Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental data error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Study on the dynamic holdup distribution of the pulsed extraction column

In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel digital lifecycle for Material‐Process‐Microstructure‐Performance relationships of thermoplastic olefins foams manufactured via supercritical fluid assisted foam injection molding

Abstract This research significantly enhances the applicability of thermoplastic olefins (TPOs) in the automotive industry using supercritical N 2 as a physical foaming agent, effectively addressing the limitations of traditional chemical agents. It merges experimental results with simulations to establish detailed material‐process‐microstructure‐performance (MP2) relationships, targeting 5–20% weight reductions. This innovative approach labeled digital lifecycle (DLC) helps accurately predict tensile, flexural, and impact properties based on the foam microstructure, along with experimentally demonstrating improved paintability. The study combines process simulations with finite element models to develop a comprehensive digital model for accurately predicting mechanical properties. Our findings demonstrate a strong correlation between simulated and experimental data, with about a 5% error across various weight reduction targets, marking significant improvements over existing analytical models. This research highlights the efficacy of physical foaming agents in TPO enhancement and emphasizes the importance of integrating experimental and simulation methods to capture the underlying foaming mechanism to establish material‐process‐microstructure‐performance (MP2) relationships. Highlights Establishes a material‐process‐microstructure‐performance (MP2) for TPO foams Sustainably produces TPO foams using supercritical (ScF) N 2 with 20% lightweighting Shows enhanced paintability for TPO foam improved surface aesthetics Digital lifecycle (DLC) that predicts both foam microstructure and properties DLC maps process effects & microstructure onto FEA mesh for precise prediction

Engineering↗

Towards Full Field-of-View Fourier Ptychography for Extreme Ultraviolet Microscope

We evaluate various Fourier ptychographic microscopy (FPM) reconstruction algorithms using both simulated and experimental data acquired from an Extreme Ultraviolet (EUV, 13.5 nm wavelength) microscope. We specifically focus on the algorithms' ability to robustly address field-dependent aberrations, which enables increased spatial resolution and quantitative phase imaging across an expanded field of view. We systematically compare the algorithms' performance under aberrations for a single zoneplate imaging system, utilizing Fourier Ring Correlation (FRC) as a systematic metric for assessing reconstruction quality. Furthermore, we explore the impact of systematic errors on the reconstruction of experimental data, aiming to increase the effective field of view by 25-fold, from the nominal 5x5 um2 diffraction-limited area. Additionally, our evaluation incorporates innovative FPM-adjacent methodologies, including the Angular Ptychographic Imaging with Closed-form method (APIC), for reconstructing EUV images.

Gu, Chaoying↗

Dissolved gas recovery from water using a sidestream hollow-fiber membrane module: First principles model synthesis and steady-state validation

This paper presents a first-principles model for the recovery of dissolved gases from liquids using a sidestream hollow-fiber membrane module. The model avoids the use of new empirical coefficients, thus providing a parametric understanding of the process behavior for future design and optimization of membrane modules. This type of first-principles model could be particularly useful when gas recovery is beneficial to biological or chemical reactions of interest, such as the acetogenesis reactions in two-stage anaerobic digesters. The steady-state behavior of the model was validated against both new experimental data for the recovery of H 2 , CH 4 and H 2 –CH 4 mixtures from pure water, as well as existing published data. The modeled gas recovery predictions agreed with experimental data to an absolute average error of 13%, and an average R value of 0.98. Parametric analysis of mixed-gas recovery suggests possible key transition points in the composition of the recovered gases. For example, at 40 °C, increasing trans-membrane pressure while keeping hydraulic residence time (HRT) under 0.5 s will result in an increase in the ratio of H 2 to CH 4 recovered. Otherwise, increasing trans-membrane pressure will instead decrease the ratio of H 2 to CH 4 recovered. The model has potential to be extended to transient analysis, but has yet to be validated with transient experimental data. Furthermore, this model was successfully implemented in both Python and MATLAB, and provides valuable insights for future net-energy optimization for anaerobic digestion systems with in-situ gas recovery.

Anaerobic Digestion↗

SAXS Assistant: Automated SAXS analysis for structural discovery in biologics and polymeric nanoparticles

Small-angle x-ray scattering (SAXS) is a powerful technique for assessing macromolecular structure. High-throughput SAXS is limited by the time-consuming and, at times, subjective nature of SAXS data interpretation. Here, we present SAXS Assistant, a Python-based script that streamlines SAXS data analysis to extract features for machine learning (ML) and key structural parameters, including the Guinier radius of gyration (R g ), pair distance distribution function (PDDF)-derived R g , maximum particle dimension (D max ), and Kratky plots. The script builds upon BioXTAS RAW and validates reliability via Guinier/PDDF R g agreement, an important indicator of well-measured data sets. For assistance in D max estimation, a multilayer perceptron regressor was trained with 1940 data files from the Small Angle Scattering Biological Data Bank. The model achieved a test set performance R 2 = 0.90 and mean absolute error = 11.7 Å. Training exclusively with experimental data translates analyses from researchers, including experts in the field, to the ML model, which helps assess D max estimations from PDDF. Gaussian mixture model clustering was implemented to classify profiles into structural classes based on entries in the Small Angle Scattering Biological Data Bank. Users may therefore assess the similarity between experimental samples and known biomolecular shapes within the mapped repository entries. This probabilistic clustering aids in quantifying information from Kratky and generating shape-descriptive features. SAXS Assistant accelerates SAXS data analysis through enforced quality control, ML-ready outputs, and flags for low-confidence results. In addition to providing the ability to analyze large data sets at high throughput, this tool is versatile and may serve researchers in both biological and synthetic polymer research fields.

36 MATERIALS SCIENCE↗

On the reliability of HELIOSAT method: A comparison with experimental data

This study deals with comparison of Cameroonian ground based measurements with estimations done using satellite images, by applying the second version of the HELIOSAT method, as computed by the web tool HELIOCLIM of the SoDa project. Measurements and satellite resources were chosen for the same period of the year 1985, on ten Cameroonian locations, distributed with mean spatial resolution of 200 km between two neighbouring stations. Correlations curves are constructed between daily irradiation estimates from satellite data and from measurements. The consequent regression equations are established, using the least square method. Finally, a brief discussion is carried out on the spatial distribution of errors observed on results. Similarly to previous studies this study confirmed the capability of the method to produce good results for the Garoua location, and established its extension on other sahelian sites, comparatively to the poor agreement observed on southern sites. Furthermore, even if the study was not done on a long period, it brought out the necessity to correct the HELIOSAT results for many Cameroonian locations, to march the experimental results. (author)

14 SOLAR ENERGY↗

Do Practical Standard Coupled Cluster Calculations Agree Better than Kohn–Sham Calculations with Currently Available Functionals When Compared to the Best Available Experimental Data for Dissociation Energies of Bonds to 3d Transition Metals?

Coupled-cluster (CC) methods have been extensively used as the high-level approach in quantum electronic structure theory to predict various properties of molecules when experimental results are unavailable. It is often assumed that CC methods, if they include at least up to connected-triple-excitation quasiperturbative corrections to a full treatment of single and double excitations (in particular, CCSD(T)), and a very large basis set, are more accurate than Kohn–Sham (KS) density functional theory (DFT). In the present work, we tested and compared the performance of standard CC and KS methods on bond energy calculations of 20 3d transition metal-containing diatomic molecules against the most reliable experimental data available, as collected in a database called 3dMLBE20. It is found that, although the CCSD(T) and higher levels CC methods have mean unsigned deviations from experiment that are smaller than most exchange-correlation functionals for metal–ligand bond energies of transition metals, the improvement is less than one standard deviation of the mean unsigned deviation. Furthermore, on average, almost half of the 42 exchange-correlation functionals that we tested are closer to experiment than CCSD(T) with the same extended basis set for the same molecule. The results show that, when both relativistic and core–valence correlation effects are considered, even the very high-level (expensive) CC method with single, double, triple, and perturbative quadruple cluster operators, namely, CCSDT(2)Q, averaged over 20 bond energies, gives a mean unsigned deviation (MUD(20) = 4.7 kcal/mol when one correlates only valence, 3p, and 3s electrons of transition metals and only valence electrons of ligands, or 4.6 kcal/mol when one correlates all core electrons except for 1s shells of transition metals, S, and Cl); and that is similar to some good xc functionals (e.g., B97-1 (MUD(20) = 4.5 kcal/mol) and PW6B95 (MUD(20) = 4.9 kcal/mol)) when the same basis set is used. We found that, for both coupled cluster calculations and KS calculations, the T1 diagnostics correlate the errors better than either the M diagnostics or the B1 DFT-based diagnostics. The potential use of practical standard CC methods as a benchmark theory is further confounded by the finding that CC and DFT methods usually have different signs of the error. We conclude that the available experimental data do not provide a justification for using conventional single-reference CC theory calculations to validate or test xc functionals for systems involving 3d transition metals.

Environmental Molecular Sciences Laboratory↗

Measurement Uncertainty in One-of-a-kind Experiments

A golden standard in science is to repeat an experimental measurement multiple times and calculate the measured value with experimental uncertainty by following well developed statistical procedures. For various reasons – cost, technical difficulty, international treaties, ethics of dealing with human or animal subjects, ecology - many important experiments and observations can not be repeated. Astronomy, earthquakes, hurricanes produce data from one-of-a-kind events. When information is not available in any other way, it should not be dismissed as qualitative, anecdotal evidence only. Analyzed in a mathematically rigorous way, it produces quantitative experimental data. Analysis of data from one-of-a-kind event differs from analysis of repeated experiments’ data. For repeated experiments, the experimental error includes a range of true values generated by repetitions of the experiment, and measurement uncertainty caused by detectors. They are independent. Repetitions of any experiment, as similar as achievable, always have built-in differences resulting in a range of the true values rather than in a single value. Measurement uncertainty depends on the measurement system only. Digital measurements have very small uncertainty, frequently smaller than the range of true experimental values resulting from built-in differences in the experiment repetitions. When data from one–of–a kind experiment are analyzed, only the measurement uncertainty can be reported.

42 ENGINEERING↗

Prediction of heat transfer coefficients for forced convective boiling of N 2 -hydrocarbon mixtures at cryogenic conditions using artificial neural networks

A key problem faced in the design of heat exchangers, especially for cryogenic applications, is the determination of convective heat transfer coefficients in two-phase flow such as condensation and boiling of non-azeotropic refrigerant mixtures. Here, this paper proposes and evaluates three models for estimating the convective coefficient during boiling. These models are developed using computational intelligence techniques. The performance of the proposed models is evaluated using the mean relative error (mre), and compared to two existing models: the modified Granryd’s correlation and the Silver-Bell-Ghaly method. The three proposed models are distinguished by their architecture. The first is based on directly measured parameters (DMP-ANN), the second is based on equivalent Reynolds and Prandtl numbers (eq-ANN), and the third on effective Reynolds and Prandtl numbers (eff-ANN). In conclusion, the results demonstrate that the proposed artificial neural network (ANN)-based approaches greatly outperform available methodologies. While Granryd's correlation predicts experimental data within a mean relative error mre = 44% and the S-B-G method produces mre = 42%, DMP-ANN has mre = 7.4% and eff-ANN has mre = 3.9%. Considering that eff-ANN has the lowest mean relative error (one tenth of previously available methodologies) and the broadest range of applicability, it is recommended for future calculations. Implementation is straightforward within a variety of platforms and the matrices with the ANN weights are given in the appendix for efficient programming.

42 ENGINEERING↗

Uncertainties and Covariances of the Fission Cross Sections and the Fission Neutron Multiplicities for Actinides

Experimental data on the fission cross sections and the fission-neutron multiplicities of actinides are analyzed on the basis of the unrecognized error-estimation method. Such an approach allows us to estimate reasonable systematic uncertainties of available data, which are underestimated by authors of most measurements as a rule. The corresponding uncertainties and covariances of evaluated data are obtained for the most important actinides in the 15-energy group representation. Differences between the present evaluations and the recent BOLNA results are discussed for the main actinides. It is shown that the fission cross section uncertainties are overestimated essentially in the BOLNA analysis for minor actinides. Uncertainties of the cross sections and the neutron multiplicities averaged over the Cf-252 fission-neutron spectrum are considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Error Analysis And Propagation In Metabolomics Data Aanalysis

Error analysis plays a fundamental role in describing the uncertainty in experimental results. It has several fundamental uses in metabolomics including experimental design, quality control of experiments, the selection of appropriate statistical methods, and the determination of uncertainty in results. Furthermore, the importance of error analysis has grown with the increasing number, complexity, and heterogeneity of measurements characteristic of ‘omics research. The increase in data complexity is particularly problematic for metabolomics, which has more heterogeneity than other omics technologies due to the much wider range of molecular entities detected and measured. This review introduces the fundamental concepts of error analysis as they apply to a wide range of metabolomics experimental designs and it discusses current methodologies for determining the propagation of uncertainty in appropriate metabolomics data analysis. These methodologies include analytical derivation and approximation techniques, Monte Carlo error analysis, and error analysis in metabolic inverse problems. Current limitations of each methodology with respect to metabolomics data analysis are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental demonstration of a data-driven control system for subcritical nuclear facility

Here this paper presents an experimental demonstration of a data-driven control system (DCS) designed for the MIT Graphite Exponential Pile (MGEP). The DCS aims to regulate the neutron flux profile such that symmetry is preserved. Neutron flux perturbations are introduced into the MGEP to test the DCS's capabilities by the movement of an initiating control rod (ICR). To realize this functionality, a control system that relies on an artificial neural network (ANN) was developed, and then demonstrated on the MGEP. A Helium-3 ( 3 He) neutron detector and dual control rods, including their moving mechanisms, were fabricated. The perturbed flux profile was monitored by the moving neutron detector. The prediction accuracy of the neural network (NN) was examined and the DCS response was presented. Our results show that neural network regression model trained by experimental data can achieve a prediction error of less than 2.5 cm with a 95% confidence interval. The demonstration experiment also shows that a perturbation of the ICR can be captured by the control system and flux symmetry can be maintained within 1% after the response of the responding control rod (RCR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Applicability of available Li-ion battery degradation models for system and control algorithm design

Within electrified vehicle powertrains, lithium-ion battery performance degrades with aging and usage, resulting in a loss in both energy and power capacity. As a result, models used for system design and control algorithm development would ideally capture the impact of those efforts on battery capacity degradation, be computationally efficient, and simple enough to be used for algorithm development. This paper provides an assessment of the state-of-the-art in lithium-ion battery degradation models, including accuracy, computational complexity, and amenability to control algorithm development. Various aging and degradation models have been studied in the literature, including physics-based electrochemical models, semi-empirical models, and empirical models. Some of these models have been validated with experimental data; however, comparisons of pre-existing degradation models across multiple experimental data sets have not been previously published. Three representative models, a 1-d electrochemical model (a combination of performance model and degradation model), a semi-empirical degradation model (the performance is predicted by an equivalent circuit model) and an empirical degradation model (the performance is predicted by an equivalent circuit model), are compared against four published experimental data sets for a 2.3-Ah commercial graphite/LiFePO 4 cell. Based on simulation results and comparisons to experimental data, the key differences in the aging factors captured by each of the models are summarized. Here the results show that the physics-based model is best able to capture results across all four representative data sets with an error less than 10%, but is 20x slower than the empirical model, and 134x slower than the semi-empirical model, making it unsuitable for powertrain system design and model-based algorithm development. Despite being computationally efficient, the semi-empirical and empirical models, when used under conditions that lie outside the calibration data set, exhibit up to 71% error in capacity loss prediction. Such models require expensive experimental data collection to recalibrate for every new application. Thus, in the author’s opinion, there exists a need for a physically-based model that generalizes well across operating conditions, is computationally efficient for model-based design, and simple enough for control algorithm development.

25 ENERGY STORAGE↗

G4CEP: A G4 theory modification by including pseudopotential for molecules containing first-, second- and third-row representative elements

The G4CEP composite method was developed from the respective G4 all-electron version by considering the implementation of compact effective pseudopotential (CEP). The G3/05 test set was used as reference to benchmark the adaptation by treating in this work atoms and compounds from the first and second periods of the periodic table, as well as representative elements of the third period, comprising 440 thermochemical data. G4CEP has not reached a so high level of accuracy as the G4 all-electron theory. G4CEP presented a mean absolute error around 1.09 kcal mol{sup −1}, while the original method presents a deviation corresponding to 0.83 kcal mol{sup −1}. The similarity of the optimized molecular geometries between G4 and G4CEP indicates that the core-electron effects and basis set adjustments may be pointed out as a significant factor responsible for the large discrepancies between the pseudopotential results and the experimental data, or even that the all-electron calculations are more efficient either in its formulation or in the cancellation of errors. When the G4CEP mean absolute error (1.09 kcal mol{sup −1}) is compared to 1.29 kcal mol{sup −1} from G3CEP, it does not seem so efficient. However, while the G3CEP uncertainty is ±4.06 kcal mol{sup −1}, the G4CEP deviation is ±2.72 kcal mol{sup −1}. Therefore, the G4CEP theory is considerably more reliable than any previous combination of composite theory and pseudopotential, particularly for enthalpies of formation and electron affinities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast Correction of Errors in the DFT‐Calculated Energies of Gaseous Nitrogen‐Containing Species

Abstract Modeling adsorption phenomena on surfaces by DFT calculations often involves substantial errors, resulting in inaccurate predictions of catalytic activities. Such errors partly stem from the inaccurate description of the energetics of free molecules. Herein, we use a semiempirical group‐additivity method to correct the DFT‐calculated heats of formation of 106 carbon‐ and nitrogen‐containing gaseous compounds belonging to 15 different chemical families. PBE, PW91, RPBE and BEEF‐vdW initially yield mean absolute errors (MAEs) with respect to experiments in the range of 0.32–0.75 eV. After correcting the systematic errors, the overall MAEs decrease to ∼0.05 eV. Additionally, upon applying the corrections to three types of reaction enthalpies, the resulting MAEs are below 0.10 eV. These functional‐group corrections can be used in (electro)catalysis to correct the gas‐phase references necessary to evaluate equilibrium potentials and adsorption energies, predict error cancellation, and assess conflicting experimental data.

Urrego‐Ortiz, Ricardo↗

Investigation of Cody–Lorentz and Tauc–Lorentz Models in Characterizing Dielectric Function of (HfO{sub 2}){sub x}(ZrO{sub 2}){sub 1–x} Mixed Thin Film

In the present study, Tauc–Lorentz and Urbach tail assisted Cody–Lorentz models were intuitively derived, explained, and employed to simulate the imaginary dielectric function of the atomic layer deposited (HfO{sub 2}){sub x}(ZrO{sub 2}){sub 1–x} in the energy range of 0.7–9.3 eV. A fitting procedure is carried out using the Levenberg–Marquardt method for minimizing mean square errors. Both models support the experimental data derived by vacuum ultraviolet spectroscopic ellipsometry. For a zirconium content of 60 and 75%, a weak absorption profile is observed in the visible region and elaborately explained by the Lorentz oscillator model. In order to calculate the band gap of different compositions, Cody plots and Tauc plots are presented. The results show that the Cody–Lorentz model is more accuracy due to its exponential absorption below the band gap energy and modified density of states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantified uncertainty in thermodynamic modeling for materials design

Phase fractions, compositions and energies of the stable phases as a function of macroscopic composition, temperature, and pressure (X-T-P) are the principle correlations needed for the design of new materials and improvement of existing materials. They are the outcomes of thermodynamic modeling based on the CALculation of PHAse Diagrams (CALPHAD) approach. Here, the accuracy of CALPHAD predictions vary widely in X-T-P space due to experimental error, model inadequacy and unequal data coverage. In response, researchers have developed frameworks to quantify the uncertainty of thermodynamic property model parameters and propagate it to phase diagram predictions. In most previous studies, uncertainty was represented as intervals on phase boundaries (with respect to composition or temperature) and was unable to represent the uncertainty in invariant reactions or in the stability of phase regions. In this work, we propose a suite of tools that leverages samples from the multivariate model parameter distribution to represent uncertainty in forms that surpass previous limitations and are well suited to materials design. These representations include the distribution of phase diagrams and their features, as well as the dependence of phase stability and the distributions of phase fraction, composition, activity and Gibbs energy on X-T-P location - irrespective of the total number of components. Most critically, the new methodology allows the material designer to interrogate a certain composition and temperature domain and get in return the probability of different phases to be stable, which can positively impact materials design.

36 MATERIALS SCIENCE↗

Correction Scheme for Comparison of Computed and Experimental Optical Transition Energies in Functionalized Single-Walled Carbon Nanotubes

We present that covalent functionalization of single-walled carbon nanotubes (SWCNTs) introduces red-shifted emission features in the near-infrared spectral range due to exciton localization around the defect site. Such chemical modifications increase their potential use as near-infrared emitters and single-photon sources in telecommunications applications. Density functional theory (DFT) studies using finite-length tube models have been used to calculate their optical transition energies. Predicted energies are typically blue-shifted compared to experiment due to methodology errors including imprecise self-interaction corrections in the density functional and finite-size basis sets. Furthermore, artificial quantum confinement in finite models cannot be corrected by a constant-energy shift since they depend on the degree of exciton localization. Herein, we present a method that corrects the emission energies predicted by time-dependent DFT. Confinement and methodology errors are separately estimated using experimental data for unmodified tubes. Finally, corrected emission energies are in remarkable agreement with experiment, suggesting the value of this straightforward method toward predicting and interpreting the optical features of functionalized SWCNTs.

36 MATERIALS SCIENCE↗