Development of three-dimension microelectrode array for bioelectric measurement using the liquidmetal-micromolding technique

A method of manufacturing three-dimension microneedle electrode arrays is presented in this paper using the micromolding technology with liquid metal at room temperature, based on the physical property of the Bi-In-Sn liquid metal alloy, being its melting point especially low. Observed under scanning electron microscopy, the needle body of the electrode chip manufactured using this method has a good consistency. Skin penetration test in-vitro indicates that the microneedle electrode can pierce the stratum corneum and cross the high-impedance layer to acquire electrical signals. Electrical impedance and polarization voltage experimental results show that the electrode chips have great electric characteristics and meet the practical application demands.

36 MATERIALS SCIENCE↗

Capture of Single Silver Nanoparticles in Nanopore Arrays Detected by Simultaneous Amperometry and Surface-Enhanced Raman Scattering

The attoliter volumes and confinement abilities of zero-dimensional nanopore-electrode arrays (NEAs) hold considerable promise for examining the behavior of single nanoparticles. In this work, we use surface-enhanced Raman scattering (SERS) in tandem with amperometry in order to monitor single Ag Raman-sentinel nanoparticles transported to and captured in single nanopores. To that end, highly ordered solid-state NEAs were fabricated to contain periodic arrays of nanopores, each housing a single recessed Au-ring electrode. These were used to electrostatically capture and trap single silver nanoparticles (AgNPs) functionalized with the electrochemically stable Raman reporter, 1,4-bis(2-methylstyryl)benzene (bis-MSB). Transport and capture of the bis-MSB-tagged AgNPs in the nanopores was followed by simultaneous amperometry and SERS signals characteristic of AgNP oxidation and enhanced Raman scattering by bis-MSB at silver–gold hot spots, respectively. The frequency and magnitude of oxidation-current spikes increased with stepwise increases in DC voltage, and characteristic bis-MSB SERS spectra were observed. Under AC excitation, on the other hand, two distinctly different types of SERS signals were observed, independent of frequency and amplitude: (1) strong, transient (<10 s) spectra and (2) slow (>100 s) monotonically diminishing spectra. We hypothesize that the former behavior results from AgNP aggregates, whereas the latter occurs as a result of multiple incomplete AgNP-oxidation events in succession. Here, these results show that attoliter-volume NEAs are competent for acquiring concurrent SERS spectra and for amperometry of single nanoparticles and that together these measurements can illuminate the collision dynamics of nanoparticles in confined environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved electrochemical performances of CuO nanotube array prepared via electrodeposition as anode for lithium ion battery

Graphical abstract: CuO nanotube array electrodes prepared by electrodeposition method exhibit an excellent lithium ion storage ability as anode of Li-ion battery. - Highlights: • CuO nanotube arrays are synthesized by an electrodeposition method. • CuO nanotube shows a high-rate performance. • CuO nanotube shows an excellent cycling performance. - Abstract: We report a facile strategy to prepared CuO nanotube arrays directly grown on Cu plate through the electrodeposition method. The as-prepared CuO nanotubes show a quasi-cylinder nanostructure with internal diameters of ca. ∼100 nm, external diameters of ca. ∼120 nm, and average length of ∼3 μm. As an anode for lithium ion batteries, the electrochemical properties of the CuO nanotube arrays are investigated by cyclic voltammetry (CV) and galvanostatic charge/discharge tests. Due to the unique nanotube nanostructure, the as-prepared CuO electrodes exhibit good rate performance (550 mAh g{sup −1} at 0.1 C and 464 mAh g{sup −1} at 1 C) and cycling performance (581 mAh g{sup −1} at 0.1 C and 538 mAh g{sup −1} at 0.5 C)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electrostatic generator/motor electrodes located on the inner surface of an electromechanical battery rotor

A geometric design of E-S generator/motor electrodes mounted on the inner surface of a fiber-composite rotor is provided. The electrode configuration is able to sustain very high g levels. The rotor may be formed of carbon-fiber wound on top of an inner E or S-glass fiber composite core. The electrode design provides the needed area to satisfy the power requirements of the storage system and utilizes a stacked wedge-like electrode array that both solves the high-g problem and results in a doubling or tripling of the electrode area, relative to that of electrodes that conform to the inner cylindrical surface of the rotor.

42 ENGINEERING↗

Electrostatic generator/motor electrodes located on the inner surface of an electromechanical battery rotor

A geometric design of E-S generator motor electrodes mounted on the inner surface of a fiber-composite rotor is provided. The electrode configuration is able to sustain very high g levels. The rotor may be funned of carbon-fiber wound on top of an inner E car S-glass fiber composite core. The electrode design provides the needed area to satisfy the power requirements of the storage system and utilizes a stacked wedge-like electrode array that both solves the high-g problem and results in a doubling or tripling of the electrode area, relative to that of electrodes that conform to the inner cylindrical surface of the rotor.

25 ENERGY STORAGE↗

Oriented TiO2 nanotubes as a lithium metal storage medium

A new strategy for suppressing dendritic lithium growth in rechargeable lithium metal batteries is introduced, in which TiO2 nanotube (NT) array electrodes prepared by anodization are used as a metallic lithium storage medium. During the first charge process, lithium ions are inserted into the crystal structure of the TiO2 NT arrays, and then, lithium metal is deposited on the surfaces of the NT arrays, i.e., in the NT pores and between NT walls. From the second cycle onward, the TiO2 material is used as lithium ion pathways, which results in the effective current distribution for lithium deposition and prevents disintegration of the deposited metallic lithium. Compared to a Li(Cu foil)-LiCoO2 cell, the Li(TiO2 NT)-LiCoO2 cell exhibits enhanced cycling efficiency. This new concept will enable other 3D structured negative active materials to be used as lithium metal storage media for lithium metal batteries.

25 ENERGY STORAGE↗

An ECT/ERT dual-modality sensor for oil-water two-phase flow measurement

This paper presents a new sensor for ECT/ERT dual-modality system which can simultaneously obtain the permittivity and conductivity of the materials in the pipeline. Quasi-static electromagnetic fields are produced by the inner electrodes array sensor of electrical capacitance tomography (ECT) system. The results of simulation show that the data of permittivity and conductivity can be simultaneously obtained from the same measurement electrode and the fusion of two kinds of data may improve the quality of the reconstructed images. For uniform oil-water mixtures, the performance of designed dual-modality sensor for measuring the various oil fractions has been tested on representative data and the results of experiments show that the designed sensor broadens the measurement range compared to single modality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zero Resistance Ammetry (ZRA) Measurements of Sediment Electrochemical Gradients, Old Woman Creek, Ohio, USA, June–November 2022

This dataset contains raw and processed zero resistance ammetry (ZRA) measurements collected from wetland sediments at Old Woman Creek, a freshwater estuary on Lake Erie, Ohio, USA, between June and November 2022. Measurements were obtained using a vertically deployed electrode array positioned at multiple depths within the sediment profile to capture electrochemical gradients associated with microbial activity and sediment geochemistry. The raw dataset consists of parsed instrument log files containing timestamps, electrode pair identifiers, and measured electrical potential (mV). The processed dataset includes standardized and quality-controlled values with instrument saturation limits removed and timestamps converted to ISO 8601 format. Electrode line identifiers were mapped to physical depths, enabling interpretation of depth-resolved electrochemical gradients. Instrument saturation values (−2048, −2047, 2047, and 2048 mV) were identified as measurement limits and excluded from quantitative analyses. All data parsing, processing, and quality control steps are documented in an accompanying R Markdown script, ensuring full reproducibility from raw instrument logs to final datasets.

EARTH SCIENCE > AGRICULTURE > SOILS > ELECTRICAL C↗

Impact of pore size, interconnections, and dynamic conductivity on the electrochemistry of vanadium pentoxide in well defined porous structures

Considering the tortuous, random porous nanostructures existing in many battery electrodes, it is essential to understand electronic and ionic behaviors in such a confined nanoscale porous geometry in which electron and ion transports can change dynamically. Here, we have carefully designed three dimensional (3D) interconnected porous electrode structures and performed experiments to probe how the ion and electron transport is impacted within these controlled geometries. By using anodized aluminum oxide as a template, we were able to fabricate both 1D array electrodes and 3D electrodes with varying numbers of interconnections, utilizing vanadium oxide (V 2 O 5 ) as the active material. We demonstrate that the inherent properties of the electrode material in combination with the structural properties of the electrodes can both positively and negatively impact electrochemical characteristics. Most notably, electrodes with seven interconnecting layers in their structure had 19.7% less capacity at 25C than electrodes with zero interconnecting layers, demonstrating the negative effect of interconnections combined with poor electronic conductivity of V 2 O 5 upon lithiation beyond one Li insertion. These results indicate that a careful consideration of the material and structural properties is needed for the design of high performance battery systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field programmable spin arrays for scalable quantum repeaters

The large scale control over thousands of quantum emitters desired by quantum network technology is limited by the power consumption and cross-talk inherent in current microwave techniques. Here we propose a quantum repeater architecture based on densely-packed diamond color centers (CCs) in a programmable electrode array, with quantum gates driven by electric or strain fields. This ‘field programmable spin array’ (FPSA) enables high-speed spin control of individual CCs with low cross-talk and power dissipation. Integrated in a slow-light waveguide for efficient optical coupling, the FPSA serves as a quantum interface for optically-mediated entanglement. We evaluate the performance of the FPSA architecture in comparison to a routing-tree design and show an increased entanglement generation rate scaling into the thousand-qubit regime. Our results enable high fidelity control of dense quantum emitter arrays for scalable networking.

42 ENGINEERING↗

Ion Trapping, Storage, and Ejection in Structures for Lossless Ion Manipulations

Here, a structure for lossless ion manipulation (SLIM) module was constructed with electrode arrays patterned on a pair of parallel printed circuit boards (PCB) separated by 5 mm and utilized to investigate capabilities for ion trapping at 4 Torr. Positive ions were confined by application of RF having alternating phases on a series of inner rung electrodes and by positive DC potentials on surrounding guard electrodes on each PCB. An axial DC field was also introduced by stepwise varying the DC potential of the inner rung electrodes so as to control the ion transport and accumulation inside the ion trap. We show that ions could be trapped and accumulated with 100% efficiency, stored for at least 5 hours with no losses, and could be rapidly ejected from the SLIM trap.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-Time Electrochemical Measurements Of Carbon Steel In Ground Water With Sulfate Reducing Bacteria Enrichment - 15604

A new laboratory system for studying the microbiological corrosion of decommissioning waste was designed and developed during this project. The material in this part of the laboratory studies was carbon steel (AISI/SAE 1005/UNS G10050). In order to estimate the corrosive effects of microbial activity both biotic and abiotic (containing the biocides methyl-isothiazolinone and glutaraldehyde) mesocosms were prepared. To enhance the effects of sulfate reducing bacteria an enrichment of these bacteria isolated from the native drill hole water from the repository site was inoculated in to the biotic mesocosms. Microbiological corrosion was studied using new electrochemical technologies, such as multi-electrode arrays sensors, and molecular biology methods in the laboratory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wafer-scale growth of large arrays of perovskite microplate crystals for functional electronics and optoelectronics

Methylammonium lead iodide perovskite has attracted intensive interest for its diverse optoelectronic applications. However, most studies to date have been limited to bulk thin films that are difficult to implement for integrated device arrays because of their incompatibility with typical lithography processes. We report the first patterned growth of regular arrays of perovskite microplate crystals for functional electronics and optoelectronics. We show that large arrays of lead iodide microplates can be grown from an aqueous solution through a seeded growth process and can be further intercalated with methylammonium iodide to produce perovskite crystals. Structural and optical characterizations demonstrate that the resulting materials display excellent crystalline quality and optical properties. We further show that perovskite crystals can be selectively grown on prepatterned electrode arrays to create independently addressable photodetector arrays and functional field effect transistors. Furthermore, the ability to grow perovskite microplates and to precisely place them at specific locations offers a new material platform for the fundamental investigation of the electronic and optical properties of perovskite materials and opens a pathway for integrated electronic and optoelectronic systems.

36 MATERIALS SCIENCE↗

Long-term non-invasive interrogation of human dorsal root ganglion neuronal cultures on an integrated microfluidic multielectrode array platform

Scientific studies in drug development and toxicology rely heavily on animal models, which often inaccurately predict the true response for human exposure. This may lead to unanticipated adverse effects or misidentified risks that result in, for example, drug candidate elimination. The utilization of human cells and tissues for in vitro physiological platforms has become a growing area of interest to bridge this gap and to more accurately predict human responses to drugs and toxins. The effects of new drugs and toxins on the peripheral nervous system are often investigated with neurons isolated from dorsal root ganglia (DRG), typically with one-time measurement techniques such as patch clamping. Here, we report the use of our multi-electrode array (MEA) platform for long-term noninvasive assessment of human DRG cell health and function. In this study, we acquired simultaneous optical and electrophysiological measurements from primary human DRG neurons upon chemical stimulation repeatedly through day in vitro (DIV) 23. Distinct chemical signatures were noted for the cellular responses evoked by each chemical stimulus. Additionally, the cell viability and function of the human DRG neurons were consistent through DIV 23. To the best of our knowledge, this is the first report on long-term measurements of the cell health and function of human DRG neurons on a MEA platform. Future generations will include higher electrode numbers in customized arrangements as well as integration with different tissue types on a single device. This platform will provide a valuable testing tool for both rodent and human cells, enabling a more comprehensive risk assessment for drug candidates and toxicants.

59 BASIC BIOLOGICAL SCIENCES↗

Old Woman Creek Wetland Sediment and Electrochemical Sensor Microbial Community, 2023

We are developing a technique to monitor microbiological activities referred to as zero resistance ammetry, which entails the deployment of graphite electrodes in sediments. Measurement of current between electrodes of contrasting redox regimes and/or predominant terminal electron accepting processes can be used as an indicator of the extents of microbiological activity. We deployed an electrode array at depths of 2 mm, 4 mm, 76 mm, 78 mm, 152 mm, 154 mm, 227 mm, and 229 mm below the wetland sediment water interface in the Old Woman Creek National Estuarine Research Center, Huron, OH, USA (Lat. = 41.380833, Long. = -82.508889). A core was collected from adjacent sediment and subsamples were collected from depth intervals of 0 – 25 mm, 25 – 127 mm, 127 – 128 mm, and below 178 mm. To determine if the microbial communities attached to the electrodes were reflective of the adjacent sediment-associated microbial community, we conducted a 16S rRNA gene-based (V4 region) survey of these respective materials. This data package contains the results of these surveys, including metadata on the depths from which samples were collected (samples.csv), DNA extraction and sequencing information (OWC_DEPTH_AMPLICON_SEQUENCING_METADATA), sequence processing information (OWC_DEPTH_BIOINFORMATIC_METADATA.csv), an operational taxonomic unit (OTU) table (OWC_DEPTH_97OTUS_TABLE.csv), and nucleotide sequences of OTUs (OWC_DEPTH_97OTUS_SEQS.fasta). All files can be opened using a text-editing application. The fasta file is compatible with bioinformatics applications.

54 ENVIRONMENTAL SCIENCES↗

Real-time Studies of Battery Electrochemical Reactions Inside a Transmission Electron Microscope

We report the development of new experimental capabilities and ab initio modeling for real-time studies of Li-ion battery electrochemical reactions. We developed three capabilities for in-situ transmission electron microscopy (TEM) studies: a capability that uses a nanomanipulator inside the TEM to assemble electrochemical cells with ionic liquid or solid state electrolytes, a capability that uses on-chip assembly of battery components on to TEM-compatible multi-electrode arrays, and a capability that uses a TEM-compatible sealed electrochemical cell that we developed for performing in-situ TEM using volatile battery electrolytes. These capabilities were used to understand lithiation mechanisms in nanoscale battery materials, including SnO 2 , Si, Ge, Al, ZnO, and MnO 2 . The modeling approaches used ab initio molecular dynamics to understand early stages of ethylene carbonate reduction on lithiated-graphite and lithium surfaces and constrained density functional theory to understand ethylene carbonate reduction on passivated electrode surfaces.

25 ENERGY STORAGE↗

An Electrical Resistance Diagnostic for Conductivity Monitoring in Laser Powder Bed Fusion

With the growing interest in metal additive manufacturing using laser powder bed fusion (LPBF), there is a need for advanced in-situ nondestructive evaluation (NDE) methods that can dynamically monitor manufacturing process-related variations, that can be used as a feedback mechanism to further improve the manufacturing process, leading to parts with improved microstructural properties and mechanical properties. Current NDE techniques either lack sensitivity beyond build layer, are costly or time-consuming, or are not compatible for in-situ integration. In this research, we develop an electrical resistance diagnostic for in-situ monitoring of powder fused regions during laser powder bed fusion printing. The technique relies on injecting current into the build plate and detecting voltage differences from conductive variations during printing using a simple, cheap four-point electrode array directly connected to the build plate. A computational model will be utilized to determine sensitivities of the approach, and preliminary experiments will be performed during the printing process to test the overall approach.

36 MATERIALS SCIENCE↗

Innovative Design and Manufacturing of 2.5D Battery with High Energy and Power Density (Final Report)

The goal of this project is to develop cathode inks, to be used in additive manufacturing (AM), that lead to a low-cost, fast manufacturing processes for a new type of non-planar, 2.5D lithium-ion battery (LIB). 2.5D batteries, comprised of a high-aspect-ratio 3D electrode combined with a 2D planar electrode, can simplify the fabrication process because there is no need for the alignment steps seen in traditional 3D batteries. For the success of the two AM processes identified in this project, development of cathode inks is key component because it allows for both platforms to be evaluated in achieving high performance batteries and ease of manufacturing. The two AM processes explored in this project are direct ink writing (DIW) and templating. Both of these processes have been shown to be successful in depositing materials for traditional LIBs and will be used now for the 3D array electrode configuration as part of the 2.5D battery.