Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Model America - Arizona extract from ORNL's AutoBEM v1.1

Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM).Two sets of sample data are provided for 2,555,152 buildings located within the boundary of Arizona in the United States:Data (846.3MB *.csv) - minimalist list of each building (rows) for the following fields (columns) • ID - unique building ID • Centroid - building center location in latitude/longitude (from Footprint2D) • Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) • State_abbr - state name • Area - estimate of total conditioned floor area (ft2) • Area2D - footprint area (ft2) • Height - building height (ft) • NumFloors - number of floors (above-grade) • WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) • CZ - ASHRAE Climate Zone designation • BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards • Standard - building vintage • Sample Models (114GB*.zip by county) - OpenStudio and EnergyPlus building energy models named according to IDThis data is made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL), U.S. Dept. of Energy’s (DOE) Building Technologies Office (BTO), Office of Electricity (OE), and Biological and Environmental Research (BER).

54 ENVIRONMENTAL SCIENCES↗

Model America: Data and Models for every U.S. Building

The 5-year goal of the “Model America” concept was to generate a model of every building in the United States. This data repository delivers on that goal with "Model America v1". Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,715,609 buildings detected in the United States. Of this number, 122,146,671 (97.2%) buildings resulted in a successful generation and simulation of a building energy model. This dataset includes the full 125 million buildings. Future updates may include additional buildings, data improvements, or other algorithmic model enhancements in "Model America v2". This dataset contains OSM and IDF zip files for every U.S. county. Each zip file contains the generated buildings from that county. The .csv input data contains the following data fields: 1. ID - the Unique Building Identifier (UBID), generated using the Pacific Northwest National Laboratory (PNNL) BuildingID framework 2. Centroid - building center location in latitude/longitude (from Footprint2D) 3. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 4. State_abbr - state name 5. Area - estimate of total conditioned floor area (ft2) 6. Area2D - footprint area (ft2) 7. Height - building height (ft) 8. NumFloors - number of floors (above-grade) 9. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 10. CZ - ASHRAE Climate Zone designation 11. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 12. Standard - building vintage This data is made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy’s (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). Update (September 23, 2025): We corrected the ID field in all state-level.csv input files to ensure one-to-one consistency with the corresponding .osm and .idf output files. The schema and file structure are unchanged; only the values in the ID column were modified. No files were added or removed, and the .zip bundles (containing .osm / .idf) are unchanged. The corrected .csv inputs were re-extracted in March 2025 from the original data generated ~ 2021 (Theta supercomputer runs), and published here to align input IDs with model outputs. Update (September 6, 2026): The Model America dataset was updated to replace the previous building ID field with the Unique Building Identifier (UBID), using the Pacific Northwest National Laboratory (PNNL) BuildingID framework. UBIDs provide standardized, location-based identifiers for individual building footprints and improve interoperability with other building and geospatial datasets. The data files containing the previous building identifiers were updated to include UBIDs. This update standardizes building identification; the underlying Model America building characteristics and energy simulation results were not recomputed as part of this update.

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux US-CLF Cole Farm

This is the AmeriFlux version of the carbon flux data for the site US-CLF Cole Farm. Site Description - The Cole Farm catchment (0.65km2) is located ~ 4 km southwest of the Shale Hills site, draining orthogonally to a syncline axis of the Wills Creek Formation, a calcareous shale containing interbedded siltstone, sandstone, shaly limestone, and dolomite. Even though the farm adopted no-till practices in the 1970s, the axial channel of Cole Farm flows over a thick (>2.5 m) package of sediment in the valley floor. Soils range in texture from silty clay at the ridge top to sandy loam in the valley floor. Data was collected and funded by the Critical Zone Observatory Network.

Davis, Kenneth J.↗

AmeriFlux FLUXNET-1F US-CLF Cole Farm

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-CLF Cole Farm. This is the FLUXNET version of the carbon flux data for the site US-CLF Cole Farm produced by applying the standard ONEFlux (1F) software. Site Description - The Cole Farm catchment (0.65km2) is located ~ 4 km southwest of the Shale Hills site, draining orthogonally to a syncline axis of the Wills Creek Formation, a calcareous shale containing interbedded siltstone, sandstone, shaly limestone, and dolomite. Even though the farm adopted no-till practices in the 1970s, the axial channel of Cole Farm flows over a thick (>2.5 m) package of sediment in the valley floor. Soils range in texture from silty clay at the ridge top to sandy loam in the valley floor. Data was collected and funded by the Critical Zone Observatory Network.

Davis, Kenneth J. [Department of Meteorology, Eart↗

University of Washington Harborview Research and Training Building Environmental Sample Plan for Cs-137 in Soils and Sediments

On May 2, 2019, a release of Cs-137 from a breached sealed source containing 2,800 curies (Ci) (1E14 Bq) of Cesium-137 (Cs-137) occurred at the University of Washington (UW) Harborview Research and Training Building (HRB). The release occurred during removal of the source from its holder within a portable hot cell in the second floor loading dock area. The loading dock and northeast corner of the building above the ground floor were heavily impacted by the release, while the remaining portions of the building and the exterior of the building were minimally impacted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Second ARM Mobile Facility (AMF2) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s second mobile facility (AMF2) Aerosol Observing System, designated AOS02, entered service in October of 2010 at Steamboat Springs, Colorado for the Storm Peak Laboratory Cloud Property Validation Experiment (StormVEx). The Aerosol Observing S ystem is meant to be a standalone, autonomous, aerosol sampling system. It requires only power, 208 or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s AMF3 AOS, designated AOS03, entered service in August of 2016 at the ARM Mobile Facility at Oliktok Point, Alaska. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Eastern North Atlantic (ENA) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s ENA AOS, designated AOS06, entered service in October of 2013 at the ARM Facility on Graciosa Island, Azores. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Scat Detection Dog Surveys for the San Joaquin Kit Fox on the Lawrence Livermore National Laboratory's Experimental Test Site (Site 300) and the Corral Hollow Ecological Reserve: 2020 Deployment

The San Joaquin kit fox (Vulpes macrotis mutica) historically occupied an extensive range in the San Joaquin Valley, California; however, their populations and habitat have since been significantly reduced by human impacts (United States Fish and Wildlife Service [USFWS] 1998). More than 95% of the potential habitat for kit foxes on the San Joaquin Valley floor has been converted to irrigated agriculture, urbanized, or industrialized lands. The San Joaquin kit fox was listed as endangered by the USFWS in 1967 and as threatened by the State of California in 1971. Records from local surveys, research projects, and incidental sightings indicate the present distribution of kit foxes extends from 1) southern Kern County north to Contra Costa, Alameda, and San Joaquin counties on the west side of the valley and to Stanislaus County on the east side; 2) into some of the larger, uncultivated valley-floor land parcels in Kern, Tulare, Kings, Fresno, Madera, and Merced counties; and 3) westward within 5 counties in the interior coastal range (USFWS 1998). Kit foxes have been denoted to occur in 3 geographically distinct core and several satellite populations in a heavily fragmented landscape, with the largest extant populations concentrated in the southern part of the range and smaller populations and isolated sightings in the central and northern portions (USFWS 1998, 2010).

54 ENVIRONMENTAL SCIENCES↗

A Compilation of Historical Data on Hagan Drop Testing with Results

The Hagan nuclear material storage container was designed in the late 1990’s to provide a robust container for daily use, safe transport within the plutonium facility PF-4, and storage of nuclear material for up to twenty years. There are currently >3000 loaded Hagan containers in use at TA-55. The majority of these are in the TA-55 vault, but they are also used in safes and in floor locations on the main floor of PF-4. The original design criteria are given below

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cavern Leaching Monitoring CY18 And CY19

The U.S. Strategic Petroleum Reserve (SPR) is a crude oil storage system run by the U.S. Department of Energy (DOE). The reserve consists of 60 active storage caverns spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR began executing U.S. congressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 MMB, requires raw water to be used instead of saturated brine for oil withdrawals such as for sales. All sales will produce leaching within the caverns used for oil delivery. Thirty-six caverns had a combined total of over 29 MMB of water injected from CY18-CY19 for mandatory sales. Leaching effects were monitored in these caverns to understand how the sales operations may impact the long-term integrity of the caverns. While frequent sonars are the best way to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An intermediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code (SANSMIC). The results indicate that leaching induced features are not of concern in the majority of the caverns, 32 of 36. Four caverns, BH-107, BH-108, BH-114 and WH-114 have features that may grow with additional leaching and should be monitored as leaching continues in those caverns. Six caverns had post sale sonars which were compared with SANSMIC results. SANSMIC was able to capture the leaching well. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results suggest SANSMIC is a useful tool for monitoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Strategic Petroleum Reserve Cavern Leaching Monitoring CY20

The U.S. Strategic Petroleum Reserve is a crude oil storage system run by the U.S. Department of Energy. The reserve consists of 60 active storage caverns spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR began executing U.S. congressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 MMB, requires raw water to be used instead of saturated brine for oil withdrawals such as for sales. All sales will produce leaching within the caverns used for oil delivery. Twenty-five caverns had a combined total of over 39 MMB of water injected in CY 20 as part of the Exchange for Storage program; oil was withdrawn in the same manner as for congressionally mandated sales. Leaching effects were monitored in these caverns to understand how the oil withdrawals may impact the long-term integrity of the caverns. While frequent sonars are the best way to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An intermediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code (SANSMIC) . The results indicate that leaching induced features are not of concern in the majority of the caverns, 19 of 25. Six caverns, BH-107, BH-113, BH-114, BM-4, BM-106, and WH-114 have features that may grow with additional leaching and should be monitored as leaching continues in those caverns. Ten caverns had post sale sonars that were compared with SANSMIC results. SANSMIC was able to capture the leaching well , particularly the formation of shelves and flares. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results suggest SANSMIC is a useful tool for monitoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Strategic Petroleum Reserve Cavern Leaching Monitoring CY21

Th e U.S. Strategic Petroleum Reserve (SPR) is a crude oil storage system administered by the U.S. Department of Energy. The reserve consists of 60 active storage caverns located in underground salt domes spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR started executing C ongressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 million barrels ( MMB ) , re quires that unsaturated water (referred to herein as ?raw? water) is injected into the storage caverns to displace oil for sales , exchanges, and drawdowns . As such, oil sales will produce cavern growth to the extent that raw water contacts the salt cavern walls and dissolves (leaches) the surrounding salt before reaching brine saturation. SPR injected a total of over 45 MMB of raw water into twenty - six caverns as part of oil sales in CY21 . Leaching effects were monitored in these caverns to understand how the sales operations may impact the long - term integrity of the caverns. While frequent sonars are the most direct means to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An interm ediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code , SANSMIC . The modeling results indicate that leaching - induced features do not raise co ncern for the majority of the caverns, 15 of 26. Eleven caverns, BH - 107, BH - 110, BH - 112, BH - 113, BM - 109, WH - 11, WH - 112, WH - 114, BC - 17, BC - 18, and BC - 19 have features that may grow with additional leaching and should be monitored as leaching continues in th ose caverns. Additionally, BH - 114, BM - 4, and BM - 106 were identified in previous leaching reports for recommendation of monitoring. Nine caverns had pre - and post - leach sonars that were compared with SANSMIC results. Overall, SANSMIC was able to capture the leaching well. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results validate that SANSMIC continues to serve as a useful tool for mon itoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.