Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow choking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Experiments on flow through one to four inlets of the orifice and Borda type

Choked flow rate and pressure profile data were taken on sequential axially aligned inlets of the orifice and Borda type. The configuration consisted of from two to four inlets spaced at two nominal separation distances of 0.7 and 30 diameters. At the nominal 30 diameter spacing, the reduced flow rate follows a simple empirical relation based on the reduced flow rate for a single inlet. At the nominal 0.7 diameter spacing, fluid jetting was prevalent at low temperatures and flow rates were the same as for a single inlet.

Hendricks, R. C.↗

Flow through axially aligned sequential apertures of the orifice and Borda types

Choked flow rate and pressure profile data were taken and studied for two axially aligned sequential configurations consisting of: (1) Four Borda type inlets of 1.9 1/D with two separation distances of 0.8 and 30 diameters. (2) Four orifice type inlets of 0.5 1/D with two separation distances of 0.66 and 32 diameters. A flow-coefficient reduced-temperature plot can be used to represent the flow rate data for each geometry. At the larger separation distances, the pressure profiles dropped sharply at the entrance and partially recovered within each of the Borda and orifice inlet configurations; the exception being the last inlet where at low entrance temperatures, fluid jetting could occur. For the smaller spacings fluid jetting was prevalent throughout each of the inlet configurations at lower inlet temperatures. These results are in qualitative agreement with data of tubes with single Borda or sharp-edge orifice type inlets to 105 1/D and water flow visualization studies.

Hendricks, R. C.↗

Experiments on flow through one to four inlets of the orifice and Borda type

Choked flow rate and pressure profile data were taken on sequential axially aligned inlets of the orifice and Borda type. The configuration consisted of from two to four inlets spaced at two nominal separation distances of 0.7 and 30 diameters. At the nominal 30 diameter spacing, the reduced flow rate follows a simple empirical relation based on the reduced flow rate for a single inlet. At the nominal 0.7 diameter spacing, fluid jetting was prevalent at low temperatures and flow rates were the same as for a single inlet. Previously announced in STAR as N81-30391

Hendricks, R. C.↗

Experimental performance of a 16.10-centimeter-tip-diameter sweptback centrifugal compressor designed for a 6:1 pressure ratio

A backswept impeller with design mass flow rate of 1.033 kg/sec was tested with both a vaned diffuser and a vaneless diffuser to establish stage and impeller characteristics. Design stage pressure ratio of 5.9:1 was attained at a flow slightly lower than the design value. Flow range at design speed was 6 percent of choking flow. Impeller axial tip clearance at design speed was varied to determine effect on stage and impeller performance.

Klassen, H. A.↗

Flow rates and pressure profiles for one to four axially alined Borda inlets

Choked flow rate and pressure profile data were taken on sequential, axially alined inlets of the Borda type. The configurations consisted of two to four inlets spaced 0.8 and 30 diameters apart. At a spacing of 30 diameters the reduced flow rate appeared to follow the simple empirical relation G sub r/G sub r,1=N(-b), where G sub r,1 is the reduced flow rate for a single inlet; N is the number of inlets; and b, which is weakly temperature dependent, is approximately 0.4. The relation is in reasonable agreement with an analysis of the N-inlet configuration. At a spacing of 30 diameters the pressure profiles dropped sharply at the entrance and partially recovered within each inlet somewhat independently of N. Jetting through the last Borda was common at low temperatures. At a spacing of 0.8 diameter fluid jetting was prevalent at low temperatures for each configuration studied and flow rates were the same as that for a single inlet.

Hendricks, R. C.↗

Flow rate and pressure profiles for 1 to 4 axially alined orifice inlets

Choked flow rate and pressure profile data were taken on sequential axially alined inlets of the orifice type, with an orifice length-to-diameter ratio of 0.5. The configuration consisted of two to four inlets spaced at 0.66 and 32 orifice diameters apart. At a spacing of 32 diameters the reduced flow rate appeared to follow the simple power-law relation G(sub r)/G(sub r,1) = N (sup-b), where G(sub r,1) is the reduced flow rate for a single inlet, N is the number of inlets, and b, although temperature dependent, is approximately 0.4. At this spacing the instrumented orifices and spacers gave pressure profiles that dropped sharply at the entrance and partially recovered within each inlet, somewhat independent of N. At low inlet temperature jetting through the last orifice was common. At a spacing of 0.66 diameter fluid jetting through all N inlets was prevalent at low temperatures for each configuration studied, as indicated by the flat pressure profiles and flow rates that were nearlly identical to those for a single orifice inlet. A simplifying relation was developed between the friction loss parameters for flow through N sequential tubes and N sequential inlets. The predicted flow rates for N tubes were in reasonable agreement with the N inlet analysis and followed the simple power-law relation.

Hendricks, R. C.↗

Three-dimensional shock structure in a transonic flutter cascade

Rapid double-pulse holography was employed to obtain detailed, two-dimensional images of the shock forming during simulated flutter in a transonic flowfield. The experiment comprised a linear cascade of airfoils externally oscillated in torsion and viewed tangentially at the shock surface. Three biconvex airfoils were subjected to harmonic pitching motion about the midchord axis at a frequency of 0.53 while immersed in a Mach 0.81 flow. Failure to produce observable shocks led to use of choked flow with a Mach number near one, of which 50 holograms were taken. The images revealed a narrow shock surface with a spanwise variation in the shock properties. The method is concluded to be useful for examining transonic flowfield shocks in the presence of airfoil flutter.

Boldman, D. R.↗

Depressurization and two-phase flow of water containing high levels of dissolved nitrogen gas

Depressurization of water containing various concentrations of dissolved nitrogen gas was studied. In a nonflow depressurization experiment, water with very high nitrogen content was depressurized at rates from 0.09 to 0.50 MPa per second and a metastable behavior which was a strong function of the depressurization rate was observed. Flow experiments were performed in an axisymmetric, converging diverging nozzle, a two dimensional, converging nozzle with glass sidewalls, and a sharp edge orifice. The converging diverging nozzle exhibited choked flow behavior even at nitrogen concentration levels as low as 4 percent of the saturation level. The flow rates were independent of concentration level. Flow in the two dimensional, converging, visual nozzle appeared to have a sufficient pressure drop at the throat to cause nitrogen to come out of solution, but choking occurred further downstream. The orifice flow motion pictures showed considerable oscillation downstream of the orifice and parallel to the flow. Nitrogen bubbles appeared in the flow at back pressures as high as 3.28 MPa, and the level at which bubbles were no longer visible was a function of nitrogen concentration.

Simoneau, R. J.↗

Estimating turbine limit load

A method for estimating turbine limit-load pressure ratio from turbine map information is presented and demonstrated. It is based on a mean line analysis at the last-rotor exit. The required map information includes choke flow rate at all speeds as well as pressure ratio and efficiency at the onset of choke at design speed. One- and two-stage turbines are analyzed to compare the results with those from a more rigorous off-design flow analysis and to show the sensitivities of the computed limit-load pressure ratios to changes in the key assumptions.

Glassman, Arthur J.↗

Investigation of Performance of Axial-Flow Compressor of XT-46 Turbine-Propeller Engine. II - Performance of Revised Compressor at Design Equivalent Speed: Performance of Revised Compressor at Design Equivalent Speed - II

The compressor from the XT-46 turbine-propeller engine was revised by removing the last two rows of stator blades and by eliminating the interstage leakage paths described in a previous report. With the revised compressor, the flow choking point shifted upstream into the last rotor-blade row but the maximum weight flow was not increased over that of the original compressor. The flow range of the revised compressor was reduced to about two-thirds that obtained with the original compressor. The later stages of the compressor did not produce the design static-pressure increase probably because of excessive boundary-layer build-up in this region. Measurements obtained in the ninth-stage stator showed that the performance up to this station was promising but that the last three stages of the compressor were limiting the useful operating range of the preceding stages. Some modifications in flow-passage geometry and blade settings are believed to be necessary, however, before any major improvements in over-all compressor performance can be obtained.

Creagh, John W. R.↗

A comparison of flow rates and pressure profiles for N-sequential inlets and three related seal configurations

Experimental and analytical results are presented for choked flows of fluid nitrogen over a range of reduced inlet stagnation temperatures (from 0.67 to ambient) and reduced inlet stagnation pressures to 2. Flow rate and pressure profile comparisons are made between N aligned sequential orifice inlets, a 33-tooth labyrinth seal, a 3-step seal, a cylindrical seals and the classic venturi. Seal effectiveness appears strongly dependent on upstream losses and geometry configuration.

Hendricks, R. C.↗

A comparison of flow rates and pressure profiles for N-sequential inlets and three related seal configurations

Experimental and analytical results are presented for choked flows of fluid nitrogen over a range of reduced inlet stagnation temperatures (from 0.67 to ambient) and reduced inlet stagnation pressures to 2. Flow rate and pressure profile comparisons are made between N aligned sequential orifice inlets, a 33-tooth labyrinth seal, a 3-step seal, a cylindrical seal and the classic venturi. Seal effectiveness appears strongly dependent on upstream losses and geometry configuration.

Hendricks, R. C.↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 4.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 4.1. The two most significant changes for HyRAM+ version 4.1 from HyRAM+ version 4.0 are direct incorporation of unconfined overpressure into the QRA calculations and modification of the models for cryogenic liquid flow through an orifice. In QRA mode, the user no longer needs to input peak overpressure and impulse values that were calculated separately; rather, the unconfined overpressure is estimated for the given system inputs, leak size, and occupant location. The orifice flow model now solves for the maximum mass flux through the orifice at constant entropy while conserving energy, which does not require a direct speed of sound calculation. This does not affect the mass flow for all-gaseous releases; the method results in the same speed of sound for choked flow. However, this method does result in a higher (and more realistic) mass flow rate for a given leak size for liquid releases than was previously calculated.

08 HYDROGEN↗

Development of an Experimental Data Base to Validate Compressor-Face Boundary Conditions Used in Unsteady Inlet Flow Computations

The ability to predict the dynamics of integrated inlet/compressor systems is an important part of designing high-speed propulsion systems. The boundaries of the performance envelope are often defined by undesirable transient phenomena in the inlet (unstart, buzz, etc.) in response to disturbances originated either in the engine or in the atmosphere. Stability margins used to compensate for the inability to accurately predict such processes lead to weight and performance penalties, which translate into a reduction in vehicle range. The prediction of transients in an inlet/compressor system requires either the coupling of two complex, unsteady codes (one for the inlet and one for the engine) or else a reliable characterization of the inlet/compressor interface, by specifying a boundary condition. In the context of engineering development programs, only the second option is viable economically. Computations of unsteady inlet flows invariably rely on simple compressor-face boundary conditions (CFBC's). Currently, customary conditions include choked flow, constant static pressure, constant axial velocity, constant Mach number or constant mass flow per unit area. These conditions are straightforward extensions of practices that are valid for and work well with steady inlet flows. Unfortunately, it is not at all likely that any flow property would stay constant during a complex system transient. At the start of this effort, no experimental observation existed that could be used to formulate of verify any of the CFBC'S. This lack of hard information represented a risk for a development program that has been recognized to be unacceptably large. The goal of the present effort was to generate such data. Disturbances reaching the compressor face in flight may have complex spatial structures and temporal histories. Small amplitude disturbances may be decomposed into acoustic, vorticity and entropy contributions that are uncoupled if the undisturbed flow is uniform. This study is focused on the response of an inlet/compressor system to acoustic disturbances. From the viewpoint of inlet computations, acoustic disturbances are clearly the most important, since they are the only ones capable of moving upstream. Convective and entropy disturbances may also produce upstream-moving acoustic waves, but such processes are outside the scope of the present study.

Sajben, Miklos↗

Performance of Compressor of XJ-41-V Turbojet Engine V-Performance Analysis of Compressor with Revised Vaned Collector over Range of Compressor Speeds from 3600 to 11,500 RPM

An investigation of the XJ-41-V turbojet-engine compressor with a revised vaned collector was conducted to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal compressors of this type. The original vaned collector was revised by increasing the flow area at the vaned collector entrance. A maximum adiabatic efficiency of 0.81 was obtained et a corrected weight flow of 36.5 pounds per second and a pressure ratio of 1.90. The peak pressure ratio was 3.93 and occurred at an impeller speed of 11,500 rpm at a corrected weight flow of 65.5 pounds per second. Revision of the vaned collector resulted in an increased airflow capacity over the speed range. The design air-flow capacity of 78 pounds per second was very nearly reached at the engine design speed of 11,500 rpm. The compressor air-flow choking point occurred in the vaned collector passage; however, at speeds above 8300 rpm, the air-flow capacity of the impeller was being approached as indicated by large pressure losses in the impeller at maximum air-flow conditions. An increase in compressor air-flow capacity at the higher speeds can possibly be obtained 5y removal of the flow restriction in the impeller, which would result in an increased air density at the vaned collector entrance.

Ginsburg, Ambrose↗

Thermodynamic analysis of an axial-flow laser-powered thruster

A one-dimensional model of a laser-powered thruster is analyzed. The model consists of two flow regions: a laser-heated region and a coaxial region outside the laser region. Different bulk velocities and temperatures are assigned for each region, and a common pressure is assigned for both regions. The one-dimensional inviscid flow equations are solved for each region with the same initial conditions. The results indicate that in order to prevent choked flow while increasing the anthalpy of the inlet gas by a factor of 10, the initial Mach number must be less than 0.14. For hydrogen gas seeded with 10 percent tungsten and entering the thruster tube at 10 atm and 300 K and a laser beam one-half the area of the tube, a tube length between 20 and 50 cm is required to vaporize the particles.

Kascak, A. F.↗

Critical flow and pressure ratio data for LOX flowing through nozzles

LOX and LN2 data for two-phase critical flow through nozzles were acquired with precision control. The principal measured parameters were inlet conditions, critical flow rate and critical flow pressure ratio. It is conclusively demonstrated that the principle of corresponding states can be applied to two-phase choked flow through nozzles. It is also shown that the proper normalizing parameters are developed, and that current theories can provide an adequate means for extrapolating data to other fluids.

Hendricks, R. C.↗

Critical flow and pressure ratio data for LOX flowing through nozzles

LOX and LN2 data for two-phase critical flow through nozzles have been acquired with precision control. The principal measured parameters were inlet conditions, critical flow rate and critical flow pressure ratio. The data conclusively demonstrate that the principle of corresponding states can be applied to two-phase choked flow through nozzles. These data also demonstrate that the proper normalizing parameters have been developed and current theories can provide an adequate means for extrapolating to other fluids.

Hendricks, R. C.↗