At least 91 records · Page 5

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗

Engineering Design of D1/D3 Dipole Magnets for the Electron-Ion Collider (EIC)

Here, the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 10 34 cm −2 s −1 . An electron storage ring (ESR) will be installed in the existing Relativistic Heavy Ion Collider (RHIC) tunnel and will store polarized electron beams from 5 to 18 GeV. The ESR will have 750 dipole magnets with varying field requirements, including 576 super-bend triplets consisting of two magnets D1/D3 and D2. This paper presents on the engineering design of the D1/D3 dipole magnets within the arcs, with special focus on the coil design that allows the magnet to be configured for variable ampere-turns per energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation method of beam instability in laser ion source using solenoid

In a laser ion source using solenoid field confinement, it is known that an ion beam becomes unstable in the certain range of a magnetic field. Although it is essential to quantify the instability when discussing the unstable region of the beam, it is difficult to evaluate the beam instability by peak current or the amount of charge because an irregular change of temporal profile occurs in addition to the shot-by-shot fluctuation of amplitude. In this study, I propose the most appropriate method to evaluate the beam instability using the difference from an average waveform. The validity of the new method was evaluated by comparing three evaluation methods (variation of maximum value, variation of integral of waveforms, and the proposed evaluation method) with the experimentally obtained waveforms with the stable and unstable regions of a solenoid field. The proposed method was verified to best represent the beam instability by laser-induced plasma.

43 PARTICLE ACCELERATORS↗

Online multi-objective particle accelerator optimization of the AWAKE electron beam line for simultaneous emittance and orbit control

Multi-objective optimization is important for particle accelerators where various competing objectives must be satisfied routinely such as, for example, transverse emittance vs bunch length. We develop and demonstrate an online multi-time scale multi-objective optimization algorithm that performs real time feedback on particle accelerators. We demonstrate the ability to simultaneously minimize the emittance and maintain a reference trajectory of a beam in the electron beamline in CERN’s Advanced Proton Driven Plasma Wakefield Acceleration Experiment.

43 PARTICLE ACCELERATORS↗

Solenoid actuated driver valve for high repetition rate shock tubes

A high speed, high pressure solenoid actuated valve has been developed for use as a driver section for automated shock tubes. The valve is based on a prior design, and significant improvements in the design of the valve are described in this paper. The new design retains the performance of prior versions of the valve and creates very reproducible reaction conditions in the shock tube, which are illustrated by several thousand experiments. Additionally, the longevity of the valve is improved, failures are reduced, and the maintenance and manufacture of the valve are simplified.

47 OTHER INSTRUMENTATION↗

On the study of hydrodynamic instabilities in the presence of background magnetic fields in high-energy-density plasmas

Blast-wave-driven hydrodynamic instabilities are studied in the presence of a background B-field through experiments and simulations in the high-energy-density (HED) physics regime. In experiments conducted at the Laboratoire pour l’utilisation des lasers intenses (LULI), a laser-driven shock-tube platform was used to generate a hydrodynamically unstable interface with a prescribed sinusoidal surface perturbation, and short-pulse x-ray radiography was used to characterize the instability growth with and without a 10-T B-field. The LULI experiments were modeled in FLASH using resistive and ideal magnetohydrodynamics (MHD), and comparing the experiments and simulations suggests that the Spitzer model implemented in FLASH is necessary and sufficient for modeling these planar systems. These results suggest insufficient amplification of the seed B-field, due to resistive diffusion, to alter the hydrodynamic behavior. Although the ideal-MHD simulations did not represent the experiments accurately, they suggest that similar HED systems with dynamic plasma-β (=2μ0ρv2/B2) values of less than ∼100 can reduce the growth of blast-wave-driven Rayleigh–Taylor instabilities. These findings validate the resistive-MHD FLASH modeling that is being used to design future experiments for studying B-field effects in HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Development of a pulsed, variable-energy positron beam for atomic scale defect studies

Positron annihilation spectroscopy provides a sensitive means of non-destructive characterization of materials, capable of probing single atom vacancies in solids with 10 –7 sensitivity. Here, in this work, we detail the development of a magnetically guided, variable energy, pulsed positron beam designed to conduct depth-dependent defect studies in metals, semiconductors, and dielectrics, which will be the first of its kind in the United States. The design of the target stage provides capabilities for measurements during in situ annealing up to 800 °C and incorporates a new approach to minimize the background due to energetic backscattered positrons. The developed beam at Bowling Green State University provides a powerful tool for characterization of thin films, devices, and ion irradiated materials.

47 OTHER INSTRUMENTATION↗

Radio frequency electrical resistance measurement under destructive pulsed magnetic fields

We developed a resistance measurement using radio frequency reflection to investigate the electrical transport characteristics under destructive pulsed magnetic fields above 100 T. A sample stage consisting of a homemade flexible printed circuit reduced the noise caused by the induced voltage from the pulsed magnetic fields, improving the accuracy of the measurements of the reflected waves. From the obtained reflectance data, the absolute value of the magnetoresistance was successfully determined by analyzing the phase with admittance charts. In conclusion, these developments enable more accurate and comprehensive measurements of electrical resistance in pulsed magnetic fields.

47 OTHER INSTRUMENTATION↗

Impact of mechanical tolerances on partial turn skipping in helical flux compression generator

Maintaining tight mechanical tolerances of the components used in helical flux compression generators is crucial for optimizing device performance. Moving beyond current literature, which provides various approximations for acceptable tolerances, a 3D simulation of the armature stator interaction during generator operation was developed, revealing that existing equations frequently misestimate the tolerance limits. Without restricting the generality of the presented approach, the focus was primarily on the armature’s concentricity and roundness, comparing the acceptable tolerance limits between generators of different sizes. An analytical approach for select geometries was developed, confirming the 3D results. Quantitative results reveal that a steeper Gurney angle and increased winding pitch allow for less restrictive tolerances for eccentricity and ellipticity. Even small deviations from the ideal armature positioning and shape will result in fluctuations of the output current time-derivative, observed experimentally and in simulation. Larger deviations then cause partial turn skipping, associated with loss of magnetic flux. The simulation elucidates the impact of tolerance deviations on generator performance by offering precise tolerance ranges for various generator sizes, thereby facilitating informed design decisions.

42 ENGINEERING↗

Circuit Modeling, Simulation, and Experimental Validation of a 100-kW Polyphase Wireless Power Transfer System for EV Applications

Polyphase wireless power transfer (WPT) systems can achieve much higher surface power densities (kW/m2) and specific power levels (kW/kg) compared to the conventional circular single phase WPT systems. Therefore, polyphase WPT systems can reduce the size, weight, volume, and cost of the WPT systems and can simplify the electric vehicle integration with less demand for space. This study presents the high-performance and compact 100-kW WPT development using polyphase electromagnetic coupling coils with rotating magnetic fields.

Onar, Omer [ORNL] (ORCID:0000000292028857)↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Development and fabrication of a chargeable magnet system for spacecraft control

The design of variable permanent magnets for use in magnetic balancing and control of earth orbiting spacecraft is discussed. These magnets can be used instead of air coils or electromagnets in applications where the objective is to produce, or eliminate, torque on the spacecraft through interaction with the earth's magnetic field. The configuration of the magnet for minimum size and weight is described.

Source record↗

NASDA's activities on vibration isolation technology

The National Space Development Agency's (NASDA) activities in providing various vibration isolation technologies for the Space Station Mission are covered in viewgraph form. Technologies covered include an active vibration isolation system for extra sensitive missions in the low frequency range, a passive damping system consisting of a damping rack for the reduction of resonance amplification, and an isolator for vibration isolation from low frequencies. Information is given in viewgraph form on the active vibration isolation concept, voice coil type electromagnetic suspension, a profile of an active vibration isolation system, a three degree of freedom ground experiment, and acceleration feedback.

Source record↗

Spaceborne centrifugal relays for spacecraft propulsion

Acceleration using centrifugal relays is a recently discovered method for the acceleration of spaceborne payloads to high velocity at high thrust. Centrifugal relays are moving rotors which progressively accelerate reaction mass to higher velocities. One important engineering problem consists of accurately tracking the position of the projectiles and rotors and guiding each projectile exactly onto the appropriate guide tracks on each rotor. The topics of this research are the system kinematics and dynamics and the computerized guidance system which will allow the projectile to approach each rotor with exact timing with respect to the rotor rotation period and with very small errors in lateral positions. Kinematics studies include analysis of rotor and projectile positions versus time and projectile/rotor interactions. Guidance studies include a detailed description of the tracking mechanism (interrupt of optical beams) and the aiming mechanism (electromagnetic focusing) including the design of electromagnetic deflection coils and the switching circuitry.

Ouzidane, Malika↗

Initial Operation of the Nuclear Thermal Rocket Element Environmental Simulator

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility has recently been upgraded such that the power capabilities of the facility have been increased significantly. At its present 1.2 MW power level, more prototypical fuel element temperatures nay now be reached. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during testing In this new higher power configuration, NTREES will be capable of testing fuel elements and fuel materials at near-prototypic power densities. As checkout testing progressed and as higher power levels were achieved, several design deficiencies were discovered and fixed. Most of these design deficiencies were related to stray RF energy causing various components to encounter unexpected heating. Copper shielding around these components largely eliminated these problems. Other problems encountered involved unexpected movement in the coil due to electromagnetic forces and electrical arcing between the coil and a dummy test article. The coil movement and arcing which were encountered during the checkout testing effectively destroyed the induction coil in use at the time and resulted in NTREES being out of commission for a couple of months while a new stronger coil was procured. The new coil includes several additional pieces of support structure to prevent coil movement in the future. In addition, new insulating test article support components have been fabricated to prevent unexpected arcing to the test articles. Additional activities are also now underway to address ways in which the radial temperature profiles across test articles may be controlled such that they are more prototypical of what they would encounter in an operating nuclear engine. The causes of the temperature distribution problem are twofold. First, the fuel element test article is isolated in NTREES as opposed to being in the midst of many other mostly identical fuel elements in a nuclear engine. As a result, the fuel element heat flux boundary conditions in NTREES are far from adiabatic as would normally be the case in a reactor. Second, induction heating skews the power distribution such that power is preferentially deposited near the outside of the fuel element. Nuclear heating, conversely, deposits its power much more uniformly throughout the fuel element. Current studies are now looking at various schemes to adjust the amount of thermal radiation emitted from the fuel element surface so as to essentially vary the thermal boundary conditions on the test article. It is hoped that by properly adjusting the thermal boundary conditions on the fuel element test article, it may be possible to substantially correct for the inappropriate radial power distributions resulting from the induction heating so as to yield a more nearly correct temperature distribution throughout the fuel element.

Emrich, William J., Jr.↗

(abstract) Electromagnetic Compatability Program to Accommodate a Spacecraft Magnetic Search Coil Experiment

A search coil is a very sensitive instrument that measures low frequency magnetic field radiation. In order for the search coil to achieve its objectives, an electromagnetic clean environment must be provided. On a spacecraft, there are many potential sources of low frequency magnetic field emitter. Consequently, a very stringent program is needed to control the emission from these sources. This paper describes the details of such a program.

systems electric motors enclosures shielding↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗