Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation datasets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Re-evaluating probable maximum precipitation estimates: sensitivity to transposition domains and storm rotation using modern datasets

This study examines the sensitivity of Probable Maximum Precipitation (PMP) estimates to key methodological decisions embedded in the legacy approach adopted in the U.S. National Weather Service Hydrometeorological Reports No. 51 and No. 52. Although widely used for infrastructure design and risk regulation, fundamental aspects of PMP estimation—such as storm sample size, transposition domain, maximization procedures, and storm rotation—remain poorly constrained and lack formal guidance. Using the Red Rock watershed in Iowa as a case study, and leveraging the 2002–2023 NOAA Analysis of Record for Calibration (AORC) precipitation dataset, we systematically evaluate how each methodological choice, individually and in combination, influences PMP estimates. Our findings demonstrate that PMP is not a fixed physical upper bound but rather a modeling construct shaped heavily by user-defined assumptions. Notably, PMP values derived from modern gridded rainfall datasets can be substantially higher than the legacy estimate used in the original spillway design for Red Rock Dam. Decisions regarding storm sample size, domain extent, climatological window, and particularly storm rotation all contributed to higher PMP estimates. Storm rotation alone—a loosely constrained element in the current PMP practice—can amplify PMP by more than 25%. These results reveal the lack of standardized bounds in current PMP workflows and the need for systematic sensitivity and uncertainty analysis. As PMP estimation shifts toward probabilistic approaches, incorporating physically meaningful storm attributes will be key to developing more transparent, defensible methods for dam safety and climate-resilient infrastructure.

Probable maximum precipitation↗

Leveraging large language models to address data scarcity in machine learning for graphene synthesis

Machine learning in experimental materials science faces significant challenges due to the scarcity of data, which are costly and time-consuming to generate, particularly when relying on in-house experiments. Literature data mining offers a potential solution but introduces issues like mixed data quality, inconsistent formats, and non-uniform reporting of synthesis parameters, resulting in partially missing and heterogeneous features across the dataset. Here, we propose data imputation and feature engineering methods that employ pre-trained large language models (LLMs) to enhance machine learning performance on scarce, heterogeneous datasets, demonstrated on graphene CVD synthesis data and the ML-HydPARK hydrogen storage dataset. GPT models perform data imputation via tailored prompting and semantic normalization of inconsistently reported features through embeddings, for example, to harmonize the complex nomenclature of CVD substrates. Beyond yielding more diverse and richer feature representations than traditional methods such as K-nearest neighbors (KNN) and Multivariate Imputation by Chained Equations (MICE), LLM-based data imputation is evaluated against dataset characteristics and prompting strategies. We vary the level of autonomy granted to the LLM, from generic prompting that leverages pre-trained knowledge for autonomous data generation to data-informed prompting that constrains outputs using target-specific information, and demonstrate which level of autonomy yields superior imputation performance across datasets and feature types. The proposed data engineering methods markedly improve downstream performance; for example, in graphene layer number classification using a support vector machine (SVM), binary accuracy increases from 39% to 65% and ternary accuracy from 52% to 72%. Fine-tuning experiments on both datasets show that combining our proposed LLM-based data imputation and feature encoding methods with numerical machine learning predictors outperforms standalone fine-tuned LLM predictors in data-scarce settings. The proposed strategies emphasize data enhancement techniques rather than refining learning architectures or regularizing loss functions, offering a broadly applicable framework for improving machine learning performance on scarce, inhomogeneous datasets.

Chemical vapor deposition↗

Use of volumetric features for temporal comparison of mass lesions in full field digital mammograms

Purpose: Temporal comparison of lesions might improve classification between benign and malignant lesions in full-field digital mammograms (FFDM). The authors compare the use of volumetric features for lesion classification, which are computed from dense tissue thickness maps, to the use of mammographic lesion area. Use of dense tissue thickness maps for lesion characterization is advantageous, since it results in lesion features that are invariant to acquisition parameters. Methods: The dataset used in the analysis consisted of 60 temporal mammogram pairs comprising 120 mediolateral oblique or craniocaudal views with a total of 65 lesions, of which 41 were benign and 24 malignant. The authors analyzed the performance of four volumetric features, area, and four other commonly used features obtained from temporal mammogram pairs, current mammograms, and prior mammograms. The authors evaluated the individual performance of all features and of different feature sets. The authors used linear discriminant analysis with leave-one-out cross validation to classify different feature sets. Results: Volumetric features from temporal mammogram pairs achieved the best individual performance, as measured by the area under the receiver operating characteristic curve (A{sub z} value). Volume change (A{sub z} = 0.88) achieved higher A{sub z} value than projected lesion area change (A{sub z} = 0.78) in the temporal comparison of lesions. Best performance was achieved with a set that consisted of a set of features extracted from the current exam combined with four volumetric features representing changes with respect to the prior mammogram (A{sub z} = 0.90). This was significantly better (p = 0.005) than the performance obtained using features from the current exam only (A{sub z} = 0.77). Conclusions: Volumetric features from temporal mammogram pairs combined with features from the single exam significantly improve discrimination of benign and malignant lesions in FFDM mammograms compared to using only single exam features. In the comparison with prior mammograms, use of volumetric change may lead to better performance than use of lesion area change.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High bias machine learning for antineutrino-based safeguards for small reactors

The statistical methods used for antineutrino detection will need to be improved to effectively monitor the inventory of next-generation nuclear reactors. In this sensitivity study, we evaluate machine learning models compared to previously used statistical approaches to identify diversion scenarios in a simulated Advanced Fast Reactor (AFR)-100. A chi-square goodness-of-fit technique, which individually compares the simulated antineutrino yields to the expected antineutrino yield, resulted in precise but low diversion detection probability. Various support vector machine (SVM) models were applied with diverse training datasets to evaluate the robustness of the method towards unexpected or “unseen” diversion scenarios. Furthermore, our results indicate that while the SVM models significantly improved the detection probability of near-field antineutrino-based safeguards, up to a probability of ~0.04, for the simulated small reactor, the detection system still needs improvements to reach the 0.2 detection limit established by the International Atomic Energy Agency.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Machine learning and atomic layer deposition: Predicting saturation times from reactor growth profiles using artificial neural networks

In this work, we explore the application of deep neural networks to the optimization of atomic layer deposition (ALD) processes. In particular, we focus on a one-shot optimization problem, where we try to predict the optimal dose time that leads to saturation everywhere in the reactor based on thickness values measured at different points of an ALD reactor after a single trial growth. In order to tackle this problem, we introduce a dataset designed to train neural networks to predict saturation times based on these inputs for a cross-flow ALD reactor. Here, we then explore the predictive ability of artificial neural networks of different depths and sizes using a separate testing dataset to evaluate their accuracies. The results obtained show that networks trained using stochastic gradient descent methods can accurately predict saturation times without requiring any additional information on the surface kinetics. This provides a viable approach to minimize the number of experiments required to optimize new ALD processes in a known reactor, and it highlights the way machine learning can be leveraged for thin film growth and manufacturing. While the datasets and training procedure depend on the reactor geometry, the trained neural networks provide a general surrogate model connecting thickness values and trial dose times with optimal saturation times that can be reused for different ALD processes within the same reactor.

36 MATERIALS SCIENCE↗

Application of artificial intelligence methods in the international roughness index prediction of rigid and composite pavements: a systematic review

The International Roughness Index (IRI) is a widely adopted metric for quantifying pavement roughness, directly influencing vehicle safety, ride comfort, and overall roadway performance. In recent years, the use of Machine Learning (ML) models for IRI prediction has gained momentum, with the goal of improving the allocation of maintenance and rehabilitation resources by enabling accurate assessments of pavement conditions. Most prior reviews, however, have concentrated on flexible pavements, leaving a notable gap regarding rigid and composite pavements. To address this gap, the present study conducts a systematic review of Artificial Intelligence (AI) methods applied to IRI prediction for rigid and composite pavements. Literature published between 2004 and 2025 is synthesized to highlight prevailing trends, methodological contributions, and directions for future research. Particular attention is given to the types of models employed, the datasets used for training and validation, and the role of input variables and data-processing strategies. Across the included studies, ensemble learning methods (especially gradient boosting variants such as XGBoost), artificial neural networks, and hybrid architectures frequently achieved high predictive skill, with several models reporting test-set coefficients of determination approaching 0.9–0.96, indicating strong potential for capturing the influence of traffic, pavement structure, and climatic factors. Since these results are obtained from heterogeneous datasets and evaluation protocols, they are interpreted qualitatively rather than as strict cross-study rankings. Analysis of input variables revealed that pavement age and initial IRI were included in 91% (21 of 23) and 78% (18 of 23) of studies, respectively. Climatic variables such as the freezing index appeared in 57% (13 of 23), while traffic-related factors were considered in 65% (15 of 23). The findings underscore the importance of standardized, high-quality datasets, such as those from the Long-Term Pavement Performance (LTPP) program, along with data consistency, model interpretability, computational efficiency, and replicability in enhancing IRI prediction. Future research should focus on incorporating input variable selection techniques to identify the most influential predictors, thereby improving accuracy and robustness. Integrating these approaches with advanced non-linear data-driven models, coupled with robust hyperparameter optimization, holds considerable promise for strengthening the reliability of IRI prediction and supporting resilient pavement management strategies.

42 ENGINEERING↗

A scaling transformation for classifier output based on likelihood ratio: Applications to a CAD workstation for diagnosis of breast cancer

Purpose: The authors developed scaling methods that monotonically transform the output of one classifier to the ''scale'' of another. Such transformations affect the distribution of classifier output while leaving the ROC curve unchanged. In particular, they investigated transformations between radiologists and computer classifiers, with the goal of addressing the problem of comparing and interpreting case-specific values of output from two classifiers. Methods: Using both simulated and radiologists' rating data of breast imaging cases, the authors investigated a likelihood-ratio-scaling transformation, based on ''matching'' classifier likelihood ratios. For comparison, three other scaling transformations were investigated that were based on matching classifier true positive fraction, false positive fraction, or cumulative distribution function, respectively. The authors explored modifying the computer output to reflect the scale of the radiologist, as well as modifying the radiologist's ratings to reflect the scale of the computer. They also evaluated how dataset size affects the transformations. Results: When ROC curves of two classifiers differed substantially, the four transformations were found to be quite different. The likelihood-ratio scaling transformation was found to vary widely from radiologist to radiologist. Similar results were found for the other transformations. Our simulations explored the effect of database sizes on the accuracy of the estimation of our scaling transformations. Conclusions: The likelihood-ratio-scaling transformation that the authors have developed and evaluated was shown to be capable of transforming computer and radiologist outputs to a common scale reliably, thereby allowing the comparison of the computer and radiologist outputs on the basis of a clinically relevant statistic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-supervised and multi-fidelity learning for extended predictive soil spectroscopy

Infrared spectroscopy is a cost-effective, non-destructive, and environmentally benign technology that is increasingly recognized as an important solution for meeting the global demand for soil data. While both near-infrared (NIR) and mid-infrared (MIR) diffuse reflectance spectroscopy enable rapid estimation of soil properties, they present a significant trade-off: NIR offers superior scalability and lower operational costs, whereas MIR provides higher analytical fidelity by capturing fundamental molecular vibrations. In this study, we propose a self-supervised, multi-fidelity learning framework designed to bridge this gap. Our approach leverages large-scale MIR spectral libraries to learn a compact, transferable latent representation, into which NIR spectra are subsequently aligned for downstream prediction. The workflow consists of pretraining a latent model on a large MIR library, adapting the representation using a smaller paired NIR–MIR dataset, and evaluating generalization on an independent external test set. Across a range of chemical and physical soil properties, we found that MIR-derived embeddings improved prediction accuracy relative to baseline models that used raw MIR inputs. Predictions derived from the spectrum conversion (NIR to MIR) task did not match the performance of the original MIR spectra but were similar or superior to predictive performance of NIR-only models, suggesting the unified spectral latent space can effectively leverage the larger and more diverse MIR dataset for prediction of soil properties not well represented in current NIR libraries.

54 ENVIRONMENTAL SCIENCES↗

A maximum likelihood analysis of the CoGeNT public dataset

The CoGeNT detector, located in the Soudan Underground Laboratory in Northern Minnesota, consists of a 475 grams (fiducial mass of 330 grams) target mass of p-type point contact germanium detector that measures the ionization charge created by nuclear recoils. This detector has searched for recoils created by dark matter since December of 2009. We analyze the public dataset from the CoGeNT experiment to search for evidence of dark matter interactions with the detector. We perform an unbinned maximum likelihood fit to the data and compare the significance of different WIMP hypotheses relative to each other and the null hypothesis of no WIMP interactions. This work presents the current status of the analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Characteristics and Outcomes of Patients With Nodular Lymphocyte-Predominant Hodgkin Lymphoma Versus Those With Classical Hodgkin Lymphoma: A Population-Based Analysis

Purpose: Nodular lymphocyte-predominant Hodgkin lymphoma (NLPHL) is rare, comprising approximately 5% of all Hodgkin lymphoma (HL) cases. Patients with NLPHL tend to have better prognoses than those with classical HL (CHL). Our goal was to assess differences in survival between NLPHL and CHL patients, controlling for differences in patient and disease characteristics. Methods and Materials: Using data from the population-based Surveillance, Epidemiology and End Results (SEER) cancer registry program, we identified patients diagnosed with pathologically confirmed HL between 1988 and 2010. Results: We identified 1,162 patients with NLPHL and 29,083 patients with CHL. With a median follow-up of 7 years, 5- and 10-year overall survival (OS) rates were 91% and 83% for NLPHL, respectively, and 81% and 74% for CHL, respectively. After adjusting for all available characteristics, NLPHL (vs CHL) was associated with higher OS (hazard ratio [HR]: 0.62, P<.01) and disease-specific survival (DSS; HR: 0.48, P<.01). The male predominance of NLPHL, compared to CHL, as well as the more favorable prognostic features in NLPHL patients are most pronounced in NLPHL patients <20 years old. Among all NLPHL patients, younger patients were less likely to receive radiation, and radiation use has declined by 40% for all patients from 1988 to 2010. Receipt of radiation was associated with better OS (HR: 0.64, P=.03) and DSS (HR: 0.45, P=.01) in NLPHL patients after controlling for available baseline characteristics. Other factors associated with OS and DSS in NLPHL patients are younger age and early stage. Conclusions: Our results in a large population dataset demonstrated that NLPHL patients have improved prognosis compared to CHL patients, even after accounting for stage and baseline characteristics. Use of radiation is declining among NLPHL patients despite an association in this series between radiation and better DSS and OS. Unique treatment strategies for NLPHL are warranted in both early and advanced stage disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rotational and axial motion system load frame insert for in situ high energy x-ray studies

High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency. It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 × 1.5 × 3.0 mm{sup 3} could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct measurements of ion dynamics in collisional magnetic presheaths

Ion velocities and temperatures are measured in the presheath of a grounded plate downstream from an argon helicon plasma source using laser-induced fluorescence (P{sub rf}≈450→750 W, T{sub e}=2.5→5 eV, T{sub i}=0.1→0.6 eV, n{sub 0}≈1×10{sup 12}cm{sup −3}, p{sub n}=1→6.5 mTorr, λ=0.3→2 cm, ρ{sub i}≈ 0.5 cm). The plate is held 16°→60° relative to the 1 kG background axial magnetic field. The velocity profiles are compared to a 1D fluid model similar to those presented by Riemann [Phys. Plasmas 1, 552 (1994)] and Ahedo [Phys. Plasmas 4, 4419 (1997)] for the 1 mTorr dataset and are shown to agree well. The model is sensitive to parameters such as collision and ionization frequencies and simplified models, such one presented by Chodura [Phys. Fluids 25, 1628 (1982)], are shown to be inaccurate. E{sup →}×B{sup →} flows as large as 40% of c{sub s} at the sheath edge are inferred. Definitions for the term “magnetic presheath” and implications for ion flow to tokamak divertors and Hall thruster walls are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Structure Investigation of Sr{sub 3}NbGa{sub 3}Si{sub 2}O{sub 14} Langasite Family Crystal

An accurate structure analysis of Sr{sub 3}NbGa{sub 3}Si{sub 2}O{sub 14} single crystals, belonging to the langasite family, has been performed. Two datasets are obtained on an Xcalibur S diffractometer equipped with a CCD detector. The structure is been refined using an averaged dataset: sp. gr. P 321, Z = 1, 295 K, sin θ/λ ≤ 1.35 Å{sup –1}, a = 8.2797(3) Å, c = 5.0774(5) Å; the agreement factors between the model and experiment are found to be R/wR = 0.76/0.64% and Δρ{sub min}/Δρ{sub max} =–0.21/0.17 e/Å{sup 3} for 3820 independent ref lections. The Sr{sub 3}NbGa{sub 3}Si{sub 2}O{sub 14} and Sr{sub 3}NbFe{sub 3}Si{sub 2}O{sub 14} structures are compared, and the role of magnetic ions in the predicted P321 → P3 phase transition is analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric comparison of metastatic spinal photon treatment techniques

Traditional palliative treatment of metastatic cancer to the vertebral bodies often results in doses to the spinal cord that are higher than the dose prescribed to the target, or gross tumor volume (GTV). This study compares traditional techniques of spine palliation with intensity-modulated radiation therapy (IMRT). The purpose of the study is 2-fold: first, the study demonstrates the benefits of using IMRT to lower the dose to the organs at risk (OAR), particularly for the spinal cord and other nonspecified normal tissues; second, the article provides information regarding the advantages and disadvantages of commonly used conventional techniques for treating the vertebral bodies based on patient anatomy. Because the use of IMRT or other advanced techniques may be prohibitive because of insurance issues, treatment plans were created that compared optimal coverage vs. optimal sparing for single-field, wedged-pair, and opposed-beam arrangements. Fifty-five patients were selected and divided by location of target (cervical, thoracic, and lumbar spine) and also by the measured separation between the anterior and posterior surface of the patient at the level of mid-GTV. Within each anatomic category the patients again were divided into the categories of small, medium, and large based on separation. The patient dataset that most closely represented the average separation within each category was selected, resulting in a total of 9 patients, and the appropriate treatment plan techniques were calculated for each of the 9 patients. The results of the study do show that the use of IMRT is far superior when compared with other techniques, both for coverage and for sparing of the surrounding tissue, regardless of patient size and the section of spine being treated. Based on a combination of both target coverage and sparing of normal tissues, the conventional plan of choice may vary by both the section of spine to be treated and by the size of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Two-stage atlas subset selection in multi-atlas based image segmentation

Purpose: Fast growing access to large databases and cloud stored data presents a unique opportunity for multi-atlas based image segmentation and also presents challenges in heterogeneous atlas quality and computation burden. This work aims to develop a novel two-stage method tailored to the special needs in the face of large atlas collection with varied quality, so that high-accuracy segmentation can be achieved with low computational cost. Methods: An atlas subset selection scheme is proposed to substitute a significant portion of the computationally expensive full-fledged registration in the conventional scheme with a low-cost alternative. More specifically, the authors introduce a two-stage atlas subset selection method. In the first stage, an augmented subset is obtained based on a low-cost registration configuration and a preliminary relevance metric; in the second stage, the subset is further narrowed down to a fusion set of desired size, based on full-fledged registration and a refined relevance metric. An inference model is developed to characterize the relationship between the preliminary and refined relevance metrics, and a proper augmented subset size is derived to ensure that the desired atlases survive the preliminary selection with high probability. Results: The performance of the proposed scheme has been assessed with cross validation based on two clinical datasets consisting of manually segmented prostate and brain magnetic resonance images, respectively. The proposed scheme demonstrates comparable end-to-end segmentation performance as the conventional single-stage selection method, but with significant computation reduction. Compared with the alternative computation reduction method, their scheme improves the mean and medium Dice similarity coefficient value from (0.74, 0.78) to (0.83, 0.85) and from (0.82, 0.84) to (0.95, 0.95) for prostate and corpus callosum segmentation, respectively, with statistical significance. Conclusions: The authors have developed a novel two-stage atlas subset selection scheme for multi-atlas based segmentation. It achieves good segmentation accuracy with significantly reduced computation cost, making it a suitable configuration in the presence of extensive heterogeneous atlases.

60 APPLIED LIFE SCIENCES↗

Modelling and analysis of turbulent datasets using Auto Regressive Moving Average processes

We introduce a novel way to extract information from turbulent datasets by applying an Auto Regressive Moving Average (ARMA) statistical analysis. Such analysis goes well beyond the analysis of the mean flow and of the fluctuations and links the behavior of the recorded time series to a discrete version of a stochastic differential equation which is able to describe the correlation structure in the dataset. We introduce a new index Υ that measures the difference between the resulting analysis and the Obukhov model of turbulence, the simplest stochastic model reproducing both Richardson law and the Kolmogorov spectrum. We test the method on datasets measured in a von Kármán swirling flow experiment. We found that the ARMA analysis is well correlated with spatial structures of the flow, and can discriminate between two different flows with comparable mean velocities, obtained by changing the forcing. Moreover, we show that the Υ is highest in regions where shear layer vortices are present, thereby establishing a link between deviations from the Kolmogorov model and coherent structures. These deviations are consistent with the ones observed by computing the Hurst exponents for the same time series. We show that some salient features of the analysis are preserved when considering global instead of local observables. Finally, we analyze flow configurations with multistability features where the ARMA technique is efficient in discriminating different stability branches of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-87: Automated Liver Segmentation Method for CBCT Dataset by Combining Sparse Shape Composition and Probabilistic Atlas Construction

Purpose: The aiming of this study was to extract liver structures for daily Cone beam CT (CBCT) images automatically. Methods: Datasets were collected from 50 intravenous contrast planning CT images, which were regarded as training dataset for probabilistic atlas and shape prior model construction. Firstly, probabilistic atlas and shape prior model based on sparse shape composition (SSC) were constructed by iterative deformable registration. Secondly, the artifacts and noise were removed from the daily CBCT image by an edge-preserving filtering using total variation with L1 norm (TV-L1). Furthermore, the initial liver region was obtained by registering the incoming CBCT image with the atlas utilizing edge-preserving deformable registration with multi-scale strategy, and then the initial liver region was converted to surface meshing which was registered with the shape model where the major variation of specific patient was modeled by sparse vectors. At the last stage, the shape and intensity information were incorporated into joint probabilistic model, and finally the liver structure was extracted by maximum a posteriori segmentation.Regarding the construction process, firstly the manually segmented contours were converted into meshes, and then arbitrary patient data was chosen as reference image to register with the rest of training datasets by deformable registration algorithm for constructing probabilistic atlas and prior shape model. To improve the efficiency of proposed method, the initial probabilistic atlas was used as reference image to register with other patient data for iterative construction for removing bias caused by arbitrary selection. Results: The experiment validated the accuracy of the segmentation results quantitatively by comparing with the manually ones. The volumetric overlap percentage between the automatically generated liver contours and the ground truth were on an average 88%–95% for CBCT images. Conclusion: The experiment demonstrated that liver structures of CBCT with artifacts can be extracted accurately for following adaptive radiation therapy. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

60 APPLIED LIFE SCIENCES↗