Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Scalable stable comb-to-tone integrated RF photonic drive for superconducting qubits

The recent advent of quantum computing has the potential to overhaul security, communications, and scientific modeling. Superconducting qubits are a leading platform that is advancing noise-tolerant intermediate-scale quantum processors. The implementation requires scaling to large numbers of superconducting qubits, circuit depths, and gate speeds, wherein high-purity RF signal generation and effective cabling transport are desirable. Fiber photonic-enhanced RF signal generation has demonstrated the principle of addressing both signal generation and transport requirements, supporting intermediate qubit numbers and robust packaging efforts; however, fiber-based approaches to RF signal distribution are often bounded by their phase instability. Here, we present a silicon photonic integrated circuit-based version of a photonic-enhanced RF signal generator that demonstrates the requisite stability, as well as a path towards the necessary signal fidelity.

47 OTHER INSTRUMENTATION↗

Radiation Hardened Electronics for Reactor Environments

Radiation-hardened (rad-hard) electronics have been the shortcoming in nuclear sensing and instrumentation. Placing advanced sensors and associated electronics closer to a nuclear reactor core will improve reactor control and operation through increased signal accuracy, precision, and fidelity, resulting in safer, more efficient energy production. However, the extreme temperature and bombarding radiation environment of nuclear applications make research and development into electronics and electronic materials technologies essential to enabling improved safety, monitoring, and control of the existing nuclear reactor fleet and the next generation of reactors, including microreactors. To help the US Department of Energy (DOE) define a course for the Office of Nuclear Energy (NE)-funded rad-hard electronics research, Oak Ridge National Laboratory staff present this summary of the state-of-the-art (SOA) technology for the design and implementation of rad-hard electronics and systems, including research efforts and commercial offerings. A collection of technological gaps associated with reactor applications are compiled herein. Based on the radiation degradation mechanisms discussed in this report, along with the state-of-the-art summary survey and a compiled list of gaps, a high-level research plan of future NE funding direction was developed and is provided. This report outlines these activities and provides a summary of SOA electronics technology for rad-hard instrumentation in reactors, a list of the major technology gaps observed, and a draft plan for addressing the present and future needs of reactor instrumentation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-accuracy absolute magnetometry with application to the Fermilab Muon g-2 experiment

We present details of a high-accuracy absolute scalar magnetometer based on pulsed proton NMR. The B-field magnitude is determined from the precession frequency of proton spins in a cylindrical sample of water after accounting for field perturbations from probe materials, sample shape, and other corrections. Features of the design, testing procedures, and corrections necessary for qualification as an absolute scalar magnetometer are described. The device was tested at B = 1.45 T but can be modified for a range exceeding 1–3 T. The magnetometer was used to calibrate other NMR magnetometers and measure absolute magnetic field magnitudes to an accuracy of 19 parts per billion as part of a measurement of the muon magnetic moment anomaly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Critical Need for Innovations in Instruments and Techniques to Enable In-Situ Cold Ion and Cold Electron Measurements within the Magnetosphere

Relatively few studies have focused on the cold plasma populations of the magnetosphere due to difficulties associated with obtaining measurements. The cold particle populations are defined here as those with total energy approximately <100 eV which is an energy range for which measurements are difficult (regardless of species), but which often make up the bulk of the plasma density. These populations have known and suspected impacts on the structure and dynamics of the magnetosphere. Unfortunately, the lack of accurate measurements of the cold ion and cold electron populations through the magnetosphere makes closure of these science questions extremely difficult if not impossible. In a complex system of interconnected parts like the Earth’s magnetosphere, a lack of understanding of one part of the system (the cold electron and ion populations) is disabling. Hence, until cold electron and cold ion measurements are obtained robustly with every mission, the magnetospheric plasma environment cannot be completely understood. This will require innovations in plasma spectrometers and associated techniques required to obtain high-fidelity in-situ measurements of the cold ion and cold electron populations in the magnetosphere. This paper seeks to review the instruments and techniques that have been used to date and present possible options for future missions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bridging Additive Manufacturing and Electronics Printing in the Age of AI

Printing techniques have been instrumental in developing flexible and stretchable electronics, including organic light-emitting diode displays, organic thin film transistor arrays, electronic skins, organic electrochemical transistors for biosensors and neuromorphic computing, as well as flexible solar cells with low-cost processes such as inkjet printing, ultrasonic nozzle, roll-to-roll coating. The rise of additive manufacturing provides even more opportunities to print electronics in automated and customizable ways. In this work, we will review the current technologies of printing electronics (including printed batteries, supercapacitors, fuel cells, and sensors), especially with 3D printing. In this age of ongoing AI revolution, the application of AI algorithms is discussed in terms of combining them with 3D printing and electronics printing for a future with automated optimization, sustainable design, and customizable and scalable manufacturing.

Chemistry↗

Measurements of ion velocity distributions in a large scale laser-produced plasma

Laser-produced plasma velocity distributions are an important, but difficult quantity to measure. In this work, we present a noninvasive technique for measuring individual charge state velocity distributions of laser-produced plasmas using a high temporal and spectral resolution monochromator. The novel application of this technique is its ability to detect particles up to seven meters from their inception (significantly larger than most laboratory plasma astrophysics experiments, which take place at or below the millimeter scale). The design and assembly of this diagnostic is discussed in terms of maximizing the signal to noise ratio, maximizing the spatial and temporal resolution, and other potential use cases. The analysis and results of this diagnostic are demonstrated by directly measuring the time-of-flight velocity of all ion charge states in a laser produced carbon plasma.

47 OTHER INSTRUMENTATION↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Advancing conventional High-Resolution Electron Microscopy

Due to the exceptional performance of most modern commercial transmission electron microscopes, the achievement of phase-contrast imaging resolution in the sub-2Å range is today a routine exercise, provided the samples are compliant. Nonetheless, there remains room for improvement, and the purpose of this manuscript is to highlight procedures that might be employed by the practicing microscopist for advancing conventional high resolution electron microscopy.

440800* -- Miscellaneous Instrumentation-- (1990-)↗

IMPROVED LIFETIME OF A HIGH SPIN POLARIZATION SUPERLATTICE PHOTOCATHODE

Highly spin polarized electron beams are required for the operation of a wide range of accelerators and instruments. The production of such electrons requires the use of Negative Electron Affinity (NEA) activated GaAs-based cathodes operated in photoelectron guns. Because of their extreme sensitivity to poor vacuum conditions the degradation of the photoemission process is so strong that NEA activated GaAs-based photocathodes can only survive in the extreme vacuums typical of DC gun. State-of-the-art on photocathode technology for spin polarized beam productions are summarized. Recent results on the use of robust NEA coating based on the Cs-Te and Cs-Sb leading to improved operational lifetime of a high spin polarization photocathode are reviewed.

47 OTHER INSTRUMENTATION↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction on X-ray output of free electron laser based on artificial neural networks

Abstract Knowledge of x-ray free electron lasers’ (XFELs) pulse characteristics delivered to a sample is crucial for ensuring high-quality x-rays for scientific experiments. XFELs’ self-amplified spontaneous emission process causes spatial and spectral variations in x-ray pulses entering a sample, which leads to measurement uncertainties for experiments relying on multiple XFEL pulses. Accurate in-situ measurements of x-ray wavefront and energy spectrum incident upon a sample poses challenges. Here we address this by developing a virtual diagnostics framework using an artificial neural network (ANN) to predict x-ray photon beam properties from electron beam properties. We recorded XFEL electron parameters while adjusting the accelerator’s configurations and measured the resulting x-ray wavefront and energy spectrum shot-to-shot. Training the ANN with this data enables effective prediction of single-shot or average x-ray beam output based on XFEL undulator and electron parameters. This demonstrates the potential of utilizing ANNs for virtual diagnostics linking XFEL electron and photon beam properties.

47 OTHER INSTRUMENTATION↗