Search NASA⌕ Search

SEARCH · Search NASA

Results for “explosives detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance Assessment of the CTBTO Noble Gas Network to Detect Nuclear Explosions

Atmospheric radioxenon levels are monitored worldwide by the Comprehensive Nuclear-Test-Ban Treaty Organisation (CTBTO) to detect emissions from nuclear explo-sions. Our paper examines the global network that has been set up to take routine air samples and to determine the atmospheric radioxenon concentrations. It is hypothesised that the monitoring system aims at the detection and localisation of radioxenon relea-ses. Both capabilities are dependent on background levels, explosive yields, leakage rates, transport time, choice of xenon isotope and number and locations of monitoring stations. And for each parameter, the global capabilities to detect and localise emissions from nuclear explosions are analysed. Recommendations for the future of the background sources and the development of the monitoring system are derived.

54 ENVIRONMENTAL SCIENCES↗

Accelerator-Detector Complex for Photonuclear Detection of Hidden Explosives

This was a collaborative effort by Lawrence Livermore National Security (formerly the University of California)/Lawrene Livermore National Laboratory (LLNL), Valley Forge Composite Technologies, Inc., and the following Russian Institutes: P. N. Lebedev Physical Institute (LPI), Innovative Technologies Center (AUO CIT), Central Design Bureau-Almas (CDB Almaz), Moscow Instrument Automation Research Institute, and Institute for High Energy Physics (IHEP) to develop equipment and procedures for detecting explosive materials concealed in airline checked baggage and cargo. The technical objectives of this CRADA project were: to develop, miniaturize, and automate the accelerator-detector complex for high efficiency detection of hidden explosives; software was also to be developed to run the explosives detection system and acquire and process data; and work was to be done to evaluate the signatures produced by the explosives detection system and evaluate its ability to detect explosives in checked baggage.

Lowdermilk, W. Howard↗

Ultra-Trace and Vapor Detection of Explosives and Narcotics Finalist for R&D 100 Award

An instrument more sensitive than a canine’s nose identifies explosives and narcotics vapors in real time and at levels previously undetectable than any other sampling technology. The instrument is one among five PNNL-developed technologies in the running for an R&D 100 Award. Known as VP-IDENT, the tool coupled with a mass spectrometer, is ideal for aviation security, cargo screening, and broader counter-terrorism and national security activities where discovering dangerous substances is of utmost importance. Listen as researcher Robert Ewing explains.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Explosives tester

An explosives tester that can be used anywhere as a screening tool by non-technical personnel to determine whether a surface contains explosives. First and second explosives detecting reagent holders and dispensers are provided. A heater is provided for receiving the first and second explosives detecting reagent holders and dispensers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Improved explosive collection and detection with rationally assembled surface sampling materials

Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

Explosive detection↗

Advances in explosives analysis—part II: photon and neutron methods

The number and capability of explosives detection and analysis methods have increased dramatically since publication of the Analytical and Bioanalytical Chemistry special issue devoted to Explosives Analysis [Moore DS, Goodpaster JV, Anal Bioanal Chem 395:245–246, 2009]. Here we review and critically evaluate the latest (the past five years) important advances in explosives detection, with details of the improvements over previous methods, and suggest possible avenues towards further advances in, e.g., stand-off distance, detection limit, selectivity, and penetration through camouflage or packaging. Our review consists of two parts. Part I discussed methods based on animals, chemicals (including colorimetry, molecularly imprinted polymers, electrochemistry, and immunochemistry), ions (both ion-mobility spectrometry and mass spectrometry), and mechanical devices. In Part II, we review methods based on photons, from very energetic photons including X-rays and gamma rays down to the terahertz range, and neutrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Receiver Operating Characteristic Analysis for Detecting Explosives-related Threats

The Department of Homeland Security (DHS) and the Transportation Security Administration (TSA) are interested in developing a standardized testing procedure for determining the performance of candidate detection systems. This document outlines a potential method for judging detection system performance as well as determining if combining the information from a legacy system with a new system can significantly improve performance. In this document, performance corresponds to the Neyman-Pearson criterion applied to the Receiver Operating Characteristic (ROC) curves of the detection systems in question. A simulation was developed to investigate how the amount of data provided by the vendor in the form of the ROC curve effects the performance of the combined detection system. Furthermore, the simulation also takes into account the potential effects of correlation and how this information can also impact the performance of the combined system.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Colorimetric chemical analysis sampler for the presence of explosives

A tester for testing for explosives comprising a body, a lateral flow swab unit operably connected to the body, a explosives detecting reagent contained in the body, and a dispenser operatively connected to the body and the lateral flow swab unit. The dispenser selectively allows the explosives detecting reagent to be delivered to the lateral flow swab unit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Colorimetric chemical analysis sampler for the presence of explosives

A tester for testing for explosives comprising a body, a lateral flow swab unit operably connected to the body, a explosives detecting reagent contained in the body, and a dispenser operatively connected to the body and the lateral flow swab unit. The dispenser selectively allows the explosives detecting reagent to be delivered to the lateral flow swab unit.

47 OTHER INSTRUMENTATION↗

PINS Measurements and Simulations for Stand-Off Detection of High Explosives

There has been some interest in the ability of Idaho National Laboratory's (INL) Portable Isotopic Neutron Spectroscopy System's (PINS) ability to detect high explosives at a distance. In order to assess the system's ability to perform this task, laboratory experiments on simulated or mock explosives and Monte Carlo simulations using MCNP on both mock and real explosives have been performed. The simulations and experiments on mock explosives have essentially identical configurations, allowing the models to be confirmed with experiment. This provides greater confidence in the simulations on real explosives without the need for experiment on live explosives.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nitrogen-Activated Oxidation in Nitrogen Direct Analysis in Real Time Mass Spectrometry (DART-MS) and Rapid Detection of Explosives Using Thermal Desorption DART-MS

Direct analysis in real time mass spectrometry (DART-MS) was used to analyze an array of explosives including nitro-based explosives, peroxide explosives, and energetic heterocyclic compounds with different DART discharge gases (helium, argon, and nitrogen). Profound analyte oxidation was observed for particular compounds (TNT (9) and 2, 4-DNT (10)), whose mass spectra were completely dominated by the oxidation products when nitrogen was substituted for helium in DART analysis. This interesting phenomenon suggested that a highly oxidative environment provided by N{sub 2} DART ion source. A possible mechanism involved in nitrogen DART was proposed which may help further understanding the different chemistry involved in the ionization process. This work also presents a thermal desorption DART (TD-DART) configuration that can enable rapid, specific analysis of explosives from swipes. The screening of swipes with three different compositions (fiberglass, Hybond N{sup +} membrane, and filter paper) showed that fiberglass swipe has the best performance which was then used for the subsequent TD-DART analysis. A direct comparison of TD-DART with traditional DART demonstrated that TD-DART indeed gives better response than traditional DART (provided that the distance between the DART source and mass spectrometer is the same) and will have wider applications than traditional DART. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final CRADA Report: Evaluation of Trace Particle Removal Techniques for Enhanced Detection of Explosives in Air Cargo

This report describes the procedures used and the test results obtained at the Idaho National Laboratory (INL), to determine the ability of thermal and mechanical (vibration and airflow) methods to remove/harvest trace explosives from various material substrate surfaces relevant to air cargo. As part of the Battelle Memorial Institute’s (BMI) Air Cargo Screening (ACS) Initiative, INL conducted mechanical and thermal/mechanical removal tests using three different military explosives: C-4(RDX), cast TNT, and SEMTEX (PETN, 76% and RDX, 4.6%) on two substrate materials relevant to air cargo: metal and cardboard. This work leveraged similar experiments using homemade explosives (HME) which were funded by the Department of Homeland Security’s Science and Technology Directorate (DHS S&T). The DHS S&T tests involved evaluating the removal efficiencies of thermal and mechanical methods for four different HME: Ammonium Nitrate prills (AN, explosive grade), Guanidine Nitrate (GN, 98% pure in Methanol), Triacetone Triperoxide (TATP, 99.5% pure in Acetonitrile), and Hexamethylene Triperoxide Diamine (HMTD, 98.4% pure in Acetonitrile). Substrate materials used for the HME removal tests included metal, cotton, canvas, leather, shrink wrap, cardboard, and vinyl. This report documents the procedures that were used during the testing as well as the test results and recommendations for future Air Cargo Screening applications.

Source record↗

Negative ion spectrometry for detecting nitrated explosives

Ionization procedure is modified to produce mainly negative ions by electron capture. Peaks of negative ions are monitored conventionally. Nitrated organic materials could be identified directly from sample sniff inlet stream by suitably modified mass spectrometer because of unique electronegativity which nitro group imparts to organic material.

Boettger, H. G.↗