Search NASA⌕ Search

SEARCH · Search NASA

Results for “faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Understanding Mixed Precision GEMM with MPGemmFI: Insights into Fault Resilience

Emerging deep learning workloads urgently need fast general matrix multiplication (GEMM). Thus, one of the critical features of machine-learning-specific accelerators such as NVIDIA Tensor Cores, AMD Matrix Cores, and Google TPUs is the support of mixed-precision enabled GEMM. For DNN models, lower-precision FP data formats and computation offer acceptable correctness but significant performance, area, and memory footprint improvement. While promising, the mixed-precision computation on error resilience remains unexplored. To this end, we develop a fault injection framework that systematically injects fault into the mixed-precision computation results. We investigate how the faults affect the accuracy of machine learning applications. Based on the characteristics of error resilience, we offer lightweight error detection and correction solutions that significantly improve the overall model accuracy by 75% if the models experience hardware faults. The solutions can be efficiently integrated into the accelerator's pipelines.

Fang, Bo↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

A New High-Impedance-Fault Detection Method to Prevent Power-Line-Induced Wildfires

High Impedance Faults (HIFs) occur when energized power lines come into contact with high impedance ground surfaces, such as tree branches and grassland. HIFs have the potential to cause arcing, leading to vegetation ignition and the initiation of wildfires. The challenge in detecting HIFs comes from the high impedance of the partially conductive materials in contact with the power lines. They create a fault current of low magnitude and traditional protective devices struggle to detect such faults. This paper proposes a novel HIF detection algorithm based upon the analyzed arcing signatures associated with HIFs. The algorithm is evaluated using the Australian Public Bushfire Safety Program (PBSP) dataset. For comparative analysis, a state-of-the-art commercial HIF detection product is also evaluated using the same dataset. The proposed algorithm demonstrates higher detection accuracy over the commercial products with fewer false flags and undetected faults.

grasslands↗

Comparison of Sequence Component-Based Fault Detection and Relay Coordination Algorithms in Inverter-Based Networks

Protection of inverter-based microgrids using sequence component-based relaying schemes is a promising solution. These methods offer several advantages, including lower computational requirements, compatibility with commercial relay systems, and cost-effectiveness compared to communication-based approaches. This article investigate the performance of various sequence component based schemes with the objective of identifying the algorithms that provide the best fault detection and relay coordination, solely relying on local voltages and current at relay terminals. Positive, negative and zero sequence impedance, admittance and power detection algorithms were tested on modified IEEE 13 bus test network for various shunt faults (LG, LL, LLG, LLL). Hardware-in-the-loop validation was achieved using the Typhoon real-time simulator, interfacing with a SEL 751 relay. This research demonstrates that while several algorithms are capable of detecting faults with sufficient accuracy, only a few are effective in achieving proper coordination. Validation results indicate that the negative sequence power approach provides the best performance in both fault detection and coordination.

Patel, Deepika [ORNL] (ORCID:0000000341099994)↗

Multivariate Time Series Intermittent Fault Detectionin Controller Area Network CAN

Fault detection in Controller Area Network (CAN) systems is crucial for ensuring the reliability and safety of automotive and industrial applications. This study investigates and compares the effectiveness of time series classification models for supervised fault detection in CAN data. This repository contains the code and data for our benchmarking experiment aimed at detecting intermittent faults in automotive Controller Area Network (CAN) data. The goal of this project is to compare various machine learning (ML) and deep learning (DL) models using different Time Series Cross-Validation (TSCV) techniques to evaluate their effectiveness in a streaming environment for fault detection.

Hespeler, Steven [Oak Ridge National Laboratory (O↗

Temporal and spatial characterization of a thermogenic, fault-controlled gas hydrate system, Woolsey Mound, Gulf of Mexico

Woolsey Mound, located at Mississippi Canyon Lease Block 118 (MC118), is the site of the Gulf of Mexico hydrate research consortium’s seafloor observatory, where gas hydrates outcrop at the seafloor. The presence of gas hydrates in the mound is confirmed directly by coring and indirectly by 3D seismic reflection data. Craters, pockmarks, chemosynthetic communities, and authigenic carbonates populate the seafloor at Woolsey Mound. Each crater is characterized by a network of shallow crestal faults that connect the hydrate mound to the underlying allochthonous salt body. We characterize the temporal and spatial evolution of gas hydrates at Woolsey Mound under natural perturbations using four collocated 3D seismic reflection data sets that span over 14 years. Data acquisition differences embedded in the data sets arising from variation in geometry, sample rate, and phase are minimized using the “cross-equalization” method. Our results indicate that hydrate formation and dissociation vary temporally and spatially in close connection to the shallow crestal faults. Evidence of gas hydrate dissociation is observed over a period of three years (2000–2003), where major dissociation occurred along the southern portion of the crestal fault in the southeast crater. The dissociation is less prominent in the southwest crater. Evidence of methane venting is observed between 2000 and 2010, which is mostly concentrated in the southeast crater. The residual amplitude anomalies observed between 2000 and 2014 in the mound are mostly positive, implying that the methane venting had increased significantly. The positive anomalies are correlated with the methane seepage recorded in 2011. Our results indicate the evolution of a fault-controlled gas hydrate system in the northern Gulf of Mexico, which would aid in assessing its impact on the seafloor.

Geochemistry & Geophysics↗

Assessing the Impact of Variable Air Volume Box Damper Stuck Faults Using a Building Automation System and Building Energy Simulation Model

The study examines the impact of variable air volume (VAV) damper stuck faults on the system operation, building indoor conditions, and reheating energy consumption. This study includes both experimental and simulation studies for five test scenarios, including a fault-free scenario. We implemented VAV damper stuck fault through the building automation system (BAS). Results show that a damper stuck in a high opening position (60% damper opening) results in supplying an excessive amount of cold air from the rooftop unit (RTU) to the conditioned zone, increasing reheating energy consumption. The results of this research can serve as a foundational resource for developing fault detection algorithms.

Jung, Sungkyun↗

Simulations of the fault current limiting operation of a long-length REBCO CORC ® superconducting cable cooled by helium gas

Conductor-on-round-core (CORC®) cables composed of rare-earth-barium-copper-oxide high-temperature superconducting (HTS) tapes are of great interest for power transmission applications due to their many advantages such as high power density, light weight, and low loss. Closed circulation loops of cryogenic helium gas can be used to cool HTS cables down to low temperatures to significantly improve their current-carrying capacity. Coupled circuit-electromagnetic-thermal finite element simulations implemented in the COMSOL Multiphysics package were developed, validated, and then used for simulating the fault current limiting (FCL) performance and the cooling processes of an 8-layer CORC® cable cooled with a flow of cryogenic helium gas. In the simulations, the temperature dependence of the electrical and thermal properties of all component materials is implemented for improved accuracy. To overcome computational challenges caused by the considerable difference in geometrical scales (i.e. few-µm-thick HTS layers versus 10 m-long HTS cable), the model is divided into two separate simulations. The first simulation is performed on the transverse cross-section of the cable to calculate the electric field, heating power and temperature rise in each component of a CORC® cable during FCL operation. The heating power calculated in the first simulation is transferred to the second model to simulate the cooling of a 10 m-long cable after the fault is cleared. The effect of the helium gas flow rate on the cooling process is also investigated to develop strategic approaches for optimizing cooling systems for HTS cables with FCL capability. The simulations indicated that a 40 ms fault with a voltage drop of 20 V m −1 along the cable can result in a temperature increase from 60 K to about 165 K inside the cable, and it takes about 500 s to cool the cable back to nearly 60 K with a flow of cold helium gas at a rate of 5 g s −1 .

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

MRCI Subtask 2.2: Precambrian Basement Structure, Faulting, and Stress Final Technical Summary Report

Subtask 2.2 was largely focused on compiling information about the Precambrian basement rock that underlies the MRCI region. Understanding the nature and extent of the basement rock is important in order to mitigate certain risks associated with CO2 injection. For example, this information will provide a resource for defining areas where a storage reservoir is in direct contact with the Precambrian or indirectly via a fault. Also, an understanding of the stress field in addition to fault orientations will help determine which faults may be subject to reactivation under increased pore pressures.

Battelle,CCS,CCUS,Carbon storage,MRCI,Midwest Regi↗

Eucalyptus – An Analysis Suite for Fault Trees with Uncertainty Quantification

Eucalyptus is a novel code developed at Lawrence Livermore National Laboratory to incorporate uncertainty quantification into Fault Tree Analysis (FTA). This tool addresses the challenge of imperfect knowledge in “grey-box” systems by allowing analysts to incorporate and propagate uncertainty from component-level assessments to system-level effects. Eucalyptus facilitates a consistent evaluation of the impact of subject matter expert judgment and knowledge gaps on overall system response by Monte Carlo generation of possible system fault trees, sampling probabilities of the existence of subsystems and components. Here, the code supports the specification of fault trees through text and allows export to various formats, including auto-generated images, easing analysis and reducing errors. It has undergone extensive verification testing, demonstrating its reliability and readiness for deployment, and leverages on-node parallelism for rapid analysis. Example analyses are shown that include the identification of system failure paths and quantification of the value of further information about system components.

Fault Tree Analysis↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

In situ studies on heavy ion irradiation and partial oxidation induced stacking faults and nanograins in tungsten nanolaminates

Understanding the microstructural evolution of tungsten (W) under extreme irradiation environments is critical for its application as a plasma-facing material in future fusion reactors. Heavy ion irradiation study offers expedited damage accumulation and thus allows irradiation tolerance property prediction in a short period of time. In this study we explore in situ Kr ion irradiation of W nanolaminates at 800 °C and uncover a complex interplay of irradiation-induced transformations, including the emergence of stacking faults, nanograin formation, and generation of thickened grain boundaries defined as GB regions with the thickness of up to 15 nm. High-resolution transmission electron microscopy studies reveal the formation of extended planar faults and a metastable hexagonal close-packed (hcp) phase within the body-centered cubic (bcc) matrix. These structural transitions are facilitated by irradiation-induced shear. They are further stabilized by the presence of oxygen, which promotes stacking fault formation and vacancy trapping. Elevated temperatures enhance defect mobility, enabling dynamic recrystallization into ultrafine grains and the thickening of GBs due to defect absorption and impurity segregation. These findings unravel non-equilibrium phase transformation pathways in heavy ion irradiated W and highlight the critical role of impurity-mediated defect dynamics in governing its radiation tolerance properties.

Wazeer, Adil [Purdue University]↗

In Situ Velocity‐Strain Sensitivity Near the San Jacinto Fault Zone Analyzed Through Train Tremors

Abstract We utilize train tremors as P‐wave seismic sources to investigate velocity‐strain sensitivity near the San Jacinto Fault Zone. A dense nodal array deployed at the Piñon Flat Observatory is used to detect and identify repeating train energy emitted from a railway in the Coachella valley. We construct P‐wave correlation functions across the fault zone and estimate the spatially averaged dt / t versus strain sensitivity to be 6.25 × 10 4 . Through numerical simulations, we explore how the sensitivity decays exponentially with depth. The optimal solution reveals a subsurface sensitivity of 1.2 × 10 5 and a depth decay rate of 0.05 km −1 . This sensitivity aligns with previous findings but is toward the higher end, likely due to the fractured fault‐zone rocks. The depth decay rate, previously unreported, is notably smaller than assumed in empirical models. This raises the necessity of further investigations of this parameter, which is crucial to study stress and velocity variations at seismogenic depth.

Geology↗

Hayward Fault Creep From Coda Wave Interferometry

Understanding creep is essential for assessing seismic hazards along the creeping Hayward Fault, which threatens the San Francisco area. Current 1-D monitoring methods, like creepmeters and theodolites, provide limited measurements with low spatial resolution. InSAR offers higher 2-D spatial sampling but lower temporal resolution. We introduce a novel method using coda wave interferometry (CWI) to monitor creep in 2-D with high resolution. By calculating changes in ambient seismic noise travel times, we relate these measurements to creep offsets, bridging the gap between existing methods. Applied to seismic data from 2021 around the Hayward Fault, our CWI-derived offsets aligned with creepmeter measurements, revealing continuous and episodic creep. A 2-D regionalization identified a spatial boundary between these regimes, corroborating previous findings. This approach could enhance seismic monitoring and improve understanding of fault mechanics and earthquake risks.

Luckie, Thomas William [Sandia National Laboratori↗

Fault-tolerant optical interconnects for neutral-atom arrays

We analyze the use of photonic links to enable large-scale fault-tolerant connectivity of locally error-corrected modules based on neutral atom arrays. Our approach makes use of recent theoretical results showing the robustness of surface codes to boundary noise and combines recent experimental advances in atom-array quantum computing with logical qubits with optical quantum networking techniques. We find the conditions for fault tolerance can be achieved with local two-qubit Rydberg gate and nonlocal Bell-pair errors below 1% and 10%, respectively, without requiring distillation or space-time overheads. Realizing the interconnects with a lens, a single optical cavity, or an array of cavities enables—with sufficient multiplexing—a Bell-pair generation rate in the 1–50 MHz range. When directly interfacing logical qubits, this rate translates to error-correction cycles in the 25–2000 kHz range, satisfying all requirements for fault tolerance and in the upper range fast enough for 100 kHz logical clock cycles. Published by the American Physical Society 2025

Sinclair, Josiah (ORCID:0000000215238295)↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗