Search NASA⌕ Search

SEARCH · Search NASA

Results for “engine downsizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

86 records · Page 5

Oxygen Surface Functionalization of Graphene Nanoribbons for Transport Gap Engineering

We numerically investigate the impact of epoxide adsorbates on the transport properties of graphene nanoribbons with width varying from a few nanometers to 15 nm. For the wider ribbons, a scaling analysis of conductance properties is performed for adsorbate density ranging from 0.1% to 0.5%. Oxygen atoms introduce a large electron–hole transport asymmetry with mean free paths changing by up to 1 order of magnitude, depending on the hole or electron nature of charge carriers. The opening of a transport gap on the electron side for GNRs as wide as 15 nm could be further exploited to control current flow and achieve larger ON/OFF ratios, despite the initially small intrinsic energy gap. The effect of the adsorbates in narrow ribbons is also investigated by full ab initio calculations to explore the limit of ultimate downsized systems. In this case, the inhomogeneous distribution of adsorbates and their interplay with the ribbon edge are found to play an important role.

Chemistry↗

Development of Ultra Small Scale Mechanical Testing and Localized He Implantation for Nuclear Applications

Mechanical properties degradation of components deployed in nuclear applications has been a concern since the deployment of first generation nuclear power plants. Radiation damage along with environmental degradation, elevated temperatures, and long term deployment of nuclear structures pose a challenging environment for all materials in these applications. Traditionally, the mechanical properties are assessed by standardized macroscopic testing methods. While those are providing engineering relevant data these techniques do have limitations, especially on reactor irradiated materials, due to the large size of the samples. Limitations on the amount of radioactivity of large samples must be applied for research applications as they are conducted at universities. In addition it can be difficult to retrieve sufficiently large amounts of material from an operating reactor component. Therefore smaller sample sizes are desirable and reduce the amount of radioactive material which needs to be handled or material which needs to be retrieved. In addition, the number of tests which can be performed on materials irradiated in a test reactor program is limited due to limited space in specific dose and temperature positions. Downsizing of the mechanical test can overcome this issue and perform more tests on the same amount of irradiated materials, reducing the statistical uncertainties. In addition, smaller scale samples allow access to specific regions of interest in a material or component, be it the zone in front of a crack tip or the sampling of very small components like springs or welded areas. In addition ion beam irradiation has become an integral part of nuclear materials research to enhance the understanding of radiation damage in materials in a time and cost effective fashion. The drawback of ion beam irradiation is the small penetration depth of the ions into the material making localized microstructural characterization as well as small scale mechanical testing necessary. Another more fundamental motivation is the fact that since the beginning of electron microscopy, one has been concerned about imaging and quantifying defects in materials. Multiscale tools to image a large range of radiation induced defects have been established starting from atom probe tomography to transmission electron microscopy, up to scattering techniques. Mechanical testing, however, has always been performed on a large scale, and an attempt to match the same scale where a defect is observed with the materials' mechanical property response has not yet been realized. However, the question of separate effects testing on specific radiation induced defects remains and is an additional driving force for small scale mechanical testing. In this work we present an approach for small scale mechanical testing in irradiated materials and the variety of possible test methods developed today. We also present recent efforts of performing localized ion beam implantation to achieve a number of different doses in the same region of interest enhancing comparability and quantification of observed phenomena. It is the intention to give the reader an overview of the different microscale mechanical testing techniques possible today as well as an introduction of a novel ion beam irradiation method using a newly established capability. In this paper we can't discuss all aspects of all small scale mechanical testing of irradiated materials However, It does give an overview over the techniques enabled due to recent effort and enhanced instrument capability. While indentation or micro compression testing has been performed previously tensile testing and ion beam irradiation using the He ion beam microscope are novel approaches not attempted previously. (authors)

36 MATERIALS SCIENCE↗

A high-fidelity residential building occupancy detection dataset

Abstract This paper describes development of a data acquisition system used to capture a range of occupancy related modalities from single-family residences, along with the dataset that was generated. The publicly available dataset includes: grayscale images at 32-by-32 pixels, captured every second; audio files, which have undergone processing to remove personally identifiable information; indoor environmental readings, captured every ten seconds; and ground truth binary occupancy status. The data acquisition system, coined the mobile human presence detection (HPDmobile) system, was deployed in six homes for a minimum duration of one month each, and captured all modalities from at least four different locations concurrently inside each home. The environmental modalities are available as captured, but to preserve the privacy and identity of the occupants, images were downsized and audio files went through a series of processing steps, as described in this paper. This dataset adds to a very small body of existing data, with applications to energy efficiency and indoor environmental quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerothermodynamic Flight Simulation Capabilities for Aerospace Vehicles

Aerothermodynamics, encompassing aerodynamics, aeroheating, and fluid dynamics and physical processes, is the genesis for the design and development of advanced space transportation vehicles and provides crucial information to other disciplines such as structures, materials, propulsion, avionics, and guidance, navigation and control. Sources of aerothermodynamic information are ground-based facilities, Computational Fluid Dynamic (CFD) and engineering computer codes, and flight experiments. Utilization of this aerothermodynamic triad provides the optimum aerothermodynamic design to safely satisfy mission requirements while reducing design conservatism, risk and cost. The iterative aerothermodynamic process for initial screening/assessment of aerospace vehicle concepts, optimization of aerolines to achieve/exceed mission requirements, and benchmark studies for final design and establishment of the flight data book are reviewed. Aerothermodynamic methodology centered on synergism between ground-based testing and CFD predictions is discussed for various flow regimes encountered by a vehicle entering the Earth s atmosphere from low Earth orbit. An overview of the resources/infrastructure required to provide accurate/creditable aerothermodynamic information in a timely manner is presented. Impacts on Langley s aerothermodynamic capabilities due to recent programmatic changes such as Center reorganization, downsizing, outsourcing, industry (as opposed to NASA) led programs, and so forth are discussed. Sample applications of these capabilities to high Agency priority, fast-paced programs such as Reusable Launch Vehicle (RLV)/X-33 Phases I and 11, X-34, Hyper-X and X-38 are presented and lessons learned discussed. Lastly, enhancements in ground-based testing/CFD capabilities necessary to partially/fully satisfy future requirements are addressed.

Miller, Charles G.↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lateral Confinement in 2D Nanoplatelets: A Strategy to Expand the Colloidal Quantum Engineering Toolbox

Among colloidal nanocrystals, 2D nanoplatelets offer a unique set of properties with exceptionally narrow luminescence and low lasing thresholds. Furthermore, their anisotropic shape expands the playground for the complex design of heterostructures where spectra but also scattering rates can be engineered. A challenge that still remains is to combine shell growth which makes NPLs stable, with spectral tunability. Indeed, most reported shelled nanoplatelets end up being red emitters due to a loss of quantum confinement. Here, the combination of both lateral and in-plane confinements within a single heterostructure is explored. A CdS/CdSe/CdS/CdZnS core–crown–crown shell structure that enables yellow emission is grown and that is responsive to a large range of excitation including visible photons, X-ray photons, electron beams, and electrical excitations. k.p simulations predict that emission tunability of up to several 100 s of meV can be obtained in ideal structures. This material also displays stimulated emission resulting from bi-exciton emission with a low threshold. Once integrated into an LED stack, this material is compatible with sub-bandgap excitation and exhibits high luminance. Scaling of the electroluminescence properties by downsizing the pixel size is also investigated.

2D materials↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Of red planets and indigo computers: Mars database visualization as an example of platform downsizing

The last decade has witnessed tremendous advancements in the computer hardware and software used to perform scientific visualization. In this paper, we consider how the visualization of a particular data set, the digital terrain model derived from the Viking orbiter imagery, has been realized in four distinct projects over this period. These examples serve to demonstrate how the vast improvements in computational performance both decrease the cost of such visualization efforts and permit an increasing level of interactivity. We then consider how even today's graphical systems require the visualization designer to make intelligent choices and tradeoffs in database rendering. Finally, we discuss how insights gleaned from an understanding of human visual perception can guide these design decisions, and suggest new options for visualization hardware and software.

NASA Center ARC↗

Automated Design and Analysis of a Variable Displacement Linkage Motor

Hydrostatic drives consisting of a variable displacement pump and a low speed high torque (LSHT) motor are frequently used in off-highway vehicles. A variable displacement traction motor is desirable because of the ability to downsize the pump and thereby run the hydrostat at higher efficiency, as well as the possibility of hybridization of the drivetrain. Currently on the market are fixed and discrete speed LSHT radial piston motors and high speed low torque variable displacement axial piston motors. The radial piston motors are displacement dense but are not continuously variable, whereas the axial piston motors are continuously variable but require gearboxes, introducing packaging and robustness concerns. The Variable Displacement Linkage Motor (VDLM) is a LSHT motor that is continuously variable. It offers several benefits over current LSHT motors in that it is highly efficient over its operating range, it has low torque ripple, and it is displacement dense due to its multi-lobed cam and radial packaging. As with the design of any motor, the process is iterative and must be performed whenever performance objectives change. This paper describes an automated method for rapid exploration of the solution space for a variable displacement motor with specific application to the VDLM. This method leads to a motor design that theoretically can achieve 97% efficiency with a torque ripple below 5% at full displacement.

42 ENGINEERING↗

Hybrid Hydraulic-Electric Architecture (HHEA) for Mobile Machines (Final Report)

Traditionally, off-road mobile machines such as excavators and wheel loaders are primarily powered by hydraulics, and throttling valves are used to control their work circuits. In recent years, two general trends are towards more energy efficient systems and electrification. With electrification, both efficiency and control performance can be improved by the elimination of throttling losses and the use of high-bandwidth inverter control. Electrification is generally accomplished with Electro-hydraulic actuators (EHA) but they are limited to lower powered systems due to the high cost of electric machines capable of high power or high torque. This project proposes a new system architecture for off-road vehicles - Hybrid Hydraulic Electric Architecture (HHEA) to improve efficiency and control performance without requiring large electric machines. The widely applicable architecture combines hydraulic power and electric power in such a way that the majority of power is provided hydraulically while electric drives are used to modulate this power. In particular, HHEA utilizes multiple common pressure rails to transmit the majority of power and small electric machines to modulate the power. The energy-saving potential of the the HHEA has been validated for the work circuits of a variety of mobile machines, from small 5-ton excavators to medium sized 20-ton excavators and wheel loaders, and representative duty cycles to reduce energy input by 50-80% compared to the commercial state-of-art load-sensing systems. In addition, the corner power requirements of the electrical machines can be downsized by 85% compared to the EHA approach. Various tradeoff studies have also been conducted, including sensitivities to individual components performances, controllers, accumulator sizes, and variations of the system architecture etc. A control strategy has been developed to maintain or exceed the motion control precision compared to current systems. The motion control strategy consists of a nominal controller, based on a passivity-based backstepping design, and a transition controller, based on least-norn feedforward design. The nominal controller is used in between common pressure rail switches whereas the transition controller compensates for any disturbance that common pressure rail switchings inflict on the system. The control strategy has been experimentally validated on both a medium pressure (200bar) hardware-in-the-loop (HIL) testbed and a high pressure (300+bar) HIL testbed. An efficient and power-dense integrated electric-hydraulic machine consisting of an axial flux electric machine and a radial hydrostatic piston hydraulic machine has been designed, constructed and tested. The machine has an active material power density of 6.1kW/kg, a rated speed of 12500 RPM, and a design efficiency of 85%. This is among the highest power density electric machines using conventional materials. While the integrated machine was designed for modulating the hydraulic power within the HHEA, it can also be used in other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reconstructing Oxygen-Deficient Zirconia with Ruthenium Catalyst on Atomic-Scale Interfaces toward Hydrogen Production

Downsizing a catalyst nanoparticle (NP) to a single atom (SA) has proven to be highly effective in increasing catalytic activity and decreasing the amount of catalyst required for various electrochemical reactions. However, insufficient stability of the single-atom site catalysts (SACs) is still a significant challenge for their practical application. Here, SACs firmly bound to stable metal oxide NPs are proposed to dramatically increase the electrochemical activity and stability of SA-based catalysts for hydrogen evolution reaction (HER). Starting from a Ru-infiltrated, Zr-based metal-organic framework (MOF), the tetragonal zirconium oxide (ZrO 2-x ) NPs-embedded carbon matrix is fabricated as support through facile pyrolysis. Simultaneously, Ru SAs as active sites are well dispersed on the surface of ZrO 2-x NPs due to the generation of oxygen vacancies in the tetragonal ZrO 2-x . Finally, the Ru-ZrO 2-x SAC exhibits a 4–5 times higher mass activity than commercial Pt and Ru catalysts and superior durability due to strong metal-support interaction (SMSI) between Ru atoms and ZrO 2-x substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

42 ENGINEERING↗

Novel Sorbent-Based Process for High Temperature Trace Metal Removal

The objective of this project was to demonstrate the efficacy of a novel sorbent can effectively remove trace metal contaminants (Hg, As, Se and Cd) from actual coal-derived synthesis gas streams at high temperature (above the dew point of the gas). The performance of TDA's sorbent has been evaluated in several field demonstrations using synthesis gas generated by laboratory and pilot-scale coal gasifiers in a state-of-the-art test skid that houses the absorbent and all auxiliary equipment for monitoring and data logging of critical operating parameters. The test skid was originally designed to treat 10,000 SCFH gas at 250 psig and 350 C, however, because of the limited gas handling capabilities of the test sites, the capacity was downsized to 500 SCFH gas flow. As part of the test program, we carried out four demonstrations at two different sites using the synthesis gas generated by the gasification of various lignites and a bituminous coal. Two of these tests were conducted at the Power Systems Demonstration Facility (PSDF) in Wilsonville, Alabama; a Falkirk (North Dakota) lignite and a high sodium lignite (the PSDF operator Southern Company did not disclose the source of this lignite) were used as the feedstock. We also carried out two other demonstrations in collaboration with the University of North Dakota Energy Environmental Research Center (UNDEERC) using synthesis gas slipstreams generated by the gasification of Sufco (Utah) bituminous coal and Oak Hills (Texas) lignite. In the PSDF tests, we showed successful operation of the test system at the conditions of interest and showed the efficacy of sorbent in removing the mercury from synthesis gas. In Test Campaign No.1, TDA sorbent reduced Hg concentration of the synthesis gas to less than 5 {micro}g/m{sup 3} and achieved over 99% Hg removal efficiency for the entire test duration. Unfortunately, due to the relatively low concentration of the trace metals in the lignite feed and as a result of the intermittent operation of the PSDF gasifier (due to the difficulties in the handling of the low quality lignite), only a small fraction of the sorbent capacity was utilized (we measured a mercury capacity of 3.27 mg/kg, which is only a fraction of the 680 mg/kg Hg capacity measured for the same sorbent used at our bench-scale evaluations at TDA). Post reaction examination of the sorbent by chemical analysis also indicated some removal As and Se (we did not detect any significant amounts of Cd in the synthesis gas or over the sorbent). The tests at UNDEERC was more successful and showed clearly that the TDA sorbent can effectively remove Hg and other trace metals (As and Se) at high temperature. The on-line gas measurements carried out by TDA and UNDEERC separately showed that TDA sorbent can achieve greater than 95% Hg removal efficiency at 260 C ({approx}200g sorbent treated more than 15,000 SCF synthesis gas). Chemical analysis conducted following the tests also showed modest amounts of As and Se accumulation in the sorbent bed (the test durations were still short to show higher capacities to these contaminants). We also evaluated the stability of the sorbent and the fate of mercury (the most volatile and unstable of the trace metal compounds). The Synthetic Ground Water Leaching Procedure Test carried out by an independent environmental laboratory showed that the mercury will remain on the sorbent once the sorbent is disposed. Based on a preliminary engineering and cost analysis, TDA estimated the cost of mercury removal from coal-derived synthesis gas as $2,995/lb (this analysis assumes that this cost also includes the cost of removal of all other trace metal contaminants). The projected cost will result in a small increase (less than 1%) in the cost of energy.

01 COAL, LIGNITE, AND PEAT↗

Wound Field and Hybrid Synchronous Machines for EV Traction with Brushless Capacitive Rotor Field Excitation (Final Report)

This project focused on the development of wound field synchronous machines (WFSMs) and hybrid excitation synchronous machines (HESMs) with brushless capacitive power transfer for the field excitation. The target application for the machines developed is the main traction motor in electric vehicles. The magnetization in these types of machines is provided by a field winding on the rotor which is excited with DC current. The magnetization level in the machine can be varied by changing the magnitude of the field current. The variable magnetization or field is one of the key features of WFSMs. WFSMs are commonly used as generators however they have several attractive features for automotive traction applications. 1) No use of permanent magnet: Rare earth permanent magnets are primarily mined and processed in China. They have been subject to large price and supply variations and their export may be restricted during times of geopolitical tension. 2) Easy field weakening: Wound field synchronous machines have complete control of their field excitation. With proper design, this type of machine can electromagnetically have an infinite constant power speed range. 3) High power factor: With proper choice of the field excitation, WFSMs may be operated with high or even unity power factor. This potentially allows for the inverter connected to the stator winding to be downsized. In comparison induction machines and interior permanent magnet synchronous machines must supply reactive power to the stator increasing the kVA rating and cost of the inverter. 4) Reduced iron losses at high speed: By reducing the field excitation, the iron loss in the stator can be reduced. This is in comparison to interior permanent magnet synchronous machines which must use stator current to buck or reduce the flux produced by the permanent magnets. Generally, WFSMs have their highest efficiency at high speed. 5) Torque output at high temperatures: The magnetization provided by the field winding only depends on the field current and not on the field winding temperature. This is in contrast to permanent magnet machines where the permanent magnet flux decreases as the magnet temperature increases. Historically a number of approaches have been developed to provide DC current to the rotating field winding in WFSM’s including brushes and slip rings, low frequency brushless exciters, and high frequency rotary transformers and rectifiers. In this project, a different approach was used: brushless capacitive power transfer. Brushless capacitive power transfer uses two sets of rotating capacitors or electrodes in which an AC electric field is established by a high frequency inverter. A displacement current can flow through the airgap in the rotating capacitors which is rectified on the rotor using a diode bridge. The potential advantage of capacitive power transfer is that there is no need for heavy iron to guide magnetic flux. The electric flux lines terminate on the charges on the rotary capacitor surfaces. This should also limit the electric field outside the rotary capacitor airgaps. The main challenge with capacitive power transfer is that the capacitance and surface area of the rotating capacitors is small. Because capacitive power transfer systems are essentially a dual of a magnetic system, an Ampere per Hertz relationship is characteristic versus a Volts per Hertz relationship. A very high frequency power inverter must be used to provide sufficient excitation to the field winding. The concept of using capacitive power transfer to excite a high performance WFSM was initially developed in a previous U.S.A. Dept. of Energy project, DE-EE0006829. This project focused on increasing the power density of the WFSMs and reducing the cost and manufacturing complexity of the capacitive power transfer system. This project has demonstrated that WFSMs with brushless capacitive field power transfer can provide a high-power density and low-cost automotive powertrain technology.

33 ADVANCED PROPULSION SYSTEMS↗