Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUMMARY REPORT FOR ZINC 65 CONTAMINATION CONTROL

Radioactive zinc, {sup 65}Zn, was detected after extraction of 215 TPBARs in from TVA reactor fuel cycle 6. A team consisting of Tritium Engineering, Tritium Operations, Tritium Radiation Control, and Savannah River National Laboratory personnel evaluated the risk and response and developed short, medium and long term goals for contamination control. One of the goals was incorporated into site Performance Based Incentive CO 3.4, to optimize the filter geometry and operating conditions for the Tritium Extraction Facility. This goal included a scoping study to determine if the contamination could be contained within the high radiation environment of the furnace module as well. In order to optimize the filters studies were conducted to independently evaluate the effect of pore size on pumping efficiency and zinc trapping efficiency (1). A study was also conducted to evaluate the effect of temperature on the trapping efficiency and adhesion (2). In addition, the potential for chemically trapping zinc in the lithium trap was evaluated using a thermodynamic study (3) followed by preliminary experimental testing (4). Based on the work that was completed it is determined that a 20 {mu}m filter heated to between 120 and 200 C will act as an effective physical trap for zinc vapors. It may be possible to chemically react zinc with copper or cobalt to form zinc intermetallic compounds or alloys but additional work under more prototypic conditions are required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing photonic ring-resonator filters for OH-suppressed near-infrared astronomy

Near-infrared wavelength observations are crucial for understanding numerous fields of astrophysics, such as supernova cosmology and positronium annihilation detection. However, current ground-based observations suffer from an enormous background due to OH emission in the upper atmosphere. One promising way to solve this problem is to use ring-resonator filters to suppress OH emission lines. Here, we discuss our optimization of ring-resonator filter performance from five perspectives: resonance wavelength matching, polarization-independent operation, low insertion loss, low-loss coupling to astronomical instruments, and broadband operation. In the end, we discuss next steps needed for reliable supernova and positronium observations, thus providing a roadmap for future advances in near-infrared astronomy.

42 ENGINEERING↗

Analytical Analysis of Ac and Dc Side Harmonics of Three-level Active Neutral Point Clamped Inverter with Space Vector Modulation

This paper presents a comprehensive analytical analysis of the ac and dc side harmonics of the three-level active neutral point clamped (ANPC) inverter with space vector modulation (SVM) scheme. An analytical model to calculate the harmonics of a three-level converter with SVM is developed. The ac side output voltage harmonics and dc side current harmonics characteristics are calculated and analyzed. With the developed models, the impact of interleaving on both sides harmonics are studied which considers the modulation index, interleaving angle, and power factor. The analysis provides guideline for interleaving angle optimization to reduce the ac side power filter and dc side dc-link capacitor. The relationship between electromagnetic interference (EMI) filter corner frequency and switching frequency is also analytically derived which provides guideline for switching frequency and EMI filter design optimization. Two paralleled three-level ANPC inverters are constructed and experimental results are presented to verify the analytical analysis.

Chen, Ruirui↗

Stepped Impedance Resonators in Triple Band Bandpass Filter Design for Wireless Communication Systems

Triple band microstrip tri-section bandpass filter using stepped impedance resonators (SIRs) is designed, simulated, built, and measured using hair pin structure. The complete design procedure is given from analytical stage to implementation stage with details The coupling between SIRs is investigated for the first time in detail by studying their effect on the filter characteristics including bandwidth, and attenuation to optimize the filter perfomance. The simulation of the filler is performed using method of moment based 2.5D planar electromagnetic simulator The filter is then implemented on RO4003 material and measured The simulation, and measured results are compared and found to be my close. The effect of coupling on the filter performance is then investigated using electromagnetic simulator It is shown that the coupling effect between SIRs can be used as a design knob to obtain a bandpass Idler with a better performance jar the desired frequency band using the proposed filter topology The results of this work can used in wireless communication systems where multiple frequency bandy are needed

42 ENGINEERING↗

Toward an Optimal Position for IVC Filters: Computational Modeling of the Impact of Renal Vein Inflow

The purpose of this report is to evaluate the hemodynamic effects of renal vein inflow and filter position on unoccluded and partially occluded IVC filters using three-dimensional computational fluid dynamics. Three-dimensional models of the TrapEase and Gunther Celect IVC filters, spherical thrombi, and an IVC with renal veins were constructed. Hemodynamics of steady-state flow was examined for unoccluded and partially occluded TrapEase and Gunther Celect IVC filters in varying proximity to the renal veins. Flow past the unoccluded filters demonstrated minimal disruption. Natural regions of stagnant/recirculating flow in the IVC are observed superior to the bilateral renal vein inflows, and high flow velocities and elevated shear stresses are observed in the vicinity of renal inflow. Spherical thrombi induce stagnant and/or recirculating flow downstream of the thrombus. Placement of the TrapEase filter in the suprarenal vein position resulted in a large area of low shear stress/stagnant flow within the filter just downstream of thrombus trapped in the upstream trapping position. Filter position with respect to renal vein inflow influences the hemodynamics of filter trapping. Placement of the TrapEase filter in a suprarenal location may be thrombogenic with redundant areas of stagnant/recirculating flow and low shear stress along the caval wall due to the upstream trapping position and the naturally occurring region of stagnant flow from the renal veins. Infrarenal vein placement of IVC filters in a near juxtarenal position with the downstream cone near the renal vein inflow likely confers increased levels of mechanical lysis of trapped thrombi due to increased shear stress from renal vein inflow.

59 BASIC BIOLOGICAL SCIENCES↗

Signal-to-noise assessment for diffusion tensor imaging with single data set and validation using a difference image method with data from a multicenter study

Purpose: To describe a quantitative method for determination of SNR that extracts the local noise level using a single diffusion data set. Methods: Brain data sets came from a multicenter study (eight sites; three MR vendors). Data acquisition protocol required b = 0, 700 s/mm{sup 2}, fov = 256 × 256 mm{sup 2}, acquisition matrix size 128 × 128, reconstruction matrix size 256 × 256; 30 gradient encoding directions and voxel size 2 × 2 × 2 mm{sup 3}. Regions-of-interest (ROI) were placed manually on the b = 0 image volume on transverse slices, and signal was recorded as the mean value of the ROI. The noise level from the ROI was evaluated using Fourier Transform based Butterworth high-pass filtering. Patients were divided into two groups, one for filter parameter optimization (N = 17) and one for validation (N = 10). Six white matter areas (the genu and splenium of corpus callosum, right and left centrum semiovale, right and left anterior corona radiata) were analyzed. The Bland–Altman method was used to compare the resulting SNR with that from the difference image method. The filter parameters were optimized for each brain area, and a set of “global” parameters was also obtained, which represent an average of all regions. Results: The Bland–Altman analysis on the validation group using “global” filter parameters revealed that the 95% limits of agreement of percent bias between the SNR obtained with the new and the reference methods were −15.5% (median of the lower limit, range [−24.1%, −8.9%]) and 14.5% (median of the higher limits, range [12.7%, 18.0%]) for the 6 brain areas. Conclusions: An FT-based high-pass filtering method can be used for local area SNR assessment using only one DTI data set. This method could be used to evaluate SNR for patient studies in a multicenter setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

We report past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal-to-background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09–360 ppb, a 1.4–13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1– 840 ppb),with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from0.5–2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4–2.4% RSD observed when no spatial filtering is used. In conclusion, spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of a Trapezoidal Filter to Waveforms from Silicone and Germanium Detectors

Application of a trapezoidal filter to data from a benchtop measurement and an experiment at DANCE is reported. The measurements were performed with a 252Cf source and sets of two and four Si detectors, respectively, recording the detectors waveforms for offline analysis. In addition, the trapezoidal filter was applied to data from an HPGe detector installed at DANCE. The parameters of the filter were optimized to provide the best energy resolution. The results of the trapezoidal filter are evaluated against the standard waveform-integration method.

47 OTHER INSTRUMENTATION↗

Excitation optimization for damage detection

A technique is developed to answer the important question: 'Given limited system response measurements and ever-present physical limits on the level of excitation, what excitation should be provided to a system to make damage most detectable?' Specifically, a method is presented for optimizing excitations that maximize the sensitivity of output measurements to perturbations in damage-related parameters estimated with an extended Kalman filter. This optimization is carried out in a computationally efficient manner using adjoint-based optimization and causes the innovations term in the extended Kalman filter to be larger in the presence of estimation errors, which leads to a better estimate of the damage-related parameters in question. The technique is demonstrated numerically on a nonlinear 2 DOF system, where a significant improvement in the damage-related parameter estimation is observed.

42 ENGINEERING↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying Optimal Measurement Subspace for the Ensemble Kalman Filter

To reduce the computational load of the ensemble Kalman filter while maintaining its efficacy, an optimization algorithm based on the generalized eigenvalue decomposition method is proposed for identifying the most informative measurement subspace. When the number of measurements is large, the proposed algorithm can be used to make an effective tradeoff between computational complexity and estimation accuracy. This algorithm also can be extended to other Kalman filters for measurement subspace selection.

99 GENERAL AND MISCELLANEOUS↗

Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters

Purpose: With the introduction of flattening filter free (FFF) linear accelerators to radiation oncology, new analytical source models for a FFF beam applicable to current treatment planning systems is needed. In this work, a multisource model for the FFF beam and the optimization of involved model parameters were designed. Methods: The model is based on a previous three source model proposed by Yang et al. [''A three-source model for the calculation of head scatter factors,'' Med. Phys. 29, 2024-2033 (2002)]. An off axis ratio (OAR) of photon fluence was introduced to the primary source term to generate cone shaped profiles. The parameters of the source model were determined from measured head scatter factors using a line search optimization technique. The OAR of the photon fluence was determined from a measured dose profile of a 40x40 cm{sup 2} field size with the same optimization technique, but a new method to acquire gradient terms for OARs was developed to enhance the speed of the optimization process. The improved model was validated with measured dose profiles from 3x3 to 40x40 cm{sup 2} field sizes at 6 and 10 MV from a TrueBeam STx linear accelerator. Furthermore, planar dose distributions for clinically used radiation fields were also calculated and compared to measurements using a 2D array detector using the gamma index method. Results: All dose values for the calculated profiles agreed with the measured dose profiles within 0.5% at 6 and 10 MV beams, except for some low dose regions for larger field sizes. A slight overestimation was seen in the lower penumbra region near the field edge for the large field sizes by 1%-4%. The planar dose calculations showed comparable passing rates (>98%) when the criterion of the gamma index method was selected to be 3%/3 mm. Conclusions: The developed source model showed good agreements between measured and calculated dose distributions. The model is easily applicable to any other linear accelerator using FFF beams as the required data include only the measured PDD, dose profiles, and output factors for various field sizes, which are easily acquired during conventional beam commissioning process.

60 APPLIED LIFE SCIENCES↗

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium β-decay endpoint. Here, we detail the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.

47 OTHER INSTRUMENTATION↗

Optimized beam sculpting with generalized fringe-rate filters

We generalize the technique of fringe-rate filtering, whereby visibilities measured by a radio interferometer are re-weighted according to their temporal variation. As the Earth rotates, radio sources traverse through an interferometer’s fringe pattern at rates that depend on their position on the sky. Capitalizing on this geometric interpretation of fringe rates, we employ time-domain convolution kernels to enact fringe-rate filters that sculpt the effective primary beam of antennas in an interferometer. As we show, beam sculpting through fringe-rate filtering can be used to optimize measurements for a variety of applications, including mapmaking, minimizing polarization leakage, suppressing instrumental systematics, and enhancing the sensitivity of power-spectrum measurements. We show that fringe-rate filtering arises naturally in minimum variance treatments of many of these problems, enabling optimal visibility-based approaches to analyses of interferometric data that avoid systematics potentially introduced by traditional approaches such as imaging. Our techniques have recently been demonstrated in Ali et al., where new upper limits were placed on the 21 cm power spectrum from reionization, showcasing the ability of fringe-rate filtering to successfully boost sensitivity and reduce the impact of systematics in deep observations.

79 ASTRONOMY AND ASTROPHYSICS↗

RBFNN-based Minimum Entropy Filtering for a Class of Stochastic Nonlinear Systems

This paper presents a novel minimum entropy filter design for a class of stochastic nonlinear systems which are subjected to non-Gaussian noises. Motivated by stochastic distribution control, an output entropy model is developed using RBF neural network while the parameters of the model can be identified by the collected data. Based upon the presented model, the filtering problem has been investigated while the system dynamics have been represented. As the model output is the entropy of the estimation error, the optimal nonlinear filter is obtained based on the Lyapunov design which makes the model output minimum. Moreover, the entropy assignment problem has been discussed as an extension of the presented approach. To verify the presented design procedure, a numerical example is given which illustrates the effectiveness of the presented algorithm. The contributions of this paper can be included as 1) an output entropy model is presented using neural network; 2) a nonlinear filter design algorithm is developed as the main result and 3) a solution of entropy assignment problem is obtained which is an extension of the presented framework.

42 ENGINEERING↗

Optimization of processor allocation for domain decomposed Monte Carlo calculations

Load imbalance plagues domain decomposed Monte Carlo calculations when sources are not uniform. Parallel efficiency for domain decomposed Monte Carlo transport calculations improves through a nonuniform allocation of processors over subdomains. In this work, we optimize the allocation with runtime diagnostics collected during a calibration step, then complete the full calculation. The diagnostic-based approach is compared to implicit filtering, an optimization algorithm for bound constrained noisy optimization problems. Finally, we consider both forward and hybrid radiation transport calculations to measure performance.

97 MATHEMATICS AND COMPUTING↗