Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose prediction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Meeting Radiation Protection Requirements and Reducing Spacecraft Mass - A Multifunctional Materials Approach

Both crew and radio-sensitive systems, especially electronics must be protected from the effects of the space radiation environment. One method of mitigating this radiation exposure is to use passive-shielding materials. In previous vehicle designs such as the International Space Station (ISS), materials such as aluminum and polyethylene have been used as parasitic shielding to protect crew and electronics from exposure, but these designs add mass and decrease the amount of usable volume inside the vehicle. Thus, it is of interest to understand whether structural materials can also be designed to provide the radiation shielding capability needed for crew and electronics, while still providing weight savings and increased useable volume when compared against previous vehicle shielding designs. In this paper, we present calculations and analysis using the HZETRN (deterministic) and FLUKA (Monte Carlo) codes to investigate the radiation mitigation properties of these structural shielding materials, which includes graded-Z and composite materials. This work is also a follow-on to an earlier paper, that compared computational results for three radiation transport codes, HZETRN, HETC, and FLUKA, using the Feb. 1956 solar particle event (SPE) spectrum. In the following analysis, we consider the October 1989 Ground Level Enhanced (GLE) SPE as the input source term based on the Band function fitting method. Using HZETRN and FLUKA, parametric absorbed doses at the center of a hemispherical structure on the lunar surface are calculated for various thicknesses of graded-Z layups and an all-aluminum structure. HZETRN and FLUKA calculations are compared and are in reasonable (18% to 27%) agreement. Both codes are in agreement with respect to the predicted shielding material performance trends. The results from both HZETRN and FLUKA are analyzed and the radiation protection properties and potential weight savings of various materials and materials lay-ups are compared.

Atwell, William↗

Indirectly probing the structural change in ion-irradiated Zr-Based metallic glasses from small scale mechanical tests

Ion irradiation was applied to tailor the structural heterogeneities in Zr-based metallic glasses at room temperature. Experimental methods of X-ray diffraction, nanoindentation, and micropillar compression were conducted to examine the irradiation effects on their structural and mechanical property changes. It is found that the irradiated materials retained amorphous structure after room-temperature Ni ion irradiation. The reduction of elastic modulus and hardness measured by nanoindentation indicated the irradiation-induced mechanical degradation. A unified statistic model was employed to quantitatively predict the density and strength of irradiation defects, although their specific structural and physical nature is not explicitly included in this model. The transition of non-intersecting shear bands to multiple intersecting shear bands was observed on compression tests of irradiated micropillars with the increase of irradiation dose. Furthermore, the analysis of the displacement excursion of micropillar compression tests indicated a different deformation mode from the unirradiated state. These results from nanoindentation pop-in and micro-pillar compression tests suggested that irradiation eventually leads to a new state with different types and characteristics of structural heterogeneities from violent displacement cascades and non-equilibrium energy deposition/dissipation processes, which also proves ion irradiation as an effective method to tune the structure and mechanical properties of metallic glasses.

36 MATERIALS SCIENCE↗

The importance of delayed neutron precursors in gamma dose calculations for activated primary heat exchanger components in the Molten Salt Breeder Reactor

The Molten Salt Reactor (MSR) Multiphysics Applications technical area in the Nuclear Energy Advanced Modeling and Simulation program has supported the development of 3D Monte Carlo models of the Molten Salt Breeder Reactor (MSBR) over the last couple of years. This MSBR model was previously run with the Shift Monte Carlo code to perform radiation shielding calculations in the reactor cell area. The MSBR is a 2250 MWth (1000 MWe) liquid-fueled molten salt reactor design developed at Oak Ridge National Laboratory in the 1970s. Determining the source terms from activated primary heat exchanger (HX) components is important because delayed and prompt neutron fluxes incident on these components affect the dose rate in the primary HX maintenance areas. This information can be used in the development of remote handling procedures required during shutdown for maintenance. A methodology has been developed and is proposed in this paper to quantify the activated source term from the primary HX components as a result of the movement of the delayed neutron precursors in flowing primary fuel salt through the primary HXs in the MSBR. The goal of this research is to evaluate the gamma dose rates in the maintenance hatches above the primary HX using the activated HX source terms. The study showed that the gamma dose rates are approximately two orders of magnitudes higher when accounting for the neutron activation from the movement of delayed neutron precursors through the HXs than when flowing fuel is not considered. Thus, the movement of delayed neutron precursors must be taken into account for accurately predicting the neutron activation of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A spatially-resolved model of neutron-irradiated tungsten coupling stochastic cluster dynamics and finite deformation plasticity

Structural materials used in nuclear reactors face severe degradation in mechanical properties, such as hardening and embrittlement. At the microscopic scale, this occurs due to creation and accumulation of irradiation-induced defects and their interaction with system dislocations. Although techniques exist which can model evolution of irradiation defects, for instance kinetic transport theory-based models, their interaction with mechanical deformation of the bulk material has not been investigated extensively. In this work, we demonstrate a novel spatially-resolved multiscale coupling between microscopic irradiation defect evolution, modeled using Stochastic Cluster Dynamics (SCD) and macroscopic mechanical deformation modeled using a finite-deformation plasticity model. SCD is used to determine the statistically averaged defect cluster spacing, dependent on operating conditions such as irradiation dose and temperature. This acts as an initial condition that governs the critical resolved shear stress of dislocation glide in the macroscopic plasticity model. This framework is used to predict mechanical behavior in post-mortem test of irradiated Tungsten samples, which has found its importance as structural material used in nuclear reactors. The results obtained using the coupled approach are in good agreement with experimental data of uniaxial tension tests. The model is able to capture the effect of temperature and irradiation dose on the material hardening. Two methods are proposed to estimate hardness – using Tabor's Law relating uniaxial yield stress to hardness and from flat-punch simulations. The results are in reasonable agreement with hardness data from micro-indentation experiments of irradiated Tungsten samples. Finally, the model is also able to reveal microstructural details such as spatial variation in defect density and local stress.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The genotype-phenotype landscape of an allosteric protein

Allostery is a fundamental biophysical mechanism that underlies cellular sensing, signaling, and metabolism. Yet a quantitative understanding of allosteric genotype-phenotype relationships remains elusive. Here, we report the large-scale measurement of the genotype-phenotype landscape for an allosteric protein: the lac repressor from Escherichia coli , LacI. Using a method that combines long-read and short-read DNA sequencing, we quantitatively measure the dose-response curves for nearly 10 5 variants of the LacI genetic sensor. The resulting data provide a quantitative map of the effect of amino acid substitutions on LacI allostery and reveal systematic sequence-structure-function relationships. We find that in many cases, allosteric phenotypes can be quantitatively predicted with additive or neural-network models, but unpredictable changes also occur. For example, we were surprised to discover a new band-stop phenotype that challenges conventional models of allostery and that emerges from combinations of nearly silent amino acid substitutions.

59 BASIC BIOLOGICAL SCIENCES↗

A Cell Kinetic Model of Granulocytopoiesis Under Radiation Exposure: Extension from Murines to Canines and Humans

Space radiation poses significant challenges to space travel, and it is essential to understand the possible adverse effects from space radiation exposure to the radiosensitive organ systems that are important for immediate survival of human, e.g., the hematopoietic system. In this presentation a biomathematical model of granulocytopoiesis is described and used to analyze the blood granulocyte changes seen in the blood of mammalians under continuous and acute radiation exposure. This is one of a set of hematopoietic models that have been successfully utilized to simulate and interpret the experimental data of acute and chronic radiation on rodents. We discuss the underlying implicit regulation mechanism and the biological relevance of the kinetic parameters estimation method. Extension of the model to predictions in dogs and humans systems indicates that the modeling results are consistent with the cumulative experimental and empirical data from various sources. This implies the potential to integrate the models into one united system for monitoring the hematopoietic response of various species under irradiation. Based on the evidence of threshold responses of dogs to extended periods of low daily dose exposures, we discuss the potential health risks of the space traveler under chronic stress of low-dose irradiation and the possibly encountered Solar Particle Events.

Hu, Shaowen↗

Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Predictions of LDEF radioactivity and comparison with measurements

As part of the program to utilize LDEF data for evaluation and improvement of current ionizing radiation environmental models and related predictive methods for future LEO missions, calculations have been carried out to compare with the induced radioactivity measured in metal samples placed on LDEF. The predicted activation is about a factor of two lower than observed, which is attributed to deficiencies in the AP8 trapped proton model. It is shown that this finding based on activation sample data is consistent with comparisons made with other LDEF activation and dose data. Plans for confirming these results utilizing additional LDEF data sets, and plans for model modifications to improve the agreement with LDEF data, are discussed.

Armstrong, T. W.↗

Machine Learning Models to Predict Cognitive Impairment of Rodents Subjected to Space Radiation

This research uses machine-learned computational analyses to predict the cognitive performance impairment of rats induced by irradiation. The experimental data in the analyses is from a rodent model exposed to ≤ 15 cGy of individual Galactic Cosmic Radiation (GCR) ions: 4He, 16O, 28Si, 48Ti, or 56Fe, expected for a Lunar or Mars mission. This work investigates rats at a subject-based level and uses performance scores taken before irradiation to predict impairment in Attentional Set-shifting (ATSET) data post-irradiation. Here, the worst performing rats of the control group define the impairment thresholds based on population analyses via cumulative distribution functions, leading to the labeling of impairment for each subject. A significant finding is the exhibition of a dose-dependent increasing probability of impairment for 1 to 10 cGy of 28Si or 56Fe in the Simple Discrimination (SD) stage of the ATSET, and for 1 to 10 cGy of 56Fe in the Compound Discrimination (CD) stage. On a subject-based level, implementing Machine Learning (ML) classifiers such as the Gaussian Naïve Bayes, Support Vector Machine, and Artificial Neural Networks identifies rats that have a higher tendency for impairment after GCR exposure. The algorithms employ the experimental prescreenperformance scores as multidimensional input features to predict each rodent’s susceptibility to cognitive impairment due to space radiation exposure. The receiver operating characteristic and the precision-recall curves of the ML models show a better prediction of impairment when 56Feis the ion in question in both SD and CD stages. They, however, do not depict impairment due to 4Hein SD and 28Siin CD, suggesting no dose-dependent impairment response in these cases. One key finding of our study is that prescreen performance scores can be used to predict the ATSET performance impairments. This result is significant to crewed space missions as it supports the potential of predicting an astronaut’s impairment in a specific task before spaceflight through the implementation of appropriately trained ML tools. Future research can focus on constructing ML ensemble methods to integrate the findings from the methodologies implemented in this study for morerobust predictionsof cognitive decrements due to space radiation exposure.

space radiation↗

Mitigating the Impacts of Measurement Error in the Quesst Mission Community Noise Study

Beginning in 2025, the NASA Quesst mission will conduct a series of community response tests involving flyovers of the X-59 aircraft at select localities across the United States. Several waves of a longitudinal survey will be administered over approximately one month of testing in order to capture perceptual responses to low-amplitude sonic booms, or “sonic thumps”. Simultaneously, noise exposure levels will be estimated by fusing model-based predictions with measurements taken from a sparse network of monitors in the region. As one of the aims of the study is to produce a dose-response curve, a regression model relating perceptual response to noise exposure levels, it is important to acknowledge the potential attenuation bias that results from measurement error in the estimated noise exposure levels. In this presentation we review and compare several methods for dealing with measurement error in generalized linear mixed models. The methods are demonstrated on simulated data and real data collected during past NASA risk reduction studies.

measurement error↗

Benchmark solutions for the galactic ion transport equations: Energy and spatially dependent problems

Nontrivial benchmark solutions are developed for the galactic ion transport (GIT) equations in the straight-ahead approximation. These equations are used to predict potential radiation hazards in the upper atmosphere and in space. Two levels of difficulty are considered: (1) energy independent, and (2) spatially independent. The analysis emphasizes analytical methods never before applied to the GIT equations. Most of the representations derived have been numerically implemented and compared to more approximate calculations. Accurate ion fluxes are obtained (3 to 5 digits) for nontrivial sources. For monoenergetic beams, both accurate doses and fluxes are found. The benchmarks presented are useful in assessing the accuracy of transport algorithms designed to accommodate more complex radiation protection problems. In addition, these solutions can provide fast and accurate assessments of relatively simple shield configurations.

Ganapol, Barry D.↗

Plasticity of irradiated materials at the nano and micro-scales

Here, we review here our recent work on plastic deformation in irradiated materials at the nano- and micro-scales, as revealed by Discrete Dislocation Dynamics (DDD) simulations. Two methods of including irradiation effects in the DDD framework are presented. The first directly captures the atomistic interaction mechanisms, while the second can effectively study high-dose irradiation. Computer simulations lead to new understanding of the dynamics of collective dislocation-irradiation defect interactions, as well as the quantitative analysis of the temporal and spatial characteristics associated with plastic instabilities. Based on these insights, theoretical models are developed to predict the critical conditions for dislocation channel formation. A simple probability model is proposed and demonstrated to predict the width of dislocation channels in bulk irradiated materials with good agreement with experimental data. The fundamental understanding of the origins of plastic flow localization in irradiated materials sheds light on the design of future generations of radiation-resistant materials.

36 MATERIALS SCIENCE↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Solvent‐free enzymatic esterification of free fatty acids with glycerol for biodiesel application: Optimized using the Taguchi experimental method

Abstract Presence of free fatty acids along with glycerides poses a technical difficulty for biodiesel production. This work used a Taguchi L9 design to optimize the solvent‐free enzymatic process to result in the esterification of oleic acid with glycerol. Under optimal conditions the esterification reaction temperature of 60°C, enzyme dose of 5 wt%, glycerol: oleic acid molar ratio of 5:1, and reaction time of 3 h, a 75.235 ± 2.19% conversion of oleic acid to esters was achieved. With the addition of molecular sieves, the conversion increased to 86.73% ± 1.09%. However, using the parameters predicted by Taguchi design (60°C, 5 wt%, 5:1, and 4.5 h), 88.5% ± 1.11% of oleic acid could be converted to esters derivative. Diglycerides were the major product, and the reaction equilibrium was attained after 4 h. The immobilized enzyme could be used up to seven times with only a 10% reduction in the conversion. Thus, the process can efficiently reduce the free fatty acid content of oil to make it suitable for biodiesel production.

09 BIOMASS FUELS↗

Data for Solvent-Free Enzymatic Esterification of Free Fatty Acids with Glycerol for Biodiesel Application: Optimized Using the Taguchi Experimental Method

Presence of free fatty acids along with glycerides poses a technical difficulty for biodiesel production. This work used a Taguchi L9 design to optimize the solvent-free enzymatic process to result in the esterification of oleic acid with glycerol. Under optimal conditions the esterification reaction temperature of 60°C, enzyme dose of 5 wt%, glycerol: oleic acid molar ratio of 5:1, and reaction time of 3 h, a 75.235 ± 2.19% conversion of oleic acid to esters was achieved. With the addition of molecular sieves, the conversion increased to 86.73% ± 1.09%. However, using the parameters predicted by Taguchi design (60°C, 5 wt%, 5:1, and 4.5 h), 88.5% ± 1.11% of oleic acid could be converted to esters derivative. Diglycerides were the major product, and the reaction equilibrium was attained after 4 h. The immobilized enzyme could be used up to seven times with only a 10% reduction in the conversion. Thus, the process can efficiently reduce the free fatty acid content of oil to make it suitable for biodiesel production.

Conversion↗

Dose-Response Evaluation of Braslet-M Occlusion Cuffs

Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques.

Ebert, Douglas↗

Contrasting actions of pressor agents in severe autonomic failure

BACKGROUND: Orthostatic hypotension is the most disabling symptom of autonomic failure. The choice of a pressor agent is largely empiric, and it would be of great value to define predictors of a response. PATIENTS AND METHODS: In 35 patients with severe orthostatic hypotension due to multiple system atrophy or pure autonomic failure, we determined the effect on seated systolic blood pressure (SBP) of placebo, phenylpropanolamine (12.5 mg and 25 mg), yohimbine (5.4 mg), indomethacin (50 mg), ibuprofen (600 mg), caffeine (250 mg), and methylphenidate (5 mg). In a subgroup of patients, we compared the pressor effect of midodrine (5 mg) with the effect of phenylpropanolamine (12.5 mg). RESULTS: There were no significant differences in the pressor responses between patients with multiple system atrophy or pure autonomic failure. When compared with placebo, the pressor response was significant for phenylpropanolamine, yohimbine, and indomethacin. In a subgroup of patients, we confirmed that this pressor effect of phenylpropanolamine, yohimbine, and indomethacin corresponded to a significant increase in standing SBP. The pressor responses to ibuprofen, caffeine, and methylphenidate were not significantly different from placebo. Phenylpropanolamine and midodrine elicited similar pressor responses. There were no significant associations between drug response and autonomic function testing, postprandial hypotension, or plasma catecholamine levels. CONCLUSIONS: We conclude that significant increases in systolic blood pressure can be obtained in patients with orthostatic hypotension due to primary autonomic failure with phenylpropanolamine in low doses or yohimbine or indomethacin in moderate doses. The response to a pressor agent cannot be predicted by autonomic function testing or plasma catecholamines. Therefore, empiric testing with a sequence of medications, based on the risk of side effects in the individual patient and the probability of a response, is a useful approach.

Clinical Trial↗