Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Enhancing Mechanical Properties of a Medium-Entropy Alloy by Regulating Mo Addition

Some multi-principal element alloys (MPEAs), including equiatomic, single-phase CrCoNi and CrCoFeMnNi are now widely recognized for their remarkable combinations of pronounced hardening rates, high ductility, and exceptional fracture toughness at room and cryogenic temperatures. To push the limit of hardenability of the medium-entropy alloy, the strategies associated with local lattice distortion or stacking fault energy (SFE) reduction that promote complex heterogeneity and defect dynamics require further investigation. The purposes of this study are to (1) further enhance the mechanical properties of a typical medium-entropy NiCoCr with alloying Mo, and (2) understand the strengthening mechanism of a Mo-added medium-entropy alloys.

Hung, Chang-Yu↗

A Robust Communication-Free Protection Scheme for Islanded Microgrids with Relay Logic and Hardware-in-the-Loop Validation

This paper presents the Imbalance Square Factor (ISF) detection algorithm, an effective, computationally lightweight method for detecting faults in inverter-based microgrids. ISF provides a high magnitude at the time of the fault, which allows for fast detection and coordination between primary and backup relays. The imbalance squared factor, calculated using local voltage and currents, is used for fault detection and coordination among three relays. ISF is validated in hardware-in-the-loop (HIL) implementation inside commercial-grade relay logic (SEL-751). The HIL validation shows that ISF can coordinate primary, secondary, and tertiary relays in the 13-bus system in islanded operation.

Ferrari Maglia, Max [ORNL]↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seasonal Seismicity in the Lake Biwa Region of Central Japan Moderately Modulated by Lake Water Storage Changes

Seasonal seismicity in Japan has been observed and attributed to variations induced by hydrological loading, as well as atmospheric and pore-fluid pressure. We examine the seasonal variations of crustal (<15 km depth) and low magnitude (M < 4.5) earthquakes in central Japan near the Biwako-Seigan Fault Zone (BSFZ), and analyze their correlation with the annual hydrological cycle of nearby Lake Biwa, the largest freshwater lake in Japan. The 2002–2018 lake water storage is estimated using water-level gauge and satellite altimetry data. Regional surface mass loading from soil moisture and snow predicted by the Global Land Data Assimilation System is used to augment the lake mass variation. We compute the stress and stressing-rate changes induced by the surface mass loading from lake storage, snow, and soil moisture at seismogenic depth (10 km) along the BSFZ using a finite element model incorporating a 3D Earth structure. The results show that seasonal surface mass loading generates 1–5 kPa peak-to-peak Coulomb stress change and 2.5–15 kPa/year stressing-rate variations on the fault segments along the BSFZ. Two of the four fault segments present significant correlation between local seismicity rate and loading-derived stress and/or stressing rate changes. Among the hydrological load components, lake water, snow, and soil moisture exhibit different annual phases, and the lake water storage dominates the total annual stress changes. Our analysis indicates that seasonal surface hydrological loads, especially lake water variations, modulate the seismicity rate along the BSFZ in central Japan.

58 GEOSCIENCES↗

Comparison of Sequence Component-Based Fault Detection and Relay Coordination Algorithms in Inverter-Based Networks

Protection of inverter-based microgrids using sequence component-based relaying schemes is a promising solution. These methods offer several advantages, including lower computational requirements, compatibility with commercial relay systems, and cost-effectiveness compared to communication-based approaches. This article investigate the performance of various sequence component based schemes with the objective of identifying the algorithms that provide the best fault detection and relay coordination, solely relying on local voltages and current at relay terminals. Positive, negative and zero sequence impedance, admittance and power detection algorithms were tested on modified IEEE 13 bus test network for various shunt faults (LG, LL, LLG, LLL). Hardware-in-the-loop validation was achieved using the Typhoon real-time simulator, interfacing with a SEL 751 relay. This research demonstrates that while several algorithms are capable of detecting faults with sufficient accuracy, only a few are effective in achieving proper coordination. Validation results indicate that the negative sequence power approach provides the best performance in both fault detection and coordination.

Patel, Deepika [ORNL] (ORCID:0000000341099994)↗

Convolution Neural Network for Fault Identification in Distribution Feeder with High Penetration Solar PV

Identification and zonal classification of the faults is a decisive factor in the relay’s decision to trip or not. Different types of fault like three-phase, line-to-line-to-ground and single-line-to-ground can occur at various locations in the feeder. These faults are seen as the variation in the instantaneous values of three-phase voltages and currents, i.e., waveforms, that are measured at the relay location. The objective of this work is to develop a machine learning model that can identify a fault and classify it to various protection zones based on measured waveforms. In this work, a data-driven relay based on Convolutional Neural Network (CNN) is proposed for fault identification in distribution feeders with high penetration solar PV. The proposed CNN model takes local current and voltage waveforms as input and classify it into fault, no-fault or a capacitor switching. Further, the CNN also attempts to identify fault zones based on the images of waveforms. The overall testing accuracy of the trained model exceeds 95%.

Ramesh, Meghana↗

Creating superconductivity in WB 2 through pressure-induced metastable planar defects

High-pressure electrical resistivity measurements reveal that the mechanical deformation of ultra-hard WB 2 during compression induces superconductivity above 50 GPa with a maximum superconducting critical temperature, T c of 17 K at 91 GPa. Upon further compression up to 187 GPa, the T c gradually decreases. Theoretical calculations show that electron-phonon mediated superconductivity originates from the formation of metastable stacking faults and twin boundaries that exhibit a local structure resembling MgB 2 (hP3, space group 191, prototype AlB 2 ). Synchrotron x-ray diffraction measurements up to 145 GPa show that the ambient pressure hP12 structure (space group 194, prototype WB 2 ) continues to persist to this pressure, consistent with the formation of the planar defects above 50 GPa. The abrupt appearance of superconductivity under pressure does not coincide with a structural transition but instead with the formation and percolation of mechanically-induced stacking faults and twin boundaries. The results identify an alternate route for designing superconducting materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault-tolerant resource comparison of qudit and qubit encodings for diagonal quadratic operators

Finite local Hilbert-space truncations arise naturally in quantum simulations of lattice field theories and motivate qudit encodings, but their fault-tolerant advantage over qubit encodings remains unclear. We compare the non-Clifford cost of implementing quadratic diagonal evolutions, exemplified by 𝑈 = 𝑒$^{−𝑖⁢𝑡⁢𝜙^2_𝑥}$ in a uniform field-amplitude discretization of a real scalar field, using either one logical 𝑑-level qudit or 𝑛 𝑏 = ⌈log 2⁡ 𝑑⌉ logical qubits. We analyze two standard settings: product-formula simulation and linear combination of unitaries (LCU) per block encoding, taking the resource metric to be the number of non-Clifford gates after synthesis into a discrete logical gate set. Because tight synthesis bounds for general single-qudit rotations are not known, we express the qudit constructions in terms of embedded two-level SU⁡(2) rotations and derive explicit finite-𝑑 break-even conditions for their synthesis cost; these serve as compiler targets for when qudit encodings can outperform the qubit baseline. Within the constructive models studied here, product-formula implementations would require an exponentially stronger per-primitive synthesis advantage for qudits to win asymptotically, while in the LCU setting the qubit encoding is asymptotically cheaper in 𝑑. Nevertheless, the finite-𝑑 threshold analysis identifies low-dimensional regions in which qudits can yield meaningful constant-factor savings, particularly for LCU-based implementations. As a secondary analysis of the LCU construction, we use an idealized negligible-overhead qubit-qudit code-switching model to give an absolute 𝑇-count comparison and reinterpret the savings as an allowable per-switch overhead budget.

Godwood, Samuel [Univ. of Liverpool (United Kingdo↗

Physical characterization of fault rocks within the Opalinus Clay formation

Near-surface disposal of radioactive waste in shales is a promising option to safeguard the population and environment. However, natural faults intersecting these geological formations can potentially affect the long-term isolation of the repositories. This paper characterizes the physical properties and mineralogy of the internal fault core structure intersecting the Opalinus Clay formation, a host rock under investigation for nuclear waste storage at the Mont Terri Laboratory (Switzerland). We have performed porosity, density, microstructural and mineralogical measurements in different sections of the fault, including intact clays, scaly clays and fault gouge. Mercury intrusion porosimetry analysis reveal a gouge that has a pore network dominated by nanopores of less than 10 nm, yet a high-porosity (21%) and low grain density (2.62 g/cm 3 ) when compared to the intact rock (14.2%, and 2.69 g/cm 3 ). Thus, a more permeable internal fault core structure with respect to the surrounding rock is deduced. Further, we describe the OPA fault gouge as a discrete fault structure having the potential to act as a preferential, yet narrow, and localized channel for fluid-flow if compared to the surrounding rock. Since the fault gouge is limited to a millimetres-thick structure, we expect the barrier property of the geological formation is almost not affected.

58 GEOSCIENCES↗

Hierarchical memories: Simulating quantum LDPC codes with local gates

Constant-rate low-density parity-check (LDPC) codes are promising candidates for constructing efficient fault-tolerant quantum memories. However, if physical gates are subject to geometric-locality constraints, it becomes challenging to realize these codes. In this paper, we construct a new family of [[N,K,D]] codes, referred to as hierarchical codes, that encode a number of logical qubits K=Ω(N/log(N) 2 ). The N th element of this code family is obtained by concatenating a constant-rate quantum LDPC code with a surface code; nearest-neighbor gates in two dimensions are sufficient to implement the corresponding syndrome-extraction circuit and achieve a threshold. Below threshold the logical failure rate vanishes superpolynomially as a function of the distance D(N). We present a bilayer architecture for implementing the syndrome-extraction circuit, and estimate the logical failure rate for this architecture. Under conservative assumptions, we find that the hierarchical code outperforms the basic encoding where all logical qubits are encoded in the surface code.

Pattison, Christopher A. [California Institute of ↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Single-Particle Studies Reveal a Nanoscale Mechanism for Elastic, Bright, and Repeatable ZnS:Mn Mechanoluminescence in a Low-Pressure Regime

Mechanoluminescent materials, which emit light in response to elastic deformation, are demanded for use as in situ stress sensors. ZnS doped with Mn is known to exhibit one of the lowest reported thresholds for appearance of mechanoluminescence, with repeatable light emission under contact pressure <10 MPa. Here, the physical basis for such behavior remains as yet unclear. Here, reliable microscopic detection of mechanoluminescence of single ZnS:Mn microparticles, in combination with nanoscale structural characterization, provides evidence that the mechanoluminescent properties of these particles result from interplay between a non-centrosymmetric crystal lattice and its defects, viz., dislocations and stacking faults. Statistical analysis of the distributions of mechanoluminescence energy release trajectories reveals two distinct mechanisms of excitation: one attributable to a piezo-phototronic effect and the other due to dislocation motion. At pressures below 8.1 MPa, both mechanisms contribute to mechanoluminescent output, with a dominant contribution from the piezo-phototronic mechanism. In contrast, above 8.1 MPa, dislocation motion is the primary excitation source. For the piezo-phototronic mechanism, we propose a specific model that accounts for elastic ZnS:Mn mechanoluminescence under very low pressure. The charged interfaces in stacking faults lead to the presence of filled traps, which otherwise would be empty in the absence of the built-in electric field. Upon application of external stress, local enhancement of the piezoelectric field at the stacking faults’ interfaces facilitates release of the trapped carriers and subsequent luminescence. This field enhancement explains how <10 MPa pressure produces thousands of photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A continuum meshfree method for sandbox-style numerical modeling of accretionary and doubly vergent wedges

Here, in this study, we introduce and utilize GEOSPH, a Lagrangian particle-based continuum Smoothed Particle Hydrodynamics (SPH) code to simulate the deformation of geologic materials in sandbox-style experiments using an elastoplastic constitutive model. Due to the meshfree nature of SPH, our proposed framework is capable of handling the large deformations characteristic of sandbox-style experiments. SPH is also able to capture strain localization and discontinuities, allowing us to resolve faulting patterns emerging in the sandbox experiments. We successfully validate our SPH implementation against the benchmark experiments of Buiter and co-workers, and then apply SPH to understand the deformational processes occurring in doubly vergent orogens resultant from the S-point experimental setup and from finitely high wedge-like indenter backstops of different inclinations. We find that the topographic slope of the prowedge results from the competing processes of vertical uplift due to the indenter and forward thrusting, while the topographic slope of the retrowedge is a product of repeated shallow slope failure. Our findings show that SPH is a promising numerical method which should be added to the current palette of computational tools used by structural geologists for solving problems relating to tectonics and crustal deformation.

58 GEOSCIENCES↗

Grid-Forming Inverters for Stability Improvements in Bulk Power Systems with High Inverter-Based Resources Penetration

The grid-forming inverter (GFM) has been considered recently as a means to enhance grid stability in areas with Inverter-based Resources (IBRs) concentration. This paper assesses the potential improvements the GFM can bring to Bulk-power Systems (BPS) through two distinct studies. The first study was conducted on West Texas in ERCOT with presence of more than 35GW of IBRs, the Grid-Following (GFL) batteries were replaced with GFM batteries. The results demonstrate that the GFM significantly improved the voltage profile and active power injection during and after a fault. The second study focused on a local area within ERCOT grid. In this case, a battery operating as GFL within the local study area was replaced with a GFM battery. The findings clearly illustrate that GFM can strengthen the area and allow a higher IBRs power generation and a higher power export from the local study area.

Quedan, Amro↗

Practical Implementation of GPU-based Computing at the Grid Edge for Resilience Scenarios

This paper presents a practical implementation of GPU-accelerated computing at the grid edge to enhance power system resilience through next-generation smart meters. Advanced Metering Infrastructure (AMI) systems rely predominantly on centralized processing architectures, which limit real-time response capabilities during grid disturbances. This work proposes the integration of GPU-enabled computational platforms directly within smart meter to enable local execution support for power system analytics, fault detection algorithms, and optimization routines. The proposed framework uses the Julia programming language to leverage highperformance parallel computing capabilities while maintaining code portability and development efficiency. We use two experimental scenarios to benchmark the computational feasibility of this approach: sparse linear system solutions representative of power flow analyses, and multi-stage production cost simulations incorporating unit commitment and economic dispatch operations. Results demonstrate that computationally intensive power system algorithms, such as those supporting resilience scenario calculations, can be effectively executed at the distribution edge using commercially available embedded GPU hardware. Keywords—GPU acceleration, edge computing, smart meters, grid resilience, AMI, resilience.

De Souza, Reubun [School of Electrical Engineering↗

Ensemble models for circuit topology estimation, fault detection and classification in distribution systems

This paper presents a methodology for simultaneous fault detection, classification, and topology estimation for adaptive protection of distribution systems. The methodology estimates the probability of the occurrence of each one of these events by using a hybrid structure that combines three sub-systems, a convolutional neural network for topology estimation, a fault detection based on predictive residual analysis, and a standard support vector machine with probabilistic output for fault classification. The input to all these sub-systems is the local voltage and current measurements. A convolutional neural network uses these local measurements in the form of sequential data to extract features and estimate the topology conditions. The fault detector is constructed with a Bayesian stage (a multitask Gaussian process) that computes a predictive distribution (assumed to be Gaussian) of the residuals using the input. Since the distribution is known, these residuals can be transformed into a Standard distribution, whose values are then introduced into a one-class support vector machine. The structure allows using a one-class support vector machine without parameter cross-validation, so the fault detector is fully unsupervised. Finally, a support vector machine uses the input to perform the classification of the fault types. All three sub-systems can work in a parallel setup for both performance and computation efficiency. In conclusion, we test all three sub-systems included in the structure on a modified IEEE123 bus system, and we compare and evaluate the results with standard approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗