Search NASA⌕ Search

SEARCH · Search NASA

Results for “elution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of engineered sorbents for the sorption of mercury from contaminated bank soils: a column study

Abstract As a global environmental pollutant, mercury (Hg) threatens our water resources and presents a substantial risk to human health. The rate and extent of immobilization of Hg 2+ (hereafter, Hg) on engineered sorbents (Thiol-SAMMS®, pine biochar, SediMite™, Organoclay™ PM-199, and quartz sand as a control) was evaluated using flow-through column experiments. The effectiveness of the sorbents was based on (1) the percentage of Hg removed in relation to the total amount of Hg passing the sorbent column, and (2) the rate of Hg uptake compared to the nonreactive tracer bromide (Br − ). All sorbents removed Hg to a certain extent, but none of the sorbents removed all the Hg introduced to the columns. Thiol-SAMMS showed the highest mean percentage of Hg removed (87% ± 2.9%), followed by Organoclay PM-199 (71% ± 0.4%), pine biochar (57% ± 22.3%), SediMite (61% ± 0.8%), and the control quartz sand (11% ± 5.6%). Thiol-SAMMS was the only sorbent to exhibit retardation of Hg in comparison to the conservative tracer Br − . For the remaining sorbents, Br − along with low concentrations of Hg were eluted within the first 3 pore volumes, indicating limited retardation of Hg. Overall, removal of Hg by sorbents was substantial, suggesting that sorbents might be suitable for deployment in contaminated environments. High concentrations of DOM leaching from the soil columns likely influenced the speciation of Hg and inhibited sorption to the sorbents. Incomplete removal of Hg by any sorbent suggests that additional optimization is needed to increase efficiency.

54 ENVIRONMENTAL SCIENCES↗

Palladium/Zeolite Low Temperature Passive NOx Adsorbers (PNA): Structure-Adsorption Property Relationships for Hydrothermally Aged PNA Materials

Zeolites with different framework structures (SSZ-13, ZSM-5, BEA) but similar Si/Al ratios and Pd loading (~1 wr%) were synthesized and evaluated as low temperature passive NOx adsorbers (PNA). These materials exhibit high NOx adsorption efficiency with atomically dispersed Pd the active adsorption site. Hydrothermal aging at 750 ºC for 16 hours in the presence of 10% water vapor in air resulted in the formation of PdO nanoparticles in all three samples as evidenced by high energy XRD. Hydrothermal aging of the small-pore Pd/SSZ-13 (Si/Al = 6), which contain ~100-90% atomically dispersed palladium ions, decreases its PNA performance only by ~10-20%. High-field solid state 27Al NMR studies on the fresh and aged samples substantiate dealumination and significant changes in the distribution of Al (and thus, Bronsted acid) sites after hydrothermal aging. FTIR measurements with NO probe molecule and titration of Bronsted acid sites with nitrosyl (NO+) ions further corroborate the 27Al NMR data. Because framework aluminum atoms are the anchoring sites for atomically dispersed Pd ions, their elution from the framework causes the loss of active atomically dispersed Pd species. Furthermore, with the aid of HAADF-STEM imaging and synchrotron XRD studies, we further confirm and visualize the fate of these Pd species – they agglomerate into PdO nanoparticles on the external surface of zeolite. Consequently, these changes lead to the decrease in PNA performance of these materials after hydrothermal aging. The thus formed agglomerates cannot be re-dispersed back to their ionic state due to the loss of framework Al T-sites and/or inherent stability of such large PdO particles. Our study clearly demonstrates that, unlike in previous studies that found increased PNA performance upon HTA , high temperatures hydrothermal aging of PNA materials that contain atomically dispersed Pd initially, results in a decrease in NOx storage efficiency due mostly to the formation of PdO agglomerates. However, we also highlight the high hydrothermal stability of predominantly atomically dispersed 1-3 wt% Pd/SSZ-13 (Si/Al = 6), whose performance decreases only marginally after prolonged hydrothermal aging at 750 ºC. Overall, this study shows that hydrothermally stable passive NOx materials can be prepared using small-pore SSZ-13 zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of radium and actinium using zirconia

Herein, zirconia was investigated as a radiation-resistant support for radium and actinium aqueous ion separations. Acetate and total metal ion concentrations were experimentally evaluated as factors that could affect retention using La and Ba surrogates. Pseudo-second order rate constants were derived and the uptake of La was determined to be endothermic. Elution profiles containing Ba, La, 228 Ra, 228 Ac, and 212 Pb are presented and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of hydroxamate-based resins towards a more clinically viable 44 Ti/ 44 Sc radionuclide generator

For this research, several hydroxamate-based resins were synthesized and tested for use in 44 Ti/ 44 Sc generator systems in small scale experiments (740 kBq 44 Ti). The most promising resin was tested further in larger scale generator studies (37 MBq). This resin displayed impressive retention of 44 Ti over several elutions, and high quantities of 44 Sc were obtained in small volumes of dilute HCl eluents. Initial radiolabeling experiments were conducted and demonstrated the possibility of direct radiolabeling of the generator produced 44 Sc with DOTA.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗

Group hexavalent actinide separation from lanthanides using sodium bismuthate chromatography

Advanced used nuclear fuel (UNF) reprocessing strategies are limited by the complex radiochemical separations and engineering required to achieve the separation of actinides (An) from neutron scavenging lanthanides (Ln). The accessibility of the hexavalent oxidation state for the actinides (U – Am) provides a pathway to achieving a group hexavalent actinide separation from the trivalent lanthanides and Cm. The solid oxidant and ion exchanger, sodium bismuthate (NaBiO 3 ), has been demonstrated to quantitatively oxidize and separate Am from trivalent Cm in a column chromatographic system. This work expands on the use of NaBiO 3 chromatography to characterize the adsorption, kinetic, and elution behavior of U, Pu, and Eu. Separation factors over 200 with rapid kinetics were observed at dilute nitric acid concentrations with a complete An/Ln separation achieved in under an hour. In conclusion, the adsorption and chromatographic behavior of key fission products present in various reprocessing raffinates was characterized which demonstrated potential application of a NaBiO 3 -based separation following a TRUEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sulfur-functionalized solid-phase materials for the selective separation of arsenic and selenium

Radioactive arsenic (As) isotopes are of growing interest for applications in nuclear medicine, national security, and environmental research. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have focused on aqueous harvesting of selenium-72,73 ( 72,73 Se) and their daughter isotopes, arsenic-72,73 ( 72,73 As), which are particularly valuable for medical applications and nuclear data studies, respectively. Both conventional isotope production and harvesting methods require chemical separations to purify radioactive As from parent and co-produced Se radioisotopes. While several solid-phase separation methods for As and Se exist, many depend on complex oxidation state control or highly acidic conditions. This study presents results for sulfur-based solid-phase materials selected to enable uptake at lower acidity and eliminate the need for intricate redox chemistry. Specifically, the performance of three covalently bound sulfur-based ligands were evaluated: (1) thiophenol-polystyrene, (2) propanethiol-silica, and (3) thiourea-silica. Uptake characteristics—including distribution coefficients (Dw), kinetics, and column separation behavior—were assessed using 75 Se and 73 As in hydrochloric (HCl) acid and nitric (HNO 3 ) solutions. The resins demonstrated high-yield (>95%) and high-purity As recovery across a range of HCl concentrations. Comparable results in HNO 3 were achieved when combined with anion exchange chromatography. Furthermore, the potential application of these materials for medical isotope generators was also investigated through ligand stability and repeated elution studies. Overall, sulfur leaching from the resins was negligible at the concentrations relevant for these separations but increased with higher acid concentrations.

Arsenic↗

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Here, to assess whether the trihexyl(tetradecyl)phosphonium chloride ([P 66614 + ][Cl - ]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van’t Hoff analysis. All van’t Hoff plots for n-alkanes (C8–C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P 66614 + ][Cl - ] IL was further compared with the [P 66614 + ] bis[(trifluoromethyl)sulfonyl]imide ([P 66614 + ][NTf 2 - ]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28–52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography–mass spectrometry (GC–MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34–40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P 66614 + ][Cl - ] IL providing enhanced separation between polar and aromatic analytes, while the [P 66614 + ][NTf 2 - ] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic–aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P 66614 + ][Cl - ] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P 66614 + ]-based IL stationary phases compared to conventional stationary phase materials.

Chromatographic selectivity↗

Synthetic aromatic kerosene property prediction improvements with isomer specific characterization via GCxGC and vacuum ultraviolet spectroscopy

This research explores an advanced method of fuel composition determination and builds upon typical hydrocarbon group type analyses performed with two-dimensional gas chromatography (GCxGC). In this study, structural information of individual species within Virent’s Synthetic Aromatic Kerosene (SAK) is identified by vacuum ultraviolet (VUV) spectroscopy. By mass, 71.3% of the components elute within six peaks of the chromatogram, from which 12 unique species are identified through a novel deconvolution method. Overall, the identification of 93.6%m across 26 structural isomers is made by the methods described in this work. With 93.6%m ascribed to specific isomers, the precision of fuel property predictions improves dramatically. For example, the absolute error of the viscosity prediction is reduced by 90% because of this advancement in diagnostic capability, and its 95-percentile confidence interval (precision only) is reduced by 93%. Additionally, the properties of SAK, blended with hydro processed esters fatty acids (HEFA), are demonstrated to have blended properties consistent with conventional jet fuel.

10 SYNTHETIC FUELS↗

Separation of cobalt, nickel, and manganese in leach solutions of waste lithium-ion batteries using Dowex M4195 ion exchange resin

Current methods to separate and recover critical metals from waste lithium-ion battery (LIB) scrap require multiple unit operations that involve selective leaching and a combination of separation methods. These methods include impurity removal, solvent extraction, ion exchange, and precipitation, to achieve high purity Co and Ni products. In this paper an efficient extraction strategy was developed to individually separate Ni and Co from a LIB leachate that was generated from an electrochemical leaching process. By using Dowex M4195 resin, as the only method of separation, additional impurity removal operations were not needed. After loading and eluting, three different fractions were obtained: 99.0% Ni concentrate, 98.5% Co concentrate, and a Li/Mn rich concentrate allowing the separation of Ni, Co and Mn. Here, the developed process is then presented as an alternative for metal recovery from leachates from scrap LIBs with minimum chemical addition and pH adjustment.

36 MATERIALS SCIENCE↗

Chemical-Free Lithium Separation from High-Salinity Brines Using Model-Informed and Machine Learning-Optimized Multi-Column Zwitterionic Chromatography

Direct Lithium Extraction (DLE) technologies often struggle to produce high-purity lithium salts from high-salinity brines, as current approaches require chemical-based elution, regeneration, and precipitation steps, resulting in significant environmental footprints. A novel salt fractionation approach using carboxybetaine resin, known as zwitterionic chromatography (ZIC), has demonstrated that lithium ions can be separated from divalent cations under high-salinity conditions using only water as eluent, with no regeneration required. To enable continuous and scalable deployment of this approach, we developed a chemical-free Multi-column Zwitterionic Chromatography (MZC) process and its theoretical and process models. To predict and optimize this nontraditional separation system, we introduced a novel anti-Langmuir isotherm, and the isotherm parameters were estimated through a machine learning-driven optimization based on artificial neural network ensembles with numerical feasibility assessment. Using machine learning-driven optimization, the MZC process achieved 98.0% lithium recovery, 99.5 % Li/(Li + Mg + Ca) purity, a 31.3% productivity increase, and a 33% reduction in water use compared to batch operation. The proposed MZC process enables lithium separation at $0.6-1.2 kg-1 Li, with costs dominated by resin manufacturing, while offering lower separation costs and carbon footprint compared with conventional carbonation. Overall, these findings position the MZC process as an effective polishing step within scalable and sustainable lithium production pipelines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical review of functionalized silica sorbent strategies for selective extraction of rare earth elements from acid mine drainage

We report the ubiquitous and growing global reliance on rare earth elements (REEs) for modern technology and the need for reliable domestic sources underscore the rising trend in REE-related research. Adsorption-based methods for REE recovery from liquid waste sources are well-positioned to compete with those of solvent extraction, both because of their expected lower negative environmental impact and simpler process operations. Functionalized silica represents a rising category of low cost and stable sorbents for heavy metal and REE recovery. These materials have collectively achieved high capacity and/or high selective removal of REEs from ideal solutions and synthetic or real coal wastewater and other leachate source. These sorbents are competitive with conventional materials, such as ion exchange resins, activated carbon; and novel polymeric materials like ion-imprinted particles and metal organic frameworks (MOFs). This critical review first presents a data mining analysis for rare earth element recovery publications indexed in Web of science, highlighting changes in REE recovery research foci and confirming the sharply growing interest in functionalized silica sorbents. A detailed examination of sorbent formulation and operation strategies to selectively separate heavy (HREE), middle (MREE), and light (LREE) REEs from the aqueous sources is presented. Selectivity values for sorbents were largely calculated from available figure data and gauged the success of the associated strategies, primarily: (1) silane-grafted ligands, (2) impregnated ligands, and (3) bottom-up ligand/silica hybrids. These were often accompanied by successful co-strategies, especially bite angle control, site saturation, and selective REE elution. Recognizing the need to remove competing fouling metals to achieve purified REE “baskets,” we highlight techniques for eliminating these species from acid mine drainage (AMD) and suggest a novel adsorption-based process for purified REE extraction that could be adapted to different water systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fractionation of critical metals from authentic acid mine drainage using a multi-bed immobilized amine sorbent setup: A field site study

Here for the first time reported, a flow-through multi-fixed bed immobilized amine/silica sorbent strategy was employed to fractionate purified critical metals from authentic acid mine drainage (AMD). The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory’s (NETL) patent-pending Multi-functional Sorbent Technology (MUST) sorbents were used to recover critical metals from AMD at the Pittsburgh Botanic Garden (Pittsburgh, PA USA). By adjusting the AMD/sorbent ratio, we recovered > 80% of pure adsorbed Mn (by adsorbed metal weight) and >90% pure adsorbed Al at lab-scale. Further optimizing the weight hourly space velocity (WHSV) enhanced the rate of adsorbed Al recovery by over five times, justifying a field site test. After treating >100 L of AMD at the field site, the optimized polyamine/epoxysilane/aminosilane sorbent recovered approximately 0.7 wt% adsorbed Al at > 90% purity. A tangible amount of purified aluminum hydroxide [Al(OH) 3 ] and aluminum sulfate [Al 2 (SO 4 ) 3 ] solids were then recovered after eluting and precipitating the previously adsorbed metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production, isolation, and shipment of clinically relevant quantities of astatine-211: A simple and efficient approach to increasing supply

The alpha emitter astatine-211 ( 211 At) is a promising candidate for cancer treatment based on Targeted Alpha (α) Therapy (TAT). A small number of facilities, distributed across the United States, are capable of accelerating α-particle beams to produce 211 At. However, challenges remain regarding strategic methods for shipping 211 At in a form adaptable to advanced radiochemistry reactions and other uses of the radioisotope. Purpose: Our method allows shipment of 211 At in various quantities in a form convenient for further radiochemistry. Procedures: For this study, a 3-octanone impregnated Amberchrom® CG300M resin bed in a column cartridge was used to separate 211 At from the bismuth matrix on site at the production accelerator (Texas A&M) in preparation for shipping. Aliquots of 6 M HNO 3 containing up to ≈2.22 GBq of 211 At from the dissolved target were successfully loaded and retained on columns. Exempt packages (<370 MBq) were shipped to a destination radiochemistry facility, University of Texas MD Anderson Cancer Center, in the form of a convenient air-dried column. Type A packages have been shipped overnight to University of Alabama at Birmingham. Main findings: Air-dried column hold times of various lengths did not inhibit simple and efficient recovery of 211 At. Solution eluted from the column was sufficiently high in specific activity to successfully radiolabel a model compound, 4-(4,4,5,5-tetramethyl-1,3,2-dioxaborolan-2-yl)aniline (1), with 211 At. The method to prepare and ship 211 At described in this manuscript has also been used to ship larger quantities of 211 At a greater distance to University of Alabama at Birmingham. Principal conclusions: The successful proof of this method paves the way for the distribution of 211 At from Texas A&M University to research institutions and clinical oncology centers in Texas and elsewhere. Finally, use of this simple method at other facilities has the potential increase the overall availability of 211 At for preclinical and clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An electrochemical generator for the continual supply of 213 Bi from 225 Ac for use in targeted alpha therapy applications

Bismuth-213 is a radionuclide of interest for targeted alpha therapy and is supplied via a radiochemical generator system through the decay of 225 Ac. Radionuclide generators employ longer lived “parent” radionuclides to routinely supply shorter-lived “daughter” radionuclides. The traditional 225 Ac/ 213 Bi radiochemical generator relies on an organic cation exchange resin where 225 Ac binds to the resin and 213 Bi is routinely eluted. These resins degrade when they absorb large doses of ionizing radiation (>1 × 10 6 Gy/mg), which has been observed when the loading activity of 225 Ac exceeds 2.59*10 9 Bq (70 mCi). Herein we report the development of an electrochemical generator for the supply of 213Bi that has the potential to overcome this limitation. Bismuth-213 spontaneously electrodeposits onto nickel foils in 0.1 M hydrochloric acid at 70 °C. Using this method, we were able to plate an average of 73 ± 4 % of the 213 Bi in solution and obtain a final 213 Bi recovery of 65 ± 8 % in 0.1 M citrate pH 4.5 via reverse electrolysis using titanium as the cathode. The recovered 213Bi had an average radiochemical purity of >99.8 % and was successfully used to radiolabel DOTATATE with an average radiochemical yield of 85.1 % (not optimized).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exosomes secreted from mesenchymal stem cells mediate the regeneration of endothelial cells treated with rapamycin by delivering pro-angiogenic microRNAs

Highlights: • MSC-derived exosomes play an important role in promoting endothelial regeneration treated with rapamycin in vitro. • A distinct class of exosomal miRNAs is identified to be tightly related to endothelial regeneration. • The therapeutic effects of MSC-exosomes may be ascribed to the delivery of pro-angiogenic miRNAs to endothelial cells. • MSC-exosomes may serve as a cell-free therapy for clinical treatment of delayed endothelial healing after DES implantation. Delayed endothelial healing after drug eluting stent (DES) implantation is a critical clinical problem in treatment of coronary artery diseases. Exosomes exhibit proangiogenic potential in a variety of ischemic diseases. However, the association of exosomes with endothelial regeneration after DES implantation has been rarely reported. In this study, we aimed to investigate the therapeutic effects of mesenchymal stem cell (MSC)-derived exosomes on endothelial cells treated with rapamycin and explore the potential mechanisms of MSC-derived exosomes in promoting endothelial regeneration. Exosomes were isolated from MSCs by ultracentrifugation and identified by transmission electron microscopy, nanoparticle tracking analysis, and Western blot assay. The in vitro effects of MSC-derived exosomes on the proliferation and migration of endothelial cells treated with rapamycin were evaluated by integrated experiment, cell counting kit-8, scratch, tube formation, and transwell assays. And the apoptosis of rapamycin-induced endothelial cells loaded with MSC-derived exosomes was detected using TUNEL and Annexin-V FITC and PI double-staining assays. The microRNA (miRNA) cargo of MSC-derived exosomes was identified by high-throughput RNA sequencing. Pro-angiogenic miRNAs and key pathways were further characterized. Our results indicated that MSC-derived exosomes could be ingested into umbilical vein endothelial cells (HUVECs) and significantly enhanced cell proliferation rate, migratory and tube-forming capabilities in vitro. MSC-derived exosomes also inhibited the apoptosis of HUVECs induced by rapamycin. A distinct class of exosomal miRNAs was further identified, including six miRNAs tightly related to neovasculogenesis. Silencing the expression of exosomal miRNA-21–5p and let-7c-5p attenuated the pro-proliferative and pro-migratory capacity of MSC-derived exosomes. Moreover, functional enrichment analysis indicated that metabolic pathways might contribute to reendothelialization. This study highlights a proregenerative effect of MSC-derived exosomes in vitro, which may be partly explained by the delivery of pro-angiogenic miRNAs to endothelial cells.

60 APPLIED LIFE SCIENCES↗

Radiolabeling and in vitro studies of scandium-44 with HOPO chelator for PET imaging

44 Sc has been attracting interest as a clinically viable PET (positron emission tomography) imaging radionuclide due to its high positron branching ratio, 3.97 hour half-life, ideal positron energy of 632 keV and ability to be produced from a generator as well as from a cyclotron. Scandium is also of interest since the coordination is similar to the lanthanides and Ga 3+ that have demonstrated labeling methods. Further, 47 Sc (a potential therapeutic radionuclide) can serve as a matched isotope pair for theranostic applications. While the labeling studies of 44 Sc with DOTA and DOTA derivatives are quite extensive, there is little data on complexation of scandium with the chelator 3,4,3-(LI-1,2-HOPO). This ligand has been used successfully to radiolabel 89 Zr where it was shown to have high stability in vivo. Additionally, preliminary studies with 86 Y, and non-radioactive scandium show promising complexation constants similar to those found with DOTA derivatives. One major advantage of using HOPO is that radiolabeling can be achieved at room temperature while DOTA requires elevated temperatures, that may be detrimental when radiolabeling biomolecules. Radiolabeling of generator produced 44 Sc versus cyclotron produced 44 Sc is also under investigation as there are currently several different post-elution purification methods of generator 44 Sc, and the potential radiolabeling complications of these eluents has not yet been studied. This work focuses on radiolabeling HOPO with generator produced 44 Sc and the in vitro and radioanalytical evaluation of the resulting complexes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗