Search NASA⌕ Search

SEARCH · Search NASA

Results for “field evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Field Evaluation of Anti-Biofouling Compounds on Optical Instrumentation

Biofouling has been a serious question in the stability of optical measurements in the ocean, particularly in moored and drifting buoy applications. Many investigators coat optical surfaces with various compounds to reduce the amount of fouling; to our knowledge, however, there are no objective, in-situ comparative testing of these compounds to evaluate their effectiveness with respect to optical stability relative to untreated controls. We have tested a wide range of compounds at in-situ locations in Halifax Harbour and in the Adriatic Sea on passive optical sensors. Compounds tested include a variety of TBT formulations, antifungal agents, and low-friction silicone-based compounds; time-scales of up to four months were evaluated. The results of these experiments are discussed.

McLean, Scott↗

UWB EMI To Aircraft Radios: Field Evaluation on Operational Commercial Transport Airplanes

Ultrawideband (UWB) transmitters may soon be integrated into a wide variety of portable electronic devices (PEDs) that passengers routinely carry on board commercial airplanes. Airlines and the FAA will have difficulty controlling passenger use of UWB transmitters during flights with current airline policies and existing wireless product standards. The aeronautical community is concerned as to whether evolving FCC UWB rules are adequate to protect legacy and emerging aeronautical radio systems from electromagnetic interference (EMI) from emerging UWB products. To address these concerns, the NASA Office of Space Communications and Chief Spectrum Managers assembled a multidisciplinary team from NASA LaRC, NASA JPL, NASA ARC, FAA, United Airlines, Sky West Airlines, and Eagles Wings Inc. to carry out a comprehensive series of tests aimed at determining the nature and extent of any EMI to aeronautical communication and navigation systems from UWB devices meeting FCCapproved and proposed levels for unlicensed handheld transmitters.

Oria, A. J.↗

Field Evaluation in Four NEEMO Divers of a Prototype In-suit Doppler Ultrasound Bubble Detector

It is desirable to know if astronauts produce venous gas emboli (VGE) as a result of their exposure to 4.3 psia during space walks. The current prototype in-suit Doppler (ISD) ultrasound bubble detector provides an objective assessment of decompression stress by monitoring for VGE. The NOAA Aquarius habitat and NASA Extreme Environment Mission Operations (NEEMO) series of dives provided an opportunity to assess the ability of the prototype ISDs to record venous blood flow and possibly detect VGE in the pulmonary artery. From July 16 to 29,2003, four aquanauts (two males and two females) donned the ISD for a 4 hr automated recording session, following excursion dives (up to 6hrs and 29 MSW below storage depth) from air saturation at 17 MSW. Doppler recordings for 32 excursion dives were collected. The recordings consisted of approximately 150 digital wave files. Each wave file contained 24 sec of recording for each min. A 1 - 4 Doppler Quality Score (DQS) was assigned to each wave file in 17 of the 32 records evaluated to date. A DQS of 1 indicates a poor flow signal and a score of 4 indicates an optimum signal. Only 23% of all wave files had DQSs considered adequate to detect low grade VGE (Spencer I-II). The distribution of DQS in 2,356 wave files is as follows: DQS 1-56%, DQS 2-21%, DQS 3-18% and DQS 4-5%. Six of the 17 records had false positive VGE (Spencer I-IV) detected in one or more wave files per dive record. The false positive VGE recordings are attributable to air entrainment associated with drinking (verified by control tests), and this observation is important as astronauts drink water during space walks. The current ISD design provides quality recordings only over a narrow range of chest anatomy.

Acock, K. E.↗

Field Evaluation of Portable Soil Water Content Sensors in a Sandy Loam

Ground observations are critical in the validation of soil water content (SWC) estimates from both satellites and land surface models. Portable SWC sensors provide useful information to determine the amount of SWC in the topsoil layer for various applications; however, these probes are not accurate without site‐specific correction. In the present study, we examined and compared six different types of portable electromagnetic (EM) SWC sensors, including multiple sensors made by the same manufacturers, for a total of 16 EM‐based SWC probes equipped with portable data loggers. All SWC probes met the target accuracy after onsite correction—the RMSD was <0.025 m(exp 3) m(exp -3). Using the two‐sample t-tests, we observed that SWC data obtained from similar electrode lengths and from different manufacturers showed similar distributions over time with the same mean. Furthermore, using the maximize R method to combine SWC data from two different types of sensors increased the accuracy of the results. When datasets from two different types of sensors were combined, the Pearson's correlation coefficient (R value) and RMSD values were improved. The average R value improved from .930 to .945, and the RMSD decreased from 0.036 m(exp 3) m(exp -3) to 0.018 m(exp 3) m(exp −3). These results indicate that, along with site‐specific correction, synergetic use of multiple manufacturers’ EM‐based SWC probes can improve the R value and reduce systematic bias.

soil moisture data↗

Medium- and Heavy-Duty Vehicle Field Evaluations

This presentation provides information about NREL's real-world evaluations of commercial vehicle technologies, which compare the performance of advanced medium- and heavy-duty fleet vehicles to conventional vehicles. NREL conducts these customized evaluations in partnership with commercial and government fleets across the nation. Current fleet and industry partners include UPS, Workhorse, Parker Hannifin, Proterra, Foothill Transit, Long Beach Transit, BYD, Odyne, Duke Energy, Miami-Dade, TransPower, Eaton, Cummins, Bosch, and Clean Cities/National Clean Fleet Partnership. The presentation focuses on two particular vehicle evaluation projects -- hydraulic hybrid refuse haulers operated by Miami-Dade and electric transit buses operated by Foothill Transit.

33 ADVANCED PROPULSION SYSTEMS↗

Improved Field Evaluation of Reference Cell Using Spectral Measurements: Preprint

Spectral irradiance measurements as opposed to modeled spectral values are used to evaluate the effects of changing spectral distributions on the output of reference solar cells. Comparisons are made on a one-axis tracking surface to a Class A pyranometer. The ratio of the reference cells to reference pyranometers exhibit a bias over the day. Spectral and temperature modeling reproduce most but not all changes in the ratio over the day. Sources for this difference in modeling and performance of the reference cells are examined.

14 SOLAR ENERGY↗

Field Evaluation of a High-Efficiency RTU

This case study describes the development and demonstration of a specification for high-performance rooftop air conditioning units with capacity ranges between 10 and 20 tons. It is focused on Daikin’s Rebel RTU, which was recognized by DOE as the first to meet its RTU Challenge specifications. The demonstration took place at two Publix grocery stores located in New Smyrna Beach and Port Orange, Florida.

rooftop unit, RTU, specification, high performance↗

Evaluation and Field Assessment of Bifacial Photovoltaic Module Power Rating Methodologies

1-sun power ratings for bifacial modules are currently undefined. This is partly because there is no standard definition of rear irradiance given 1000 Wm-2 on the front. Using field measurements and simulations, we evaluate multiple deployment scenarios for bifacial modules and provide details on the amount of irradiance that could be expected. A simplified case that represents a single module deployed under conditions consistent with existing 1-sun irradiance standards leads to a bifacial reference condition of 1000 Wm-2 Gfront and 130-140 Wm-2 Grear. For fielded systems of bifacial modules, Grear magnitude and spatial uniformity will be affected by self-shade from adjacent modules, varied ground cover, and ground-clearance height. A standard measurement procedure for bifacial modules is also currently undefined. A proposed international standard is under development, which provides the motivation for this work. Here, we compare outdoor field measurements of bifacial modules with irradiance on both sides with proposed indoor test methods where irradiance is only applied to one side at a time. The indoor method has multiple advantages, including controlled and repeatable irradiance and thermal environment, along with allowing the use of conventional single-sided flash test equipment. The comparison results are promising, showing that the indoor and outdoor methods agree within 1%-2% for multiple rear-irradiance conditions and bifacial module types.

14 SOLAR ENERGY↗

Evaluation of magnetic field error in ExtendedEBIS

The upgrade of the EBIS, called ExtendedEBIS, is now in progress in Brookhaven National Laboratory. Two 5T-superconducting solenoids have been placed in series with 200 mm distance from each other for higher trap capacity and production of polarized 3He ions. Since the two superconducting solenoids are used, the field error is expected to be larger. In this research, the field error is estimated based on simulation. It was found that the magnetic field line can be 17 mm off from the center axis at the entrance of the collector, and this offset can be adjusted by three types of correction coils. Additionally, mismatch of the spin direction of polarized 3He due to the misalignment was estimated to be small.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Development of a Visual Inspection Checklist for Evaluation of Fielded PV Module Condition (Presentation)

A visual inspection checklist for the evaluation of fielded photovoltaic (PV) modules has been developed to facilitate collection of data describing the field performance of PV modules. The proposed inspection checklist consists of 14 sections, each documenting the appearance or properties of a part of the module. This tool has been evaluated through the inspection of over 60 PV modules producedby more than 20 manufacturers and fielded at two different sites for varying periods of time. Aggregated data from a single data collection tool such as this checklist has the potential to enable longitudinal studies of module condition over time, technology evolution, and field location for the enhancement of module reliability models.

14 SOLAR ENERGY↗