Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Absorption profile of a planetary atmosphere - A proposal for a scattering independent determination.

The use of scattering theory to infer atmospheric optical parameters requires the separation of absorption and scattering. It is demonstrated that a gradient flux relation exists that would provide the absorption (altitude) profile independently of scattering and irrespective of the state of polarization of the light field. The relation is derived for an atmosphere of plane-parallel or spherical geometry and for broad (continuum) and narrow (spectral line) frequency bands. The results are shown to hold, in particular, for the polarizations induced by both Rayleigh and Mie scattering in the field. Experimental setups are proposed for each of the cases considered of atmospheric geometry and frequency bandwidth.

Fymat, A. L.↗

Contributions to the problem of piezoelectric accelerometer calibration

After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

Jakab, I.↗

Observations on some acoustic methods used in studying the elastic properties of metals

An experimental setup is reported that permits very accurate measurements of the resonance frequencies of long cylindrical beams fixed in the middle and whose size can vary within wide limits. It also permits measurement of the width of the resonance curve. It is shown that the Poisson effect can be brought to light for relatively long beams and for relatively short beams. Poisson ratio, values obtained with this method argue in favor of using the low frequency region for determining elastic constants of solids.

Velceanu, C. I.↗

Microbial detection method based on sensing molecular hydrogen

An approach involving the measurement of hydrogen evolution by test organisms was used to detect and enumerate various members of the Enterobacteriaceae group. The experimental setup for measuring hydrogen evolution consisted of a test tube containing two electrodes plus broth and organisms. The test tube was kept in a water bath at a temperature of 35 C. It is pointed out that the hydrogen-sensing method, coupled with the pressure transducer technique reported by Wilkins (1974) could be used in various experiments in which gas production by microorganisms is being measured.

Wilkins, J. R.↗

Soft X-ray detection with the Fairchild 100 by 100 CCD

The soft X-ray sensitivity of the Fairchild 100 x 100 element CCD is studied for possible use as a detector in plasma physics research. The experimental setup and laboratory results are reported including data on slow scan operation of the CCD and performance when cooled. Results from digital computer processing of the data to correct for element-to-element nonuniformities are also discussed.

Renda, G.↗

A computer program for the localization of small areas in roentgenological images

A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positioning accuracy on the operator's part. The rapidity of measurement allows results to be evaluated on-line. Parameters associated with the algorithm have been analyzed, and methods to facilitate an optimum choice for any particular experimental setup are presented.

Keller, R. A.↗

Measurements on wave propagation characteristics of spiraling electron beams

Dispersion characteristics of cyclotron-harmonic waves propagating on a neutralized spiraling electron beam immersed in a uniform axial magnetic field are studied experimentally. The experimental setup consisted of a vacuum system, an electron-gun corkscrew assembly which produces a 110-eV beam with the desired delta-function velocity distribution, a measurement region where a microwave signal is injected onto the beam to measure wavelengths, and a velocity analyzer for measuring the axial electron velocity. Results of wavelength measurements made at beam currents of 0.15, 1.0, and 2.0 mA are compared with calculated values, and undesirable effects produced by increasing the beam current are discussed. It is concluded that a suitable electron beam for studies of cyclotron-harmonic waves can be generated by the corkscrew device.

Singh, A.↗

High-sampling-rate pressure transducer has in situ calibration

High-data-rate pressure sensor module can be calibrated after it is attached to an experimental setup. Electrically multiplexed sensor is designed for use in wind-tunnels and other applications requiring accurate measurement of many pressures in a short period of time.

Gross, C.↗

Multichannel electrochemical microbial detection unit

The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.

Wilkins, J. R.↗

Fresnel drag effect in fiber optic gyroscope

Consideration is given to the development of a low-noise fiber-optic ring interferometer gyroscope. A technique for measuring the Fresnel drag coefficient of optical fibers is described, and the accuracy of the technique is considered. An experiment is performed which allows verification of the Einstein velocity addition theorem to the first nonlinear term. An experimental setup for measuring Fresnel drag is described: it consists of a Sagnac interferometer and a Fresnel drag measurement configuration.

Vali, V.↗

Scale model studies for establishing the flow patterns of a low-speed tunnel

Experiments were conducted in a model tunnel scaled down in a ratio of 1:24 from the full size prototype V/STOL tunnel at NASA Langley Research Center. The flow characteristics around the tunnel were studied and the location and causes of local flow separation and local recirculation were documented. The study of the interaction between the various components from which the tunnel is built, an experimental setup similar to the sequence of tunnel circuit components was constructed which enabled the various components to be tested either individually or in combination. The components were tested by the simple technique of blowing air through them, then measuring the velocity distribution at relevant sections.

Barna, P. S.↗

Comparison of the early stages of condensation of Cu and Ag on Mo/100/ with Cu and Ag on W/100/

The adsorption and condensation of Cu and Ag, up to several monolayers in thickness, onto Mo(100) has been observed at pressures below 2 times 10 to the -10th torr in a study that used combined LEED, Auger, TDS (Thermal Desorption Spectroscopy), and work function measurements in a single experimental setup. The results show that Cu behaves similarly on Mo(100) and W(100) substrates, while some differences are found for Ag adsorption.

Soria, F.↗

Positron annihilation studies of moisture in graphite-reinforced composites

The positron lifetime technique of monitoring absorbed moisture is applied to several composites, including graphite/polymides which are candidates for high-temperature (over 260 C) applications. The experimental setup is a conventional fast-slow coincidence system wherein the positron lifetime is measured with respect to a reference time determined by the detection of a nuclear gamma ray emitted simultaneously with the positron. From the experiments, a rate of change of positron mean lifetime per unit mass of water can be determined for each type of specimen. Positron lifetime spectra are presented for a graphite/polyimide composite and for a pure polyimide.

Singh, J. J.↗

Flying qualities criteria for GA single pilot IFR operations

The flying qualities criteria in general aviation (GA) to decrease accidents are discussed. The following in-flight research is discussed: (1) identification of key aerodynamic configurations; (2) implementation of an in-flight simulator; (3) mission matrix design; (4) experimental systems; (5) data reduction; (6) optimal flight path reconstruction. Some of the accomplished work is reported: an integrated flight testing and flight path reconstruction methodology was developd, high accuracy in trajectory estimation was achieved with an experimental setup, and a part of the flight test series was flown.

Bar-Gill, A.↗

Results of a flight experiment on the catalytic efficiency of the Space Shuttle heat shield

An experiment was performed on the second Space Shuttle flight to verify data from arc-heated wind-tunnel tests indicating that the thermal protection tiles used on the Shuttle's surface are noncatalytic to the recombination of dissociated air. The experiment indicates that the tiles are indeed noncatalytic, and explains the lower than expected temperatures observed in the first two Shuttle flights. The data are reasonably well predicted with computations, using a chemically reactive boundary-layer code. The experimental setup and the computational analysis are described.

Rakich, J. V.↗