Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy consumption model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Simulation-Based Assessment of Energy Consumption of Alternative Powertrains in Agricultural Tractors

The objectives of this research were to develop simulation models for agricultural tractors with different powertrain technologies and evaluate the energy consumption in typical agricultural operations. Simulation models were developed for conventional, parallel hybrid electric, series hybrid electric, fuel cell hybrid, and battery electric powertrains. Autonomie vehicle simulation software (version 2022) was used for the simulations and the tractor models were simulated in two tilling cycles and in a road transport cycle with a trailer. The alternative powertrains were configured to have at least the same tractive performance as the conventional, diesel engine-powered tractor model. The simulation results showed that the potential of the parallel and series hybrid powertrains to improve energy efficiency depends heavily on the tractor size and the operating cycle conditions. The fuel cell hybrid and battery electric powertrains have a higher potential to reduce energy consumption and emissions but still have inherent technical challenges for practical operation. The battery-powered electric tractor would require improvements in the storage energy density to have a comparable operational performance in comparison to other powertrains. The fuel cell hybrid tractor already provided an adequate operating performance but the availability of hydrogen and refueling infrastructure could be challenging to resolve in the farming context.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock: Commercial Building Stock Energy Consumption Dataset

The commercial building sector stock model, or ComStock, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States.

building↗

Brownian bridge-based speed imputation technique for truck energy consumption and emissions estimation

The available truck Global Positioning System (GPS) data, typically collected with large time gaps, rely on imputation techniques to obtain second-by-second data that are required in models for estimating truck energy consumption and emissions. However, existing speed imputation techniques either require a large amount of high-resolution data for model training or rely on special movement assumptions. Here, to fill the gap and effectively apply the low-resolution truck GPS datasets, this paper proposes a simple imputation technique that adopts the Brownian bridge structure to impute missing speed data. The proposed technique introduces a feasible imputation region and a combined drift into the imputation procedure to capture vehicle acceleration constraint, travel distance constraint, and speed volatility. The calibrated model is applied to a set of low-resolution truck GPS data. The results demonstrate the robustness of the proposed technique in enhancing estimation accuracy when using low-resolution GPS data to estimate fuel consumption and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RouteE API

This is the API endpoint for RouteE energy prediction, which can be used to get both single vehicle link or route energy estimates and transportation network-wide energy consumption estimates for a variety of vehicles. This enables external researchers and transportation engineers to access and utilize NLR's growing library of pre-trained vehicle models for prediction of transportation energy consumption. This API provides three endpoints: - /route: Energy estimation of a vehicle over a planning link or sequence of links (route). - /network: Network-wide estimation of energy consumption for all vehicle traffic in the desired area. - /compass: Energy-optimal “eco-routing” between input origin and destination coordinates (Currently in beta for Denver metro area only).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-dimensional Data-driven Energy optimization for Multi-Modal Transit Agencies (HD-EMMA) (Final Technical Report)

Public bus transit services in the U.S. are responsible for at least 19.7 million metric tons of CO 2 emission annually. Electric vehicles (EVs) can have a much lower environmental impact than comparable internal combustion engine vehicles (ICEVs), especially in urban areas. Unfortunately, EVs are also much more expensive than ICEVs. As a result, many public transit agencies can afford only mixed fleets of transit vehicles, consisting of EVs, hybrids (HEVs), and ICEVs. Transit agencies that operate such mixed fleets of vehicles face a challenging optimization problem: these agencies need to decide which vehicles are assigned to serving which transit trips. Since the advantage of EVs over ICEVs varies depending on the route and time of day (e.g., the benefit of EVs is higher in slower traffic with frequent stops and lower on highways), the assignment can have a significant effect on energy use and, hence, environmental impact. Through this project, we have developed reference data about energy collections and constructed a set of machine learning models that can accurately predict the energy consumption for the whole fleet at the level of each trip. We have used these models to develop a scheduling and assignment strategy that can rotate the different vehicle types across the transit agencies’ routes. The optimization algorithm ensures that the vehicles are matched to trips considering weather patterns, expected congestion, and road gradients to minimize the overall energy usage. We list the key observations from our project for other practitioners below. Details are available in the report, and the list of source code and our publications are included in the appendix. 1. We have demonstrated the feasibility of collecting, merging and analyzing large volumes of high-resolution real-world telemetry data from a mixed vehicle fleet. To mitigate the inherent noise of the recorded GPS points, the team developed an algorithm that filters data and maps the points onto a street. The algorithm considers previous and subsequent location measurements and different characteristics of nearby streets to determine how likely the vehicle travels on them. Then, the team segmented the time series into disjoint contiguous samples based on adjacent road segments and repeated the outlier detection and removal. For each data point, the team added features corresponding to elevation changes within the samples, weather features, such as temperature, and traffic data, such as speed ratio between actual speed and free-flow speed. 2. We have developed two forms of machine learning models that be used to understand and analyze the energy operations of a mixed vehicle transit fleet. The micro prediction model provides estimates of instantaneous energy prediction for all types of buses (diesel, hybrid, and electric). Such a model is important in evaluating the energy impacts of real-time bus operation strategies, but it is challenging due to diversified driving cycles of transit buses. The model can help the drivers understand the impact of their driving behaviors and short-term congestions. The macro prediction models estimate average energy consumption across the whole trip considering the features: distance traveled, various road-type features, elevation change, day of the week, time of day, various weather features (temperature, humidity, etc.), and traffic features (speed ratio and jam factor). 3. We have demonstrated that it is possible to transfer the machine learning models we have developed in this project to other teams and cities by using inductive transfer learning. We also showed that the performance of the macro energy prediction models can be improved using a multi-task learning approach where the learning parameters are shared between the models being developed for different vehicle types. The advantage of this approach is improved learning performance as the models can exploit common spatio-temporal and environmental characteristics. 4. Finally, we have developed trip and vehicle assignment and scheduling algorithms that use the energy prediction models and develop a trip to vehicle type (diesel, electric, hybrid) assignment for the whole operation to reduce overall emissions and cost. We have shown through simulations that the proposed algorithms can save $\$$ 48,910 in energy costs and 175 metric tons of CO 2 emission annually for CARTA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Depot Charging Schedule Optimization for Medium- and Heavy-Duty Battery-Electric Trucks

Charge management, which lowers charging costs for fleets and prevents straining the electrical grid, is critical to the successful deployment of medium- and heavy-duty battery-electric trucks (MHD BETs). This study introduces an energy demand and cost management framework that optimizes depot charging for MHD BETs by combining an energy consumption machine learning model and a linear program optimization model. The framework considers key factors impacting real-world MHD BET operations, including vehicle and charger configurations, duty cycles, use cases, geographic and climate conditions, operation schedules, and utilities’ time-of-use (TOU) rates and demand charges. The framework was applied to a hypothetical fleet of 100 MHD BETs in California under three different utilities for 365 days, with results compared to unmanaged charging. The optimized charging solution avoided more than 90% of on-peak charging, reduced fleet charging peak load by 64–75%, and lowered fleet energy variable costs by 54–64%. This study concluded that the proposed charge management framework significantly reduces energy costs and peak loads for MHD BET fleets while making recommendations for fleet electrification infrastructure planning and the design of utility TOU rates and demand charges.

Song, Shuhan↗

Retrofit Energy Analysis and Central Thermal modeling (REACT) v1.0

REACT is a website designed to simplify the analysis and decision-making process for retrofitting existing central plant heating and cooling systems with advanced heat pump technologies. The tool evaluates the technical and economic viability of replacing traditional boilers with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. Retrofitting traditional boiler and chiller systems with water-to-water or air-to-water heat pumps can significantly reduce energy consumption and lower lifecycle costs. The REACT provides: User-Friendly Tools: A user friendly web interface for quick, intuitive analysis accessible to non-experts. Advanced Modeling: A Python-powered engine for detailed parametric studies, optimization, and research applications. Comprehensive Analysis: Lifecycle cost evaluation, energy consumption modeling, and environmental impact assessment. Visual Insights: A variety of plots to visualize system performance and design trade-offs. The engine for the website (REACT) bases on several Python libraries, and the website will be hosted on an ETA server.

Kim, Donghun [Lawrence Berkeley National Laborator↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Regional Energy Consumption for Direct Drone and Truck Deliveries

Drone delivery, once thought of as fictitious, is becoming a reality with the efforts of both forward-looking enterprises and supportive government policies. This emerging mode of e-commerce delivery raises many concerns. One important concern is the energy efficiency of direct delivery drones compared with conventional delivery trucks at a regional systems level. Here, in this study, we develop and apply methods to quantify the regional energy impacts of drone delivery, then we assess these impacts and compare them with the impacts of truck delivery. To study this problem, we develop an optimization model that determines an optimal set of fulfillment centers (FCs) with variable service capacities that allow drones to make direct e-commerce deliveries. We adopt two drone delivery energy estimation models from the literature and use them as inputs to demonstrate the potential range of energy needs. We also develop another optimization model to account for the energy consumption of diesel trucks (DTs) and battery electric vehicles (BEVs). We test the models using validated simulation data for the Chicago metropolitan area in the U.S. to quantify the energy implications of these three delivery modes. For drone delivery, we further extend our analyses by considering the impact of wind speed and flight patterns. Our results show that direct delivery drones require 15.8% more energy than BEVs on an average windy day, and they need 15% more energy than DTs on a very windy day. We provide essential parameter values for reproducibility and list relevant open problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Consumption and Cost Reduction of Future Light-Duty Vehicles through Advanced Vehicle Technologies: A Modeling Simulation Study Through 2050

The U.S. Department of Energy’s (DOE’s) Vehicle Technologies Office (VTO) and Hydrogen and Fuel Cell Technologies Office (HFTO) aim to develop sustainable, affordable and efficient technologies for transportation of goods and people. Translating investments in advanced transportation component technologies and powertrains to estimate vehicle-level fuel savings potential is critical for understanding DOE’s impact. In this work, we simulated technologies funded by VTO and HFTO for light duty vehicles. The simulations were performed across: Multiple powertrain configurations (i.e., conventional, power-split, extended-range electric vehicle, battery electric drive, and fuel-cell vehicles), Vehicle classes (i.e., compact car, midsize car, small sport utility vehicle [SUV], midsize SUV, and pickup trucks); and Fuels (i.e., gasoline, diesel, hydrogen, and battery electricity). These various technologies are assessed for six different timeframes: laboratory years 2015, 2020, 2025, 2030, and 2045. A delay of 5 years is assumed between laboratory year and model year (year technology is introduced into production). Finally, uncertainties are included for both technology performance and cost aspects by considering two cases: Low case, aligned with DOE technology manager estimates of expected original equipment manufacturer (OEM) improvements based on regulations, business as usual; and High case, aligned with aggressive technology advancements based on R&D targets developed through support by VTO & HFTO. These scenarios are not intended as predictions of future performances. The energy and cost impact of different technologies were estimated using Autonomie (www.autonomie.net), Argonne vehicle system simulation tool. Autonomie is a state-of-the-art vehicle system simulation tool used to assess the energy consumption, performance and cost of multiple advanced vehicle technologies across classes (from light to heavy duty), powertrains (from conventional to HEVs, FCEVs, PHEVs and BEVs), components and control strategies. Autonomie is packaged with a complete set of vehicle models for a wide range of vehicle classes, powertrain configurations and component technologies, including vehicle level and component level controls. These controls were developed and calibrated using dynamometer test data. Autonomie has been used to support a wide range of studies including analyzing various component technologies, sizing powertrains components for different vehicle requirements, comparing the benefits of powertrain configurations, optimizing both heuristic and route based vehicle energy control and predicting transportation energy use when paired with a traffic modeling tool such as POLARIS. This report documents the assumptions and estimates the vehicle-level energy consumption benefits and associated technology costs for the various types of light duty vehicles. All details of vehicle assumptions and simulation results are available in the spreadsheets accompanying this report.

33 ADVANCED PROPULSION SYSTEMS↗

Passive Energy-Saving Solutions for Clothes Dryers: A Modeling and Experimental Study for Improved Efficiency and Affordability

Dryers are integral appliances in modern households, yet their significant power consumption remains a critical challenge for reducing energy bills and upgrades. This work presents the outcomes of a comprehensive investigation aimed at lowering the operating energy costs of the dryer through modeling and experimental approaches. Specifically, the objectives of this research are twofold: (1) to reduce energy consumption without negatively impacting drying performance or time; and (2) to ensure affordability by developing retrofittable solutions characterized by low cost and a quick payback period. These strategies promise universal applicability to all dryer categories, encompassing both gas and electric models, by tackling core issues such as unnecessary heat loss and excess energy supply, both prevalent across dryer designs. Our methodology combines robust modeling frameworks and experimental validation to target energy efficiency improvements through three primary pathways: (1) effective heat loss management using ultralow-cost insulation materials tailored for dryer systems; (2) heat management across the drying cycle, facilitated by passive heat transfer mechanisms, and (3) optimization of heat supply to the load to ensure precise energy delivery, minimizing waste. These innovations are designed to seamlessly integrate with existing dryer configurations, providing a scalable and retrofittable solution that ensures affordability without requiring substantial redesigns or expensive components. Using these methods, the study demonstrates improvement opportunities in dryer energy consumption while maintaining the desired performance. The modeling component utilizes computational simulations to evaluate the thermal and energy performance of these innovations under varied operational conditions, providing foundational insights for experimental design. By addressing critical areas such as heat loss, energy recovery, and supply optimization, this work proposes impactful solutions for lowering the energy costs in domestic clothes dryers. The ultralow-cost, retrofittable nature of the proposed strategies ensures widespread adoption potential across diverse dryer categories, making significant strides toward affordable household energy practices.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

RouteE API

This is the API endpoint for RouteE energy prediction, which can be used to get both single vehicle link or route energy estimates and transportation network-wide energy consumption estimates for a variety of vehicles. This enables external researchers and transportation engineers to access and utilize NREL's growing library of pre-trained vehicle models for prediction of transportation energy consumption. This API provides three endpoints: • /route: Energy estimation of a vehicle over a planning link or sequence of links (route). • /network: Network-wide estimation of energy consumption for all vehicle traffic in the desired area. • /compass: Energy-optimal “eco-routing” between input origin and destination coordinates (Currently in beta for Denver metro area only).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RouteE API

This is the API endpoint for RouteE energy prediction, which can be used to get both single vehicle link or route energy estimates and transportation network-wide energy consumption estimates for a variety of vehicles. This enables external researchers and transportation engineers to access and utilize NREL's growing library of pre-trained vehicle models for prediction of transportation energy consumption. This API provides three endpoints: - /route: Energy estimation of a vehicle over a planning link or sequence of links (route). - /network: Network-wide estimation of energy consumption for all vehicle traffic in the desired area. - /compass: Energy-optimal “eco-routing” between input origin and destination coordinates (Currently in beta for Denver metro area only).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗