC and DC distribution grids for the planning purposes. The IEEE 34-bus feeder has been applied for the case studies. The investment cost, operation and maintenance cost, replacement cost, etc., have been considered in the life cycle cost analysis. Power losses of both the AC and DC section are calculated with an open source simulation tool, the Open Distribution Simulator Software (OpenDSS). The proposed framework can be applied to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and help comparing different planning options.

AC/DC hybrid system planning↗

System analysis for the Huntsville Operational Support Center distributed computer system

A simulation model was developed and programmed in three languages BASIC, PASCAL, and SLAM. Two of the programs are included in this report, the BASIC and the PASCAL language programs. SLAM is not supported by NASA/MSFC facilities and hence was not included. The statistical comparison of simulations of the same HOSC system configurations are in good agreement and are in agreement with the operational statistics of HOSC that were obtained. Three variations of the most recent HOSC configuration was run and some conclusions drawn as to the system performance under these variations.

Ingels, E. M.↗

On the Path to SunShot - Emerging Issues and Challenges with Integrating High Levels of Solar into the Distribution System

Wide use of advanced inverters could double the electricity-distribution system’s hosting capacity for distributed PV at low costs—from about 170 GW to 350 GW (see Palmintier et al. 2016). At the distribution system level, increased variable generation due to high penetrations of distributed PV (typically rooftop and smaller ground-mounted systems) could challenge the management of distribution voltage, potentially increase wear and tear on electromechanical utility equipment, and complicate the configuration of circuit-breakers and other protection systems—all of which could increase costs, limit further PV deployment, or both. However, improved analysis of distribution system hosting capacity—the amount of distributed PV that can be interconnected without changing the existing infrastructure or prematurely wearing out equipment—has overturned previous rule-of-thumb assumptions such as the idea that distributed PV penetrations higher than 15% require detailed impact studies. For example, new analysis suggests that the hosting capacity for distributed PV could rise from approximately 170 GW using traditional inverters to about 350 GW with the use of advanced inverters for voltage management, and it could be even higher using accessible and low-cost strategies such as careful siting of PV systems within a distribution feeder and additional minor changes in distribution operations. Also critical to facilitating distributed PV deployment is the improvement of interconnection processes, associated standards and codes, and compensation mechanisms so they embrace PV’s contributions to system-wide operations. Ultimately SunShot-level PV deployment will require unprecedented coordination of the historically separate distribution and transmission systems along with incorporation of energy storage and “virtual storage,” which exploits improved management of electric vehicle charging, building energy systems, and other large loads. Additional analysis and innovation are neede

14 SOLAR ENERGY↗

Power-traffic coordinated operation for bi-peak shaving and bi-ramp smoothing – A hierarchical data-driven approach

The power distribution system and urban transportation system are two networked system bare their own operation constraints, such peak load in power systems and traffic congestion in transportation system. With the increasing number of electrical vehicles and charging/discharging stations, two systems are become tightly coupled. However, to optimize the two systems target using electrical vehicles as decision control variables cannot be easily solved using a uniformed optimization frame work. Thus we propose a hierarchical optimization approach to address this problem, which consists of a higher and a lower level. In the higher level, the power distribution system and urban transportation system are treated together to minimize the social cost. Meanwhile, the electrical vehicles and the charging/discharging stations are treated as customers to minimize their own expenditures. Then, an equilibrium is designed to determine the optimal charging/discharging price. In the lower level, the models of power distribution system and urban transportation system are developed to provide a detailed analysis. Specifically, in power distribution system, the three-phase unbalanced optimal power flow problem is relaxed with the semidefinite relaxation programming, and solved with alternating direction method of multiplier. A dynamic user equilibrium problem is formulated for the urban transportation system. For electrical vehicles, the state of charge is considered to optimize the charging/discharging schedule and reduce the impacts of power distribution systems. We conducted the simulation and numerical analysis using the IEEE 8500-bus distribution system and the Sioux Falls system with about 10,000 cars. The results demonstrate the feasibility and effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Criticality Analysis of a Water Distribution System Considering Both Economic Consequences and Hydraulic Loss Using Modern Portfolio Theory

This study introduces an approach using Modern Portfolio Theory (MPT) to consider hydraulic resilience and economic consequence resilience of a water distribution system (WDS) to identify critical assets. ECLIPS (Economic Consequence Linked to Interruption in Providing Service), a way to represent loss of water provision as economic loss, is used to measure economic consequence following a reduction of WDS functionality. The approach is demonstrated using a hypothetical WDS and tested for pipe breakage and replacement scenarios using EPANET hydraulic simulations. First, the correlation between hydraulic resilience and economic consequence resilience was investigated to assess differences between two resilience measures for identifying pipe’s criticality for replacement. The results confirmed the two resilience measures exhibited differing responses (covariance = 0.2), suggesting that use of both would provide complementary insight. Results of the MPT analysis identified the benefits of balancing hydraulic and economic consequence resilience measures to yield lower risk. This study provides a practical approach to incorporate economic consequence into planning, design, and research applications identifying critical WDS assets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community Energy: Analysis of Hydrogen Distributed Energy Systems with Photovoltaics for Load Leveling and Vehicle Refueling

Energy storage could complement PV electricity generation at the community level. Because PV generation is intermittent, strategies must be implemented to integrate it into the electricity system. Hydrogen and fuel cell technologies offer possible PV integration strategies, including the community-level approaches analyzed in this report: (1) using hydrogen production, storage, and reconversion to electricity to level PV generation and grid loads (reconversion scenario); (2) using hydrogen production and storage to capture peak PV generation and refuel hydrogen fuel cell electric vehicles (FCEVs) (hydrogen fueling scenario); and (3) a comparison scenario using a battery system to store electricity for EV nighttime charging (electric charging scenario).

08 HYDROGEN↗

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of different data averaging times on statistical analysis of distributed domestic photovoltaic systems

The trend of increasing application of distributed generation with solar photovoltaics (PV-DG) suggests that a widespread integration in existing low-voltage (LV) grids is possible in the future. With massive integration in LV grids, a major concern is the possible negative impacts of excess power injection from on-site generation. For power-flow simulations of such grid impacts, an important consideration is the time resolution of demand and generation data. This paper investigates the impact of time averaging on high-resolution data series of domestic electricity demand and PV-DG output and on voltages in a simulated LV grid. Effects of 10-minutely and hourly averaging on descriptive statistics and duration curves were determined. Although time averaging has a considerable impact on statistical properties of the demand in individual households, the impact is smaller on aggregate demand, already smoothed from random coincidence, and on PV-DG output. Consequently, the statistical distribution of simulated grid voltages was also robust against time averaging. The overall judgement is that statistical investigation of voltage variations in the presence of PV-DG does not require higher resolution than hourly. (author)

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-stage State Estimation Algorithm for Distribution Network Analysis

Practical distribution system contains many nodes and short branches. As a result, a more efficient and stable distribution state estimation (DSE) algorithm is needed to properly handle the inverse operation of its large-scale ill-conditioned information matrix. This paper proposed a two-stage DSE algorithm to transform the inverse operation into addition and multiplication operations in a recursive manner. It includes pseudo measurement preprocessing in the offline stage where an approximate linear estimator is adopted to relieve most of computation burdens, and real-time correction in the online stage where a nonlinear estimator is used to update the estimation. Numerical results of the method applied to both IEEE standard test systems and an actual distribution system show the accuracy and effectiveness of the proposed algorithm.

Dong, Jiaojiao↗

Interconnection, Integration, and Interactive Impact Analysis of Microgrids and Distribution Systems

Distribution management systems (DMSs) are increasingly used by distribution system operators (DSOs) to manage the distribution grid and to monitor the status of both power imported from the transmission grid and power generated locally by a distributed energy resource (DER), to ensure that power flows and voltages along the feeders are maintained within designed limits and that appropriate measures are taken to guarantee service continuity and energy security. When microgrids are deployed and interconnected to the distribution grids, they will have an impact on the operation of the distribution grid. The challenge is to design this interconnection in such a way that it enhances the reliability and security of the distribution grid and the loads embedded in the microgrid, while providing economic benefits to all stakeholders, including the microgrid owner and operator and the distribution system operator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surveillance and Datalink Communication Performance Analysis for Distributed Separation Assurance System Architectures

This study investigates the effects of two technical enablers: Automatic Dependent Surveillance - Broadcast (ADS-B) and digital datalink communication, of the Federal Aviation Administration s Next Generation Air Transportation System (NextGen) under two separation assurance (SA) system architectures: ground-based SA and airborne SA, on overall separation assurance performance. Datalink performance such as successful reception probability in both surveillance and communication messages, and surveillance accuracy are examined in various operational conditions. Required SA performance is evaluated as a function of subsystem performance, using availability, continuity, and integrity metrics to establish overall required separation assurance performance, under normal and off-nominal conditions.

Chung, William W.↗