Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

Materials were developed to improve aircraft interior materials by modifying existing polymer structures, refining the process parameters, and by the use of mechanical configurations designed to overcome specific deficiencies. The optimization, selection, and fabrication of five fire resistant, low smoke emitting open cell foams are described for five different types of aircraft cabin structures. These include: resilient foams, laminate floor and wall paneling, thermal/acoustical insulation, molded shapes, and coated fabrics. All five have been produced from essentially the same polyimide precursor and have resulted in significant benefits from transfer of technology between the various tasks.

Gagliani, J.↗

Development of a protective decorative fire resistant low smoke emitting, thermally stable coating material

The development of suitable electrocoatings and subsequent application to nonconductive substrates are discussed. Substrates investigated were plastics or resin-treated materials such as FX-resin (phenolic-type resin) impregnated fiberglass mat, polyphenylene sulfide, polyether sulfone and polyimide-impregnated unidirectional fiberglass. Efforts were aimed at formulating a fire-resistant, low smoke emitting, thermally stable, easily cleaned coating material. The coating is to be used for covering substrate panels, such as aluminum, silicate foam, polymeric structural entities, etc., all of which are applied in the aircraft cabin interior and thus subject to the spillages, scuffing, spotting and the general contaminants which prevail in aircraft passenger compartments.

Source record↗

Measurement of Fire Radiative Energy from Space and Implications for Fire-Disaster Monitoring and Smoke Emissions Modeling

Measurement of fire radiative energy (FRE) release rate or power (FRP) from satellite provides a vital mechanism for distinguishing different strengths of fires. Analysis of 1-km resolution fire data, acquired globally by the MODerate-resolution Imaging Spectro-radiometer (MODIS) sensor aboard the Terra and Aqua satellites from 2000 to 2006, showed instantaneous FRP values ranging between 0.02 MW and 1866 MW, to which simple thresholds can be applied to categorize fires by strength, in a similar fashion as the strengths of earthquakes and hurricanes. Analysis of regional mean FRP per unit area of land (FRP flux) shows that at peak fire season in certain regions, fires can be responsible for up to 0.2 W/m2 at peak time of day. When considered as the active fire contribution to the direct surface radiative forcing (RF) in the different fire regions, this order of magnitude of FRF fluxes is non negligible. It has been determined experimentally that the amount of FRE released by a fire over the course of its duration is directly proportional to the amount of biomass consumed by it. Furthermore, at the satellite observation scale, the rate of release of FRE (i.e. FRP) is proportional to the rate of biomass consumption, and that of emission of smoke particulates and eventually also other smoke constituents. Therefore, current research efforts are geared toward deriving simple parameterizations that will facilitate direct input of FRP measurements in models, not only to improve the accuracy of burned-biomass and smoke emissions estimations, but also to reduce the hitherto practiced heavy reliance on multiple indirect parameters with indeterminate uncertainties.

Ichoku, Charles↗

Swelling of Transported Smoke from Savanna fires over the Southeast Atlantic Ocean

We use the recently released Version 4 (V4) lidar data products from CALIPSO to study the smoke plumes transported from Southern African biomass burning areas. The significant improvements in CALIPSO V4 Level 1 calibration and the V4 Level 2 aerosol subtyping algorithms, the latter being particularly relevant to biomass burning smoke over this area, lead to a better representation of their optical properties. For the first time, we show evidence of smoke particles increasing in size, evidenced in their particulate color ratios, as they are transported over the South Atlantic Ocean from the source regions over Southern Africa. This is likely due to hygroscopic swelling of the smoke particles and is reflected in the higher relative humidity in the middle troposphere for profiles with smoke. This finding may have implications for radiative forcing estimates over this area and is relevant to the ORACLES field mission that is currently underway.

Kar, J.↗

Swelling of Transported Smoke from Savanna Fires over the Southeast Atlantic Ocean

We use the recently released Cloud Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) Version 4.1 (V4) lidar data to study the smoke plumes transported from Southern African biomass burning areas. Significant improvements in the CALIPSO V4 Level 1 calibration and V4 Level 2 algorithms lead to a better representation of their optical properties, with the aerosol subtype improvements being particularly relevant to smoke over this area. For the first time, we show evidence of smoke particles increasing in size, evidenced in their particulate color ratios, as they are transported over the South Atlantic Ocean from the source regions over Southern Africa. We hypothesize that this is due to hygroscopic swelling of the smoke particles and is reflected in the higher relative humidity in the middle troposphere for profiles with smoke. This finding may have implications for radiative forcing estimates over this area and is also relevant to the ORACLES field mission.

Kar, J.↗

Swelling of Transported Smoke from Savanna Fires over the Southeast Atlantic Ocean

We use the recently released Cloud Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) Version 4.1 (V4) lidar data to study the smoke plumes transported from Southern African biomass burning areas. Significant improvements in the CALIPSO V4 Level 1 calibration and V4 Level 2 algorithms lead to a better representation of their optical properties, with the aerosol subtype improvements being particularly relevant to smoke over this area. For the first time, we show evidence of smoke particles increasing in size, as demonstrated by their particulate color ratios, as they are transported over the South Atlantic Ocean from the source regions over Southern Africa. We hypothesize that this is due to hygroscopic swelling of the smoke particles and is reflected in the higher relative humidity in the middle troposphere for profiles with smoke. This finding may have implications for radiative forcing estimates over this area and is also relevant to the ORACLES field mission.

J. Kar↗

Pacific Northwest Health & Air Quality - Utilizing NASA Earth Observations to Analyze Air Quality Impacts from Wildfires in the Pacific Northwest

The Pacific Northwest region of the United States and Canada has become more vulnerable to intense wildfire regimes due to years of fire suppression and climatic changes. Smoke from fires exposes communities to hazardous aerosols and pollutants known to trigger asthma symptoms and exacerbate other respiratory and cardiovascular diseases. In partnership with The Nature Conservancy’s Washington Chapter and the Puget Sound Clean Air Agency, NASA DEVELOP investigated the impacts of wildfire smoke on air quality from 2008 to 2020 using NASA Earth observations. To explore the various dimensions of smoke and its relation to air quality, the team looked at the vertical extent of smoke plumes and the resulting changes in air quality. The team evaluated the potential relationship between plume height of wildfire smoke and fire radiative power using the Moderate Resolution Imaging Spectroradiometer (MODIS) aboard the Aqua and Terra satellites and Terra’s Multi-angle Imaging SpectroRadiometer (MISR) using the MISR INteractive eXplorer (MINX). The team determined that there was no regional relationship between fire radiative power and smoke plume height. To investigate changes in air quality resulting from wildfire smoke, the team utilized data from NASA’s Fire Information for Resource Management System, from the European Space Agency’s Sentinel-5P Tropospheric Monitoring Instrument (TROPOMI), and true color imagery from Landsat 8 Operational Land Imager (OLI). The team created a Google Earth Engine-based (GEE) web tool to visualize changes in atmospheric pollutants and aerosol optical depth. Results of case study fires showed varying increases in pollutant concentrations when compared to a baseline map. The end products provided the partners with tools to quantify plume height using MINX and to visualize recent air quality patterns relating to variations in wildfire extent and severity in the Pacific Northwest

Ani Matevosian↗

Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

A new approach to the problem of flammability by the use of materials obtained from foamy polyimide resins is developed. The ability of these materials to provide fire protection is demonstrated. The development of processes for producing resilient cell foam for use in aircraft seating, thermal acoustical insulation, floor and wall panels, coated glass fabrics, and molded hardware.

Gagliani, J.↗

Development of fire-resistant, low smoke generating, thermally stable end items for commercial aircraft and spacecraft using a basic polyimide resin

A terpolyimide precursor was developed which can be foamed by microwave methods and yields foams possessing the best seating properties. A continuous process, based on spray drying techniques, permits production of polyimide powder precursors in large quantities. The constrained rise foaming process permits fabrication of rigid foam panels with improved mechanical properties and almost unlimited density characteristics. Polyimide foam core rigid panels were produced by this technique with woven fiberglass fabric bonded to each side of the panel in a one step microwave process. The fire resistance of polyimide foams was significantly improved by the addition of ceramic fibers to the powder precursors. Foams produced from these compositions are flexible, possess good acoustical attenuation and meet the minimum burnthrough requirements when impinged by high flux flame sources.

Gagliani, J.↗

Development of lightweight, fire-retardant, low smoke, high strength, thermally stable aircraft floor paneling

Boeing's participation in a NASA funded program (FIREMEN) to develop materials for use as floor panels possessing flammability, smoke and toxicity characteristics superior to current materials is outlined. The objectives of the program are to develop an aircraft floor paneling suitable for high traffic areas, e.g., aisle or galley and to install and certify the panel in a commercial aircraft for service evaluation.

Anderson, R. A.↗

Development of fire-resistant, low smoke generating, thermally stable end items for commercial aircraft and spacecraft using a basic polyimide resin

Experimental data pertinent to flexible resilient foams, low density wall panels, high strength floor panels and thermal acoustical insulation are presented. An evaluation of the effect of the heterocyclic diamine component on the compression set of the foams was carried out. Processes and compositions for fabricating wall panels were evaluated. Thermal acoustical polyimide materials were developed to replace conventional glass batting insulation. To reduce the thermal stresses and improve the burn through resistance, cross linked polyimide foams were developed but not evaluated.

Gagliani, J.↗

Research Plan for Fire Signatures and Detection

Viewgraphs on the prevention, suppression, and detection of fires aboard a spacecraft is presented. The topics include: 1) Fire Prevention, Detection, and Suppression Sub-Element Products; 2) FPDS Organizing Questions; 3) FPDS Organizing Questions; 4) Signatures, Sensors, and Simulations; 5) Quantification of Fire and Pre-Fire Signatures; 6) Smoke; 7) DAFT Hardware; 8) Additional Benefits of DAFT; 9) Development and Characterization of Sensors 10) Simulation of the Transport of Smoke and Fire Precursors; and 11) FPDS Organizing Questions.

Source record↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire Safety↗

Evaluation of Low-Gravity Smoke Particulate for Spacecraft Fire Detection

Tests were conducted on the International Space Station to evaluate the smoke particulate size from materials and conditions that are typical of those expected in spacecraft fires. Five different materials representative of those found in spacecraft (Teflon, Kapton, cotton, silicone rubber and Pyrell) were heated to temperatures below the ignition point with conditions controlled to provide repeatable sample surface temperatures and air flow. The air flow past the sample during the heating period ranged from quiescent to 8 cm/s. The effective transport time to the measurement instruments was varied from 11 to 800 seconds to simulate different smoke transport conditions in spacecraft. The resultant aerosol was evaluated by three instruments which measured different moments of the particle size distribution. These moment diagnostics were used to determine the particle number concentration (zeroth moment), the diameter concentration (first moment), and the mass concentration (third moment). These statistics were combined to determine the diameter of average mass and the count mean diameter and by assuming a log-normal distribution, the geometric mean diameter and the geometric standard deviations were also calculated. Smoke particle samples were collected on TEM grids using a thermal precipitator for post flight analysis. The TEM grids were analyzed to determine the particle morphology and shape parameters. The different materials produced particles with significantly different morphologies. Overall the majority of the average smoke particle sizes were found to be in the 200 to 400 nanometer range with the quiescent cases and the cases with increased transport time typically producing with substantially larger particles. The results varied between materials but the smoke particles produced in low gravity were typically twice the size of particles produced in normal gravity. These results can be used to establish design requirements for future spacecraft smoke detectors.

Fire↗

Development of lightweight fire retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

Fire resistance mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesives to Nomex honeycomb core. The test results were compared to proposed and current requirements for aircraft floor panel applications to demonstrate that the fire safety of the airplane could be improved without sacrificing mechanical performance of the aircraft floor panels.

Arnold, D. B.↗

Development of lightweight, fire-retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

Extensive fire resistance and mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesive to Nomex honeycomb and foam core. The test results were used to select a combination of materials that would improve the fire safety of the airplane without sacrificing mechanical performance of the aircraft floor panels. A test panel is being service evaluated in a commercial aircraft.

Anderson, R. A.↗

Thanksgiving Hocus Pocus

I was managing the construction project, and I thought my biggest challenge was simply finishing the work in time for start of the holiday shopping season. The store opened three weeks before Thanksgiving. Everything looked great. Business picked up steadily as the serious spending season approached. Then, two days before Thanksgiving, disaster struck. The fire protection system was designed to prevent smoke and fire from reaching the merchandise. If a fire alarm went off anywhere in the building, the system went into a massive pressurization mode. Dampers would open and the system would pump in hundreds of cubic feet of air from outside into the store, pressurizing every square foot, preventing fire or smoke from spreading into the store. That night an unknown event tripped the alarm-and it sounded for six hours. The air conditioning system was still operational as the outside air temperatures had been warm all month. That night, however, temperatures plummeted to 20 degrees. With an alarm sounding in a building complex that covers many millions of square feet, no one paid attention to the cold air flowing into the space. Pipes froze and burst. Hundreds of gallons of water came down through the drywall, soaking merchandise, the carpet and the hardwood racks. This state of the art system, which had been designed to protect, was now responsible for unthinkable damage. You could be the among greatest project managers in world, but if you have an attitude and you give the client heartburn, unnecessary heartburn, you're not going to do more work with him. If you have a disaster like this one, and you manage to make everybody feel good and believe that you are going to take care of them, then everybody looks back on it and says, "You know what, this is a good project team; we work well together, so let's do another one."

Zazzali, Christian↗

Upper Troposphere Smoke Injection From Large Areal Fires

Abstract Large areal fires, such as those ignited following a nuclear detonation, can inject smoke into the upper troposphere and lower stratosphere. Detailed fire simulations allow for assessment of how local weather interacts with these fires and affects smoke lofting. In this study, we employ the fire simulation package in the Weather Research and Forecasting (WRF‐Fire) model, Version 4.0.1, to explore how smoke lofting from a fire burning a homogeneous fuel bed changes with varying local winds, relative humidity, and atmospheric boundary‐layer stability for two different‐sized areal fires. The presence of moisture has the greatest influence on the results by raising the altitude of lofting, while faster wind speeds dampen lofting and lower the injection height. Stably stratified conditions inhibit plume propagation compared with neutrally stratified conditions, although the impact of stability is not as strong as that of moisture and winds. These findings highlight the importance of using an appropriate atmospheric profile when simulating large fires, as the local weather can have a meaningful influence on smoke lofting.

54 ENVIRONMENTAL SCIENCES↗