Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose response model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Uncertainty Analysis of Inhalation Dose Coefficients for Nuclear Incident Response

This study addressed the need to characterize variability in inhalation dose coefficients due to uncertainties in respiratory tract deposition, systemic biokinetics, and physiological parameters. A Python-based implementation of the International Commission on Radiological Protection Publication 66 Human Respiratory Tract Model was developed called the Radiological Exposure Dose Calculator (REDCAL) to propagate parameter uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Summary of Analytical Services for the Hanford Site Radionuclide NESHAP Program

This document is a summary of the point source analytical requirements used to demonstrate compliance for the Department of Energy (DOE) Hanford Site operations with 40 Code of Federal Regulations (CFR) Part 61, “National Emission Standards for Hazardous Air Pollutants,” (NESHAP) Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities,” and the Washington Administrative Code (WAC) 246-247, “Radiation Protection – Air Emissions.” This reference collects information from multiple source documents and is not intended to create, supersede, replace or over-ride any existing contractual, DOE, federal or state statutes, regulations, compliance agreements, orders, permits, licenses or other requirements. The requirement source document governs where any difference may exist. The Hanford Mission Integration Solutions (HMIS) Environmental organization has been contracted by DOE to manage and report data collected from the sampling and monitoring of radioactive air emissions point sources, colloquially called stacks. The Environmental organization coordinates the analyses and reporting of samples collected at various facilities across the Hanford Site. These facilities operate approximately 52 stacks that require sampling, monitoring or estimating radioactive air emissions. The stacks are operated by Bechtel National, Inc. (BNI), Central Plateau Cleanup Company (CPCCo), Hanford Tank Waste Operations & Closure (H2C), Hanford Laboratory Management and Integration (HLMI), and Pacific Northwest National Laboratory (PNNL). Stack samples from CPCCo, HLMI and H2C facilities are collected by the operating contractor staff, delivered to HMIS, and then shipped to an offsite contracted laboratory for analyses. The field and laboratory sample data uploaded into the Sample Management and Analytical Results Tracking (SMART) database are used to calculate sample volumes and concentrations. Sample concentrations are evaluated for compliance with federal and state regulations, permits, and license requirements. The SMART database also calculates total curies released for sampled point sources and stacks. Point source effluent concentrations and releases are published annually in publicly available reports. The BNI and PNNL operate several DOE-Hanford Field Office (HFO) stacks subject to the requirements of 40 CFR 61, Subpart H and WAC 246-247. The concentrations, curies released and dose modeling evaluation for these stacks are included in the DOE-HFO annual radionuclide NESHAP report. The sample collection, analyses and emissions estimates for these stacks are outside the scope of HMIS contracted responsibilities and not addressed further in this document.

54 ENVIRONMENTAL SCIENCES↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

Mortality among workers at the Rocky Flats Plant, 1951–2017

The Rocky Flats (RFs) Plant operated from 1951–1989 as part of the U.S. Department of Energy (DOE) nuclear complex. Its primary mission was weapons component fabrication, whereby workers were potentially exposed to radioactive and non-radioactive hazards. RF worker mortality was compared to the general population, and dose-response relationships between mortality and radiation organ doses were examined. RF workers first employed between 1951 and 1979 for ⩾30 d were identified (n = 9397). Vital status was determined using national and state death records up to 2017. Organ doses from external photons and neutrons irritation and internalised plutonium (Pu), americium (Am), and uranium (U) were modelled as cumulative lagged total doses per year. Beryllium exposure was evaluated as an effect modifier using data from the DOE Nationwide Beryllium Medical Program. Statistical analyses included standardised mortality ratios (SMRs), Cox proportional hazard models, and excess relative risk (ERR) models. Approximately 53.2% of workers were deceased by the end of the study. Nearly 90% were monitored for radiation exposure, with a mean weighted absorbed dose of 59.0 mGy for the lungs. Nearly 45% of workers had intakes of alpha-particle emitting radionuclides, and 46.7% were monitored for neutrons. Leading causes of death included ischemic heart disease (n = 999) and lung cancer (n = 361). The highest SMRs were observed for berylliosis (SMR: 176.9; 95% CI: 76.2, 348.7; n < 10) and asbestosis (SMR: 4.65; 95% CI: 2.23, 8.55; n = 10). Dose-response analyses showed no statistical increase in risk from low-dose radiation including lung cancer (ERR per 100 mGy: −0.02; 95% CI: −0.11, 0.08; n = 361) and Parkinson’s disease (ERR per 100 mGy: 0.13; 95% CI: −0.26, 0.31; n = 57). Approximately 45% of workers were monitored for beryllium, with a weak non-significant indication of effect modification for lung cancer risk. The RF cohort showed no evidence of a statistically significant increase in mortality from occupational radiation exposure. However, this study was limited by low statistical power, which inhibits the ability to detect effects. Future pooling of Million Person Study (MPS) cohorts will provide further insights, particularly regarding Pu as a carcinogen.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiological Recovery Logistics Tool - 20161

Argonne is building and testing a tool, the Radiological Recovery Logistics Tool (RRLT), that can be used during the response and recovery from a radiological or nuclear incident to effectively allocate appropriate commercial and public works equipment to mitigate, remove, and contain radiological contamination. The requirements for this tool - as well as development of the resulting software - is overseen by a steering committee of stakeholders from DHS's National Urban Security Technology Laboratory (NUSTL), the Federal Emergency Management Agency (FEMA), and the Environmental Protection Agency (EPA). One essential requirement is for RRLT to support the efficient and appropriate allocation of resources for a radiological response. Subsequent discussions between ANL and stakeholders have solidified the nature of this support to include identification of the types of resources to be allocated. The study reported in this paper has both factored fundamental concepts and connections out of this identification process and created a Knowledge Base detailing support goals, response scenarios, and efficacy information on dozens of equipment types. In short, RRLT will dynamically apply these findings to situational conditions surrounding contamination incidents. RRLT's Domain, the model of elements, ideas and relationships with which the tool will work, draws concepts from technical reports and stakeholder vocabularies to connect response goals and scenarios to types of equipment that offer utility towards those goals in those scenarios. RRLT's Knowledge Base will contain details on dozens of equipment types and facilitate the operator's discovery and consumption of these details most pertinent to a dynamically selected subset of goals. The core of its Domain Model is based on a report authored by this team. This report [1] contains a comprehensive list of proposed equipment to accomplish various missions or scenarios that might arise after a large-scale radiological contamination incident in an urban environment or critical infrastructure. The report divides potential response and recovery efforts into five support goals: Survey and monitoring of the contaminated area; Mitigation of received dose to first responders: Decontamination (gross and final) of buildings, vehicles, roadways, parks, and other surfaces: Waste management of solid waste generated during recovery operations: and Containment of wastewater and other waste generated during the response and recovery phases. RRLT's development is driven by use cases. A use case is an intention with which a user approaches the software. Use cases are grouped into delivery increments to schedule development, testing, and presentation to stakeholders. This model partitions the system into seven increments: User Arrival and Authentication, Search and Navigation, Equipment Recommendation, Plan Management, Content Management, and Expanded Access. Once a user 15 authenticated, RRLT will present the user with a dashboard that allows them to explore or search RRLT's content. The dashboard will also include a 'Plan' panel for collecting decisions and relevant observations about an incident at hand to facilitate development of an equipment list. RRLT will offer three general modes of access to items in the knowledge base: - Keyword search for direct discovery of items, - Navigation along predetermined paths from recovery goal towards equipment types, and - Interactive guidance towards equipment types by an autonomous software agent: the Equipment Recommendation Wizard. This presentation will detail progress in the development of the RRLT and also discuss opportunities for those interested in providing feedback on its content and functionality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site 300 B-851 Permit: Radiological Assumptions and Source Term - Air Dispersion Modeling for Radiological Dose Assessment

The following modeling assumptions and source term that is provided in the attachments to this document are meant to serve as a guide to the presentation delivered on April 23rd, 2020, to the San Joaquin Air District Permit Services slides. This analysis is in response to the District’s “Project Incompleteness Letter” (Facility Number: N-472 and Project Number: N-1173492) regarding the potential for depleted uranium (DU) to be resuspended from areas of contaminated soil at Site 300 as a result of high explosive (HE) experiments increased to a requested permitted maximum of 1,000 pound detonations with an annual HE throughput not to exceed 7,500 pounds per year. LLNL has taken every step in the radiological health risk concerns in the modeling assumptions and final source term to be at a level of maximum conservativeness. As an example, forty soil samples were taken in the B-851 area (LLNL-AR-738708 – 2018) and assayed for uranium-234, uranium-235, and uranium-238 concentrations. The maximum uranium soil concentrations were used in the assumptions (potential for resuspended dust occurring from detonation experiments) and not the use of median uranium soil concentrations – a more realistic outcome. Additionally, these uranium soil concentrations were considered to be at 100% uptake in the vegetation for prescribed burns; vegetation uptake factors were not used as that would lower the final source term. This level of conservativeness was maintained throughout the modeling assumptions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Experiments for SINBAD: Evaluation of Oak Ridge Health Physics Research Reactor Operation Data for CAAS Benchmark Creation [Slides]

This report was a real information preservation and dissemination work with a lot of legacy content that was found and used. There was an abundance of uncertainty, discrepancy, and contradictory information. Yet, a detailed, functional SCALE model was built, and the benchmark created is useful for shielding and CAAs validation work. Sulfur fluence C/E ratios are large (2 to 5), so different benchmark metrics were studied. Neutron fluence, element 57 dose, and other dosimetry responses at 3 meters C/E ratios are below 1.5 for bare and steel configurations. Additional promising metrics as dose per unit fluence and steel shield attenuation were computed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The development and use of decision support framework for informing selection of select agent toxins with modelling studies to inform permissible toxin amounts

Many countries have worked diligently to establish and implement policies and processes to regulate high consequence pathogens and toxins that could have a significant public health impact if misused. In the United States, the Antiterrorism and Effective Death Penalty Act of 1996 (Public Law 104-132, 1996), as amended by the Bioterrorism Preparedness and Response Act of 2002 (Public Law 107-188, 2002) requires that the Department of Health and Human Services (HHS) [through the Centers for Disease Control and Prevention (CDC)] establish a list of bacteria, viruses, and toxins that have the potential to pose a severe threat to public health and safety. Currently, this list is reviewed and updated on a biennial basis using input from subject matter experts (SMEs). We have developed decision support framework (DSF) approaches to facilitate selection of select toxins and, where toxicity data are known, conducted modelling studies to inform selection of toxin amounts that should be excluded from select agent regulations. Exclusion limits allow laboratories to possess toxins under an established limit to support their research or teaching activities without the requirement to register with the Federal Select Agent Program. Fact sheets capturing data from a previously vetted SME workshop convened by CDC, literature review and SME input were developed to assist in evaluating toxins using the DSF approach. The output of the DSF analysis agrees with the current select toxin designations, and no other toxins evaluated in this study were recommended for inclusion on the select agent and toxin list. To inform the selection of exclusion limits, attack scenarios were developed to estimate the amount of toxin needed to impact public health. Scenarios consisted of simulated aerosol releases of a toxin in high-population-density public facilities and the introduction of a toxin into a daily consumable product supply chain. Using published inhalation and ingestion median toxic dose (TD 50 ) and median lethal dose (LD 50 ) values, where available, a range of toxin amounts was examined to estimate the number of people exposed to these amounts in these scenarios. Based on data generated by these models, we proposed toxin exclusion values corresponding to levels below those that would trigger a significant public health response (i.e., amounts estimated to expose up to ten people by inhalation or one hundred people by ingestion to LD 50 or TD 50 levels of toxin in the modeled scenarios).

60 APPLIED LIFE SCIENCES↗

A perfused multi-well bioreactor platform to assess tumor organoid response to a chemotherapeutic gradient

There is an urgent need to develop new therapies for colorectal cancer that has metastasized to the liver and, more fundamentally, to develop improved preclinical platforms of colorectal cancer liver metastases (CRCLM) to screen therapies for efficacy. To this end, we developed a multi-well perfusable bioreactor capable of monitoring CRCLM patient-derived organoid response to a chemotherapeutic gradient. CRCLM patient-derived organoids were cultured in the multi-well bioreactor for 7 days and the subsequently established gradient in 5-fluorouracil (5-FU) concentration resulted in a lower IC 50 in the region near the perfusion channel versus the region far from the channel. We compared behaviour of organoids in this platform to two commonly used PDO culture models: organoids in media and organoids in a static (no perfusion) hydrogel. The bioreactor IC 50 values were significantly higher than IC 50 values for organoids cultured in media whereas only the IC 50 for organoids far from the channel were significantly different than organoids cultured in the static hydrogel condition. Using finite element simulations, we showed that the total dose delivered, calculated using area under the curve (AUC) was similar between platforms, however normalized viability was lower for the organoid in media condition than in the static gel and bioreactor. Our results highlight the utility of our multi-well bioreactor for studying organoid response to chemical gradients and demonstrate that comparing drug response across these different platforms is nontrivial.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Inferring relative dose-dependent color center populations in proton irradiated thoria single crystals using optical spectroscopy

In this work, we have utilized photoluminescence spectroscopy and optical ellipsometry to characterize the dose-dependence of the photoluminescence emission intensity and changes in optical absorption of thoria single crystals subject to irradiation with energetic protons at room- and elevated-temperatures. The photoluminescence peaks and the optical absorption bands are attributed to creation of new electronic states emerging from defects resulting from displacement damage. These bands are most likely associated with electrons trapped at the oxygen vacancy sites similar to color centers formed in other irradiated oxides and halides. Our experimental observations are supported by a standard density functional theory calculation of the electronic structure in pristine and oxygen vacancy-bearing thoria crystals. The dose-dependence of the intensity of the photoluminescence peaks is used to parameterize a rate theory model that estimates the concentration of color centers in the irradiated crystals. This parameterization provides optimized migration barrier parameters for oxygen interstitials and vacancies that simultaneously capture the optical response of the crystals irradiated at room- and elevated-temperature. These optical spectroscopy techniques offer a promising pathway to characterize the population of color centers formed at the sites of oxygen anion vacancies, particularly in irradiated nuclear fuels, where atomic-level defects cannot be readily imaged using electron microscopy. When combined with other direct and indirect characterization tools, our approach can provide new insight into defect formation and accumulation in energy materials over single atomic to extended length scales.

36 MATERIALS SCIENCE↗

Heavy-Ion-Induced Lung Tumors: Dose- & LET-Dependence

There is a limited published literature reporting dose-dependent data for in vivo tumorigenesis prevalence in different organs of various rodent models after exposure to low, single doses of charged particle beams. The goal of this study is to reduce uncertainties in estimating particle-radiation-induced risk of lung tumorigenesis for manned travel into deep space by improving our understanding of the high-LET-dependent dose-response from exposure to individual ion beams after low particle doses (0.03 - 0.80 Gy). Female CB6F1 mice were irradiated with low single doses of either oxygen, silicon, titanium, or iron ions at various energies to cover a range of dose-averaged LET values from 0.2 - 193 keV/µm, using 137Cs γ-rays as the reference radiation. Sham-treated controls were included in each individual experiment totally 398 animals across the 5 studies reported. Based on power calculations, between 40 - 156 mice were included in each of the treatment groups. Tumor prevalence at 16 months after radiation exposure was determined and compared to the age-matched, sham-treated animals. Results indicate that lung tumor prevalence is non-linear as a function of dose with suggestions of threshold doses depending on the LET of the beams. Histopathological evaluations of the tumors showed that the majority of tumors were benign bronchioloalveolar adenomas with occasional carcinomas or lymphosarcomas which may have resulted from metastases from other sites.

60 APPLIED LIFE SCIENCES↗

An LSTM Deep Learning Network for ¿Background Radiation Prediction

Determination of appropriate background radiation is important in any measurement application. Environmental radiation monitors and monitors used to assess dose to individuals outside of controlled areas are particularly susceptible to changes in readings due to fluctuations in the environmental conditions. These fluctuations (e.g. radon progeny concentrations) lead to changes in the detector response in the actual radiation environment, and they need to be taken into account when extracting the net operational doses. Work has been ongoing to apply advances in Deep Learning and Artificial Intelligence to account for changes in detector responses based on environmental parameters; in particular, a Long-Short Term Memory (LSTM) Deep Learning architecture has been utilized to incorporate time-series data into a prediction model. In this work, we present the current status of the project to predict radiation measurements based on meteorological conditions and air packet trajectories extracted using the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT4) model.

Degtiarenko, Pavel↗

Orthogonal Gelations to Synthesize Core–Shell Hydrogels Loaded with Nanoemulsion‐Templated Drug Nanoparticles for Versatile Oral Drug Delivery

Hydrophobic active pharmaceutical ingredients (APIs) are ubiquitous in the drug development pipeline, but their poor bioavailability often prevents their translation into drug products. Industrial processes to formulate hydrophobic APIs are expensive, difficult to optimize, and not flexible enough to incorporate customizable drug release profiles into drug products. Here, a novel, dual-responsive gelation process that exploits orthogonal thermo-responsive and ion-responsive gelations is introduced. This one-step “dual gelation” synthesizes core–shell (methylcellulose-alginate) hydrogel particles and encapsulates drug-laden nanoemulsions in the hydrogel matrices. In situ crystallization templates drug nanocrystals inside the polymeric core, while a kinetically stable amorphous solid dispersion is templated in the shell. Drug release is explored as a function of particle geometry, and programmable release is demonstrated for various therapeutic applications including delayed pulsatile release and sequential release of a model fixed-dose combination drug product of ibuprofen and fenofibrate. Independent control over drug loading between the shell and the core is demonstrated. This formulation approach is shown to be a flexible process to develop drug products with biocompatible materials, facile synthesis, and precise drug release performance. This work suggests and applies a novel method to leverage orthogonal gel chemistries to generate functional core–shell hydrogel particles.

60 APPLIED LIFE SCIENCES↗

Atom Probe Tomography Characterization of High-Dose Ion Irradiated MA957

This paper presents a comprehensive characterization study of the microstructural responses to ion irradiation of the oxide dispersion strengthened (ODS) ferritic alloy MA957 using atom probe tomography (APT). The MA957 specimens were irradiated by 1.8 MeV Cr3+ ions to doses and temperatures relevant to advanced fast reactors (100 and 500 dpa at 400-500 °C). The average sizes of the YTiO particles decreased slightly after irradiation at all temperatures, with the most pronounced change at 400 °C. The particle number densities for 400 and 500 °C were slightly below number densities for the unirradiated condition, while the values were slightly higher at 420 and 450 °C. This behavior is consistent with the Nelson-Hudson-Mazey rate theory model that considers the competing effects between recombination and dissolution. An increase in the Y/Ti ratio of the YTiO particles was observed at the two lower temperatures. The formation of Cr-rich precipitates (a') was observed in specimens irradiated at temperatures up to 450 °C. Irradiation-induced segregation on grain boundaries was also investigated. Grain boundary element concentration profiles and ion maps demonstrate differences among the irradiation temperatures, with most datasets differing from the unirradiated condition. A key focus of this ion irradiation study is the high-dose response, and this quantitative assessment revealed relatively small but distinct effects of irradiation on microstructure evolution. Overall, these results showing minor second phase evolution suggest that MA957 should retain mechanical performance generally well up to 500 dpa for the irradiation temperatures studied.

Wang, Jing↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radium Dial Workers: Back to the Future

This report reviews the history of the radium dial workers in the United States, summarizes the scientific progress made since the last evaluation in the early 1990s, and discusses current progress in updating the epidemiologic cohort and applying new dosimetric models for radiation risk assessment. The discoveries of radiation and radioactivity led quickly to medical and commercial applications at the turn of the 20th century, including the development of radioluminescent paint, made by combining radium with phosphorescent material and adhesive. Workers involved with the painting of dials and instruments included painters, handlers, ancillary workers, and chemists who fabricated the paint. Dial painters were primarily women and, prior to the mid to late 1920s, would use their lips to give the brush a fine point, resulting in high intakes of radium. The tragic experience of the dial painters had a significant impact on industrial safety standards, including protection measures taken during the Manhattan Project. The dial workers study has formed the basis for radiation protection standards for intakes of radionuclides by workers and the public. The mortality experience of 3,276 radium dial painters and handlers employed between 1913-1949 is being determined through 2019. The last epidemiologic follow-up was 30 years ago when most of these workers were still alive. Nearly 65% were born before 1920, 37.5% were teenagers when first hired, and nearly 50% were hired before 1930 when the habit of placing brushes in mouths essentially stopped. Comprehensive dose reconstruction techniques are being applied to estimate organ doses for each worker related to the intake of 226Ra, 228Ra, and associated photon exposures. Time dependent dose-response analyses will estimate lifetime risks for specific causes of death. The study of radium dial workers is part of the Million Person Study of low-dose health effects that is designed to evaluate radiation risks among healthy American workers and veterans. Despite being one of the most important and influential radiation effects studies ever conducted, shifting programmatic responsibilities and declining funding led to the termination of the radium program of studies in the early 1990s. Renewed interest and opportunity have arisen. With scientific progress made in dosimetric methodology and models, the ability to perform a study over the entire life span, and the potential applicability to other scenarios such as medicine, environmental contamination and space exploration, the radium dial workers have once again come to the forefront.

61 RADIATION PROTECTION AND DOSIMETRY↗