Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of a prototype flexible radiator system

The radiator is a roll-up flexible panel with the transport fluid manifolds located at the ends of the 27 foot length. A total of fifty Teflon flow tubes are sandwiched between the layers of silver wire mesh and sealed in the Teflon film. The transport fluid flows from an inlet manifold through 25 panel flow tubes to the end of the radiator panel into a manifold which directs the fluid into the other 25 flow tubes on its return to the base of the radiator. Deployment/retraction of the flexible radiator panel is by low pressure inflation tubes (one along each side of the panel) which incorporate a flat spring. The spring supplies the retraction force to wind the radiator panel on a drum when the pressure in the inflation tubes is relieved. Room ambient deployment tests of the radiator panel were conducted to verify the inflation tube spring deployment, and retraction capability. The panel underwent a thermal vacuum, solar spectrum exposure test. After approximately 100 hours of solar exposure, post-test inspection revealed no structural or optical properties degraded.

Hixon, C. W.↗

Two phase choke flow in tubes with very large L/D

Two phase and gaseous choked flow data for fluid nitrogen were obtained for a test section which was a long constant area duct of 16 200 L/D with a diverging diffuser attached to the exit. Flow rate data were taken along five isotherms (reduced temperature of 0.81, 0.96, 1.06, 1.12, and 2.34) for reduced pressures to 3. The flow rate data were mapped in the usual manner using stagnation conditions at the inlet mixing chamber upstream of the entrance length. The results are predictable by a two-phase homogeneous equilibrium choking flow model which includes wall fraction. A simplified theory which in essence decouples the long tube region from the high acceleration choking region also appears to predict the data reasonably well, but about 15 percent low.

Hendricks, R. C.↗

Evaluation of compressible-flow Preston tube calibrations

An experimental and analytical study has been made of the accuracy of various Preston tube calibration equations to determine local skin friction in two-dimensional supersonic and low-hypersonic flows. Experimental Preston tube calibration data from the present and previous studies were used to evaluate the calibration equations. The maximum value of the calibration parameters of the present data is more than an order of magnitude larger than that previously obtained; thereby, the evaluation of the various calibration equations is facilitated. The Preston tube technique was found to be very inaccurate in the low range of the calibration parameters. Above this range, there was a steady increase in accuracy with increasing values of the calibration parameters. No critical maximum tube diameter was found even with tubes about twice as large as the theoretical maximum allowable diameter. Of the two forms of the calibration equation previously existing, the logarithmic laws gave more accurate results than the power laws over an extended range of the calibration parameters in supersonic adiabatic flow.

Allen, J. M.↗

Two phase choke flow in tubes with very large L/D

Data were obtained for two phase and gaseous choked flow nitrogen in a long constant area duct of 16200 L/D with a diverging diffuser attached to the exit. Flow rate data were taken along five isotherms (reduced temperature of 0.81, 0.96, 1.06, 1.12, and 2.34) for reduced pressures to 3. The flow rate data were mapped in the usual manner using stagnation conditions at the inlet mixing chamber upstream of the entrance length. The results are predictable by a two phase homogeneous equilibrium choking flow model which includes wall friction. A simplified theory which in essence decouples the long tube region from the high acceleration choking region also appears to predict the data resonably well, but about 15 percent low.

Hendricks, R. C.↗

Parametric Study of Carbon Nanotube Production by Laser Ablation Process

Carbon nanotubes form a new class of nanomaterials that are presumed to have extraordinary mechanical, electrical and thermal properties. The single wall nanotubes (SWNTs) are estimated to be 100 times stronger than steel with 1/6th the weight; electrical carrying capacity better than copper and thermal conductivity better than diamond. Applications of these SWNTs include possible weight reduction of aerospace structures, multifunctional materials, nanosensors and nanoelectronics. Double pulsed laser vaporization process produces SWNTs with the highest percentage of nanotubes in the output material. The normal operating conditions include a green laser pulse closely followed by an infrared laser pulse. Lasers ab late a metal-containing graphite target located in a flow tube maintained in an oven at 1473K with argon flow of 100 sccm at a 500 Torr pressure. In the present work a number of production runs were carried out, changing one operating condition at a time. We have studied the effects of nine parameters, including the sequencing of the laser pulses, pulse separation times, laser energy densities, the type of buffer gas used, oven temperature, operating pressure, flow rate and inner flow tube diameters. All runs were done using the same graphite target. The collected nanotube material was characterized by a variety of analytical techniques including scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman and thermo gravimetric analysis (TGA). Results indicate trends that could be used to optimize the process and increase the efficiency of the production process.

Arepalli, Sivaram↗

Multiple transonic solutions with a new class of shock transitions in steady isothermal solar and stellar winds

It is shown that a new class of shock transitions arises in the transonic solutions of the steady isothermal solar wind equations when momentum deposition and/or nonradial flow tube divergence give rise to multiple critical points in the flow. These shock transitions between critical solutions occur for a certain range of the parameters which characterize the momentum deposition function. The isothermal wind equations allow multiple transonic solutions in the presence of such shock transitions, yielding a continuous solution passing through an inner critical point and solutions involving a shock transition between critical solutions. It is determined that these multiple transonic solutions have the same flow speed at the base but different supersonic flow speeds at infinity. It is found that the nonradial flow tube divergence and momentum addition are equivalent, which gives rise to multiple critical points and hence to multiple transonic solutions with shock transitions. In addition, the physical relevance of these properties are examined for astrophysical systems such as the inner solar wind, flows in extragalactic jets, and accretion discs.

Habbal, S. R.↗

Flexible radiator thermal vacuum test report

Two flexible, deployable/retraction radiators were designed and fabricated. The two radiator panels are distinguishable by their mission life design. One panel is designed with a 90 percent probability of withstanding the micrometeoroid environment of a low earth orbit for 30 days. This panel is designated the soft tube radiator after the PFA Teflon tubes which distribute the transport fluid over the panel. The second panel is designed with armored flow tubes to withstand the same micrometeoroid environment for 5 years. It is designated the hard tube radiator after its stainless steel flow tubes. The thermal performance of the radiators was tested under anticipated environmental conditions. The two deployment systems of the radiators were evaluated in a thermal vacuum environment.

Oren, J. A.↗

Analytical investigation of fully developed laminar flow in tubes with heat transfer with fluid properties variable along the radius

Relations were analytically obtained for the prediction of radial distributions of velocity and temperature for fully developed laminar flow of gases and of liquid metals in tubes with fluid properties variable along the radius. The relations are applicable to both heating and cooling of the fluid. By use of the relations for velocity and temperature distributions, relations were obtained among Nusselt number, friction parameter, and ratio of wall to bulk temperature. The Nusselt number and friction parameter were found to be independent of Reynolds number and Prandtl number. The effects of ratio of wall to bulk temperature on Nusselt number and friction parameter could be eliminated by evaluating the fluid properties at specified temperatures in the fluid.

Deissler, Robert G↗

Temporal and spatial adaptive algorithm for reacting flows

A numerical integration scheme for quasi-one-dimensional unsteady flows with finite-rate chemistry is developed and demonstrated. The governing Euler and species-conservation equations are derived; the integration method and the spatial and temporal grid embedding techniques are explained; and results for sample problems involving stream-tube flow with one dissociating gas, shock-tube flow with one dissociating gas, and diverging-channel flow with multiple reactions are presented in extensive graphs and briefly characterized. Accuracy comparable to that of globally fine grid solutions is obtained with significant savings in CPU time.

Pervaiz, Mehtab M.↗

The Measurement of Sulfur Oxidation Products and Their Role in Homogeneous Nucleation

An improved version of a transverse ion source was developed which uses selected ion chemical ionization mass spectrometry techniques inside of a particle nucleation flow tube. These new techniques are very unique, in that the chemical ionization is done inside of the flow tube rather than by having to remove the compounds and clusters of interest which are lost on first contact,with any surfaces. The transverse source is also unique because it allows the ion reaction time to be varied over more than an order of magnitude, which in turn makes possible the separation of ion induced cluster growth from the charging of preexisting molecular clusters. As a result of combining these unique capabilities, the first ever measurements of prenucleation molecular clusters were performed. These clusters are the intermediate stage of growth in the gas-to-particle conversion process. This new technique provides a means of observing clusters containing 2, 3, 4, ... and up to about 8 sulfuric acid molecules, where the critical cluster size under these measurement conditions was about 4 or 5. Thus, the nucleation process can now be directly observed and even growth beyond the critical cluster size can be investigated. The details of this investigation are discussed in a recently submitted paper, which is included as Appendix A. Measurements of the diffusion coefficient of sulfuric acid and sulfuric acid clustered with a water molecule have also been performed. The measurements are also discussed in more detail in another recently submitted paper which is included as Appendix B. The empirical results discussed in both of these papers provide a critical test of present nucleation theories. They also provide new hope for resolving many of the huge discrepancies between field observation and model prediction of particle nucleation. The second part of the research conducted under this project was directed towards the development of new chemical ionization techniques for measuring sulfur oxidation products.

Eisele, F. L.↗

A quiet flow Ludwieg tube for study of transition in compressible boundary layers: Design and feasibility

Since Ludwieg tubes have been around for many years, and NASA has already established the feasibility of creating quiet-flow wind tunnels, the major question addressed was the cost of the proposed facility. Cost estimates were obtained for major system components, and new designs which allowed fabrication at lower cost were developed. A large fraction of the facility cost comes from the fabrication of the highly polished quiet-flow supersonic nozzle. Methods for the design of this nozzle were studied at length in an attempt to find an effective but less expensive design. Progress was sufficient to show that a quality facility can be fabricated at a reasonable cost.

Schneider, Steven P.↗

Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

Sunada, Eric↗