FEMP Focus - Summer 2008
Features information about guidance for laboratories, Labs21, Philadelphia custom house, metering, data centers, ESPC, renewable energy projects, and more for federal agencies.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Features information about guidance for laboratories, Labs21, Philadelphia custom house, metering, data centers, ESPC, renewable energy projects, and more for federal agencies.
Features information about guidance for laboratories, Labs21, Philadelphia custom house, metering, data centers, ESPC, renewable energy projects, and more for federal agencies.
Comprehensive Federal fleet management guide offered as a companion to Executive Order 13514 Section 12 guidance.
Case study overview of integrated solar hot water/photovoltaic systems at the U.S. Marine Corps Camp Pendleton training pools.
December 2009 update report offered by the Interagency Sustainability Working Group (ISWG). This report is updated bi-annually.
Executive Order 13514, Section 12, guidance document for Federal fleet management.
ESPC Success Story on water conservation and green energy at Dyess Air Foce Base at Dyess, Texas.
ESPC success story on environmental stewardship and cost savings at the U.S. Naval Station at Guantanamo Bay, Cuba.
Features information about renewable energy guidance, success stories, upcoming ESPC training and events, 2008 awards criteria, and more for federal agencies.
ESPC Success Story on how a comprehensive effort cuts energy use by 44% at Marine Corps Base Camp Pendleton in Camp Pendleton, California.
An ESPC is a working relationship between a Federal agency and an energy service company (ESCO). The ESCO conducts a comprehensive energy audit for the Federal facility and identifies improvements to save energy. In consultation with the Federal agency, the ESCO designs and constructs a project that meets the agency’s needs and arranges the necessary funding. The ESCO guarantees the improvements will generate energy cost savings sufficient to pay for the project over the term of the contract. After the contract ends, all additional cost savings accrue to the agency.
Fact sheet describes the Federal Energy Management Program’s Distributed Energy Program, which facilitates the implementation of cost-effective, on-site renewable energy and energy storage technologies for federal agencies.
Describes agency initiative to educate managers about operational technology cybersecurity concepts.
Comprehensive Federal fleet management guide offered as a companion to Executive Order 13514 Section 12 guidance.
This documents reports on a request for technical assistance from Fort Devens to analyze procurement of energy from nearby renewable generating resources.
This document describes technical assistance provided by PNNL to further develop a smart grid technologies concept to provide a basis for policies and plans for the US Army. The effort was to analyze the potential to utilize emerging smart grid technologies along with indigenous renewable and other resources to meet the emergency and other power needs of Department of Defense facilities in Colorado and Wyoming.
The potential to increase utilization of renewable energy sources among military facilities in Alaska through coordinated development and operation is the premise of this task. The US Army Pacific Command requested assistance from PNNL to help develop a more complete understanding of the context for wheeling power within Alaska, including legal and regulatory barriers that may prohibit the DOD facilities from wheeling power among various locations to optimize the development and use of renewable resources.
Document describes an onsite workshop and building retuning training conducted in Guam in August 2010. Document reports on issues identified during an audit of several buildings and recommendations to save energy throughout the site. During the workshop, it became apparent that as site personnel maintain the facilities at Guam, the following retuning efforts and strategies should be prioritized: (1) Controlling the mechanical systems operational hours and zone temperature set points appeared to present the best opportunities for savings; (2) Zone temperature set points in some buildings are excessively low, especially at night, when the zone temperatures are so cold that they approached the dewpoint; and (3) Manually-set outside air dampers are providing excessive outside air, especially for spaces that are unoccupied. Two of the larger schools, one on the Naval Base and one on Anderson AFB, are in need of a significant recommissioning effort. These facilities are relatively new, with direct digital controls (DDC) but are significantly out of balance. The pressure in one school is extremely negative, which is pulling humid air through the facility each time a door is opened. The draft can be felt several feet down the halls. The pressure in the other school is extremely positive relative to the outside, and you can stand 20-feet outside and still feel cool drafts of air exiting the building. It is recommended that humidity sensors be installed in all new projects and retrofitted into exist facilities. In this humid climate, control of humidity is very important. There are significant periods of time when the mechanical systems in many buildings can be unloaded and dehumidification is not required. The use of CO{sub 2} sensors should also be considered in representative areas. CO{sub 2} sensors determine whether spaces are occupied so that fresh air is only brought into the space when needed. By reducing the amount of outside air brought into the space, the humidity load is also substantially reduced. CO{sub 2} and humidity sensors, combined with outside air sensors, can be used to predict whether conditions are amenable to mold growth and to automatically adjust systems to help prevent mold without using extra energy. The goal of this training is to give the building operators the knowledge needed to make positive changes in the operation of building systems. As class participants apply this knowledge, building systems will run more efficiently, occupant comfort should improve, while saving energy and reducing greenhouse gas emissions.