Search NASA⌕ Search

SEARCH · Search NASA

Results for “fire detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Fire Front Detection and Tracking for Autonomous sUAS in STEReO

The Scalable Traffic Management Emergency Response Operations (STEReO) project aims to incorporate unmanned aerial systems (UAS) into wildfire incident response to safely quicken response times, improve operator awareness, and scale-up aircraft operations.Autonomous UAS can be used to relieve human operators of dull, dirty, and dangerous tasks such as checking for re-ignitions and geo-locating fires. To geo-locate fires, the UAS must be able to detect whether a fire is present and also have the necessary information to stamp a location. Furthermore, the UAS should be able to track the fire front to determine the extent of the fire. This study presents a fire front detection and tracking methodology for an autonomous small UAS (sUAS). The methodology is evaluated in simulation.

Autonomous UAV,Wildfire,Detection,Tracking↗

Intercomparison of MODIS AQUA and VIIRS I-Band Fires and Emissions in an Agricultural Landscape - Implications for Air Pollution Research

Quantifying emissions from crop residue burning is crucial as it is a significant source of air pollution. In this study, we first compared the fire products from two different sensors, the Visible Infrared Imaging Radiometer Suite (VIIRS) 375 m active fire product (VNP14IMG) and Moderate Resolution Imaging Spectroradiometer (MODIS) 1 km fire product (MCD14ML) in an agricultural landscape, Punjab, India. We then performed an intercomparison of three different approaches for estimating total particulate matter (TPM) emissions which includes the fire radiative power (FRP) based approach using VIIRS and MODIS data, the Global Fire Emissions Database (GFED) burnt area emissions and a bottom-up emissions approach involving agricultural census data. Results revealed that VIIRS detected fires were higher by a factor of 4.8 compared to MODIS Aqua and Terra sensors. Further, VIIRS detected fires were higher by a factor of 6.5 than Aqua. The mean monthly MODIS Aqua FRP was found to be higher than the VIIRS FRP; however, the sum of FRP from VIIRS was higher than MODIS data due to the large number of fires detected by the VIIRS. Besides, the VIIRS sum of FRP was 2.5 times more than the MODIS sum of FRP. MODIS and VIIRS monthly FRP data were found to be strongly correlated (r2 = 0.98). The bottom-up approach suggested TPM emissions in the range of 88.19-91.19 Gg compared to 42.0-61.71 Gg, 42.59-58.75 Gg and 93.98-111.72 Gg using the GFED, MODIS FRP, and VIIRS FRP based approaches, respectively. Of the different approaches, VIIRS FRP TPM emissions were highest. Since VIIRS data are only available since 2012 compared to MODIS Aqua data which have been available since May 2002, a prediction model combining MODIS and VIIRS FRP was derived to obtain potential TPM emissions from 2003-2016. The results suggested a range of 2.56-63.66 (Gg) TPM emissions per month, with the highest crop residue emissions during November of each year. Our results on TPM emissions for seasonality matched the ground-based data from the literature. As a mitigation option, stringent policy measures are recommended to curtail agricultural residue burning in the study area.

Global Fire Emissions Database (GFED)↗

Using the NASA NEESPI Portal Data to Study Land, Climate, and Socio-Economic Changes in Northern Eurasia

A large number of fires detected in July of 2003 - a nearly 200-time increase in fire detections compared to other years during 2001-2006. despite the summer monsoon suppression of large fire occurrence. Traditional vegetation indices (NDVI and EVI) included in operational fire danger assessment provide little information on the fuel state in this ecosystem pre- or post-fire. No considerable differences in surface temperature and soil moisture in July were observed between the catastrophic year of 2003 and the two subsequent years of low summer fire occurrence of 2004 and 2005. However, the temporal analysis indicates that dry spring conditions in 2003 (detected through low soil moisture measurements in April and May) may have led to a stressed vegetative state and created conditions conducive to catastrophic fire occurrence.

Leptoukh, Gregory↗

Next generation fire suppressants

Spectrex, Inc., located in Cedar Grove, NJ is a manufacturer of fire detection and suppression equipment. Spectrex is one of the original pioneers in high speed fire detection and suppression systems for combat vehicles. Spectrex has installed fire suppressions systems in thousands of combat vehicles and ships throughout the world. Additionally, they manufacture flame explosion detectors, ship damage control systems, and optical gas and vapor detectors. The culmination of several years of research and development has recently produced an innovative electro-optical continuous monitoring systems called SharpEye 20/20I IR(sup 3) and SAFEYE that provide fast and reliable gas, vapor, aerosol, flame, and explosion detection. SharpEye 20/20I IR(sup 3) is a self-contained triple spectrum flame detector which scans for oscillating IR radiation (1 to 10 Hz) in the spectral bands ranging from 4.0 to 5.0 microns and uses programmed algorithms to check the ratio and correlation of data received by the three sensors to make the system highly immune to false alarms. It is extremely sensitive as it can detect a 1 x 1 square foot gasoline pan fire at 200 feet in less than 3 seconds. The sensitivity is user programmable, offering 4 ranges of detection. SAFEYE is comprised of a selected number of multispectral ban microprocessors controlled detectors which are in communication with one or more radiation sources that is projected along a 600 feet optical path. The signals from the selected narrow bands are processed and analyzed by highly sophisticated algorithms. It is ideal for high risk, remote, large areas such as petroleum and chemical manufacturing sites, waste dumps, aircraft cargo bays, and ship compartments. The SAFEYE will perform direct readings of the presence or rate of rise of concentrations of gases, vapors, or aerosols at the range of parts per million and provide alarms at various set points at different levels of concentrations.

Brown, Jerry A.↗

Creating IR-verified Gridded Fire Burn Maps using Public NASA and Satellite Data

Even though fire can be devastating, wildland fire is a natural and integral force on our landscapes, providing value by decreasing fuels at the Wildland Urban Interface (WUI) to promote safe communities. However, uncontained wildfires can devastate communities, threaten our health, and result in substantial economic losses. There has been greater than a $50B increase in wildfire insurance claims from 2017-2021, which has been exacerbated by climate change. Our partners at Kettle reinsurance are focused on building a smarter reinsurance model for protecting today’s globalized world from the catastrophic effects of climate change. Our objective is to develop a high-confidence grid-based wildfire burn product using multiple sources of satellite data to determine whether a ‘conflagration' (fire larger than 999+ acres) has ‘breached’ a grid cell. This product will substantially decrease the time it takes for homeowners to receive payouts, from over a year to a couple months. Working with our partners at Kettle reinsurance, we use VIIRS (Visible Infrared Imaging Radiometer Suite) 375 m fire detections and Sentinel-2 10 m satellite imagery to create a 20-m gridded fire burn product. Our process is based on the level of confidence in the data source and takes into account vegetation change throughout the life of the fire. For example, Sentinel-2 vegetation-change indices have a higher level of confidence when congruent with VIIRS active-fire detection data, rather than VIIRS detections alone. We have also verified our fire burn product against MODIS/ASTER Airborne Simulator (MASTER) Infrared (IR) data from the Fire Influence on Regional to Global Environments Experiment - Air Quality (FIREX-AQ) 2019 campaign, with 88% overall agreement. The first iteration has been developed for responding to wildfires in California, with the possibility to expand nationwide and globally.

Emily Gargulinski↗

Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems

Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

Friedman, Robert↗

Contributions of microgravity test results to the design of spacecraft fire-safety systems

Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

Friedman, Robert↗

Satellite Investigations of Fire, Smoke, and Carbon Monoxide during April 1994 MAPS Mission: Case Studies over Tropical Asia

During April 9-19, 1994, the Measurement of Air Pollution from Satellites (MAPS) measured free tropospheric carbon monoxide (CO) concentrations on a near-global basis. For these eleven days the global lkm advanced very high resolution radiometer (AVHRR) Pathfinder data are used to detect fires and smoke over the Indo-Burma region (85 degrees E - 110 degrees E; 10 degrees N -30 degrees N). The fire activities are categorized for four major ecosystems that include (1) cropland/natural vegetation mosaic (CNVM), (2) evergreen broadleaf forest (EBF), (3) mixed forest (MFD), and (4) grassland (GL). Using published emission rates between particulate matter and carbon monoxide concentrations from temperate areas, the fire counts along with other information are used to obtain estimates of CO concentrations from the AVERR data. More than 7000 fires are detected during the study period with 23%, 43%, 24%, and 10% fires in the CNVM, EBF, MFD, and GL ecosystems, respectively. The enhanced CO concentrations over the area of study are either over or downwind of the fires detected by the AVHRR. The preliminary AVHRR estimates of CO concentrations are smaller than the MAPS-measured values by a factor of 4 to 5 for fire counts areater than 200. The differences are attributed to the lack of transport mechanisms and other assumptions in the current model. However, these results show a good potential for usino the AVHRR measurements to detect fires and smoke and also to estimate CO concentrations.

Christopher, Sundar A.↗

Automated Wildfire Detection Through Artificial Neural Networks

We have tested and deployed Artificial Neural Network (ANN) data mining techniques to analyze remotely sensed multi-channel imaging data from MODIS, GOES, and AVHRR. The goal is to train the ANN to learn the signatures of wildfires in remotely sensed data in order to automate the detection process. We train the ANN using the set of human-detected wildfires in the U.S., which are provided by the Hazard Mapping System (HMS) wildfire detection group at NOAA/NESDIS. The ANN is trained to mimic the behavior of fire detection algorithms and the subjective decision- making by N O M HMS Fire Analysts. We use a local extremum search in order to isolate fire pixels, and then we extract a 7x7 pixel array around that location in 3 spectral channels. The corresponding 147 pixel values are used to populate a 147-dimensional input vector that is fed into the ANN. The ANN accuracy is tested and overfitting is avoided by using a subset of the training data that is set aside as a test data set. We have achieved an automated fire detection accuracy of 80-92%, depending on a variety of ANN parameters and for different instrument channels among the 3 satellites. We believe that this system can be deployed worldwide or for any region to detect wildfires automatically in satellite imagery of those regions. These detections can ultimately be used to provide thermal inputs to climate models.

Miller, Jerry↗

Development of Microfabricated Chemical Gas Sensors and Sensor Arrays for Aerospace Applications

Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring, fire detection, and environmental monitoring. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. However, due to issues of selectivity and cross-sensitivity, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. This paper discusses the needs of space applications as well as the point-contact sensor technology and sensor arrays being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, hydrazine, nitrogen oxides (NO,), carbon monoxide, oxygen, and carbon dioxide are being developed as well as arrays for leak, fire, and emissions detection. Demonstrations of the technology will also be discussed. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

Hunter, G. W.↗

Dynamic fire and smoke detection and classification for flashover prediction

Flashover is a dangerous phenomenon caused by near-simultaneous ignition of exposed materials. It is one of the major causes of firefighter fatalities. Research has been done using CMOS vision cameras combined with thermal sensors to perform remote detection and dynamic classification of fire and smoke patterns. Tests and experiments have been done to detect fire and smoke remotely. The inexpensive visible and infrared sensors used in the tests corroborate and closely follow the detailed trends recorded by the more expensive (and less mobile) radiometers and thermocouples. Deep neural networks (DNN) have been used to detect, classify and track fire and smoke areas. Real-time segmentation is utilized to measure the fire and smoke boundaries. The segmentations are used to dynamically monitor fluctuations in temperature, fire size and smoke progression in the monitored areas. A fire and smoke progression curve has been drawn to predict the flashover point. In the paper, data analysis and preliminary results will be shown. Keywords: Flashover, fire, smoke, deep learning, visible and infrared vision

Chow, Edward↗

Modelling Framework For Fire And Smoke Detection In Imagery

This framework was developed to ingest images/video images to train and test artificial neural network structures for image-based detection of fire and smoke. The code includes data preprocessing, model development, and testing. The framework is designed to work with RGB video imagery.

Griffel, LloydM.↗

Shooter Alarm System Final Report FY23

Lawrence Livermore National Laboratory (LLNL) is developing a multiphysics sensor package for automatic live arms fire detection for use in schools, houses of worship, hospi tals, etc. The goal is to have a package the size of a common smoke or CO2 detector with a price point of $50 or less which may be deployed throughout the aforementioned facilities. The commercial device will detect live gun fire with low probability of false alarm and auto matically alert first responders. A prototype board with four accelerometers, two infrared (IR) and two microphones has been developed and deployed at two experiments at LLNL’s Small Firearms Training Facility (SFTF). The device successfully and consistently measured signals on the accelerometer and acoustic channels. IR responses were measured depending upon the environment and sound source.

42 ENGINEERING↗

System safety as applied to Skylab

Procedural and organizational guidelines used in accordance with NASA safety policy for the Skylab missions are outlined. The basic areas examined in the safety program for Skylab were the crew interface, extra-vehicular activity (EVA), energy sources, spacecraft interface, and hardware complexity. Fire prevention was a primary goal, with firefighting as backup. Studies of the vectorcardiogram and sleep monitoring experiments exemplify special efforts to prevent fire and shock. The final fire control study included material review, fire detection capability, and fire extinguishing capability. Contractors had major responsibility for system safety. Failure mode and effects analysis (FMEA) and equipment criticality categories are outlined. Redundancy was provided on systems that were critical to crew survival (category I). The five key checkpoints in Skylab hardware development are explained. Skylab rescue capability was demonstrated by preparations to rescue the Skylab 3 crew after their spacecraft developed attitude control problems.

Kleinknecht, K. S.↗

Spacecraft Fire Safety: A Human Space Flight Program Perspective

This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

Pedley, Michael D.↗

A Small Angle Scattering Sensor System for the Characterization of Combustion Generated Particulate

One of the critical issues for the US space program is fire safety of the space station and future launch vehicles. A detailed understanding of the scattering signatures of particulate is essential for the development of a false alarm free fire detection system. This paper describes advanced optical instrumentation developed and applied for fire detection. The system is being designed to determine four important physical properties of disperse fractal aggregates and particulates including size distribution, number density, refractive indices, and fractal dimension. Combustion generated particulate are the primary detection target; however, in order to discriminate from other particulate, non-combustion generated particles should also be characterized. The angular scattering signature is measured and analyzed using two photon optical laser scattering. The Rayleigh-Debye-Gans (R-D-G) scattering theory for disperse fractal aggregates is utilized. The system consists of a pulsed laser module, detection module and data acquisition system and software to analyze the signals. The theory and applications are described.

Feikema, Douglas A.↗

A Multi-Analysis Approach for Estimating Regional Health Impacts from the 2017 Northern California Wildfires

In the evening of October 8 and early hours of October 9, 2017, high winds in Northern California downed trees and power lines, igniting some of the most devastating wildfires the state had seen, and within hours unhealthy air quality impacted millions of people. We simulated these air quality conditions using fire detection information from the MODIS, VIIRS, and GOES-16 ABI satellite instruments, and applying a set of three WRF–CMAQ simulations, one data fusion, and three machine learning methods. We investigated using the 5-min available GOES-16 fire detection data to simulate timing of fire activity to allocate emissions hourly for the WRF-CMAQ air quality modeling system. Interestingly, this approach did not necessarily improve results compared to the baseline case, which used a default time profile. However, this approach was key to simulating the initial 12-hr explosive fire activity and smoke impacts. The WRF-CMAQ simulations compared well with observational data for the October 8-15 time period and tended to overestimate concentrations October 16-20. To improve these results, we applied three machine learning algorithms. We also had a unique opportunity to evaluate results with temporary monitors deployed specifically for wildfires, and performance was markedly different. For example, at the permanent monitoring locations, the WRF-CMAQ simulations had a Pearson correlation of 0.65, and the data fusion approach improved this (Pearson correlation = 0.95), while at the temporary monitor locations across the WRF-CMAQ, data fusion, and machine learning datasets, the best Pearson correlation was 0.5. The data fusion and machine learning results were biased low and WRF-CMAQ results were biased high. Finally, we applied the optimized PM2.5 exposure estimate in a short-term exposure-response function. Total estimated mortality attributable to PM2.5 exposure during the smoke episode was 83 (95% confidence interval: 0, 196) with 47% of these deaths attributable to wildland fire smoke.

O'Neill, Susan↗