Search NASA⌕ Search

SEARCH · Search NASA

Results for “flight data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Searches for long-lived charged particles in pp collisions at $\sqrt{s}$ = 7 and 8 TeV

Results of searches for heavy stable charged particles produced in pp collisions at $\sqrt{s}$ =7 and 8 TeV are presented corresponding to an integrated luminosity of 5.0 fb -1 and 18.8 fb -1 , respectively. Data collected with the CMS detector are used to study the momentum, energy deposition, and time-of-flight of signal candidates. Leptons with an electric charge between e/3 and 8e, as well as bound states that can undergo charge exchange with the detector material, are studied. Analysis results are presented for various combinations of signatures in the inner tracker only, inner tracker and muon detector, and muon detector only. Detector signatures utilized are long time-of-flight to the outer muon system and anomalously high (or low) energy deposition in the inner tracker. The data are consistent with the expected background, and upper limits are set on the production cross section of long-lived gluinos, scalar top quarks, and scalar τ leptons, as well as pair produced long-lived leptons. Corresponding lower mass limits, ranging up to 1322 GeV/c (2) for gluinos, are the most stringent to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multivariate Analysis of MALDI Imaging Mass Spectrometry Data of Mixtures of Single Pollen Grains

Mixtures of pollen grains of three different species (Corylus avellana, Alnus cordata, and Pinus sylvestris) were investigated by matrix-assisted laser desorption/ionization time-of-flight imaging mass spectrometry (MALDI-TOF imaging MS). The amount of pollen grains was reduced stepwise from > 10 to single pollen grains. For sample pretreatment, we modified a previously applied approach, where any additional extraction steps were omitted. Our results show that characteristic pollen MALDI mass spectra can be obtained from a single pollen grain, which is the prerequisite for a reliable pollen classification in practical applications. MALDI imaging of laterally resolved pollen grains provides additional information by reducing the complexity of the MS spectra of mixtures, where frequently peak discrimination is observed. Combined with multivariate statistical analyses, such as principal component analysis (PCA), our approach offers the chance for a fast and reliable identification of individual pollen grains by mass spectrometry. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring higher-order moments of neutron-time-of-flight data for cryogenic inertial confinement fusion implosions on OMEGA

Ion temperatures serve as an important diagnostic for inertial confinement fusion (ICF) implosions. In direct-drive ICF experiments on OMEGA, neutron-time-of-flight (nTOF) data are used to infer the ion temperature of the fusing plasma produced in the implosion experiment. The analysis of the nTOF data requires an assumption about the shape of the underlying source signal. Since the source nTOF signal is a near-replica of the neutron energy spectrum, an ideal Gaussian shape, corresponding to the neutron energy spectrum of a uniform temperature plasma, is routinely employed. However, spatial and temporal variations of the ion temperature in the plasma give rise to higher-order moments, which were first described by Munro [Nucl. Fusion 56, 036001 (2016)]. In this work, we show a simpler alternative analysis to derive moments of the neutron energy spectrum for a plasma with variations in ion temperature. We also present a revised analysis of measured nTOF signals that uses a model with an additional degree of freedom to take into account the effect of ion temperature variations on the shape of the spectrum. Compared to presently used nTOF analysis, the revised analysis yields on average ≈2× more accurate fits to the data and up to 15% higher ion temperatures for cryogenic experiments. As a result, we quantify the ion temperature inflation caused by radially symmetric fluid flows, which are present even in a symmetric implosion, and which serve as a lower bound on the ion temperature inflation in real implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observations and Modeling of the Green Ocean Amazon: Sounding Enhancement Field Campaign Report

The goal of this campaign was to provide higher temporal sampling of the vertical structure of the atmosphere during the two intensive observational periods (IOPs) of the GoAmazon 2014/15 campaign. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s first ARM Mobile Facility (AMF1) baseline launches for 2014 and 2015 was 4 sondes/day at 2 am, 8 am, 2 pm, and 8 pm local time (LT) (6, 12, 18 and 0 Coordinated Universal Time [UTC]). However, rapid changes in boundary layer and free tropospheric temperature, humidity, and wind profiles happen throughout the diurnal cycle over Manaus, Brazil's complex forest canopy with resulting responses in aerosol, cloud, and precipitation characteristics. This campaign increased sampling to 5 sondes/day for the 2014 wet and dry season IOPs by adding a launch at 11 am (15 UTC) to capture rapid changes in boundary layer properties and convective cloud growth during that time. The extra launch also corresponded to the time of day the ARM Gulfstream (G-1) and German HALO aircraft most often flew, thus providing useful measurements of the large-scale environment during the flights. In addition, the extra launch will significantly add to the quality of AMF1 instrument retrievals and variational analysis forcing data set during the IOPs.

54 ENVIRONMENTAL SCIENCES↗

LANL-UW Collaboration on LC-QTOF Datasets (Annual Report)

Prior to the application of non-targeted chemometric techniques (i.e., Fisher ratio analysis), pre-processing steps must be carried out on the data collected using liquid chromatography-quadrupole time of flight (LC-QTOF) mass spectrometry. Data compression is the most important pre-processing step due to the vast number of high-resolution mass channels (m/z; 0.0001 Da) collected. Our first approach was to bin the mass spectral dimension to 0.01 Da; however, this approach was computationally expensive and did not preserve the high-resolution data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Planck 2015 results: IV. Low Frequency Instrument beams and window functions

This article presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30 and 44 GHz, and down to -30 dB at 70 GHz. It has been confirmed that the agreement between the simulated beams and the measured beams is better than 1% at each LFI frequency band (within the 20 dB contour from the peak, the rms values are 0.1% at 30 and 70 GHz; 0.2% at 44 GHz). Simulated polarized beams are used for the computation of the effective beam window functions. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer band shapes. The total uncertainties in the effective beam window functions are 0.7% and 1% at 30 and 44 GHz, respectively (at ℓ ≈ 600); and 0.5% at 70 GHz (at ℓ ≈ 1000).

79 ASTRONOMY AND ASTROPHYSICS↗

Navigation and Meteorological Data from Multiple Sensors on Airborne Platform (NAVMET-AIR) Value-Added Product Report

The Navigation and Meteorological Data from Multiple Sensors on Airborne Platform (NAVMET-AIR) value-added product encompasses the aafnaviwg data set in the ARM Data Center (ADC), known as the IWG file, named for the Inter-Agency Working Group for Airborne Data and Telemetry Systems (IWGADTS). Its purpose is to produce a suite of tools to promote standardization of instrument interface, data format, and data processing. This data set’s contents are navigational and meteorological state variables at 1 Hz. It also contains higher-order data flags created by ARM Aerial Facility (AAF) scientists to aid analysis such as periods when the aircraft is flying level, operating in maneuvers, or flying through cloud. Due to the nature of research flights, the payload of the aircraft consists of many duplicate and overlapping instruments to ensure, in case of instrument failure, there is a backup to record the data. Measurements from multiple instruments are consolidated into a single file. Each variable of this data set is carefully chosen from the onboard instrumentation and quality checked by AAF scientists to create this wholistic and most accurate data set for airborne research. This document is intended to be a hub towards the individual “read me” files produced for each campaign. For reference about what instrument was used for calculations on specific days, the read me files are located in the ARM IOP archive at the addresses listed, or access the IOP (intensive operational period) database at https://www.archive.arm.gov/.

54 ENVIRONMENTAL SCIENCES↗

Data acquisition and analysis of the UNCOSS underwater explosive neutron sensor

The purpose of the FP7 UNCOSS project (Underwater Coastal Sea Surveyor, http://www.uncoss-project.org) is to develop a neutron-based underwater explosive sensor to detect unexploded ordnance lying on the sea bottom. The Associated Particle Technique is used to focus the inspection on a suspicious object located by optical and electromagnetic sensors and to determine if there is an explosive charge inside. This paper presents the data acquisition electronics and data analysis software which have been developed for this project. A field programmable gate array that digitizes and processes the signal allows to perform precise time-of-flight and gamma-ray energy measurements. The gamma-ray spectra are unfolded into pure elemental count proportions, mainly C, N, O, Fe, Al, Si, and Ca. The C, N, and O count fractions are converted into chemical proportions, taking into account the gamma-ray production cross sections, as well as neutron and photon attenuation in the different shields between the ROV (Remotely Operated Vehicle) and the explosive, such as the explosive iron shell, seawater, and ROV envelop. A two-dimensional (2D) barycentric representation of the C, N, and O proportions is built from their chemical ratios, and a 2D likelihood map is built from the associated statistical and systematic uncertainties. The threat level is evaluated from the best matching materials of a database including explosives. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical analysis of the chemical attribution signatures of 3-methylfentanyl and its methods of production

Chemical attribution of the origin of an illegal drug is a key component of forensic efforts aimed at combating illicit and clandestine manufacture of drugs and pharmaceuticals. The results of these studies yield detailed information on synthesis byproducts, reagents, and precursors that can be used to identify the method of manufacture. Here in the present work, chemical attribution signatures (CAS) associated with the synthesis of the analgesic 3-methylfentanyl, N-(3-methyl-1-phenethylpiperidin-4-yl)-N-phenylpropanamide, were investigated. Eighteen crude samples from six synthesis methods were generated, the analysis of which was used to identify signatures (i.e. chemical compounds) that were important in the discrimination of synthetic route. These methods were carefully selected to minimize the use of scheduled precursors, complicated laboratory equipment, number of steps, and extreme reaction conditions. Using gas and liquid chromatographies combined with time-of-flight mass spectrometry (GC-QTOF and LC-QTOF) over 160 distinct species were monitored. Lastly, analysis of this combined data set was performed using modern machine learning techniques capable of reducing the size of the data set, prioritizing key chemical attribution signatures, and identifying the method of production for blindly synthesized 3-methylfentanyl materials.

3-methylfentanyl↗

Measurement of the Se 80 ( γ , n ) reaction with linearly polarized γ rays

This paper reports the results of the first measurements of the differential cross section of the 80 Se(γ , n) 79 Se reaction with a linearly polarized gamma-ray (γ-ray) beam. The cross section was measured at three incident γ-ray beam energies: 15.6, 15.8, and 16.0 MeV, with a beam energy spread of 3.0% full width at half-maximum (FWHM). The differential cross section for the excitation spectrum in 79Se was measured at two scattering angles in the plane of the beam polarization: θ = 90° and 135°, and at one angle in the plane perpendicular to the plane of polarization: θ = 90°. The total photoneutron cross sections determined from these data are between 0.8 and 1.3 standard deviations smaller than previously published results. Here, the excitation spectra measured in this work were fit with a Hauser-Feshbach model. Better fits to the data were obtained with a constant-temperature formulation of the nuclear level density (NLD) than with a Fermi-gas NLD model. The parameters for the constant-temperature NLD model obtained in this work are consistent with those obtained for medium-mass nuclei in previous studies.

59 ≤ A ≤ 89↗

HITMAN

HITMAN (Hermite Interpolation of Trajectories and Measurement Synthesis for Analysis of Navigators) interpolates—or estimates the unknown values between known values—flight trajectories and generates synthetic inertial measurement unit (IMU) data using Hermite splines. This Python library provides modeling and simulation capabilities to synthesize inertial measurements from discrete trajectory points, enabling researchers to create exemplar datasets for evaluating navigation algorithms in various applications, including consumer devices like smartphones and vehicles. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Walker II, Michael [Sandia National Lab. (SNL-CA),↗

Isotopic molybdenum total neutron cross section in the unresolved resonance region

Accurate isotopic molybdenum nuclear data are important because molybdenum can exist in nuclear reactor components including fuel, cladding, or as a high yield fission product. High-resolution time-of-flight neutron transmission measurements on highly enriched isotopic metallic samples of 95 Mo, 96 Mo, 98 Mo, and 100 Mo were performed in the resonance energy range from 1 to 620 keV. The measurements were taken with the newly developed modular 6 Li-glass transmission detector positioned at the 100-m experimental flight station. For the unresolved energy region (URR), new comprehensive methods of analysis were developed and validated in order to obtain accurate neutron total cross-section data from the measurement by correcting for background and transmission enhancement effects. Average parameters and fits to the total cross section for 95 Mo were obtained using the Hauser-Feshbach statistical model code FITACS, which is currently incorporated into the SAMMY code. Moreover, fits to the experimental data deviate from the current evaluated nuclear data file/B-VII.1 isotopic Mo evaluations by several percent in the URR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of small variations of speed of sound in optoacoustic tomographic imaging

Purpose: Speed of sound difference in the imaged object and surrounding coupling medium may reduce the resolution and overall quality of optoacoustic tomographic reconstructions obtained by assuming a uniform acoustic medium. In this work, the authors investigate the effects of acoustic heterogeneities and discuss potential benefits of accounting for those during the reconstruction procedure. Methods: The time shift of optoacoustic signals in an acoustically heterogeneous medium is studied theoretically by comparing different continuous and discrete wave propagation models. A modification of filtered back-projection reconstruction is subsequently implemented by considering a straight acoustic rays model for ultrasound propagation. The results obtained with this reconstruction procedure are compared numerically and experimentally to those obtained assuming a heuristically fitted uniform speed of sound in both full-view and limited-view optoacoustic tomography scenarios. Results: The theoretical analysis showcases that the errors in the time-of-flight of the signals predicted by considering the straight acoustic rays model tend to be generally small. When using this model for reconstructing simulated data, the resulting images accurately represent the theoretical ones. On the other hand, significant deviations in the location of the absorbing structures are found when using a uniform speed of sound assumption. The experimental results obtained with tissue-mimicking phantoms and a mouse postmortem are found to be consistent with the numerical simulations. Conclusions: Accurate analysis of effects of small speed of sound variations demonstrates that accounting for differences in the speed of sound allows improving optoacoustic reconstruction results in realistic imaging scenarios involving acoustic heterogeneities in tissues and surrounding media.

60 APPLIED LIFE SCIENCES↗

Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common data format (imzML) and a public data repository can contribute to more reliability and transparency of MS imaging studies.

Environmental Molecular Sciences Laboratory↗

Fast In Situ Airborne Measurement of Ammonia Using a Mid-Infrared Off-Axis ICOS Spectrometer

A new ammonia (NH 3 ) analyzer was developed based on off-axis integrated cavity output spectroscopy. Its feasibility was demonstrated by making tropospheric measurements in flights aboard the Department of Energy Gulfstream-1 aircraft. The ammonia analyzer consists of an optical cell, quantum-cascade laser, gas sampling system, control and data acquisition electronics, and analysis software. The NH 3 mixing ratio is determined from high-resolution absorption spectra obtained by tuning the laser wavelength over the NH 3 fundamental vibration band near 9.67 μm. Excellent linearity is obtained over a wide dynamic range (0–101 ppb v ) with a response rate (1/e) of 2 Hz and a precision of ±90 ppt v (1σ in 1 s). Two research flights were conducted over the Yakima Valley in Washington State. In the first flight, the ammonia analyzer was used to identify signatures of livestock from local dairy farms with high vertical and spatial resolution under low wind and calm atmospheric conditions. In the second flight, the analyzer captured livestock emission signals under windy conditions. Finally, our results demonstrate that this new ammonia spectrometer is capable of providing fast, precise, and accurate in situ observations of ammonia aboard airborne platforms to advance our understanding of atmospheric compositions and aerosol formation.

airborne↗

Parameters’ Covariance in Neutron Time of Flight Analysis – Explicit Formulae

We present here a method that estimates the parameters’ variance in a parametric model for neutron time of flight (NToF). The analytical formulae for parameter variances, obtained independently of calculation of parameter values from measured data, express the variances in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

fusion↗