At least 91 records · Page 5

Accurate modeling and inversion of electrical resistivity data in the presence of metallic infrastructure with known location and dimension

Electrical resistivity tomography (ERT) has been widely used in environmental applications to study processes associated with subsurface contaminants and contaminant remediation. Anthropogenic alterations in subsurface electrical conductivity associated with contamination often originate from highly industrialized areas with significant amounts of buried metallic infrastructure. The deleterious influence of such infrastructure on imaging results generally limits the utility of ERT where it might otherwise prove useful for subsurface investigation and monitoring. In this manuscript we present a method of accurately modeling the effects of buried conductive infrastructure within the forward modeling algorithm, thereby removing them from the inversion results. The method is implemented in parallel using immersed interface boundary conditions, whereby the global solution is reconstructed from a series of well-conditioned partial solutions. Forward modeling accuracy is demonstrated by comparison with analytic solutions. Synthetic imaging examples are used to investigate imaging capabilities within a subsurface containing electrically conductive buried tanks, transfer piping, and well casing, using both well casings and vertical electrode arrays as current sources and potential measurement electrodes. Results show that, although accurate infrastructure modeling removes the dominating influence of buried metallic features, the presence of metallic infrastructure degrades imaging resolution compared to standard ERT imaging. However, accurate imaging results may be obtained if electrodes are appropriately located.

imaging↗

Carbon Nanotube Biosensors for Space Molecule Detection and Clinical Molecular Diagnostics

Both space molecule detection and clinical molecule diagnostics need to develop ultra sensitive biosensors for detection of less than attomole molecules such as amino acids for DNA. However all the electrode sensor systems including those fabricated from the existing carbon nanotubes, have a background level of nA (nanoAmp). This has limited DNA or other molecule detection to nA level or molecules whose concentration is, much higher than attomole level. A program has been created by NASA and NCI (National Cancer Institute) to exploit the possibility of carbon nanotube based biosensors to solve this problem for both's interest. In this talk, I will present our effort on the evaluation and novel design of carbon nanotubes as electrode biosensors with strategies to minimize background currents while maximizing signal intensity.The fabrication of nanotube electrode arrays, immobilization of molecular probes on nanotube electrodes and in vitro biosensor testing will also be discussed.

Han, Jie↗

Progress in Development of Electrochemical Methods in Corrosion Science and Engineering

The role and impact of four electrochemical techniques in the study of various corrosion applications are discussed, these are: scanning vibrating electrode technique (SVET), coupled multi-electrode array (CMEA) technique, scanning electrochemical microscope (SECM) and atomic emission spectroelectrochemistry (AESEC). A common theme is an ability to monitor corrosion phenomena in situ on a local electrochemical scale with high resolution of electrochemical and, in some cases, chemical reaction rates. In all cases, the techniques presented here are discussed in the context of specific corrosion problems carried out in full immersion conditions. Examples taken from the current literature, and new data, are presented to demonstrate the use and advantages of these techniques, or a combination of these techniques, as powerful tools for industrially important applications. Here, this includes: assessment of the galvanic interactions and throwing-power of metal-rich primer coatings for active corrosion protection, corrosion/corrosion resistance mechanisms of new metal alloys, the effect of pretreatments on coating integrity, current distributions within a crevice and pitting corrosion.

AESEC↗

Dose-dependent consequences of sub-chronic fentanyl exposure on neuron and glial co-cultures

Fentanyl is one of the most common opioid analgesics administered to patients undergoing surgery or for chronic pain management. While the side effects of chronic fentanyl abuse are recognized (e.g., addiction, tolerance, impairment of cognitive functions, and inhibit nociception, arousal, and respiration), it remains poorly understood what and how changes in brain activity from chronic fentanyl use influences the respective behavioral outcome. Here, we examined the functional and molecular changes to cortical neural network activity following sub-chronic exposure to two fentanyl concentrations, a low (0.01 μM) and high (10 μM) dose. Primary rat co-cultures, containing cortical neurons, astrocytes, and oligodendrocyte precursor cells, were seeded in wells on either a 6-well multi-electrode array (MEA, for electrophysiology) or a 96-well tissue culture plate (for serial endpoint bulk RNA sequencing analysis). Once networks matured (at 28 days in vitro ), co-cultures were treated with 0.01 or 10 μM of fentanyl for 4 days and monitored daily. Only high dose exposure to fentanyl resulted in a decline in features of spiking and bursting activity as early as 30 min post-exposure and sustained for 4 days in cultures. Transcriptomic analysis of the complex cultures after 4 days of fentanyl exposure revealed that both the low and high dose induced gene expression changes involved in synaptic transmission, inflammation, and organization of the extracellular matrix. Collectively, the findings of this in vitro study suggest that while neuroadaptive changes to neural network activity at a systems level was detected only at the high dose of fentanyl, transcriptomic changes were also detected at the low dose conditions, suggesting that fentanyl rapidly elicits changes in plasticity.

59 BASIC BIOLOGICAL SCIENCES↗

Biphasic response of human iPSC-derived neural network activity following exposure to a sarin-surrogate nerve agent

Organophosphorus nerve agents (OPNA) are hazardous environmental exposures to the civilian population and have been historically weaponized as chemical warfare agents (CWA). OPNA exposure can lead to several neurological, sensory, and motor symptoms that can manifest into chronic neurological illnesses later in life. There is still a large need for technological advancement to better understand changes in brain function following OPNA exposure. The human-relevant in vitro multi-electrode array (MEA) system, which combines the MEA technology with human stem cell technology, has the potential to monitor the acute, sub-chronic, and chronic consequences of OPNA exposure on brain activity. However, the application of this system to assess OPNA hazards and risks to human brain function remains to be investigated. In a concentration-response study, we have employed a human-relevant MEA system to monitor and detect changes in the electrical activity of engineered neural networks to increasing concentrations of the sarin surrogate 4-nitrophenyl isopropyl methylphosphonate (NIMP). We report a biphasic response in the spiking (but not bursting) activity of neurons exposed to low (i.e., 0.4 and 4 μM) versus high concentrations (i.e., 40 and 100 μM) of NIMP, which was monitored during the exposure period and up to 6 days post-exposure. Regardless of the NIMP concentration, at a network level, communication or coordination of neuronal activity decreased as early as 60 min and persisted at 24 h of NIMP exposure. Once NIMP was removed, coordinated activity was no different than control (0 μM of NIMP). Interestingly, only in the high concentration of NIMP did coordination of activity at a network level begin to decrease again at 2 days post-exposure and persisted on day 6 post-exposure. Notably, cell viability was not affected during or after NIMP exposure. Also, while the catalytic activity of AChE decreased during NIMP exposure, its activity recovered once NIMP was removed. Gene expression analysis suggests that human iPSC-derived neurons and primary human astrocytes resulted in altered genes related to the cell’s interaction with the extracellular environment, its intracellular calcium signaling pathways, and inflammation, which could have contributed to how neurons communicated at a network level.

59 BASIC BIOLOGICAL SCIENCES↗

Simultaneous electrical recording of cardiac electrophysiology and contraction on chip

Prevailing commercialized cardiac platforms for in vitro drug development utilize planar microelectrode arrays to map action potentials, or impedance sensing to record contraction in real time, but cannot record both functions on the same chip with high spatial resolution. We report a novel cardiac platform that can record cardiac tissue adhesion, electrophysiology, and contractility on the same chip. The platform integrates two independent yet interpenetrating sensor arrays: a microelectrode array for field potential readouts and an interdigitated electrode array for impedance readouts. Together, these arrays provide real-time, non-invasive data acquisition of both cardiac electrophysiology and contractility under physiological conditions and under drug stimuli. Furthermore, we cultured human induced pluripotent stem cell-derived cardiomyocytes as a model system, and used to validate the platform with an excitation–contraction decoupling chemical. Preliminary data using the platform to investigate the effect of the drug norepinephrine are combined with computational efforts. Finally, this platform provides a quantitative and predictive assay system that can potentially be used for comprehensive assessment of cardiac toxicity earlier in the drug discovery process.

59 BASIC BIOLOGICAL SCIENCES↗

Bioelectrochemical crossbar architecture screening platform for extracellular electron transfer

Electroactive microbes can serve as living components in bioelectronic devices, where their unique ability to transfer electrons enables applications in sensing, energy conversion, and synthesis, but they remain challenging to engineer because the bioelectrochemical systems (BESs) used for characterization are low throughput. Here, we present a bioelectrochemical crossbar architecture screening platform (BiCASP) that uses stacked and orthogonally arrayed electrodes to enable individual sample selection for characterization in arrayed formats. This device reports on the current generated by electroactive bacteria on the minute timescale, decreasing the time for data acquisition by several orders of magnitude compared to conventional BESs. This device increases the throughput of screening engineered biological components in cells, identifying mutants of the membrane protein wire MtrA in Shewanella oneidensis that retain the ability to support extracellular electron transfer (EET). BiCASP may be integrated with bioelectronics that need directed evolution of electroactive proteins.

Shewanella↗

One-Step Transfer of Symmetric and Asymmetric Contacts for Large-Scale 2D Electronics and Optoelectronics

Two-dimensional (2D) semiconductors are highly promising candidates for thin-film transistor applications due to their scalability, transferability, atomic thickness, and relatively high carrier mobility. However, a substantial performance gap remains between individual devices based on single-crystalline 2D films and wafer-scale integrated circuits, primarily due to defects introduced during conventional fabrication processes. Here, we report a diamond-assisted electrode transfer technique for the van der Waals integration of wafer-scale prefabricated electrode arrays onto 2D materials, enabling scalable electronics and optoelectronics. Implemented on metal–organic chemical vapor deposition-grown monolayer molybdenum disulfide, this method forms ultraclean metal–semiconductor interfaces, yielding field-effect transistors with excellent ohmic contacts, a low contact resistance of 400 Ω·μm, and a Schottky barrier height of only 9 meV. Furthermore, we demonstrate a scalable transistor array on monolayer molybdenum disulfide with excellent device performance uniformity, achieving an average field-effect mobility of 30 cm 2 V –1 s –1 and an on/off current ratio exceeding 105. Additionally, high photocurrent and responsivity were demonstrated in the array devices, showing their potential for excellent image detection. We further demonstrate the versatility of this technique by fabricating a Schottky diode array through a single-step transfer of asymmetric electrodes─low work function aluminum and high work function gold─onto monolayer tungsten diselenide. This approach provides a clean, effective solution for contact engineering in 2D materials, offering a viable pathway toward wafer-scale, high-performance 2D electronics, optoelectronics, and integrated circuits.

2D electronics↗

Sensor array and apparatus for simultaneous observation of tissue electrophysiology, contractility, and growth

A sensor array for simultaneously measuring electrophysiological responses and contractility responses of a tissue includes: a substrate; a multi-electrode array (MEA) disposed in or on the substrate; and a plurality of interdigitized electrodes (IDEs) disposed in or on the substrate. The MEA and the IDEs are interpenetrating within a plane substantially parallel to an upper surface of the substrate. Systems for measuring such responses using the sensor array may also include contacts and/or connectors for interfacing with external control devices, electrodes, and cell culture components such as a chamber and lid. Fabrication techniques for making such systems include: forming a sensor array comprising an interpenetrating arrangement of IDEs and electrodes of a MEA in or on a substrate surface; forming a plurality of contacts for interfacing the system with one or more external devices in or on the substrate surface; and forming leads between the plurality of contacts and the sensor array.

Qian, Fang↗

Second spatial derivative analysis of cortical surface potentials recorded in cat primary auditory cortex using thin film surface arrays: Comparisons with multi-unit data

Current source density analysis of recordings from penetrating electrode arrays has traditionally been used to examine the layer- specific cortical activation and plastic changes associated with changed afferent input. Here, we report on a related analysis, the second spatial derivative (SSD) of surface local field potentials (LFPs) recorded using custom designed thin-film polyimide substrate arrays.

59 BASIC BIOLOGICAL SCIENCES↗

Potential-induced wetting and dewetting in pH-responsive block copolymer membranes for mass transport control

Wetting and dewetting behavior in channel-confined hydrophobic volumes is used in biological membranes to effect selective ion/molecular transport. Artificial biomimetic hydrophobic nanopores have been devised utilizing wetting and dewetting, however, tunable mass transport control utilizing multiple transport modes is required for applications such as controllable release/transport, water separation/purification and energy conversion. Here, we investigate the potential-induced wetting and dewetting behavior in a pH-responsive membrane composed of a polystyrene-b-poly(4-vinylpyridine) (PS-b-P4VP) block copolymer (BCP) when fabricated as a hierarchically-organized sandwich structure on a nanopore electrode array (NEA), i.e. BCP@NEA. At pH < pK a (P4VP) (pK a ~ 4.8), the BCP acts as an anion-exchange membrane due to the hydrophilic, protonated P4VP cylindrical nanodomains, but at pH > pK a (P4VP), the P4VP domains exhibit charge-neutral, hydrophobic and collapsed structures, blocking mass transport via the hydrophobic membrane. However, when originally prepared in a dewetted condition, mass transport in the BCP membrane may be switched on if sufficiently negative potentials are applied to the BCP@NEA architecture. When the hydrophobic BCP membrane is introduced on top of 2-electrode-embedded nanopore arrays, electrolyte solution in the nanopores is introduced, then isolated, by exploiting the potential-induced wetting and dewetting transitions in the BCP membrane. The potential-induced wetting/dewetting transition and the effect on cyclic voltammetry in the BCP@NEA structures is characterized as a function of the potential, pH and ionic strength. Additionally chronoamperometry and redox cycling experiments are used to further characterize the potential response. The multi-modal mass transport system proposed in this work will be useful for ultrasensitive sensing and single-molecule studies, which require long-time monitoring to explore reaction dynamics as well as molecular heterogeneity in nanoconfined volumes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Principles for Precise Engineering of Sensitivity in Graphene Electrochemical Sensors

Abstract A major difficulty in implementing carbon‐based electrode arrays with high device‐packing density is to ensure homogeneous and high sensitivities across the array. Overcoming this obstacle requires quantitative microscopic models that can accurately predict electrode sensitivity from its material structure. Such models are currently lacking. Here, it is shown that the sensitivity of graphene electrodes to dopamine and serotonin neurochemicals in fast‐scan cyclic voltammetry measurements is strongly linked to point defects, whereas it is unaffected by line defects. Using the physics of point defects in graphene, a microscopic model is introduced that explains how point defects determine sensitivity. The predictions of this model match the empirical observation that sensitivity linearly increases with the density of point defects. This model is used to guide the nanoengineering of graphene structures for optimum sensitivity. This approach achieves reproducible fabrication of miniaturized sensors with extraordinarily higher sensitivity than conventional materials. These results lay the foundation for new integrated electrochemical sensor arrays based on nanoengineered graphene.

Wu, Ting↗

Development of three-dimension microelectrode array for bioelectric measurement using the liquidmetal-micromolding technique

A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics and meet the practical application demands.

36 MATERIALS SCIENCE↗

Capture of Single Silver Nanoparticles in Nanopore Arrays Detected by Simultaneous Amperometry and Surface-Enhanced Raman Scattering

The attoliter volumes and confinement abilities of zero-dimensional nanopore-electrode arrays (NEAs) hold considerable promise for examining the behavior of single nanoparticles. In this work, we use surface-enhanced Raman scattering (SERS) in tandem with amperometry in order to monitor single Ag Raman-sentinel nanoparticles transported to and captured in single nanopores. To that end, highly ordered solid-state NEAs were fabricated to contain periodic arrays of nanopores, each housing a single recessed Au-ring electrode. These were used to electrostatically capture and trap single silver nanoparticles (AgNPs) functionalized with the electrochemically stable Raman reporter, 1,4-bis(2-methylstyryl)benzene (bis-MSB). Transport and capture of the bis-MSB-tagged AgNPs in the nanopores was followed by simultaneous amperometry and SERS signals characteristic of AgNP oxidation and enhanced Raman scattering by bis-MSB at silver–gold hot spots, respectively. The frequency and magnitude of oxidation-current spikes increased with stepwise increases in DC voltage, and characteristic bis-MSB SERS spectra were observed. Under AC excitation, on the other hand, two distinctly different types of SERS signals were observed, independent of frequency and amplitude: (1) strong, transient (<10 s) spectra and (2) slow (>100 s) monotonically diminishing spectra. We hypothesize that the former behavior results from AgNP aggregates, whereas the latter occurs as a result of multiple incomplete AgNP-oxidation events in succession. Here, these results show that attoliter-volume NEAs are competent for acquiring concurrent SERS spectra and for amperometry of single nanoparticles and that together these measurements can illuminate the collision dynamics of nanoparticles in confined environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays

A method has been developed for concentrating, or partly separating, particles of a selected species from a liquid or gas containing these particles, and flowing in a channel. An example of this is to promote an accumulation (and thus concentration) of the selected particle (e.g., biological species such as E. coli, salmonella, anthrax, tobacco mosaic virus or herpes simplex, and non-biological materials such as nano- and microparticles, quantum dots, nanowires, nano - tubes, and other inorganic particles) adjacent to the first surface. Additionally, this method can also determine if the particle species is present in the liquid. This is accomplished by providing an insulating material in an interstitial volume between two or more adjacent nanostructure electrodes. It can also be accomplished by providing a functionalizing substance, located on a selected region of the insulating material surface, which promotes attachment of the selected species particles to the functionalized surface, and measuring a selected electrical property such as electrical impedance, conductance, or capacitance. A time-varying electrical field E, having a root-mean-square intensity of E(sup 2) rms, with a non-zero gradient in a direction transverse to the liquid or fluid flow direction, is produced by a nanostructure electrode array with a very high-magnitude gradient near exposed electrode tips. A dielectrophoretic force causes the selected particles to accumulate near the electrode tips, if the medium and selected particles have substantially different dielectric constants. An insulating material surrounds most of the nanostructure electrodes, and a region of the insulating material surface is functionalized to promote attachment of the selected particle species to the surface. An electrical property value Z(meas) is measured at the functionalized surface, and is compared with a reference value Z(ref) to determine if the selected species particles are attached to the functionalized surface. Some advantages of this innovation are that an array of nanostructure electrodes can provide an electric field intensity gradient that is one or more orders of magnitude greater than the corresponding gradient provided by a conventional microelectrode arrangement, and that, as a result of the high-magnitude field intensity gradients, a nanostructure concentrator can trap particles from high-speed microfluidic flows. This is critical for applications where the entire analysis must be performed in a few minutes

Li, Jun↗

Improved electrochemical performances of CuO nanotube array prepared via electrodeposition as anode for lithium ion battery

Graphical abstract: CuO nanotube array electrodes prepared by electrodeposition method exhibit an excellent lithium ion storage ability as anode of Li-ion battery. - Highlights: • CuO nanotube arrays are synthesized by an electrodeposition method. • CuO nanotube shows a high-rate performance. • CuO nanotube shows an excellent cycling performance. - Abstract: We report a facile strategy to prepared CuO nanotube arrays directly grown on Cu plate through the electrodeposition method. The as-prepared CuO nanotubes show a quasi-cylinder nanostructure with internal diameters of ca. ∼100 nm, external diameters of ca. ∼120 nm, and average length of ∼3 μm. As an anode for lithium ion batteries, the electrochemical properties of the CuO nanotube arrays are investigated by cyclic voltammetry (CV) and galvanostatic charge/discharge tests. Due to the unique nanotube nanostructure, the as-prepared CuO electrodes exhibit good rate performance (550 mAh g{sup −1} at 0.1 C and 464 mAh g{sup −1} at 1 C) and cycling performance (581 mAh g{sup −1} at 0.1 C and 538 mAh g{sup −1} at 0.5 C)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electrostatic generator/motor electrodes located on the inner surface of an electromechanical battery rotor

A geometric design of E-S generator/motor electrodes mounted on the inner surface of a fiber-composite rotor is provided. The electrode configuration is able to sustain very high g levels. The rotor may be formed of carbon-fiber wound on top of an inner E or S-glass fiber composite core. The electrode design provides the needed area to satisfy the power requirements of the storage system and utilizes a stacked wedge-like electrode array that both solves the high-g problem and results in a doubling or tripling of the electrode area, relative to that of electrodes that conform to the inner cylindrical surface of the rotor.

42 ENGINEERING↗

Electrostatic generator/motor electrodes located on the inner surface of an electromechanical battery rotor

A geometric design of E-S generator motor electrodes mounted on the inner surface of a fiber-composite rotor is provided. The electrode configuration is able to sustain very high g levels. The rotor may be funned of carbon-fiber wound on top of an inner E car S-glass fiber composite core. The electrode design provides the needed area to satisfy the power requirements of the storage system and utilizes a stacked wedge-like electrode array that both solves the high-g problem and results in a doubling or tripling of the electrode area, relative to that of electrodes that conform to the inner cylindrical surface of the rotor.