Search NASA⌕ Search

SEARCH · Search NASA

Results for “divertors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Impact of nitrogen molecular breakup on divertor conditions in JET L-mode plasmas using SOLPS-ITER

SOLPS-ITER simulations of nitrogen-seeded, low-confinement mode plasmas in the Joint European Torus (JET) predict that the electron temperature in the low-field side (LFS) divertor leg is reduced locally by up to an order of magnitude when nitrogen is assumed to recycle as molecules (N 2 ) instead of atoms using a fixed nitrogen injection rate. The LFS divertor temperature reduction under the assumption of molecular recycling occurs due to a three-step mechanism: (1) the plasma penetration of nitrogen atoms is increased due to the strong triple bond of the N 2 molecule and the kinetic energy release in the dissociation event, both mechanisms contributing equally, (2) the abundance of (particularly multiply-charged) nitrogen ions in the divertor is increased and (3) the electron temperature is reduced due to the increase in radiation (by up to a factor of 4) from nitrogen ions. Setting the volume-integrated nitrogen radiated power to a constant value (0.6 MW) instead of the nitrogen injection rate, SOLPS-ITER predicts under the molecular nitrogen recycling assumption that the peak line-integrated N II, N III and N IV intensities in the LFS divertor are approximately within 15%, 35% and 5%, respectively, of the reference atomic nitrogen recycling case. The predicted peak N II, N III and N IV intensities under either assumption are within 30%, 65% and 5%, respectively, of measurements using the vertically viewing mirror-link divertor spectrometer (Meigs et al., 2010) in nitrogen-seeded JET L-mode plasmas (Lomanowski et al., 2019). ERO2.0 simulations using a constant nitrogen seeding rate on static background plasma solutions from EDGE2D-EIRENE (previously presented in Mäenpää et al., (2022), revised here to include fast reflections) predict that N II to N IV line emission is increased by 20% to 30% when nitrogen is assumed to recycle as molecules, demonstrating the importance of considering the effect of molecular dissociation reactions on the divertor plasma in a self-consistent manner.

Divertor↗

Comparison of private flux region instability in conventional and super-X divertor configurations

Understanding turbulence in the divertor leg of tokamaks is essential to predicting the heat deposition profile on the divertor plate. This in turn is important for evaluating advanced divertor configurations, such as the super-X divertor. Within the divertor region, the private flux region is of interest because it is relatively unaffected by turbulence extending from the outboard midplane, so instabilities in this region could have a particularly pronounced effect on transport. These instabilities are modeled using the Arbitrary Topology Equation Reader (ArbiTER) eigenvalue code. Eigenmodes are examined further by comparing physics models to determine the fundamental mechanisms behind their formation, and quantifying the effect of individual terms. This analysis is conducted on both conventional and super-X divertors to compare these effects. Here, the resulting analysis reveals the presence of a geodesic curvature driven instability that is significantly more pronounced in the super-X configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A reduced-model (nSOLT) simulation of neutral recycling effects on plasma turbulence in the divertor region of MAST-U

The 2D scrape-off-layer turbulence code (nSOLT), which includes 1D kinetic neutral–plasma interactions, is applied to study effects of neutral recycling on plasma turbulence for parameters illustrative of the MAST-U divertor region. Neutral recycling is modeled by injecting a fraction of the parallel plasma flux to the divertor back into the simulation domain as a source of Franck–Condon-distributed neutrals. Stationary sources, concentrated at the magnetic separatrix, model plasma streaming into the divertor region from the upstream scrape-off-layer and sustain plasma turbulence absent neutral recycling. Starting from one such no-neutrals equilibrium, we initiate recycling in a numerical experiment designed to diagnose and identify the effects of various neutral–plasma interactions on the divertor plasma, divertor turbulence, and plasma exhaust. The onset of recycling triggers an initial burst of enhanced cross field plasma transport that is quelled by ionization cooling and charge–exchange (CX) friction, with growing neutral pressure, leading to a quiescent, turbulence-free state. Diagnosis of this transient burst reveals that (1) the sudden increase in plasma density due to ionization dominates the onset of the burst, (2) electron cooling due to ionization increases collisionality and disconnects blob filaments from the sheath, and (3) CX friction drives tripole polarization of a blob that can dominate the curvature-driven dipole polarization, leading to the stagnation of blob propagation and reduced radial turbulent transport. It is shown that CX friction is negligible compared to sheath physics in determining equilibrium mean flow shearing rates, for parameters considered herein (specifically a short connection length to the divertor target), while it can significantly reduce interchange-instability growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of plasma–atom and molecule interactions on power & particle balance during detachment on the MAST Upgrade Super-X divertor

This paper shows first quantitative analysis of the detachment processes in the MAST Upgrade Super-X divertor (SXD). We identify an unprecedented impact of plasma-molecular interactions involving molecular ions (likely $D^+_2$), resulting in strong ion sinks (Molecular Activated Recombination—MAR), leading to a reduction of ion target flux. The MAR ion sinks exceed the divertor ion sources before electron-ion recombination (EIR) starts to occur, suggesting that significant ionisation occurs outside of the divertor chamber. In the EIR region, $T_e \ll 0.2$ eV is observed and MAR remains significant in these deep detached phases. The total ion sink strength demonstrates the capability for particle (ion) exhaust in the Super-X Configuration. Molecular Activated Dissociation is the dominant volumetric neutral atom creation process can lead to an electron cooling of 20% of $P_\mathrm{SOL}$. The measured total radiative power losses in the divertor chamber are consistent with inferred hydrogenic radiative power losses. This suggests that intrinsic divertor impurity radiation, despite the carbon walls, is minor in the divertor chamber. This contrasts previous TCV results, which may be associated with enhanced plasma-neutral interactions and reduced chemical erosion in the detached, tightly baffled SXD. The above observations have also been observed in higher heat flux (narrower SOL width) type I ELMy H-mode discharges. This provides evidence that the characterisation in this paper may be general.

plasma-molecular interactions↗

Effect of outer divertor leg detachment on the high field side scrape-off layer in DIII-D and ASDEX Upgrade

In this work, evidence is presented that detachment of the outer divertor leg leads to a reduction of electron density and neutral pressure in the high-field side (HFS) scrape-off layer (SOL) of the ASDEX Upgrade (AUG) and DIII-D tokamaks with ion $B$ x $∇B$ drift directed toward the X-point (favorable configuration). These results are observed across multiple diagnostics and without the use of impurity seeding to reach detachment. In AUG, outer divertor leg detachment correlates with a decrease in electron density near the separatrix at the inner midplane, measured with HFS reflectometry. A concurrent reduction in inner divertor density and neutral pressure at the inner target is observed using divertor Thomson scattering and neutral pressure gauges. These effects are present in both L- and H-mode plasmas. In DIII-D, a similar reduction is detected through analysis of line-integrated hydrogenic emission measured by multiple diagnostics in the HFS SOL close to the separatrix. The consistent trends in both devices indicate that high electron density and strong hydrogenic emissivity in the HFS SOL are common features of H-mode plasmas in the favorable configuration, independent of wall material and divertor geometry. In L-mode plasmas, the reduction in electron density and neutral pressure is not observed in DIII-D, possibly due to differences in wall material. These results emphasize the importance of the divertor state in determining the two-dimensional neutral distribution and edge fueling.

detachment↗

Multiphysics Analysis of Li Cooled Divertor Substrate During Loss of Coolant Accident (LOCA)

In the ongoing study of potential designs for liquid metal (LM) plasma-facing components (PFCs), so-called “slow” and “fast” Li flow divertor concepts are under investigation. In the previous studies on design and analysis of the slow Li flow divertor and comparison with the fast Li flow divertor, the magnetohydrodynamics (MHD)/heat transfer effects of the Li flowing inside the substrate as a second coolant were comprehensively investigated under the normal steady-state operation conditions. Here, in the present study, the multiphysics analysis is extended to the unsteady abnormal divertor scenario where the Li layer on top of the substrate does not provide full coverage or even totally disappears for a certain period of time, so that the substrate becomes directly exposed to the incident high plasma heat flux. Such an unwanted event may happen regardless of the concept of the divertor and is worth detailed investigations, typically referred to as a loss of coolant accident (LOCA). To address this situation, a simplified scoping analysis is conducted first in 2-D, and then an integrated 3-D modeling is performed using a time-dependent multiphysics model in COMSOL Multiphysics that integrates LM MHD, heat transfer, and solid mechanics. The main goal is to evaluate conditions under which the major material limits, such as the maximum allowable temperature, stress, and displacement of the substrate, can still be met. It was shown that the maximum time over which the substrate of RAFM steel can retain structural integrity during the LOCA is around 0.2 ∼ 0.3 s. Any divertor concept that utilizes RAFM steel as a substrate material and liquid Li as a second coolant should take such a permitted time into consideration.

divertor↗

Investigations of atomic and molecular processes of NBI-heated discharges in the MAST Upgrade Super-X divertor with implications for reactors

This experimental study presents an in-depth investigation of the performance of the MAST-U Super-X divertor during NBI-heated operation (up to 2.5 MW) focussing on volumetric ion sources and sinks as well as power losses during detachment. The particle balance and power loss analysis revealed the crucial role of Molecular Activated Recombination and Dissociation (MAR and MAD) ion sinks in divertor particle and power balance, which remain pronounced in the change from ohmic to higher power (NBI heated) L-mode conditions. The importance of MAR and MAD remains with double the absorbed NBI heating. MAD results in significant power dissipation (up to ${\sim} 20\%$ of $P_\textrm{SOL}$), mostly in the cold ($T_e \lt 5$ eV) detached region. Theoretical and experimental evidence is found for the potential contribution of $D^-$ to MAR and MAD, which warrants further study. These results suggest that MAR and MAD can be relevant in higher power conditions than the ohmic conditions studied previously. Post-processing reactor-scale simulations suggests that MAR and MAD can play a significant role in divertor physics and synthetic diagnostic signals of reactor-scale devices, which are currently underestimated in exhaust simulations. This raises implications for the accuracy of reactor-scale divertor simulations of particularly tightly baffled (alternative) divertor configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Divertor shaping with neutral baffling as a solution to the tokamak power exhaust challenge

Exhausting power from the hot fusion core to the plasma-facing components is one fusion energy’s biggest challenges. The MAST Upgrade tokamak uniquely integrates strong containment of neutrals within the exhaust area (divertor) with extreme divertor shaping capability. By systematically altering the divertor shape, this study shows the strongest evidence to date to our knowledge that long-legged divertors with a high magnetic field gradient (total flux expansion) deliver key power exhaust benefits without adversely impacting the hot fusion core. These benefits are already achieved with relatively modest geometry adjustments that are more feasible to integrate in reactor designs. Benefits include reduced target heat loads and improved access to, and stability of, a neutral gas buffer that ‘shields’ the target and enhances power exhaust (detachment). Analysis and model comparisons shows these benefits are obtained by combining multiple shaping aspects: long-legged divertors have expanded plasma-neutral interaction volume that drive reductions in particle and power loads, while total flux expansion enhances detachment access and stability. Containing the neutrals in the exhaust area with physical structures further augments these shaping benefits. These results demonstrate strategic variation in the divertor geometry and magnetic topology is a potential solution to one of fusion’s power exhaust challenge.

magnetically confined plasmas↗

Improved core-edge compatibility using impurity seeding in the small angle slot (SAS) divertor at DIII-D

Impurity seeding studies in the slot divertor (SAS) at DIII-D have revealed a strong relationship between the detachment onset and pedestal characteristics with both target geometry and impurity species. N 2 seeding in the slot has led to the first simultaneous observation of detachment on the entire suite of boundary diagnostics viewing the SAS without degradation of core confinement. SOLPS-ITER simulations with D+C+N, full cross-field drifts and n-n collisions activated are performed for the first time in DIII-D to interpret the behavior. This illustrates a strong effect of divertor configuration and plasma drifts on the recycling source distribution with significant consequences on plasma flows. Flow reversal is found for both main ions and impurities affecting strongly the impurity transport and providing an explanation for the observed dependence on strike point location of the detachment onset and impurity leakage found in the experiments. Matched discharges with either nitrogen or neon injection show that while nitrogen does not significantly affect the pedestal, neon leads to increased pedestal pressure gradient and improved pedestal stability. Little nitrogen penetrates in the core, but a great amount of neon is found in the pedestal consistent with the different ionization potentials of the two impurities. This research demonstrates that neutral and impurity distributions in the divertor can be controlled through variations in strike point locations in a fixed baffle structure. Divertor geometry combined with impurity seeding enables mitigated divertor heat flux balancing core contamination and thus leading to enhanced divertor dissipation and improved core-edge compatibility which are essential for ITER and for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of multiple heat flux components at the divertor target by using surface eroding thermocouples (invited)

The Surface Eroding Thermocouple (SETC) is a robust diagnostic utilized in DIII-D to provide fast, edge-localized modes (ELMs) resolved heat flux measurements, in particular in geometric regions that are too shadowed for traditional infrared thermography. In order to further investigate the power dissipation in the divertor region, a combination of flush-mounted and recessed SETCs was developed to assess the effect on surface heating from non-charged particles at the divertor target. Utilizing the Divertor Materials Evaluation System sample exposure platform, the first demonstration of the feasibility of using this new method to distinguish between the heat flux from charged particles and that from neutrals and radiative heating was achieved. This paper details the process of using the combination of flush SETCs and recessed SETCs to measure the multiple heat flux components at the divertor target and further discusses how to determine two important ratios, α (ratio of heat flux from charged particles deposit on recessed SETC to that deposit on flush SETC) and β (ratio of heat flux from non-charged particles deposit on recessed SETC to that deposit on flush SETC), in the estimation of the heat flux from non-charged particle sources. Using a time dependent ratio α, it was found that ~50% of the total incident heat flux is attributable to the non-charged particles in the fully detached open divertor in DIII-D. Finally, the new application of similar SETC diagnostics in the Small Angle Slot divertor with a V-like configuration and partial tungsten coated surface (SAS-VW) is also introduced.

47 OTHER INSTRUMENTATION↗

Benefits of the Super-X divertor configuration for scenario integration on MAST Upgrade

The integration of good core and edge/pedestal confinement with strong dissipation of heat and particles in the divertors is a significant challenge for the development of fusion energy. Alternative divertor configurations offer potential advantages by broadening the operational space where a device can operate with detached divertors and acceptable power exhaust. First results from MAST Upgrade are presented from high confinement mode experiments with outer divertors in the Super-X divertor configuration, showing that the outer divertors naturally detach when the Super-X is formed with no discernible impact on the plasma core and pedestal. These initial findings confirm predicted benefits of the Super-X configuration in terms of facilitating scenario integration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of divertor material on neutral recycling and discharge fueling in DIII-D

We report that experiments with the lower divertor of DIII-D during the Metal Rings Campaign (MRC) show that the fraction F of atomic D in the total recycling flux is material-dependent and varies through the ELM cycle, which may affect divertor fueling. Between ELMs, F C ~ 10% and FW ~ 40%, consistent with expectations if all atomic recycling is due to reflections. During ELMs, F C increases to 50% and F W to 60%. In contrast, the total D recycling coefficient including atoms and molecules R stays close to unity near the strike point where the surface is saturated with D. During ELMs, R can deviate from unity, increasing during high energy ELM-ion deposition (net D release) and decreasing at the end of the ELM which leads to ability of the target to trap the ELM-deposited D. The increase of R > 1 in response to an increase in ion impact energy Ei has been studied with small divertor target samples using Divertor Materials Evaluation System (DiMES). An electrostatic bias was applied to DiMES to change E i by 90 eV. On all studied materials including C, Mo, uncoated and W-coated TZM (>99% Mo, Ti, and Zr alloy), W, and W fuzz, an increase of E i transiently increased the D yield (and R) by ~10%. On C there was also an increase in the molecular D 2 yield, probably due to ion-induced D 2 desorption. Despite the measured increase in F on W compared to C, attached H-mode shots with OSP on W during MRC did not demonstrate a higher pedestal density. About 8% increase in the edge density could be seen only in attached L-mode scenarios. The difference can be explained by higher D trapping in the divertor and lower divertor fueling efficiency in H- versus L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM and inter-ELM heat and particle flux to a secondary divertor in the DIII-D tokamak

DIII-D ELMing discharges with a secondary X-point (XPT) inside the vessel were used to evaluate the power distribution between the primary and secondary divertors. The magnetic balance, defined by the distance between the primary and secondary separatrices at the outer midplane (dRsep), was varied from -5 mm (lower-single-null, LSN) to +16 mm (upper-single-null, USN). In this work, we find that the secondary divertor receives up to 1/3 of the total heat flux (primary + secondary divertors), and it is dominated by the ELM-driven flux. Both the radially-integrated and the peak heat flux to the secondary divertor decay below ~50% of the maximum as dRsep is varied from -5 to +6mm, but the integrated heat flux decay flattens out and it would take dRsep above ~25mm to reduce the ELM heat flux to the secondary divertor below 10% of the one deposited to a well-defined SN. Both the secondary inner and outer strike points receive heat flux during ELMs. The peak heat flux is comparable in both strike points for dRsep < 10mm, but the inner strike point receives less than 15% of the total flux. Furthermore, this is experimental evidence that the secondary inner divertor region receives significant ELM flux which should be taken into account for the design of future generation tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of ExB effects on tungsten re-deposition and transport in the DIII-D divertor

Mixed-material DIVIMP-WallDYN modelling, now incorporating ExB drifts, is presented that simultaneously reproduces tungsten (W) erosion and deposition patterns observed during the DIII-D Metal Rings Campaign, in which a toroidally symmetric set of W-coated tiles were installed in the carbon (C) DIII-D divertor. Since most reactor plasma facing component (PFC) designs call for mixed-material environments, including ITER’s W/Be enviroment, the divertor targets will quickly evolve into reconstitued surfaces of multiple elements. This work identifies controlling physics that affects material migration patterns in the divertor, which impact PFC lifetimes and impurity leakage from the divertor to the core. These simulations indicate that radial and poloidal ExB transport dominates over parallel force balance for high-Z impurities such as W in the divertor region of DIII-D. It is demonstrated that ExB drifts are required to reproduce the experimental observation of non-local W and C co-accumulation in a band ~7-9 cm outboard of the outer-strike-point (OSP) W source, for attached Lmode conditions in the unfavorable ion grad-B drift direction. In addition, W gross erosion is localized to the region outboard of the OSP, as the formation of C co-deposits suppresses W erosion at the strike point. Time-dependent simulations with scaled ExB impurity drifts (60% of the OEDGE-calculated drift velocity) and W re-erosion quantitatively reproduce these features, including depth-resolved W/C ratios, within a factor of 2 over ~115 seconds of accumulated plasma exposure. The location of co-deposition regions is shown to be well represented by an analytic leakage model, driven largely by poloidal ExB drifts. Qualitative agreement is also found between campaign-integrated W deposition measurements and simulations for the favorable ion grad-B drift direction, the standard mode of operation for most tokamaks. Furthermore, these results imply that a longterm inward radial migration of material from the outer divertor through the private flux region may occur in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Snowflake Divertors in MAST-U Tokamak

We report that in a snowflake (SF) divertor, two magnetic field nulls are placed close to each other, creating four strike points (SPs) compared to two in a standard X-point divertor. In preparation for MAST-U experiments, magnetic configurations with the standard and SF divertors with various locations and separation distances of the nulls were modeled using the two-dimensional multi-fluid code UEDGE with a full plasma transport model featuring charge-state-resolved sputtered carbon impurities. The complex interplay of the plasma transport and magnetic configurations was comprehensively studied using a simple model for the theoretically predicted fast plasma mixing driven by the 'churning' mode instability in the two-null SF region. The modeling results show that (1) all SF-plus configurations and SF-minus configuration with closely located nulls produce the same plasma parameters and heat fluxes at the same SPs; (2) SF divertors approach the outer and inner SP detachment conditions at lower upstream density w.r.t. the standard divertor; (3) heat flux profiles at primary SPs are substantially broadened and peak values are reduced in SF configurations w.r.t. SN divertors; this broadening becomes more pronounced with the fast plasma mixing increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of the isotope effect on divertor detachment and pedestal structure in DIII-D

Dedicated H-mode hydrogen experiments have been conducted at DIII-D and are compared to similar deuterium plasmas under a range of divertor conditions, revealing significant effects of the isotope mass on divertor and pedestal conditions. H-mode confinement is found to be systematically lower in hydrogen and experiences a worse degradation with increased fueling. This coincides with a higher ne,sep in hydrogen for similar fueling rates. When ne,ped is matched in hydrogen and deuterium as are the ne and Te pedestal structures, the target conditions deviate strongly from each other. An analysis of two major factors in the pedestal structure, pedestal stability and neutral fueling, shows they are not sufficient to explain either the pedestal differences between isotopes or the hydrogen pedestal structure respectively. An analysis of hydrogen and deuterium density ramps demonstrates a 20% higher ion current and a 30% higher upstream density at detachment onset in hydrogen. The characteristics of target heat flux and divertor radiation are shown to change significantly with the isotope mass in each divertor operational regime. The results shown here indicate divertor conditions trend with ion mass in a manner beneficial for divertor performance in future devices.

Mattes, Ray [Univ. of Tennessee, Knoxville, TN (Un↗

Reversed-direction 2-point modelling applied to divertor conditions in DIII-D *

Abstract A predictive form of the extended 2-point model known as the ‘reverse 2-point model’, Rev2PM, is applied to a range of detachment levels in the open lower divertor of DIII-D, showing that the experimentally measured electron temperature ( T e ) and pressure ( p e ) at the divertor entrance can be calculated within 50% from target measurements, if and only if a posteriori corrections for convective heat flux are included in the model. Unlike the standard 2-point model, the Rev2PM calculates upstream scrape-off layer (SOL) quantities (such as separatrix T e and p e ) from target conditions (such as T e and parallel heat flux), with volumetric power and momentum losses depending solely on target T e . The Rev2PM is tested against a database of DIII-D inter-ELM divertor Thomson scattering measurements, built from a series of 6 MW, 1.3 MA, LSN H-mode discharges with varied main ion density, drift direction, and nitrogen puffing rate. Measured target T e ranged from 0.4–25 eV over this database, and upstream T e ranged from 5–60 eV. Poor agreement is found between upstream measurements and Rev2PM calculations that assume purely conductive parallel heat transport. However, introducing a posteriori corrections to account for convective heat transport brings the Rev2PM calculations within 50% of the measured upstream values across the dataset. These corrections imply that up to 99% of the parallel heat flux is carried by convection in detached conditions in the DIII-D open lower divertor, though further work is required to assess any potential dependencies on device size or divertor closure.

2-point model↗