Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Fast Algorithm for Scanning Transmission Electron Microscopy Imaging and 4D-STEM Diffraction Simulations

Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.

97 MATHEMATICS AND COMPUTING↗

Mechanical characterization of fine-grain dispersion-strengthened tungsten as a plasma facing material

Field-Assisted Sintering Technology (FAST) was used to produce fine-grained, dispersion-strengthened tungsten (W) materials. Investigated materials 4138, 4353, and 4355 composed of 3 wt% ZrC sintered at 1800 °C, 5 wt% ZrC sintered at 1800 °C, and 3 wt% ZrC sintered at 2000 °C, respectively. They were compared against ITER-grade W. A series of mechanical and thermal property testing and microstructure studies were conducted to study them as a potential plasma facing material (PFM) for fusion reactors. Hardness testing showed that manufacturing conditions substantially altered hardness. Material 4355 had an average HV10 value of 497.2 ± 16.8, slightly higher than ITER-grade at 378.5 ± 40.3. However, material 4353 was substantially higher with an HV10 value of 738.9 ± 31.7 over the investigated temperature range. Electron Backscatter Diffraction (EBSD) analysis showed that FAST produced substantially smaller grains than the hot-rolled ITER-grade W material, offering notable control over grain size. Materials 4353 and 4355 had grain sizes of 0.44 ± 0.20 µm and 3.67 ± 0.89 µm, respectively, whereas ITER-grade 27.14 ± 19.76 µm at room temperature. The fine grain structures showed no net coarsening after 1 hr. anneals up to 1800 °C, several hundred degrees above the 1100 – 1500 °C recrystallization range reported for conventional W. Inverse application of the Zener pinning relationship to the measured grain sizes indicates that these two FAST sintering conditions produce markedly different effective dispersoid populations, with effective particle diameters of approximately 90 nm at a peak sintering temperature of 1800 °C and approximately 460 nm at 2000 °C, respectively. This result demonstrates that the FAST thermal condition itself, and not the nominal ZrC content alone, governs the pinning effectiveness of the dispersion. Thermal diffusivity measurements support this finding independently. Materials of identical composition sintered at different temperatures differ by approximately 19% in measured thermal diffusivity with statistically indistinguishable density, while materials of different composition and sintering temperature converge to within approximately 2%. At a representative divertor heat flux of 10 MW/m², the lower thermal conductivity of the fine-grained materials corresponds to approximately 28 to 33 °C per millimeter of armor thickness relative to ITER-grade W, traded against a substantially larger margin to recrystallization-driven degradation. While high temperature tensile testing revealed likely contamination that motivates refinement of the manufacturing process, FAST-produced, fine-grained, dispersion-strengthened W offers process-controlled microstructural stability well above the operating temperatures of conventional W and supports its continued development as a PFM for economically viable commercial fusion power.

Parker, Gabe [ORNL] (ORCID:0000000190394100)↗

Energy Storage in Metallic Glasses via Flash Annealing

Abstract When the temperature rises in a kinetically frozen and out‐of‐equilibrium system, such as a structural glass, thermal activation usually drives a relaxation to a lower enthalpy state. This is the essence of the ubiquitous thermal ageing of glassy materials below the glass transition temperature. Here, it is shown that an ultrafast temperature rise without subsequent quenching can elevate the system to a higher enthalpy state, thereby erasing the relaxation history. The key of this temperature‐driven rejuvenation is a fast‐heating rate (flash annealing) that brings the glass into a temperature regime above the glass transition within less than a millisecond. Here, the structure is entropically driven towards the liquid state, lowering its free energy, but raising its enthalpy. Subsequent cooling freezes the increased enthalpy before the liquid state is reached, thereby leading to a global energy storage. This ultrafast rejuvenation process is demonstrated for a Zr‐based metallic glass, combining calorimetry, fast in‐situ X‐ray diffraction, and atomistic simulations, showing a tenfold increase in stored enthalpy via flash annealing.

Küchemann, Stefan↗

Synthesis and Crystal Structure Study of 2’-Se-Adenosine-Derivatized DNA

The selenium derivatization of nucleic acids is a novel and promising strategy for 3D structure determination of nucleic acids. Selenium can serve as an excellent anomalous scattering center to solve the phase problem, which is one of the two major bottlenecks in macromolecule X-ray crystallography. The other major bottleneck is crystallization. It has been demonstrated that the incorporated selenium functionality at the 2'-positions of the nucleosides and nucleotides is stable and does not cause significant structure perturbation. Furthermore, it was observed that the 2'-Se-derivatization could facilitate crystallization of oligonucleotides with fast crystal growth and high diffraction quality. Herein, we describe a convenient synthesis of the 2'-Se-adenosine phosphoramidite, and report the first synthesis and X-ray crystal structure determination of the DNA containing the 2'-Se-A derivatization. The 3D structure of 2'-Se-A-DNA decamer [5'-GTACGCGT(2'-Se-A)C-3']{sub 2} was determined at 1.75 {angstrom} resolution, the 2'-Se-functionality points to the minor groove, and the Se-modified and native structures are virtually identical. Moreover, we have observed that the 2'-Se-A modification can greatly facilitate the crystal growth with high diffraction quality. In conjunction with the crystallization facilitation by the 2'-Se-U and 2'-Se-T, this novel observation on the 2'-Se-A functionality suggests that the 2'-Se moiety is sole responsible for the crystallization facilitation and the identity of nucleobases does not influence the crystal growth significantly.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating the grain-scale deformation behavior of a single-phase FCC high entropy alloy using synchrotron high energy diffraction microscopy

We report although the deformation behavior of high-entropy alloys (HEAs) has been extensively studied at the macroscale, many important properties have yet to be explored for these alloys at the microscale, thus hampering accurate prediction of damage and failure processes. Synchrotron high-energy diffraction microscopy (HEDM) and fast-Fourier transform-based crystal plasticity modeling was conducted to investigate the three-dimensional (3D) grain-resolved micromechanical response for approximately 1,900 constituent grains within a single-phase FCC HEA up to 1% applied strain. The evolution of grain-resolved elastic strains, lattice reorientations, and maximum resolved shear stresses (mRSS) were evaluated to quantify elastic, yield, and fully plastic behavior. Overall, the initial critical resolved shear stress (CRSS), determined via in situ HEDM and companion modeling, was found to be > 20% higher than estimated using the classical polycrystalline Taylor factor (M = 3.06). However, a descriptive parameter based on the average grain-resolved Taylor factor ($\overline{M}$) was found to show excellent agreement with plastic yielding behavior observed within HEDM datasets. Noticeable deviations in HEDM lattice reorientations compared to both EVP-FFT simulations and classical predictions for FCC polycrystals were discovered, highlighting the complexity in correlating local lattice reorientations, Taylor, and Schmid factors with plastic response for this material at the grain-scale. Therefore, it is anticipated that the overall trends and parameter identification of 3D grain-resolved properties in this study can serve as an important foundation for continued mesoscale investigation on both well-established and newly developed Cantor-like HEAs.

36 MATERIALS SCIENCE↗

Multi-modal characterization of the B2 phase in the Ta-Re binary system

The energy and transportation industries demand materials that retain their mechanical property at high temperatures. Refractory complex concentrated alloys (RCCAs) with a BCC + B2 microstructure offer a potential solution, where maintaining the high temperature mechanical properties can be achieved by precipitation strengthening. This depends on the B2 phase in RCCAs being thermodynamically stable with a high solvus temperature. Recently, we predicted the high temperature stability of the B2 structure in the Ta-Re binary system, using density functional theory. Here, in this study, we provide experimental evidence for the existence of this phase for the first time, using a Ta 65 Re 35 alloy. Despite Ta-Re binary phase diagrams predicting a single-phase BCC microstructure for Ta 65 Re 35 , we show that a high Z nanoscale secondary phase appears after heat treatment at 1550 °C and 1100 °C. Scanning transmission electron microscopy (STEM) revealed that this phase has a cubic structure and is equiatomic TaRe though B2 superlattice reflections were absent in fast Fourier transforms (FFT) and diffraction patterns (DPs). DP simulations indicate that the B2 TaRe superlattice reflections are up to two orders of magnitude weaker than their fundamental reflections, making their detection challenging via electron microscopy. Neutron diffraction confirmed the second phase had a B2 structure. This study identified a previously unobserved high temperature stable B2 phase in the Ta-Re system, enabling the development of new high temperature BCC + B2 RCCAs.

36 MATERIALS SCIENCE↗

Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope

We report the ability to image light elements in both crystalline and noncrystalline materials at near atomic resolution with an enhanced contrast is highly advantageous to understand the structure and properties of a wide range of beam sensitive materials including biological specimens and molecular hetero-structures. This requires the imaging system to have an efficient phase contrast transfer at both low and high spatial frequencies. Here, we introduce a new phase contrast imaging method in a scanning transmission electron microscope (STEM) using a pre-specimen phase plate in the probe forming aperture, combined with a fast pixelated detector to record diffraction patterns at every probe position, and phase reconstruction using ptychography. The phase plate significantly enhances the contrast transfer of low spatial frequency information, and ptychography maximizes the extraction of the phase information at all spatial frequencies. In addition, the STEM probe with the presence of the phase plate retains its atomic resolution, allowing simultaneous incoherent Z-contrast imaging to be obtained along with the ptychographic phase image. An experimental image of Au nanoparticles on a carbon support shows high contrast for both materials. Multislice image simulations of a DNA molecule shows the capability of imaging soft matter at low dose conditions, which implies potential applications of low dose imaging of a wide range of beam sensitive materials.

36 MATERIALS SCIENCE↗

Extending in situ X-ray Temperature Diagnostics to Internal Components

Time-resolved X-ray thermometry is an enabling technology for measuring temperature and phase change of components. However, current diagnostic methods are limited in their ability due to the invasive nature of probes or the requirement of coatings and optical access to the component. Our proposed developments overcome these challenges by utilizing X-rays to directly measure the objects temperature. Variable-Temperature X-ray Diffraction (VT-XRD) was performed over a wide range of temperatures and diffraction angles and was performed on several materials to analyze the patterns of the bulk materials for sensitivity. "High-speed" VT-XRD was then performed for a single material over a small range of diffraction angles to see how fast the experiments could be performed, whilst still maintaining peaks sufficiently large enough for analysis.

36 MATERIALS SCIENCE↗

Spatial dynamics of lithiation and lithium plating during high-rate operation of graphite electrodes

The principal inhibitor of fast charging lithium ion cells is the graphite negative electrode, where favorable conditions for lithium plating occur at high charge rates, causing accelerated degradation and safety concerns. The local response of graphite, both at the electrode and particle level, when exposed to fast charging conditions of around 6C is not well understood. Consequently, the conditions that lead to the onset of lithium plating, as well as the local dynamics of lithium plating and stripping, have also remained elusive. Here, we use high-speed (100 Hz) pencil-beam X-ray diffraction to repeatedly raster along the depth of a 101 μm thick graphite electrode in 3 μm steps during fast (up to 6C) charge and discharge conditions. Consecutive depth profiles from separator to current collector were each captured in 0.5 seconds, giving an unprecedented spatial and temporal description of the state of the electrode and graphite's staging dynamics during high rate conditions. The electrode is preferentially activated near the separator, and the non-uniformity increases with rate and is influenced by free-energy barriers between graphite's lithiation stages. The onset of lithium plating and stripping was quantified, occurring only within the first 15 μm from the separator. The presence of lithium plating changed the behavior of the underlying graphite, such as causing co-existence of LiC 6 and graphite in the fully discharged state. Finally, the staging behavior of graphite at different rates was quantified, revealing a high dependency on rate and drastic hysteresis between lithiation and delithiation.

25 ENERGY STORAGE↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Large-Angle Rocking Beam Electron Diffraction of Large Unit Cell Crystals Using Direct Electron Detector

We report a large-angle rocking beam electron diffraction (LARBED) technique for electron diffraction analysis. Diffraction patterns are recorded in a scanning transmission electron microscope (STEM) using a direct electron detector with large dynamical range and fast readout. We use a nanobeam for diffraction and perform the beam double rocking by synchronizing the detector with the STEM scan coils for the recording. Using this approach, large-angle convergent beam electron diffraction (LACBED) patterns of different reflections are obtained simultaneously. By using a nanobeam, instead of a focused beam, the LARBED technique can be applied to beam-sensitive crystals as well as crystals with large unit cells. Here, this paper describes the implementation of LARBED and evaluates the performance using silicon and gadolinium gallium garnet crystals as test samples. We demonstrate that our method provides an effective and robust way for recording LARBED patterns and paves the way for quantitative electron diffraction of large unit cell and beam-sensitive crystals.

4DSTEM↗

Polarization/Spatial Combining of Laser-Diode Pump Beams

A breadboard version of an optical beam combiner is depicted which make it possible to use the outputs of any or all of four multimode laser diodes to pump a non-planar ring oscillator (NPRO) laser. The output of each laser diode has a single-mode profile in the meridional plane containing an axis denoted the 'fast' axis and a narrower multimode profile in the orthogonal meridional plane, which contains an axis denoted the 'slow' axis and a narrower multimode profile in the orthogonal meridional plane, which contains an axis denoted the 'slow' axis. One of the purposes served by the beam-combining optics is to reduce the fast-axis numerical aperture (NA) of the laser-diode output to match the NA of the optical fiber. Along the slow axis, the unmodified laser-diode NA is already well matched to the fiber optic NA, so no further slow-axis beam shaping is needed. In this beam combiner, the laser-diode outputs are collimated by aspherical lenses, then half-wave plates and polarizing beam splitters are used to combine the four collimated beams into two beams. Spatial combination of the two beams and coupling into the optical fiber is effected by use of anamorphic prisms, mirrors, and a focusing lens. The anamorphic prisms are critical elements in the NA-matching scheme, in that they reduce the fast-axis beam width to 1/6 of its original values. Inasmuch as no slow-axis beam shaping is needed, the collimating and focusing lenses are matched for 1:1 iumaging. Because these lenses are well corrected for infinite conjugates the combiner offers diffraction-limited performance along both the fast and slow axes.

Gelsinger, Paul↗

Local nanoscale strain mapping of a metallic glass during in situ testing

The local elastic strains during tensile deformation in a CuZrAlAg metallic glass are obtained by fitting an elliptic shape function to the characteristic amorphous ring in electron diffraction patterns. Scanning nanobeam electron diffraction enables strain mapping with a resolution of a few nanometers. Here, a fast direct electron detector is used to acquire the diffraction patterns at a sufficient speed to map the local transient strain during continuous tensile loading in situ in the transmission electron microscope. The elastic strain in tensile direction was found to increase during loading. After catastrophic fracture, a residual elastic strain that relaxes over time was observed.

36 MATERIALS SCIENCE↗

In situ x-ray diffraction study of polyamorphism in H 2 O under isothermal compression and decompression

Amorphous-amorphous transformations in H 2 O have been studied under rapid isothermal compression and decompression in a diamond anvil cell together with in situ x-ray diffraction measurements using brilliant synchrotron radiation. The experimental pathways provide a density-driven approach for studying polyamorphic relations among low-, high-, and very high-density amorphs (LDA, HDA, VHDA) in a pressure range of 0-3.5 GPa at temperatures of 145-160 K. Our approach using rapid (de) compression allows for studying the polyamorphic transformations at higher temperatures than the conditions previously studied under slow (de) compression or isobaric annealing. Multiple compression-decompression cycles can be integrated with in situ x-ray measurements, thus facilitating the study of repeatability and reversibility of the polyamorphic transformations. Fast in situ x-ray diffraction measurements allow for obtaining detailed insight into the structural changes across polyamorphic transformations regarding the (dis) continuity, reversibility, and possible intermediate forms. As demonstrated at isothermal conditions of 145 K and 155 K, the polyamorphic transformations are characterized by a sharp and reversible LDA-VHDA transformation, with an HDA-like form (referred to as HDA' appearing as an intermediate state. The LDA-VHDA transformation is found to occur in two steps: a discontinuous transition between LDA and HDA' and a continuous change within HDA' involving structural reconfigurations and finally converging to VHDA. Published under license by AIP Publishing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Trends in the Analysis of Quasioptical Systems

The recent trend in microwave instruments is the use of multiple millimeter and submillimeter wavelength bands. These systems are typically analyzed by using physical optics, Gaussian beams or ray tracing techniques. Physical optics offers high accuracy at the expense of computation time. This trade-off becomes particularly apparent in the analysis of multiple reflector antennas, such as beam waveguide antennas, where physical optics is used to compute the current on each reflector from the current on the previous reflector. At the other end of the spectrum is ray tracing approaches that ignore diffraction effects entirely. These methods are fast but sacrifice the ability to predict some effects accurately. An intermediate approach is to use an appropriate set of expansion functions to model the field between the reflectors. If the set is chosen wisely only a few coefficients need to be determined from each reflector current. The field is then computed at the next reflector through the use of the expansion functions and their coefficients rather than by using the previous reflector current. For a beam waveguide system with no enclosing tubes an excellent set of expansion functions is the Gaussian beam mode set. In many cases a preliminary design which includes the effects on diffraction may be obtained by considering only the fundamental mode and a thin lens model for the reflectors. Higher-order modes are included to model the effects of the curved reflector, which include asymmetric distortion of the beam, cross polarization, and beam truncation. This paper describes a computer code implementing higher-order Gaussian beam scattering by multiple reflector systems. There are four essential steps in the algorithm. (1) Compute the current on the first reflector using physical optics using either a feed model or by an incident set of Gaussian beam modes. (2) Find the direction of propagation for the reflected Gaussian beam-set using ray tracing. (3) Determine the waist size and location for the output beam set by examining the amplitude and phase distribution of the current on the reflector. (4) Compute the amplitudes of the individual modes in the output mode set. These steps are then repeated for each addition reflector in the chain. In each of these cases the previous Gaussian beam set provides the input field for the current calculation. Details of the four steps discussed above will be discussed. Examples will compare results from the Gaussian beam approach to pure physical optics, illustrating both its merits and limitations. Hybrid approaches capable of eliminating some of the limitations will also be discussed.

Hoppe, D. J.↗

Autoindexing diffraction images with iMosflm

The principles of one-dimensional FFT-based autoindexing of diffraction images are described together with practical issues that may arise. A procedure for indexing multiple lattices as implemented in iMosflm is presented. An overview of autoindexing diffraction images based on one-@@dimensional fast Fourier transforms is presented. The implementation of the algorithm in the Mosflm/iMosflm program suite is described with a discussion of practical issues that may arise and ways of assessing the success or failure of the procedure. Recent developments allow indexing of images that show multiple lattices, and several examples demonstrate the success of this approach in real cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a multipurpose vacuum chamber for serial optical and diffraction experiments with free electron laser radiation

In this paper we present a development of a multipurpose vacuum chamber which primal function is to be used in pump/probe experiments with free electron laser (FEL) radiation. The chamber is constructed for serial diffraction and serial spectroscopy allowing a fast exchange of samples during the measurement process. For the fast exchange of samples, liquid jet systems are used. Both applications, utilizing soft x-ray FEL pulses as pump and optical laser pulses as probe and vice versa are documented. Experiments with solid samples as well as the liquid jet samples are presented. When working with liquid jets, a system of automatically refilled liquid traps for capturing liquids has been developed in order to ensure stable vacuum conditions. Differential pumping stages are placed in between the FEL beamline and the experimental chamber so that working pressure in the chamber can be up to four orders of magnitude higher than the pressure in the FEL beamline.

43 PARTICLE ACCELERATORS↗