Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗

Reversible phase transformations between Pb nanocrystals and a viscous liquid-like phase

Phase transformations have been a prominent topic of study for both fundamental and applied science. Solid-liquid reaction–induced phase transformations can be hard to characterize, and the transformation mechanisms are often not fully understood. Here, we report reversible phase transformations between a metal (Pb) nanocrystal and a viscous liquid-like phase unveiled by in situ liquid cell transmission electron microscopy. The reversible phase transformations are obtained by modulating the electron current density (between 1000 and 3000 electrons Å –2 s –1 ). The metal-organic viscous liquid-like phase exhibits short-range ordering with a preferred Pb-Pb distance of 0.5 nm. Assisted by density functional theory and molecular dynamics calculations, we show that the viscous liquid-like phase results from the reactions of Pb with the CH 3 O fragments from the triethylene glycol solution under electron beam irradiation. Such reversible phase transformations may find broad implementations.

36 MATERIALS SCIENCE↗

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract

36 MATERIALS SCIENCE↗

Thermochromic displays

Thermochromic materials feasibility for applications in CRT display devices, observing reversible color changes during electron beam irradiation

Burkowski, R. P.↗

Initial comparison of SSPM ground test results and flight data to NASCAP simulations

The satellite surface potential monitor (SSPM) has been developed for the P78-2 SCATHA (Spacecraft Charging At The High Altitudes) satellite to determine the response of selected spacecraft materials to charged-particle environmental fluxes. Since the monitor infers total surface voltages from a single point on the interior side of insulators, a ground simulation program was undertaken to develop analytical techniques to model the monitors and to obtain an experimental calibration of the relationship between the flight measurement techniques and actual measurements. The experimental testing was conducted using monoenergetic electron beams irradiating samples in the dark. An analytical computer model was developed in the NASCAP (NASA Charging Analyzer Program) code. The analytical model material properties for Kapton that controlled backscatter and secondary yield were adjusted to obtain a single set of values that produced reasonable fits for both voltages and currents. The analytical techniques developed in the ground technology investigation have been applied to space flight conditions. Predictions were compared with limited flight data. The agreement is very good indicating that the technique, and NASCAP, can be used to predict spacecraft material charging behavior. Details of the testing, the analytical modelling technique and flight data comparisons are presented.

Stevens, N. J.↗

In-situ TEM investigations of graphic-epitaxy and small particles

Palladium was deposited inside a controlled-vacuum specimen chamber of a transmission electron microscope (TEM) onto MgO and alpha-alumina substrate surfaces. Annealing and various effects of gas exposure of the particulate Pd deposits were studied in-situ by high resolution TEM and electron diffraction. Whereas substrate temperatures of 500 C or annealing of room temperature (RT) deposits to 500 C were needed to obtain epitaxy on sapphire, RT deposits on MgO were perfectly epitaxial. For Pd/MgO a lattice expansion of 2 to 4% was noted; the highest values of expansion were found for the smallest particles. The lattice expansion of small Pd particles on alumina substrates was less than 1%. Long-time RT exposure of Pd/MgO in a vacuum yielded some moblity and coalescence events, but notably fewer than for Pd on sapphire. Exposure to air or oxygen greatly enhanced the particle mobility and coalescence and also resulted in the flattening of Pd particles on MgO substrates. Electron-beam irradiation further enhanced this effect. Exposure to air for several tens of hours of Pd/MgO led to strong coalescence.

Heinemann, K.↗

In Situ Mechanical Property Measurements of Amorphous Carbon-Boron Nitride Nanotube Nanostructures

To understand the mechanical properties of amorphous carbon (a-C)/boron nitride nanotube (BNNT) nanostructures, in situ mechanical tests are conducted inside a transmission electron microscope equipped with an integrated atomic force microscope system. The nanotube structure is modified with amorphous carbon deposited by controlled electron beam irradiation. We demonstrate multiple in situ tensile, compressive, and lap shear tests with a-C/BNNT hybrid nanostructures. The tensile strength of the a-C/BNNT hybrid nanostructure is 5.29 GPa with about 90 vol% of a-C. The tensile strength and strain of the end-to-end joint structure with a-C welding is 0.8 GPa and 5.2% whereas the lap shear strength of the side-by-side joint structure with a-C is 0.25 GPa.

Kim, Jae-Woo↗

Lipid Decontamination Procedures for Life Detection Missions

Molecular biosignatures are key targets for current, proposed, and future life detection missions. With the high accuracy and low limit of detection (LOD) that new and future instruments will require, decontamination of life detection hardware is necessary to prevent false positives. Lipids are a molecular biosignature of interest, as they are ubiquitous to all life as we know it, can survive unaltered in the geologic record for longer than any other biomolecule (i.e. billions of years), and form through both biotic and abiotic processes. Lipids display origin-diagnostic molecular patterns that can reveal biotic or abiotic synthesis, so finding them and ascertaining their molecular features is important for potentially detecting evidence of life elsewhere. Traditional methods of decontamination, or contamination control (CC), primarily clean hardware through fabrication in sterile (cleanroom) environments, killing microbes, and removing/flushing contaminants off instrument and spacecraft components. However, research suggests that some standard cleaning methods are either unlikely to remove lipid contaminants or are incompatible with life detection instrument materials. To solve this problem, I propose to find, test, and verify a decontamination method that thoroughly cleans instruments by destroying lipid molecules, but is simultaneously compatible with major materials used in these instruments. I will study the effects of traditional CC methods (including Dry Heat Microbial Reduction and Vapor phase Hydrogen Peroxide) and experimental CC methods (Electron Beam Irradiation) on lipid molecules for application to life detection instrumentation. I will then develop a CC plan for a novel lipid detector (ExCALiBR, Extractor for Chemical Analysis of Lipid Biomarkers in Regolith) searching for lipids in either soil or icy world scenarios. This plan will uphold planetary protection regulation requirements and validate experimental analyses of in-situ life detection tests.

Decontamination↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Radiation Effects in Used Next Generation Nuclear Fuel Reprocessing Strategies

Given global commitments to significantly increase nuclear energy capacity, it is now more important than ever to develop efficient used nuclear fuel (UNF) management strategies to encourage widespread adoption of closed fuel cycles. To achieve this ambitious goal, a comprehensive understanding of radiation effects is essential for these next generation technologies, as radiolysis often limits longevity and performance. Here, we present new findings on: (i) the radiation robustness and performance of advanced sulfur chloride-based chlorination processes in the presence of nuclear materials (Fig. 1A); and (ii) the impacts of voloxidized uranium and rhenium complexation on monoamide-based UNF direct dissolution strategies (Fig 1B). These studies employed a combination of time-resolved electron pulse and dose accumulation gamma and electron beam irradiation techniques.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Structural Tolerance of Zirconium Diboride under Electron Irradiation through in-situ Convergent Beam Electron Diffraction and Energy-dispersive X-ray Spectroscopy

Zirconium diboride (ZrB 2 ) is a ultra-high temperature ceramic with high melting temperature (>3000 K), super strength and hardness, good thermal conductivity, and excellent resistance to plasma erosion and chemical erosion, being widely applied in hypersonic flight, arc-electrodes, refractory materials, and plasma-facing materials in fusion reactors. Therefore, the structural stability of the material is essential for the applications. Up to now, the material was investigated under neutron irradiation and high-energy ion irradiations. It was reported that the neutron irradiation caused swelling and catastrophic cracking. High-energy ions (30 keV He + ) changed the surface morphology and caused the bright blue and brown colors on ZrB 2 surfaces between 920 K and 1120 K. The electron irradiation tolerance of the material has not been reported yet. Here we used convergent beam electron diffraction (CBED) and energy-dispersive X-ray spectroscopy (EDS) to investigate structural tolerances of ZrB 2 crystals under high-energy electrons at room temperature under vacuum. Finally, the investigation would benefit the understanding of its structural tolerance at microscales.

42 ENGINEERING↗

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

We discuss the need to understand materials exposed to overlapping extreme environments such as high temperature, radiation, or mechanical stress. When these stressors are combined there may be synergistic effects that enable unique microstructural evolution mechanisms to activate. Understanding of these mechanisms is necessary for the input and refinement of predictive models and critical for engineering of next generation materials. The basic physics and underlying mechanisms require advanced tools to be investigated. The in situ ion irradiation transmission electron microscope (I 3 TEM) is designed to explore these principles. To quantitatively probe the complex dynamic interactions in materials, careful preparation of samples and consideration of experimental design is required. Particular handling or preparation of samples can easily introduce damage or features that obfuscate the measurements. There is no one correct way to prepare a sample; however, many mistakes can be made. The most common errors and things to consider are highlighted within. The I 3 TEM has many adjustable variables and a large potential experimental space, therefore it is best to design experiments with a specific scientific question or questions in mind. Experiments have been performed on large number of sample geometries, material classes, and with many irradiation conditions. The following are a subset of examples that demonstrate unique in situ capabilities utilizing the I 3 TEM. Au nanoparticles prepared by drop casting have been used to investigate the effects of single ion strikes. Au thin films have been used in studies on the effects of multibeam irradiation on microstructure evolution. Zr films have been exposed to irradiation and mechanical tension to examine creep. Ag nanopillars were subjected to simultaneous high temperature, mechanical compression, and ion irradiation to study irradiation induced creep as well. These results impact fields including: structural materials, nuclear energy, energy storage, catalysis, and microelectronics in space environments.

47 OTHER INSTRUMENTATION↗

E-Beam Irradiation Beamline at Jefferson Lab for Wastewater Treatment

Electron beam (e-beam) irradiation is an advanced method for removing the emerging organic contaminants in wastewater, such as 1,4-dioxane, and per- and polyfluoroalkyl sub?stances (PFAS), which have the potential to be regulated in the near future but are difficult to degrade by conventional treatment methods. This dissertation was based on a collabo?rating study between Jefferson Lab (Jlab) and Hampton Roads Sanitation District (HRSD) to evaluate the impacts of e-beam irradiation on the degradation of 1,4-dioxane and PFAS. It presents the detailed design of an e-beam irradiation beamline, the beamline simulation using general particle tracer (GPT), the installation, and the successful commissioning. The beamline is an extended section to the Upgraded Injector Test Facility (UITF) at Jlab, which is a continuous wave (CW), superconducting radio frequency (SRF) linear accelerator with an energy up to 10 MeV. To let the sample volume receive a significant and uniform dose distribution, the sample target was designed by investigating the dose distribution simulated with a Monte-Carlo code, FLUKA. The optimized beam energy was 8 MeV and the beam current for irradiation was ? 100 nA. With the use of a solenoid and a raster, the electron beam was expanded to the optimized size, 1? ? 15 mm, at the sample target. This dis?sertation also presents the irradiation experiments for 64 1,4-dioxane samples and 48 PFAS samples in different water matrices, including real wastewater, which were prepared and an?alyzed by HRSD. The absorbed doses of samples were obtained by designing a new method that combines the FLUKA simulation and dose mapping experiments. The irradiation re?sults showed that around 95% of 1,4-dioxane was removed at a low dose of ? 2 kGy, and PFAS was possibly removed at a lower dose compared to similar research. This work is a first implementation of SRF technology for wastewater irradiation. It pro?vides a valuable new research platform for wastewater remediation. This will be in support of future industrial applications of advanced SRF technologies and better understanding of the effect of e-beam irradiation on wastewater or water treatment.

Li, Xi↗

Measurements of particle emission from discharge sites in Teflon irradiated by high energy electron beams

Anomalous behavior of synchronous orbit satellites manifested by overall degradation of system performance and reduced operating life is associated with electrical discharges resulting from differential charging of the spacecraft surface by fluxes of high energy electrons. During a laboratory simulation silver-backed Teflon samples have been irradiated by electron beams having energies in the range 16-26 keV. Charged particles emitted from the resultant electrical discharges have been measured with a biased Faraday cup and retarding potential analyser. Measurements indicate the presence of two distinct fluxes of particles, the first being an early pulse (0-600ns) of high energy (about 7keV) electrons, while the second is a late pulse (1-5 microseconds) of low energy electrons (less than 1eV) and ions (70eV) leaving the discharge site as a quasi plasma. Calculations indicate an electrostatic field as the dominant accelerating mechanism for charged particles.

Hazelton, R. C.↗