At least 91 records · Page 5

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Semi-Supervised Learning with Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Semi-Supervised Learning With Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Graph Convolutional Network for Active Distribution System Anomaly Detection Considering Measurement Spatial-Temporal Correlations

The accuracy of distribution system state estimation may be significantly impacted by the existence of bad measure-ments and unexpected topology errors. This paper proposes a data-driven Graph Convolutional Network (GCN) for anomaly detection, including bad measurements and topology change events. Compared to many existing machine learning approaches, the proposed approach embeds both spatial-temporal measure-ment correlations, which allows us to detect and distinguish different anomalies. Numerical results carried out on the IEEE 37-node system demonstrate that the proposed-based method can obtain high accuracy in detecting bad data and topology changes as compared to other approaches, even in the presence of high PV penetrations.

active distribution system↗

Composition, Emissions, and Air Quality Impacts of Hazardous Air Pollutants in Unburned Natural Gas from Residential Stoves in California

The presence of hazardous air pollutants (HAPs) entrained in end-use natural gas (NG) is an understudied source of human health risks. We performed trace gas analyses on 185 unburned NG samples collected from 159 unique residential NG stoves across seven geographic regions in California. Our analyses commonly detected 12 HAPs with significant variability across region and gas utility. Mean regional benzene, toluene, ethylbenzene, and total xylenes (BTEX) concentrations in end-use NG ranged from 1.6–25 ppmv–benzene alone was detected in 99% of samples, and mean concentrations ranged from 0.7–12 ppmv (max: 66 ppmv). By applying previously reported NG and methane emission rates throughout California’s transmission, storage, and distribution systems, we estimated statewide benzene emissions of 4,200 (95% CI: 1,800–9,700) kg yr –1 that are currently not included in any statewide inventories–equal to the annual benzene emissions from nearly 60,000 light-duty gasoline vehicles. Additionally, we found that NG leakage from stoves and ovens while not in use can result in indoor benzene concentrations that can exceed the California Office of Environmental Health Hazard Assessment 8-h Reference Exposure Level of 0.94 ppbv–benzene concentrations comparable to environmental tobacco smoke. This study supports the need to further improve our understanding of leaked downstream NG as a source of health risk.

42 ENGINEERING↗

Distribution System Behind-the-Meter DERs: Estimation, Uncertainty Quantification, and Control

This paper summarizes the three-year technical activities of the IEEE Task Force (TF) on behind-the-meter (BTM) distributed energy resources (DERs): estimation, uncertainty quantification, and control. The potential grid services from BTM DERs are discussed in detail. The paper also reviews the state-of-the-art for BTM DERs visibility, uncertainty quantification, and, optimization and control. Furthermore, different aspects of the market structures associated with BTM DERs are covered, including emerging market and business models. Finally, needs and recommendations are provided for additional areas such as system protection, computing capabilities, algorithm development, market structure design, cyberinfrastructure and security, and hardware and software developments.

behind-the-meter↗

DSO+T: Valuation Methodology and Economic Metrics (DSO+T Study: Volume 4)

This report summarizes a rigorous valuation analysis methodology used by the Distribution System Operator with Transactive (DSO+T) study to estimate the financial benefits and costs of adopting Transactive Energy coordination of distributed energy resources for key stakeholders (for example distribution system operators and customers). This was achieved by modeling the value exchanges between stakeholders and determining the annualized costs and revenues experienced by stakeholders, enabling the evaluation of overall impact on stakeholder’s annualized cash flow. Extensive work was conducted developing methods to estimate the operating costs of distribution system operators at a level of granularity that would allow the financial impact of implementing a transactive energy approach to be estimated. This work included developing parametric models for labor and software costs, distribution system capital and maintenance costs, growth rates, and factors to determine annualized costs of capital investments. Simulation results were used to calculate wholesale energy costs and revenues from retail sales. Valuation analysis methods were also developed for other stakeholders including customers, the transmission system operator, independent system operator, and generators. The resulting capability allows a complete mapping of the flow of financial value between stakeholders that can be directly integrated with the results of demand flexibility simulations. Example results are provided for a business-as-usual case and compared to a transactive energy case as well as to actual cost data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Scaled Implementation of Smart Charge Management for Electric Vehicles

Smart charge management (SCM) has become a critical strategy for mitigating potential grid impacts and reducing electricity costs for all customers. This study will evaluate the economics of implementing light-duty EV SCM at scale across the United States. This work will enhance distribution system analysis by estimating SCM implementation costs, exploring viable business cases, and developing a framework for national-level applications. The primary methodology involves leveraging detailed grid modeling from a specific service territory and using spatial extrapolation techniques to generalize findings to other regions. The analysis will develop key metrics to quantify the costs and benefits of SCM, including implementation costs relative to strategy and scale, the cost of distribution system upgrades with and without SCM, and the percentage of peak-load reduction. The objective is to produce a comprehensive report and a parameterized framework that enables utilities to self-assess the value of SCM in their own service territories. This will support the development of cost-effective charging strategies, accelerate the energization of new EV chargers, and facilitate the seamless integration of EVs into the nation's power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY↗

PV Hosting Capacity Estimation: Experiences with Scalable Framework; Preprint

Hosting capacity is an indication of the amount of photovoltaics (PV) can be hosted in a distribution system. This paper presents a framework for estimating distributed PV hosting capacity at scale. We first analyze the key challenges of performing relevant large scale simulation including computational and modeling challenges. Then, we develop two python-based software tools in order to conduct repeatable distribution analyses: Distribution Integration Solution Cost Options (DISCO) for configuring and analyzing simulations, and JADE for parallelizing jobs on HPC clusters. A case study of hosting capacity estimation for SMART-DS SFO 2000+ synthetic feeders is used to demonstrate the capability of the developed framework and tools. The framework and tools can help utilities assess the overall hosting capacity of their service territory, through which the overall upgrade cost can be better planned in order to integrate more PV in the future.

distributed energy resources↗

Generalized Analytical Estimation of Sensitivity Matrices in Unbalanced Distribution Networks

Fast and accurate estimation of sensitivity matrices is significant for the enhancement of distribution system modeling and automation. Analytical estimations have mainly focused on voltage magnitude sensitivity to active/reactive power injections for unbalanced networks with Wye-connected loads and neglecting DERs' smart inverter functionality. Hence, this paper enhances the scope of analytical estimation of sensitivity matrices for unbalanced networks with 1- Φ, 2- Φ, and 3- Φ Delta/Wye-connected loads, DERs with smart inverter functionality, and substation/line step-voltage regulators (SVR). A composite bus model comprising of DER, Delta- and Wye-connected load is proposed to represent a generic distribution bus, which can be simplified to load, PV, or voltage-controlled bus as required. Furthermore, the proposed matrix-based analytical method consolidates voltage magnitude and angle sensitivity to active/reactive power injection and tap-position of all SVRs into a single algorithm. Extensive case studies on IEEE and EPRI networks show the accuracy and wide scope of the proposed algorithm compared to the existing benchmark method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secure State Estimation with Asynchronous Measurements for Coordinated Cyber Attack Detection in Active Distribution Systems

Coordinated cyber attacks tamper with measurement data to disrupt the situational awareness of active distribution systems. Various sensors report measurements asynchronously at different rates, which introduces challenges during state estimation. In addition, this forces cyber intruders to exert greater effort to compromise multiple communication channels and launch coordinated attacks. Therefore, multi-channel and asynchronous measurements could be harnessed to develop more secure cyber defense strategies. In this paper, a prediction-correction-based multi-rate observer is designed to exploit the value of asynchronous measurements for the detection of coordinated false data injection (FDI) attacks. First, a time-function-dependent prediction-correction strategy is proposed to adjust the sampling interval for each sensor’s measurement. Then, an observer is designed based on the trade-off between estimation error and the optimal period of the most recent sampling instant, with the convergence of estimation error with the maximum permitted sampling interval. Moreover, the conditions for exponential stability are developed using the Lyapunov–Krasovskii functional technique. Next, a coordinated FDI attack detection strategy is developed based on the dual nonlinear minimization problem. The proposed attack detection and secure state estimation strategies are tested on the IEEE 13-node system. Simulation results show that these schemes are effective in enhancing attack detection based on asynchronous measurements or compromised data.

asynchronous measurements↗

Model-Free State Estimation Using Low-Rank Canonical Polyadic Decomposition

As electric grids experience high penetration levels of renewable generation, fundamental changes are required to address real-time situational awareness. Here, we utilize unique traits of tensors to devise a model-free situational awareness and energy forecasting framework for distribution networks. This work formulates the state of the network at multiple time instants as a three-way tensor; hence, recovering full state information of the network is tantamount to estimating all the values of the tensor. Given measurements received from µphasor measurement units and/or smart meters, the recovery of unobserved quantities is carried out using the low-rank canonical polyadic decomposition of the state tensor—that is, the state estimation task is posed as a tensor imputation problem utilizing observed patterns in measured (sampled) quantities. Two structured sampling schemes are considered, namely, asynchronous slab and fiber sampling. For both schemes, we present sufficient conditions on the number of sampled slabs and fibers that guarantee identifiability of the factors of the state tensor. Numerical results demonstrate the ability of the proposed framework to achieve high estimation accuracy in multiple sampling scenarios.

42 ENGINEERING↗

SolarExPert: Large-Scale OPF, DSSE and HIL

This presentation, part of the ADMS Test Bed Webinar Series, discusses how to accelerate industry adoption of ADMS to improve normal operations with high levels of distributed energy resources (DERs) and improve resilience and reliability.