At least 91 records · Page 5

Root Cause Analysis of Degradation in Protonic Ceramic Electrochemical Cell with Interfacial Electrical Sensors Using Data‐Driven Machine Learning

Abstract Protonic ceramic electrochemical cells (PCECs) offer promising paths for energy storage and conversion. Despite considerable achievements made, PCECs still face challenges such as physiochemical compatibility between componenets and suboptimal solid–solid contact at the interfaces between the electrolytes and electrodes. In this study, a novel approach is proposed that combines in situ electrochemical characterization of interfacial electrical sensor embedded PCECs and machine learning to quantify the contributions of different cell components to total degradation, as well as to predict the remaining useful life. The experimental results suggest that the overpotential induced by the oxygen electrode is 48% less than that of oxygen electrode/electrolyte interfacial contact for up to 1171 h. The data‐driven machine learning simulation predicts the RUL of up to 2132 h. The root cause of degradation is overpotential increase induced by oxygen electrode, which accounts for 82.9% of total cell degradation. The success of the failure diagnostic model is demonstrated by its consistency with degradation modes that do not manifest in electrolysis fade during early real operations. This synergistic approach provides valuable insights into practical failure diagnosis of PCECs and has the potential to revolutionize their development by enabling improved performance prediction and material selection for enhanced durability and efficiency.

25 ENERGY STORAGE↗

Microbial sensor system for monitoring the environment and surfaces

A microbial sensor, system and method that can be used to determine the biochemical conditions of waters, saturated sediments, unsaturated soils, rhizosphere and other environments is disclosed. The flexibility of the microbial sensor design allows for the monitoring of surfaces (skin, ventilation conduits, etc.). An electrochemical microbial sensor system is composed of an indicator electrode(s) and a reference electrode. The reference electrode employs a hydrogen permeable membrane. The electrochemical system is interfaced into a signal/communication module allowing the manual or automated collection of data from field deployments and laboratory investigations. The data is transmitted using various communication technologies including Bluetooth™, cellular, satellite and radio telemetry to cloud-based data management systems. The stored data may be downloaded by users using open-source dashboard and visualization software to image the various environments and/or surfaces investigated.

Burge, Scott R.↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Surface electron modulation of metal oxide‐based electrochemical devices by surface additives—linking sensors and fuel cells

Abstract The interaction between ambient oxygen and the metal oxide surface is central to various electrochemical devices. Solid oxide fuel cell cathodes and semiconducting metal oxide gas sensors are two prominent examples. Parallels between these two systems are highlighted in this perspective. In both cases, the presence of foreign surface species has been found to significantly alter the interactions of the metal oxides’ surfaces with oxygen. On the one hand, interactions are hindered due to the presence of certain impurities, such as the degradation of fuel cell cathode by Si‐species that originate from processing or from operating environments. On the other hand, electrochemically active noble metal additives have been intentionally used to tune the sensor response of metal oxides. In the case of electrochemically active additives, the need for operando spectroscopies to elucidate the mechanism is discussed. Electronic coupling of the surface additive with the metal oxide is found to play a central role in both cases. We use these results to demonstrate that insights gained from either field can be effectively applied to the other.

Materials Science↗

Multielectrode Array Sensors to Enable Long-Duration Corrosion Monitoring and Control of Concentrating Solar Power Systems

Molten mixtures of MgCl2-KCl-NaCl are promising heat transfer fluid (HTF) candidates for the next generation of concentrating solar power systems (Gen3 CSP), because of their low cost, high decomposition temperature, and favorable heat transfer characteristics. However, if the chemistry of the salts is not properly controlled, molten chlorides can cause corrosion of high-temperature metal alloys, such as Inconel (R), in CSP systems. Here we demonstrate a corrosion monitoring system that can be used to monitor the health of the structural alloys over long durations. The monitoring system includes a multielectrode array voltammetry sensor that measures the redox potential of molten MgCl2-KCl-NaCl mixture as well as the presence of corrosion products and impurities. The sensors have been successfully operated in static molten salt environments for long durations, and are capable of detecting corrosion products, such as Cr2+ and Fe2+, quantitatively at low concentrations (i.e., approximately 100 ppm) with less than 4% error.

Concentrated solar power↗

Paper-based gold nanoparticles decorated SWCNTs chemiresistive sensor for sensitive detection of As(III) based on electrochemical doping

A paper-based chemiresistive sensor consisting of a single-walled carbon nanotubes network with electrodeposited gold nanoparticles (AuNPs-SWCNTs) was developed for the sensitive detection of As(III). A new sensing strategy was also proposed combined with a paper-based device for As(III) chemiresistive detection based on the electrochemical doping of As(0) on the AuNPs-SWCNTs channel. Here, the proposed paper-based chemiresistive sensor was manufactured by wax printing and vacuum deposition using a water-based SWCNTs ink. The sensor sensitivity was enhanced by optimizing the volume of SWCNTs ink used in the formation of the sensing network in the paper and the sweep segment of cyclic voltammetry used for the electrochemical deposition of AuNPs. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) to the AuNPs-SWCNTs sensing channel was investigated using a liquid-ion gated FET system. The As(III) concentration detected by the as-fabricated chemiresistive sensor is as low as 1.35 × 10 -5 μM which is even lower than the maximum permissible concentration in drinking water defined by the WHO. In this paper, we provide a simple strategy for developing paper-based chemiresistive sensors with unique properties for practical As(III) determination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection Technologies for Reactive Oxygen Species: Fluorescence and Electrochemical Methods and Their Applications

Reactive oxygen species (ROS) have been found in plants, mammals, and natural environmental processes. The presence of ROS in mammals has been linked to the development of severe diseases, such as diabetes, cancer, tumors, and several neurodegenerative conditions. The most common ROS involved in human health are superoxide (O 2 •-), hydrogen peroxide (H 2 O 2 ), and hydroxyl radicals (•OH). Organic and inorganic molecules have been integrated with various methods to detect and monitor ROS for understanding the effect of their presence and concentration on diseases caused by oxidative stress. Among several techniques, fluorescence and electrochemical methods have been recently developed and employed for the detection of ROS. This literature review intends to critically discuss the development of these techniques to date, as well as their application for in vitro and in vivo ROS detection regarding free-radical-related diseases. Moreover, important insights into and further steps for using fluorescence and electrochemical methods in the detection of ROS are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Structurally Different Yet Functionally Similar: Aptamers Specific for the Ebola Virus Soluble Glycoprotein and GP1,2 and Their Application in Electrochemical Sensing

The Ebola virus glycoprotein (GP) gene templates several mRNAs that produce either the virion-associated transmembrane protein or one of two secreted glycoproteins. Soluble glycoprotein (sGP) is the predominant product. GP1 and sGP share an amino terminal sequence of 295 amino acids but differ in quaternary structure, with GP1 being a heterohexamer with GP2 and sGP a homodimer. Two structurally different DNA aptamers were selected against sGP that also bound GP1,2. These DNA aptamers were compared with a 2'FY-RNA aptamer for their interactions with the Ebola GP gene products. The three aptamers have almost identical binding isotherms for sGP and GP1,2 in solution and on the virion. They demonstrated high affinity and selectivity for sGP and GP1,2. Furthermore, one aptamer, used as a sensing element in an electrochemical format, detected GP1,2 on pseudotyped virions and sGP with high sensitivity in the presence of serum, including from an Ebola-virus-infected monkey. Our results suggest that the aptamers interact with sGP across the interface between the monomers, which is different from the sites on the protein bound by most antibodies. The remarkable similarity in functional features of three structurally distinct aptamers suggests that aptamers, like antibodies, have preferred binding sites on proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemically decorated gold nanoparticles on CVD graphene ChemFET sensor for the highly sensitive detection of As(III)

Here, in this paper, we report a novel reusable receptor-free chemically sensitive field-effect transistor (ChemFET) sensor for the sensitive detection of As(III) using electrochemical doping of Au nanoparticles (AuNPs)-chemical vapour deposition (CVD) graphene (Gr) sensing film (AuNPs-Gr). The sensor consists of a single-gap gold electrode and a single layer of CVD graphene as a conducting/sensing channel decorated with a thin layer of electrochemically deposited AuNPs to catalyze the electroreduction of As(III) ions onto the sensing channel. A new detection strategy was proposed by measuring the resistance change rate of the AuNPs-Gr sensing channel modified between the source electrode and drain electrode, wherein the resistance change was caused by the electrochemical doping of As(0). The results indicated that the electrochemical doping of As(0) onto the sensing channel led to an increase in resistance through the doping interaction among As(0), AuNPs and graphene, enabling the proposed sensor to have an extraordinary detection performance with a high sensitivity. Moreover, the proposed sensor can be recycled by removing the As(0) deposited on the sensing film with the aid of a simple electrochemical oxidization process. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) into the AuNPs-Gr sensing film was investigated using a top liquid gate electrode. The As(III) concentration detected by the AuNPs-Gr ChemFET sensor was as low as 0.001 μg/L, demonstrating that such sensors with a compatible sensing strategy can be used to detect As(III) with high sensitivity, easy fabrication, fast response and can be recycled.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Boosting Electrochemical Catalysis and Nonenzymatic Sensing Toward Glucose by Single‐Atom Pt Supported on Cu@CuO Core–Shell Nanowires

Abstract It is critical to develop high‐performance electrocatalyst for electrochemical nonenzymatic glucose sensing. In this work, a single‐atom Pt supported on Cu@CuO core–shell nanowires (Pt 1 /Cu@CuO NWs) for electrochemical nonenzymatic glucose sensor is designed. Pt 1 /Cu@CuO NWs exhibit excellent electrocatalytic oxidation toward glucose with 70 mV lower onset potential (0.131 V) and 2.4 times higher response current than Cu NWs. Sensors fabricated using Pt 1 /Cu@CuO NWs also show high sensitivity (852.163 µA mM −1 cm −2 ), low detection limit (3.6 µM), wide linear range (0.01–5.18 µM), excellent selectivity, and great long‐term stability. The outstanding sensing performance of Pt 1 /Cu@CuO NWs, investigated by experiments and density functional theory (DFT) calculations, is attributed to the synergistic effect between Pt single atoms and Cu@CuO core–shell nanowires that generates strong binding energy of glucose on the nanowires. The work provides a new pathway for exploring highly active SACs for electrochemical nonenzymatic glucose sensor.

Chemistry↗

Enhanced Laser-Induced Graphene Microfluidic Integrated Sensors (LIGMIS) for On-Site Biomedical and Environmental Monitoring

The convergence of microfluidic and electrochemical biosensor technologies offers significant potential for rapid, in-field diagnostics in biomedical and environmental applications. Traditional systems face challenges in cost, scalability, and operational complexity, especially in remote settings. Addressing these issues, laser-induced graphene microfluidic integrated sensors (LIGMIS) are presented as an innovative platform that integrates microfluidics and electrochemical sensors both comprised of laser-induced graphene. This study advances the LIGMIS concept by resolving issues of uneven fluid transport, increased hydrophobicity during storage, and sensor biofunctionalization challenges. Key innovations include Y-shaped reservoirs for consistent fluid flow, hydrophilic polyethyleneimine coatings to maintain wettability, and separable microfluidic and electrochemical components enabling isolated electrode nanoparticle metallization and biofunctionalization. Multiplexed electrochemical detection of the neonicotinoid imidacloprid and nitrate ions in environmental water samples yields detection limits of 707 nm and 10 -5.4 m with wide sensing ranges of 5–100 µm and 10 -5 –10 -1 m, respectively. Similarly, uric acid and calcium ions are detected in saliva, demonstrating detection limits of 217 nm and 10 -5.3 m with sensing ranges of 10–50 µm, and 10 -5 –10 -2.5 m, respectively. Overall, this biosensing demonstrates the capability of the LIGMIS platform for multiplexed detection in biologically complex solutions, with applications in environmental water quality monitoring and oral cancer screening.

environmental monitoring↗

Tailoring the d-band center on Ru 1 Cu single-atom alloy nanotubes for boosting electrochemical non-enzymatic glucose sensing

The development of cost-effective and highly efficient electrocatalysts is critical to help electrochemical non-enzymatic sensors achieve high performance. Here, in this work, a new class of catalyst, Ru single atoms confined on Cu nanotubes as a single-atom alloy (Ru 1 Cu NTs), with a unique electronic structure and property, was developed to construct a novel electrochemical non-enzymatic glucose sensor for the first time. The Ru 1 Cu NTs with a diameter of about 24.0 nm showed a much lower oxidation potential (0.38 V) and 9.0-fold higher response (66.5 μA) current than Cu nanowires (Cu NWs, oxidation potential 0.47 V and current 7.4 μA) for glucose electrocatalysis. Moreover, as an electrochemical non-enzymatic glucose sensor, Ru1Cu NTs not only exhibited twofold higher sensitivity (54.9 μA mM −1 cm −2 ) and wider linear range (0.5–8 mM) than Cu NWs, but also showed a low detection limit (5.0 μM), excellent selectivity, and great stability. According to theoretical calculation results, the outstanding catalytic and sensing performance of Ru 1 Cu NTs could be ascribed to the upshift of the d-band center that helped promote glucose adsorption. This work presents a new avenue for developing highly active catalysts for electrochemical non-enzymatic sensors.

electrochemistry↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗

Light-triggered electrochemical biosensor using singlet oxygen for self-powered operation and glucose detection

This study introduces a light-activated sensing strategy that integrates photosensitization with electrochemical detection. The sensor employs Eosin Y, a photosensitizer that generates singlet oxygen ( 1 O 2 ) via type II photosensitization. Immobilized within a thin polymer matrix on a carbon working electrode, Eosin Y produces 1 O 2 , under green light (520 nm) illumination, initiating a redox process that yields a measurable current. To incorporate biosensing capabilities and enable self-powered operation, this 1 O 2 – mediated process was coupled with glucose oxidase (GOx) to construct a fully operational glucose biosensor. The addition of glucose reverses the current flow by causing GOx to compete for electrons, with the resulting current magnitude correlating with glucose concentration providing a sensitive measure of glucose. The biosensor, as proof-of-principle, demonstrated excellent performance over a range of glucose concentrations (0–73 mM), achieving a detection limit (LOD) of 2.8 mM for steady state photocurrent under oxygen-saturated conditions. This platform leverages light and 1 O 2 as stimuli for tunable, on-demand signal control, offering a novel approach for adaptive, real-time biosensing technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗