Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Large Eddy Simulations of Turbulent and Buoyant Flows in Urban and Complex Terrain Areas Using the Aeolus Model

Fast and accurate predictions of the flow and transport of materials in urban and complex terrain areas are challenging because of the heterogeneity of buildings and land features of different shapes and sizes connected by canyons and channels, which results in complex patterns of turbulence that can enhance material concentrations in certain regions. To address this challenge, we have developed an efficient three-dimensional computational fluid dynamics (CFD) code called Aeolus that is based on first principles for predicting transport and dispersion of materials in complex terrain and urban areas. The model can be run in a very efficient Reynolds average Navier–Stokes (RANS) mode or a detailed large eddy simulation (LES) mode. The RANS version of Aeolus was previously validated against field data for tracer gas and radiological dispersal releases. As a part of this work, we have validated the Aeolus model in LES mode against two different sets of data: (1) turbulence quantities measured in complex terrain at Askervein Hill; and (2) wind and tracer data from the Joint Urban 2003 field campaign for urban topography. As a third set-up, we have applied Aeolus to simulate cloud rise dynamics for buoyant plumes from high-temperature explosions. For all three cases, Aeolus LES predictions compare well to observations and other models. These results indicate that Aeolus LES can be used to accurately simulate turbulent flow and transport for a wide range of applications and scales.

42 ENGINEERING↗

Optimal conditions for efficient flow-electrode capacitive deionization

One of the current barriers to achieving fast and stable performance for flow-electrode capacitive deionization (FCDI) is determining optimal operating parameters. To date, however, no consensus has been reached for universal conditions for FCDI. Through experimental and modeling approaches in this study, we systematically evaluated the influence of applied potential (V = 1.2–2.4 V) and electrolyte concentration (C0 = 0.05–0.5 M) on the FCDI and electrodialysis (ED) desalination processes. Evaluation indicators include the concentration decrease in the desalinated solution, salt removal rates, pH fluctuations, charge efficiency, and energy consumption. Results demonstrated that the dynamic curves of concentration decrease at 2.0 V nearly overlapped with the response at 1.6 V at certain electrolyte concentrations, while the salt removal rates at 0.2 M salt concentration were the best among all concentrations tested at a range of applied potential. Therefore, it was thus concluded that the optimum conditions for FCDI operation are 1.6 V applied potential and 0.2 M initial salt concentration, under which faradaic reactions are not being triggered, and concentration polarization does not significantly affect ion transfer. Furthermore, a comparative study between FCDI and ED indicated that ED has a different dependence on the electrolyte concentration and applied potential, in which the desalination can be linearly enhanced with increasing potential but greatly limited at high concentrations. Due to the presence of carbon particles in FCDI, the enhanced charge/ion transfer is probably the main reason for the different desalination performance of FCDI and ED. Overall, the optimal operating parameters obtained in this work could be used as basic test conditions for further development of new carbon-based materials for FCDI.

42 ENGINEERING↗

Hydraulic Conductivity Measurements, Utqiagvik (Barrow), Alaska, 2014

Six individual ice cores were collected from the Barrow Environmental Observatory in Barrow, Alaska, in May of 2013 as part of the Next Generation Ecosystem Experiment (NGEE). Each core was drilled at a different location to varying depths. After drilling, the cores were stored in coolers packed with dry ice and flown to Lawrence Berkeley National Laboratory (LBNL) in Berkeley, CA. 3-dimensional images of the cores were constructed using medical X-ray computed tomography (CT) scanner at 120kV. Hydraulic conductivity samples were extracted from these cores at LBNL Richmond Field Station in Richmond, CA, in February 2014 by cutting 5 to 8 inch segments using a chop saw. Samples were packed individually and stored at -20C freezing temperatures to minimize any changes in structure or loss of ice content prior to analysis. Hydraulic conductivity was determined through falling head tests using a permeameter [ELE International, Model #: K-770B] (Appendix A). Samples were placed in a latex membrane via a membrane stretcher while frozen. Use of a membrane stretcher made the membranes easier to secure and minimized contact with the sample. A clear polycarbonate sleeve, fabricated with a stainless steel ring at the bottom to keep the sleeve from floating, was placed around the sample inside the permeameter to minimize deformation during analysis. The permeameter was filled with water and 1.0 PSI of air was applied for confining pressure during sample defrost. Outflow valves were left open to allow for incremental thawing and samples were left to thaw for approximately 12 hours. After approximately 12 hours of thaw, initial falling head tests were performed. When the flow was significantly too fast or too slow, the analysis was stopped and the burette size was adjusted accordingly (i.e. a larger diameter burette was used for flows that were faster than desired or a smaller diameter burette was used for flows that were slower than desired). Two to four measurements were collected on each sample and collection stopped when the applied head load exceeded 25% change from the original load. Analyses were performed between 2 to 3 times for each sample. The final hydraulic conductivity calculations were computed using methodology of Das et al., 1985.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Results of the third Marine Ice Sheet Model Intercomparison Project (MISMIP+)

We present the result of the third Marine Ice Sheet Model Intercomparison Project, MISMIP+. MISMIP+ is intended to be a benchmark for ice-flow models which include fast sliding marine ice streams and floating ice shelves and in particular a treatment of viscous stress that is sufficient to model buttressing, where upstream ice flow is restrained by a downstream ice shelf. A set of idealized experiments first tests that models are able to maintain a steady state with the grounding line located on a retrograde slope due to buttressing and then explore scenarios where a reduction in that buttressing causes ice stream acceleration, thinning, and grounding line retreat. The majority of participating models passed the first test and then produced similar responses to the loss of buttressing. We find that the most important distinction between models in this particular type of simulation is in the treatment of sliding at the bed, with other distinctions – notably the difference between the simpler and more complete treatments of englacial stress but also the differences between numerical methods – taking a secondary role.

58 GEOSCIENCES↗

Coupled Thermo-Hydrological-Mechanical-Chemical Behavior of Anisotropic Granite for Geologic Disposal of High-Level Radioactive Waste: A Core-Scale Laboratory Investigation

The coupled thermo-hydrological-mechanical-chemical (THMC) behavior of rock within an Excavation Damaged Zone (EDZ) is critical for the safety and long-term performance of a geological repository for high-level radioactive wastes. While many laboratory experiments have been conducted to investigate EDZ rocks, the flow and deformation characteristics resulting from anisotropic rock textures and microcrack distribution under triaxial loading and elevated temperatures remain poorly understood. Particularly, cracks at various scales serve as fast paths for fluid flow and solute transport and present as focal points of mechanical weakness, which complicate the coupled THMC processes in anisotropic EDZ rocks and challenge modeling predictions. Here, in this study, a series of core-scale experiments was conducted on three granite samples under repository-relevant conditions. These rock samples were obtained from the Grimsel Underground Research Laboratory (URL), featured by anisotropic minerals (represented by bedding layers) and microcrack distributions and coarse cm-scale grain sizes. During the experiments, samples were subjected to an elevated temperature at 90 °C and different triaxial loading conditions either by radial (normal to bedding layers) or axial (parallel to bedding layers) compaction. Water was injected into the samples, and the rock permeability evolutions and effluent water chemistry were monitored closely. For intact samples, thermal expansion of minerals at 90 °C resulted in a large, 75% irreversible permeability reduction and rock strengthening under radial compaction, while thermal impact was limited to a 15% permeability reduction under axial compaction. In contrast, for a sample containing open cracks, the growth of fractures during the experiment resulted in an abrupt permeability increase and fast failure at 90 °C. The effluent water chemistry indicates much more considerable mineral dissolution from large shear sliding than that in rocks dominated by mechanical compaction. These results helped better understand the coupled THMC processes in anisotropic rocks containing cracks, evaluate the behaviors of EDZ rocks, and predict the long-term evolution of EDZ for the performance of the repositories.

Coupled THMC processes↗

Quasilinear critical gradient model for Alfven eigenmode driven energetic particle transport with intermittency

Abstract A simplified quasilinear critical gradient model (QLCGM) for Alfven eigenmode (AE) driven energetic particle (EP) transport is used to treat the intermittency (burstiness) of the transport. Here intermittency is defined as the ratio of the root mean square deviation from mean flow to the mean flow. The model posits that the intermittency results from the micro-turbulent noise induced in the thermal plasma damping rate for the AE. The model is embedded in a time-dependent EP density transport code to generate the transport-flow time traces from typical critical gradient and slowing down density profiles. The QLCGM appears to be in reasonable agreement with the level and characteristics of the intermittency observed in the DIII-D fast particle loss detector flow time traces: high kurtosis [ O (40)] of the burstiness with the intermittency O (1–2) increasing with the level of mean flow.

Physics↗

RockFlow: Fast Generation of Synthetic Source Rock Images Using Generative Flow Models

Image-based evaluation methods are a valuable tool for source rock characterization. The time and resources needed to obtain images has spurred development of machine-learning generative models to create synthetic images of pore structure and rock fabric from limited image data. While generative models have shown success, existing methods for generating 3D volumes from 2D training images are restricted to binary images and grayscale volume generation requires 3D training data. Shale characterization relies on 2D imaging techniques such as scanning electron microscopy (SEM), and grayscale values carry important information about porosity, kerogen content, and mineral composition of the shale. Here, we introduce RockFlow, a method based on generative flow models that creates grayscale volumes from 2D training data. We apply RockFlow to baseline binary micro-CT image volumes and compare performance to a previously proposed model. We also show the extension of our model to 2D grayscale data by generating grayscale image volumes from 2D SEM and dual modality nanoscale shale images. The results show that our method underestimates the porosity and surface area on the binary baseline datasets but is able to generate realistic grayscale image volumes for shales. With improved binary data preprocessing, we believe that our model is capable of generating synthetic porous media volumes for a very broad class of rocks from shale to carbonates to sandstone.

58 GEOSCIENCES↗

The curled wake model: a three-dimensional and extremely fast steady-state wake solver for wind plant flows

Abstract. Wind turbine wake models typically require approximations, such as wake superposition and deflection models, to accurately describe wake physics. However, capturing the phenomena of interest, such as the curled wake and interaction of multiple wakes, in wind power plant flows comes with an increased computational cost. To address this, we propose a new hybrid method that uses analytical solutions with an approximate form of the Reynolds-averaged Navier–Stokes equations to solve the time-averaged flow over a wind plant. We compare results from the solver to supervisory control and data acquisition data from the Lillgrund wind plant obtaining wake model predictions which are generally within 1 standard deviation of the mean power data. We perform simulations of flow over the Columbia River Gorge to demonstrate the capabilities of the model in complex terrain. We also apply the solver to a case with wake steering, which agreed well with large-eddy simulations. This new solver reduces the time – and therefore the related cost – it takes to simulate a steady-state wind plant flow (on the order of seconds using one core). Because the model is computationally efficient, it can also be used for different applications including wake steering for wind power plants and layout optimization.

17 WIND ENERGY↗

Demonstration of RANS models with wall functions in the spectral element code Nek5000

The spectral element based computational fluid dynamics (CFD) code Nek5000 has been traditionally used for high-fidelity applications, such as direct numerical simulation (DNS) and large eddy simulation (LES). These techniques require very fine numerical resolution to accurately capture turbulent fluctuations which can be prohibitively expensive for users without access to leadership class computing facilities. For broader application and adoption, significant effort has been invested to develop Reynolds-averaged Navier–Stokes (RANS) capabilities in Nek5000. Here, this work presents details of the implementation and demonstration of the standard wall functions for the κ–τ model in Nek5000. Results using the wall-modeled approach are compared to a wall-resolved approach for cases with negligible pressure gradient, viz., channel flow, pipe flow and flow in a reactor subchannel. Results show reasonably good agreement between the two approaches for friction factor and Nusselt number. Some expected differences are identified near the wall. These cases demonstrate the potential for significant computational savings by using much coarser meshes for the wall-modeled approach, with only minor differences between the predicted result. Additionally, several Reynolds numbers up to 1,000,000 are demonstrated for pipe flow and predicted friction factors and Nusselt numbers compared well to available correlations, with the worst below 10%. As the Reynolds number is increased, better agreement is observed between the correlations and the wall-modeled approach. In addition, flow in a molten salt fast reactor (MSFR) core is considered which features an adverse pressure gradient and flow separation. It showcases the inability of standard wall functions to accurately predict flows with adverse pressure gradients. The results, however, match reasonably well in trend in regions of the flow where the boundary layer is attached. Ongoing research is dedicated to include a pressure gradient correction to wall functions to improve the accuracy of flows with separation or reattachment and adverse or favorable pressure gradients.

42 ENGINEERING↗

Compatibility of Alumina-Forming Austenitic Steels in Static and Flowing Pb

Alumina-forming austenitic (AFA) steels were evaluated for the lead fast reactor application in static and flowing high-purity Pb. Two AFA composition ranges with different Ni, Mn, Al, Cr and Nb contents were targeted, and Zr foil was used in an attempt to getter O in some capsules. Based on two rounds of capsule testing at 500–800°C, two AFA compositions were selected for evaluation in flowing Pb with a peak temperature of 650°C in a thermal convection loop made of pre-oxidized FeCrAlMo tubing. After exposure for 1000 h, the mass losses for both AFA alloys were generally low, suggesting good compatibility under these conditions without preoxidation.

36 MATERIALS SCIENCE↗

Perturbed Ion Temperature and Toroidal Flow Profile Measurements in Rotating Neoclassical Tearing Mode Magnetic Islands

The perturbed ion temperature and toroidal flow were measured in rotating Neoclassical Tearing Modes (NTM) in a tokamak for the first time. These toroidally and radially resolved profiles were obtained by impurity ion spectroscopy in a 2,1 NTM in DIII-D. In agreement with drift-kinetic simulations, the electron temperature profile is flat, while the ion temperature gradient is restored across the magnetic island O-point in the presence of fast ions; the perturbed flow has minima in the O-points and maxima at the X-points. Furthermore, these measurements provide the first confirmation of the theoretically expected ion temperature and flow response to a magnetic island needed to predict the NTM on set threshold scaling for ITER and other future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

Stable and unstable supersonic stagnation of an axisymmetric rotating magnetized plasma

The Naval Research Laboratory ‘Mag Noh problem’, described in this paper, is a self-similar magnetized implosion flow, which contains a fast magnetohydrodynamic (MHD) outward propagating shock of constant velocity. We generalize the classic Noh ( OSTI Tech. Rep. 577058, 1983) problem to include azimuthal and axial magnetic fields as well as rotation. Our family of ideal MHD solutions is five parametric, each solution having its own self-similarity index, gas gamma, magnetization, the ratio of axial to the azimuthal field and rotation. While the classic Noh problem must have a supersonic implosion velocity to create a shock, our solutions have an interesting three-parametric special case with zero initial velocity in which magnetic tension, instead of implosion flow, creates the shock at $t=0+$ . Our self-similar solutions are indeed realized when we solve the initial value MHD problem with the finite volume MHD code Athena. We numerically investigated the stability of these solutions and found both stable and unstable regions in parameter space. Stable solutions can be used to test the accuracy of numerical codes. Unstable solutions have also been widely used to test how codes reproduce linear growth, transition to turbulence and the practically important effects of mixing. Now we offer a family of unstable solutions featuring all three elements relevant to magnetically driven implosions: convergent flow, magnetic field and a shock wave.

Mechanics↗

Experimental investigation of internal two-phase flow structures and dynamics of quasi-stable sheet cavitation by fast synchrotron x-ray imaging

The quasi-stable sheet cavitation produced in a small Venturi channel is investigated using a fast synchrotron X-ray imaging technique aided with conventional high speed photography. The use of X-rays instead of visible light solves cavitation opacity related issues, and X-ray phase contrast-based edge enhancement enables high-definition visualization of the internal two-phase morphology. The simultaneous acquisition of time-resolved velocity and void fraction fields through post-processing the recorded X-ray images reveals, for the first time, the complex diphasic flow structures inside the sheet cavity, which is essentially divided into 6 characteristic parts. Distinct from the current mainstream view, the globallysteady sheet cavitation is found to be characterized by a weak but constantly-existing re-entrant flow that can penetrate the entire cavity. The turbulent velocity fluctuations inside the sheet cavity are also investigated. The turbulence level in the reverse flow region is observed to be as low as in the outer main flow demonstrating the relatively steady status of the reentrant flow. Unlike the streamwise and cross-stream fluctuations, the shear stress appears to be weakly correlated with the velocity gradient. The collapse of vapor phase and the vaporization at the upstream cavity interface are found to be the primary causes of shear stress intensification.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2022 Final Report

The Thermal Hydraulic Experimental Test Article (THETA) is a METL vessel experiment designed for testing and validating sodium fast reactor components and phenomena. THETA has been scaled using a non-dimensional Richardson number approach to represent temperature distributions during nominal and loss of flow conditions in a sodium fast reactor (SFR), this analysis was detailed in the THETA FY19 report. The facility is being constructed with versatility in mind, allowing for the installation of various immersion heaters, heat pipes, and heat exchangers without significant facility modification. THETA was designed in collaboration with systems code experts to inform the geometry and sensor placement to acquire the highest value code validation data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗