Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sub-ply level scaling approach investigated for graphite-epoxy composite beam columns

Scale model graphite-epoxy composite specimens were fabricated using the 'sub-ply level' approach and tested as beam-columns under an eccentric axial load to determine the effect of specimen size on flexural response and failure. In the current research project, although the fiber diameters are not scaled, the thickness of the pre-preg material itself has been scaled by adjusting the number of fibers through the thickness of a single ply. Three different grades of graphite-epoxy composite material (AS4/3502) were obtained from Hercules, Inc., in which the number of fibers through the thickness of a single ply was reduced (Grade 190 with 12 to 16 fibers, Grade 95 with 6 to 8 fibers, and Grade 48 with 3 to 4 fibers). Thus, using the sub-ply level approach, a baseline eight ply quasi-isotropic laminate could be fabricated using either the Grade 48 or Grade 95 material and the corresponding full-scale laminate would be constructed from Grade 95 or standard Grade 190 material, respectively. Note that in the sub-ply level approach, the number of ply interfaces is constant for the baseline and full-scale laminates. This is not true for the ply level and sublaminate level scaled specimens. The three grades of graphite-epoxy composite material were used to fabricate scale model beam-column specimens with in-plane dimensions of 0.5*n x 5.75*n, where n=1,2,4 corresponsing to 1/4, 1/2, and full-scale factors. Angle ply, cross ply, and quasi-isotropic laminate stacking sequences were chosen for the investigation and the test matrices for each laminate type are given. Specimens in each laminate family with the same in-plane dimensions but different thicknesses were tested to isolate the influence of the thickness dimension on the flexural response and failure. Also, specific lay-ups were chosen with blocked plies and dispersed plies for each laminate type. Specimens were subjected to an eccentric axial load until failure. The load offset was introduced through a set of hinges which were attached to the platens of a standard load test machine. Three sets of geometrically scaled hinges were used to ensure that scaled loading conditions were applied. This loading condition was chosen because it promotes large flexural deformations and specimens fail at the center of the beam, away from the grip supports. Five channels of data including applied vertical load, end shortening displacement, strain from gages applied back-to-back at the midspan of the beam, and rotation of the hinge from a bubble inclinometer were recorded for each specimen. The beam-column test configuration was used previously to study size effects in ply level scaled composite specimens of the same material system, sizes, and stacking sequences. Thus, a direct comparison between the two scaling approaches is possible. Ply level scaled beam-columns with angle ply, cross ply, and quasi-isotropic lay-ups exhibited no size dependencies in the flexural response, but significant size effects in strength. The reduction in strength with increasing specimen size was not predicted successfully by analysis techniques. It is anticipated that results from this investigation will lead to a better understanding of the strength scale effect in composite structures.

Jackson, Karen E.↗

STS-3 main parachute failure

A failure analysis of the parachute on the Space Transportation System 3 flight's solid rocket booster's is presented. During the reentry phase of the two Solid Rocket Boosters (SRBs), one 115 ft diameter main parachute failed on the right hand SRB (A12). This parachute failure caused the SRB to impact the Ocean at 110 ft/sec in lieu of the expected 3 parachute impact velocity of 88 ft/sec. This higher impact velocity relates directly to more SRB aft skirt and more motor case damage. The cause of the parachute failure, the potential risks of losing an SRB as a result of this failure, and recommendations to ensure that the probability of chute failures of this type in the future will be low are discussed.

Runkle, R.↗

Equibiaxial flexural strength determination of UO 2 using a ball-on-ring test

To increase nuclear fuel performance and reliability, their mechanical properties require an accurate and statistically relevant assessment. Biaxial flexural strength tests provide an alternative to bend bar techniques for assessing mechanical behavior; namely, the transverse rupture strength (TRS) of ceramic samples. Biaxial test samples require simple geometries and minimal surface preparation, reducing fabrication costs and handling hazards. This study investigated the TRS of polycrystalline UO 2 fuel forms at room temperature using a ball-on-ring test fixture. Here, pellets were fabricated from UO 2 powder using conventional powder processing and sintering techniques. The TRS and Weibull parameters were obtained through Weibull statistics on over 60 UO 2 samples tested under equibiaxial flexure. The larger sample size in this study enabled a more robust Weibull statistical analysis than alternative test methods, which may not capture the stochastic failure of typical ceramics. Furthermore, two different loading ball diameters were employed to assess the impact of contact damage on fracture strength. While Hertzian contact damage was observed with the smaller loading ball, the fracture strength remained unaffected. A fracture analysis of the tested UO 2 samples indicated a mixture of intergranular and transgranular fracture that transitions to transgranular fracture with increasing distance from the fracture origin. The characteristic strength of the combined data sets was determined to be 148 MPa, and the Weibull modulus was determined to be 9.1. The TRS values and Weibull parameters were close to values found in the literature for alternative testing techniques using samples with similar microstructure and density. The findings in this study validate the ball-on-ring method used to obtain the TRS of UO 2 with a sample geometry more representative of nuclear fuels. Additionally, experimental TRS results from this study can be implemented in modeling codes to predict fuel performance, which is critical to fuel burnup extension and advanced nuclear fuel technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Creep-rupture tests of internally pressurized Rene 41 tubes

Weld-drawn tubes of Rene 41 with 0.935 centimeter outside diameter and 0.064 centimeter wall thickness were tested to failure at temperatures from 1117 to 1233 K and internal helium pressures from 5.5 to 12.4 meganewtons per square meter. Lifetimes ranged from 5 to 2065 hours. The creep-rupture strength of the tubes was 50 percent lower than that of unwelded, thick sheet specimens, and 20 percent lower than that of unwelded, thin sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

Gumto, K. H.↗

Creep-rupture tests of internally pressurized Inconel 702 tubes

Seamless Inconel 702 tubes with 0.375-in. outside diameter and 0.025-in. wall thickness were tested to failure at temperatures from 1390 to 1575 F and internal helium pressures from 700 to 1800 psi. Lifetimes ranged from 29 to 1561 hr. The creep-rupture strength of the tubes was about 70 percent lower than that of sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

Gumto, K. H.↗

Creep-rupture tests of internally pressurized Hastelloy-X tubes

Seamless Hastelloy-X tubes with 0.375-in. outside diameter and 0.025-in. wall thickness were tested to failure at temperatures from 1400 to 1650 F and internal helium pressures from 800 to 1800 psi. Lifetimes ranged from 58 to 3600 hr. The creep-rupture strength of the tubes was from 20 to 40 percent lower than that of sheet specimens. Larson-Miller correlations and photomicrographs of some specimens are presented.

Gumto, K. H.↗

Central peaks in lunar craters - Morphology and morphometry

Fresh lunar craters with diameters from 17 to 175 km are found to display a linear relationship between the central peak morphology and morphometry and such critical crater parameters as rim crest diameter, floor diameter, and substrate. Some other previously established linear relationships have been cited as evidence that floor diameter, peak height, and peak ring diameter are related to the kinetic energy of impact. The two new relations derived in the present work would therefore indicate that the central peaks, too, are related to the kinetic energy of impact, and probably begin to form early in the cratering event as suggested by Milton and Roddy (1972) and Head (1978). There seems to be no obvious reason to expect such linear relationships between central peak diameter and rim crest and floor diameter if the peaks are formed by gravity induced failure of the transient cavity, as suggested by Dence et al. (1968).

Hale, W.↗

Effect of fiber diameter and matrix alloys on impact-resistant boron/aluminum composites

Efforts to improve the impact resistance of B/Al are reviewed and analyzed. Nonstandard thin-sheet charpy and Izod impact tests and standard full-size Charpy impact tests were conducted on composites containing unidirectional 0.10mm, 0.14mm, and 0.20mm diameter boron fibers in 1100, 2024, 5052, and 6061 Al matrices. Impact failure modes of B/Al are proposed in an attempt to describe the mechanisms involved and to provide insight for maximizing impact resistance. The impact strength of B/Al was significantly increased by proper selection of materials and processing. The use of a ductile matrix and large diameter boron fibers gave the highest impact strengths. This combination resulted in improved energy absorption through matrix shear deformation and multiple fiber breakage.

Mcdanels, D. L.↗

Calibration of Al7075 with Plate-Puncture Predictions

The following details calibration of a material model for Al7075-T6511. This aluminum alloy is commonly used across a host of engineering applications. Owing to its widespread prevalence, there is great benefit in improving simulation predictions for this alloy. In the present effort, a calibration is performed of its elastic-plastic response accounting for both rate and temperature dependence. The calibration is informed by a series of tests that include specimens of different geometries tested at different rates and temperatures. All specimens are derived from the same barstock, 3.5 inches in diameter. The fitted model itself uses an anisotropic, Hill yield surface coupled with a Johnson-Cook hardening model. Failure predictions are had by means of a modified Wilkins failure criterion. Following calibration of the material model, a validation exercise is performed against platepuncture experiments. These experiments include multiple probe shapes, probe diameters, and plate thicknesses. The puncture experiments are replicated in simulation with mesh studies performed to assess uncertainty. Key quantities of interest, notably the absorbed energy up to failure, are compared between simulation and experiment providing a means to assess the suitability of the calibration in puncture simulations.

36 MATERIALS SCIENCE↗

Analyses of SPERT-CDC test 859 by FEMAXI-7 and RANNS codes

In the current Japanese regulation concerning fuel safety of water-cooled reactors, the criterion of fuel failure due to pellet-cladding mechanical interaction (PCMI) in a burnup range of 25-40 GWd/t is determined substantially based on the result of SPERT-CDC test 859 (SPERT859). However, there is room for discussion if the result of SPERT859 test rod with a burnup of 31.8 GWd/t represents the failure behavior of the fuel rod for commercial light water reactor because it was reported in some literatures that the cladding of SPERT859 test rod corroded excessively during pre-irradiation. On the other hand, the oxide thickness on the cladding of SPERT859 test rod was not reported in the data of its post-irradiation examinations (PIEs) after pre-irradiation, and the probability of the excessive corrosion on the cladding of the test rod and the effect of such excessive corrosion on the fuel enthalpy at failure of the test rod has not yet been clarified. In this study, the oxide thickness of the cladding formed on the cladding outer surface of SPERT859 test rod and its fuel enthalpy at failure due to PCMI under this corrosion condition were analyzed by using fuel performance codes FEMAXI-7 and RANNS. From the analysis results of FEMAXI-7, it was found that the excessive corrosion of the cladding of the test rod should be assumed to reproduce the fuel outer diameter measured in PIEs after pre-irradiation. The fuel enthalpy at failure of the test rod was calculated by using RANNS, and the calculated fuel enthalpy at failure was relatively close to the value of SPERT859 test rod. These results suggested that the fuel enthalpy at failure of SPERT859 was affected by the excessive corrosion on the cladding of the test rod and was likely lower than that of the typical fuel for light water reactors. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isogrid structures

Test results and related structural instability analyses are presented for a 10-foot-diameter, 37-inch-long cylinder, and a 10-foot-diameter, 40-inch-long, 45-degree conical frustum. Both structures are based upon flanged isogrids and are fabricated in 2024-T851 aluminum. Peak edge load intensities at failure were 1,654 lb/in for the cylinder and 1,457 lb/in at the small diameter of the frustum. General instability cylindrical-monocoque-structure equivalent knockdown factors for both were in good agreement (gamma = 0.48). Design analysis is also derived for estimating critical cylinder instability edge loads from the performance of two tandem isogrid members. Evaluation is made of effective skin contributing to isogrid load-carrying cross-section.

Slysh, P.↗

van der Waals forces: Accurate calculation and assessment of approximate methods in delectric nanocolloids up to 16nm

A microscopic method is used to calculate the van der Waals forces between large nanocolloids. We assess the reliability of some predictions derived from the most commonly used macroscopic method in practice, the Dzyaloshinskii-Lifshitz-Pitaevskii (DLP) theory combined with the Derjaguin approximation, by calculating them using the “coupled dipole method” (CDM). The CDM, which has demonstrated its ability to calculate VDW interactions for small-nanoclusters, accounts for all many-body forces, and it does not assume a continuous, homogeneous dielectric function in each material. It is shown that, out of three explored, one of the routinely assumed properties (‘small-separation dominance’) of van der Waals forces predicted from the macroscopic method is generally applicable for large spherical dielectric nanoclusters of diameter 16 nm allowing much more efficient CDM calculations. The failure of two other routinely assumed properties, ‘infinite- depth approximation’ and ‘sphere-cube analogy’, demonstrates that the effect of finite-size and shape is important in nanocolloid systems even at the large size of 16nm.

36 MATERIALS SCIENCE↗

SpectralFly: Ramanujan Graphs as Flexible and Efficient Interconnection Networks

In recent years, graph theoretic considerations have become increasingly important in the design of HPC interconnection topologies. One approach is to seek optimal or near-optimal families of graphs with respect to a particular graph theoretic property, such as diameter. For example, the SlimFly topology is based on a construction of McKay, Miller, and \v{S}ir\'{a}\v{n} which produces a diameter two graph on a number of nodes approaching the Moore bound, i.e. the largest possible diameter two graph with a fixed radix. Motivated by recent work of Aksoy, Bruillard, Young, and Raugas, we consider topologies which optimize the spectral gap rather than the diameter. In particular, we introduce a novel HPC topology, SpectralFly, designed around the Ramanujan graph construction of Lubotzky, Phillips, and Sarnak (LPS). In this work, we show that the combinatorial properties, such as diameter, bisection bandwidth, average path length, and resilience to link failure, of SpectralFly topologies are better than, or comparable to, similarly constrained DragonFly, SlimFly, and BundleFly topologies. Additionally, we simulate the performance of SpectralFly topologies on a representative sample of physics-inspired HPC workloads using the Structure Simulation Toolkit Macroscale Element Library simulator and demonstrate considerable benefit to using LPS construction as the basis of the SpectralFly topology.

graphs and networks, network topology, interconnec↗

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE↗

Failure mechanisms of uni-ply composite plates with a circular hole under static compressive loading

The objective of the study was to identify and study the failure mechanisms associated with compressive-loaded uniply graphite/epoxy square plates with a central circular hole. It is found that the type of compressive failure depends on the hole size. For large holes with the diameter/width ratio exceeding 0.062, fiber buckling/kinking initiated at the hole is found to be the dominant failure mechanism. In plates with smaller hole sizes, failure initiates away from the hole edge or complete global failure occurs. Critical buckle wavelengths at failure are presented as a function of the normalized hole diameter.

Khamseh, A. R.↗

Compression behavior of graphite-thermoplastic and graphite-epoxy panels with circular holes or impact damage

An experimental investigation of the compression behavior of laminated specimens made from graphite-epoxy tape, graphite-thermoplastic tape and graphite-thermoplastic fabric was conducted. Specimens with five different stacking sequences were loaded to failure in uniaxial compression. Some of the specimens had central circular holes with diameters up to 65 percent of the specimen width. Other specimens were subjected to low speed impact with impact energies up to 35 J prior to compressive loading. This investigation indicates that graphite-thermoplastic specimens with holes have up to 15 percent lower failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and hole size. However, graphite-thermoplastic specimens subjected to low speed impact have up to 15 percent higher failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and impact energy. Compression tests of graphite-thermoplastic specimens constructed of unidirectional tape and fabric indicate that the material form has little effect on failure strains in specimens with holes or low speed impact damage.

Jegley, Dawn C.↗

Compression behavior of graphite-epoxy and graphite-thermoplastic panels with circular holes or impact damage

An experimental investigation of the compression behavior of laminated specimens made from graphite-epoxy tape (AS4-3502), graphite-thermoplastic tape (AS4-PEEK), and graphite-thermoplastic fabric (AS4-PEEK) was conducted. Specimens with five different stacking sequences were loaded to failure in uniaxial compression. Some of the specimens had central circular holes with diameters up to 65 percent of the specimen width. Other specimens were subjected to low speed impact with impact energy up to 30 J prior to compressive loading. This investigation indicates that graphite-thermoplastic specimens with holes have up to 15 percent lower failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and hole size. However, graphite-thermoplastic specimens subjected to low speed impact have up to 15 percent higher failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and impact energy. Compression tests of graphite-thermoplastic specimens constructed of unidirectional tape and of fabric indicate that the material form has little effect on failure strains in specimens with holes or low speed impact damage.

Jegley, Dawn C.↗