Electron source at the outer boundary of the radiation belts: Storm time case
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Electron bombardment of propellant gas using a mercury ion source
Triode gauge with electron source, electron collector, and positive ion collector made from either graphite or carbon material extends low-pressure ranges of existing gauges by changing only materials used in construction. Advantages of graphite gauge stem from physical properties of graphite (or carbon).
Harnessing the power of the solar wind, an Electric Sail, or E-sail, is a relatively new concept that promises to deliver high speed propellant-less propulsion. The electric sail is an invention made in 2006 at the Kumpula Space Centre in Finland by Pekka Janhunen [Janhunen and Sandroos, 2007]. At its core, an electric sail utilizes multiple positively biased tethers which exchange momentum with solar wind protons via the repelling electric field established around each tether, in other words, by reflecting the solar wind protons. Recognizing the solar wind is a plasma, the effective repelling area of each tether is increased significantly by the formation a plasma sheath around each tether. Fig. 1 shows schematically a spacecraft employing an electric sail. The positive voltage bias (greater than10kV) applied to each tether naturally results in electron collection. Therefore, the electric sail concept necessarily includes an electron source (electron gun) to return collected electrons to space and maintain the positive bias of the tether system.
An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.
An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.
We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project at the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling of 2.5 MeV protons in the presence of intense space-charge. Furthermore, we are constructing an electron source test stand at the University of Chicago which will validate the electrical, thermal, and vacuum characteristics of thermionic sources. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources for electron cooling and the test stand.
We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.