Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrolyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Impact of Porous Transport Layer In-Plane Conduction on Spatially Resolved Current and EIS Measurements in a Proton Exchange Membrane Water Electrolyzer

An XY segmented cell was developed for low temperature PEM water electrolysis (PEMWE). The system can assess the local performance by enabling in situ measurements of spatial currents and impedances. In this work, we show through experiments, as well as through modelling work, that the porous transport layer (PTL) must be segmented to eliminate crosstalk. Accurate measurements are only possible when crosstalk is fully eliminated. The XY segmented cell is applied to a case study characterizing the impact of a PTL platinum coating void on spatial performance. The localized performance impact of the coating void is found to be orientation specific: coating voids facing the catalyst layer reduce performance significantly more than coating voids facing the flow field. The results suggest that the tolerances for PTL coating uniformity can be lower at the side facing the flow field. The work showcases the feasibility of the XY segmented cell for impact assessment studies. The presented XY segmented cell enables the characterization of spatial phenomena in PEMWE devices and is envisioned to support modeling efforts and the investigation of manufacturing related tolerances for mass produced PEMWE devices.

08 HYDROGEN↗

Performance and Durability Investigation of Thin, Low Crossover Proton Exchange Membranes for Water Electrolyzers

The goal of this project was to fabricate and study the performance and durability implications of thin, mechanically reinforced membranes containing gas recombination catalysts (GRCs) for advanced proton exchange membrane water electrolysis (PEMWE) systems. The thinner membranes, optimized for a PEMWE environment, dramatically reduced the proton transport resistance across the membrane, improving the overall efficiency of the PEMWE system. At the same time, the GRC technology was deployed to recombine crossover hydrogen from the cathode with oxygen from the anode to form water within the membrane. This reaction mitigated the buildup of hydrogen in the oxygen stream, ensuring safe operation of the PEMWE system. Capabilities to measure the gas crossover in both an ex-situ screening cell and in operando application testing were developed over the course of the project to track membrane progress and quantify deliverables. State of the art roll to roll manufacturing technologies were leveraged to fabricate the membranes on a commercial scale, where the membrane structure was precisely tuned and GRC distributed within the membrane structure.

08 HYDROGEN↗

High‐Concentration Alcohol Generation in Bipolar Membrane CO Electrolyzer

Electrochemical reduction of carbon dioxide and carbon monoxide offers an electricity‐powered route to make multicarbon liquid products. However, in conventional systems employing anion exchange membranes (AEMs), significant liquid product crossover leads to dilute product streams, increasing separation costs; and also produces unwanted anodic oxidation, further decreasing overall efficiency. Here, we report a forward‐biased bipolar membrane (FB‐BPM) system that achieves <10% liquid product crossover while sustaining a highly alkaline environment near the cathode, suppressing ethylene and hydrogen and favoring liquid products. By tuning catalyst composition to modulate the adsorption of *H and *OH, we steer selectivity toward acetate and alcohols. Using the FB‐BPM system, we achieve >25 wt% acetate on CuZn and >15 wt% alcohols on CuSn directly from the cathode outlet stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self‐Standing Carbon Nanofibers@Carbon Felt Electrodes to Boost Electrolyzer Productivity: Application to the Electro‐Manufacturing of trans ‐3‐Hexenedioic Acid and Adipic Acid

The industrial implementation of electrosynthesis for chemical manufacturing remains constrained by the limited surface area of conventional electrodes. Herein, this challenge is addressed by designing a carbon nanofiber@carbon felt (CNF@CF) electrode platform that combines the high conductivity, flexibility, and ease of handling of commercial carbon felts (CF) with the large surface area and tunable surface chemistry of carbon nanofibers (CNFs). CNFs are deliberately grown onto the CF scaffold to form a sword-in-sheath structure, where entangled nanofibers wrap the felt macrofibers to provide excellent mechanical stability and electrical conductivity without binders. CNF@CF is evaluated both as an electrode and as a catalyst support for the electrochemical hydrogenation of cis,cis-muconic acid (ccMA), a biobased platform molecule key to the production of performance polyamides and renewable Nylon 6,6. As a noncatalytic electrode for the partial hydrogenation to trans-3-hexenedioic acid, CNF@CF achieves a threefold increase in both cumulative productivity and Faradaic efficiency (FE) compared to bare CF. A similar boost in catalytic activity and energy efficiency is observed using Pd/CNF@CF for the hydrogenation of ccMA to adipic acid. These results highlight the opportunities of the CNF@CF platform for electro-organic synthesis and sustainable chemical manufacturing.

electrochemical hydrogenation↗

Evaluation of IrO 2 catalysts doped with Ti and Nb at industrially relevant electrolyzer conditions: A comprehensive study

A series of commercial Oxygen Evolution Reaction (OER) IrO 2 -based materials doped with acid-stable titanium and niobium species were comprehensively characterized by Brunauer-Emmett-Teller (BET), X-ray diffraction analysis (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM) with energy dispersive spectroscopy (EDS), and X-ray Scattering. Electrocatalysts were integrated into Membrane Electrode Assembly (MEA) using a fabrication method developed under the US DOE H2NEW consortium. An electrolysis performance in a commercial setup as well as a laboratory screening system was performed at conditions relevant to industrial application. According to the comprehensive characterizations, the studied materials are closer to doped iridium oxides rather than core–shell structures. In an electrolysis cell, the IrO 2 /TiO x catalyst slightly outperforms the IrO 2 /NbO x based on the activity. It was demonstrated that the operation of electrolysis cells at elevated temperatures and the implementation of thinner Nafion-type membranes allows for substantially increased performance, which is consistent with the literature report. Finally, this work provides valuable baselines including characterization and performance for guiding future research in this direction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A guide to performing CO 2 electrolysis in zero-gap electrolyzers

Recent advances in the technology readiness level (TRL) of low-temperature electrochemical CO 2 reduction (eCO2R) have demonstrated that the technology has potential for industrial deployment. However, industrial deployment of eCO2R still requires advances to reach cost parity with existing thermal catalytic pathways. Technoeconomic analysis of eCO2R suggests that research and development will require a decrease in both capital expenditures and operational expenditures to be cost competitive. Here, to decrease the capital expenditures of the system will require increasing the durability to >3 years, while decreasing the operational expenditures will require an increase in energy efficiency due to the cost of electricity being the driving operational cost of a unit.

Energy↗

Liquid Alkaline Water Electrolyzers: Comparing Performance across Design, Operation, and End-of-Life Scenarios

Liquid alkaline water electrolysis (LAWE) is a demonstrated technology for hydrogen production, yet a comprehensive life cycle assessment (LCA) of their deployment is lacking. Research leading to improvements to the core component, the electrochemical stack, along with auxiliary system materials and dynamic operation of stacks from variable electricity supply offers new data that allows for detailed modeling and evaluation. Here, we present an LCA of two facility designs based on the current state-of-the-art stack and an advanced stack with zero-gap between electrodes, and capture dynamic electricity use from solar, wind, and hybrid sources and stack recycling strategies. We present life cycle impact factors characterizing the production of 1 kg of hydrogen across 12 environmental, human health, and resource impact categories (TRACI and ReCiPe) in the contiguous United States. As expected, the source of electricity will drive impacts (e.g., 83-94% of carbon intensity); however, we find that operating using wind electricity can lower hydrogen leakage and the overall carbon intensity (1.03 kgCO 2 e/kgH 2 ) relative to solar electricity (2.57 kgCO 2 e/kgH 2 ) at matched 1:1 capacity between LAWE and the electricity source. The deployment of the advanced design and stack recycling lowers impacts across all life cycle stages. We highlight opportunities to further reduce potential impacts, including the balance of plant materials and operation cycles associated with the use of variable wind and solar electricity that result in hydrogen leakage.

08 HYDROGEN↗

Evaluating the Effects of Anode Porous Transport Layer on the Performance and Durability of Anion Exchange Membrane Electrolyzers

As anion exchange membrane systems have emerged as a competitive low temperature electrolysis technology, research has expanded to other components and device integration. In this study, nickel (Ni) and stainless steel (SS)-based porous transport layers (PTLs) are investigated in membrane electrode assemblies (MEAs). Compared to MEAs using Ni, the SS PTL shows higher performance due to less kinetics and residual loss and possibly due to a combination of iron mobility improving oxygen evolution reactivity and electron conduction pathways, as well as higher porosity increasing site access. Voltage decay rates of approximately 144 and 115 μV/h, respectively, for the Ni and SS PTLs are found, although the long-term durability and lifetime implications are convoluted. Voltage breakdown analysis confirms that both PTLs saw significant increases in residual loss possibly due to catalyst/PTL property changes that affected electronic, ionic, and mass transport pathways. For the Ni PTL, a higher proportion of the losses were due to cell kinetics; comparatively, more of the SS PTL losses were due to increases in the high frequency resistance. The experimental findings presented here provide insights on the impact of the PTL materials and their properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyzer Cost Model

To compare material and electrical costs of different anodes for use in magnesium electrolysis, this interactive sheet is set up to manipulate values for varying configurations of geometry, material properties, and other assumed values.

Nguyen, Tuan (0000000297269764)↗