At least 91 records · Page 5

Progress in ITER ECE diagnostic design and integration

The ITER electron cyclotron emission (ECE) diagnostic system has primary roles in providing measurements of the core electron temperature profile and the electron temperature fluctuation associated with the neoclassical tearing modes. The ITER ECE system includes a radial and oblique line-of-sight. Four 43-meter long low-loss transmission lines (TLs) are designed to transmit millimeter wave power in the frequency range of 70–1000 GHz in both X- and O-mode polarization from the port plug to the ECE instrumentation room in the diagnostic building. The measurement instrumentation includes two Fourier transform spectrometer (FTS) systems and two radiometer systems. The Indian Domestic Agency (IN-DA) and United States Domestic Agency share the responsibility. The IN-DA scope excluding instrumentation and control has passed its preliminary design review and is progressing towards the final design review (FDR). In parallel, the diagnostic integration in different areas is ongoing. Furthermore, several captive components for the TLs have passed FDR and will be manufactured for installation in the tokamak building soon. A peer review meeting has been held on the prototype hot calibration source, and its integration and new thermal analysis in the diagnostic shield module are continuing. A prototype TL is being tested. A prototype polarizing Martin-Puplett type FTS, operating in the frequency range 70–1000 GHz, features an in-vacuo fast scanning mechanism and a cryo-cooled dual-channel THz detector system. Its performance has been assessed in detail against ITER requirements.

47 OTHER INSTRUMENTATION↗

Design of an electron cyclotron emission diagnostics suite for COMPASS Upgrade tokamak

COMPASS Upgrade is a medium size and high field tokamak that is capable of addressing key challenges for reactor grade tokamaks, including power exhaust and advanced confinement scenarios. Electron cyclotron emission will be available among the first diagnostics to provide measurements of high spatial and temporal resolution of electron temperature profiles and electron temperature fluctuation profiles through a radial view. A separate oblique view at 12° from normal will be utilized to study non-thermal electrons. Both the radial and oblique views are envisioned to be located in a wide-angle midplane port, which has dimensions that enable simultaneous hosting of the front-end of their quasi-optical (QO) designs. Each QO design will have an in situ hot calibration source in the front-end to provide standalone and calibrated Te (R,t) measurements. The conceptual design for each QO system, the Gaussian beam analysis, and the details of the diagnostic channels are presented.

Instruments & Instrumentation↗

Diagnostics for Linac Optimization With Machine Learning

The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To counter fluctuations of Linac output due to various effects to be described below we are working on implementing dynamic longitudinal parameter optimization based on Machine Learning (ML). As inputs for the ML model, signals from beam diagnostics have to be well understood and reliable. In this paper we discuss the status and plans for ML-based optimization as well as preliminary results of diagnostics studies.

43 PARTICLE ACCELERATORS↗

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison between mirror Langmuir probe and gas-puff imaging measurements of intermittent fluctuations in the Alcator C-Mod scrape-off layer

Statistical properties of the scrape-off layer plasma fluctuations are studied in ohmically heated plasmas in the Alcator C-Mod tokamak. For the first time, plasma fluctuations as well as parameters that describe the fluctuations are compared across measurements from a mirror Langmuir probe (MLP) and from gas-puff imaging (GPI) that sample the same plasma discharge. This comparison is complemented by an analysis of line emission time-series data, synthesized from the MLP electron density and temperature measurements. The fluctuations observed by the MLP and GPI typically display relative fluctuation amplitudes of order unity together with positively skewed and flattened probability density functions. Such data time series are well described by an established stochastic framework that models the data as a superposition of uncorrelated, two-sided exponential pulses. The most important parameter of the process is the intermittency parameter, $γ=τ_d/τ_w$, where τd denotes the duration time of a single pulse and $τ_w$ gives the average waiting time between consecutive pulses. In this study we show, using a new deconvolution method, that these parameters can be consistently estimated from different statistics of the data. We also show that the statistical properties of the data sampled by the MLP and GPI diagnostic are very similar. Finally, a synthetic GPI signal using only plasma parameters sampled by the MLP shows qualitatively different fluctuation statistics from the measured GPI signal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Technical Report for the SciDAC Center for the Study of Plasma Microturbulence

This final technical report for the SciDAC Center for the Study of Plasma Microturbulence documents contributions from MIT to the project over the period of the award (February 15, 2011 to February 14, 2020). This project focused on the development of neoclassical and gyrokinetic simulation capabilities relevant for the description of particle, momentum and energy transport in tokamak fusion plasmas. Extensive validation against experimental results from Alcator C-Mod and DIII-D experiments was performed. Overall areas of emphasis included gyrokinetic simulations, experiments, and observation of density gradient driven Trapped Electron Mode (TEM) turbulence relevant to burning plasmas; theory and gyrokinetic simulations of the parametric variation of the nonlinear upshift of the TEM critical density gradient; identification of a new mechanism for the isotope effect due to density gradient driven TEM turbulence; new synthetic diagnostics based on full-wave simulations which enabled unprecedented agreement between gyrokinetic simulations and measured fluctuation spectra with and without strong electron heating; development of new continuum pedestal neoclassical and turbulence codes; formulation and implementation of the first gyrokinetic exact Fokker-Planck collision operator in gyrokinetic turbulence simulations; development of new spectral approaches in velocity space for highly efficient treatments of collisions; new model collision operators implemented in the discontinuous Galerkin gyrokinetic edge turbulence code GKEYLL; and a new model and spectral code to study the interaction of ion- and electron-scale turbulence, which will serve as an efficient test-bed for multi-rate and multi-scale methods. These fundamental advances contribute to the development of a validated, predictive capability for turbulent and collisional particle, momentum and energy transport in both the core and edge of magnetically confined fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak

The optics system of the Electron Cyclotron Emission Imaging (ECEI) diagnostics on the DIII-D tokamak has been developed and installed for high-resolution temperature fluctuations measurement in the previous decade. The System-on-Chip approach upgrade was finished in June 2019 with high integrated receiver array with 20 individual modules. In this paper, we design new optics with high-level integration. In the new optics system, there will be two mirrors from plasma to receiver array, including one replaceable curved mirror out of the vacuum and one fixed curved mirror in the vessel. There are two options with 1:1 and 1:2 magnifications for high poloidal resolution and larger poloidal window modes. Overall, the new optics system has multiple improvements, including lighter weight, smaller size, more flexible installation and alignment. The synthetic ECEI module is used to evaluate the new optics system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discerning the thermodynamic feasibility of the spontaneous coexistence of multiple functional vegetation groups

Can the Second Law of Thermodynamics explain why ecosystems naturally organize into a complex structure composed of multiple vegetation species and functional groups? Ecosystem structure, which refers to the number and type of plant functional groups, is the result of self-organization, or the spontaneous emergence of order from random fluctuations. By considering ecosystems as open thermodynamic systems, we model and study these fluctuations of throughput signatures on short timescales to determine the drivers and characteristics of ecosystem structure. This diagnostic approach allows us to use fluxes of energy and entropy to calculate an ecosystem’s estimated work and understand the thermodynamic behavior of the system. We use a multi-layer canopy-root-soil model to calculate the energy and entropy fluxes of different scenarios for field sites across various climates. At each site, scenarios comprised of native individual plant functional groups and a coexisting multi-group composition scenario including all functional groups observed at the site are compared. Ecosystem-scale calculations demonstrate that entropy fluxes and work efficiency—the work performed for the amount of radiation entering the ecosystem—are greatest in the multi-group scenario when its leaf area is significantly larger than each of its individual functional groups. Thus, we conclude that ecosystems self-organize towards the vegetation structure with the greatest outgoing entropy flux and work efficiency, resulting in the coexistence of multiple functional groups and performing the maximum amount of work within the constraints of locally available energy, water, and nutrients.

54 ENVIRONMENTAL SCIENCES↗

Study of the connected four-point correlation function of galaxies from the DESI Data Release 1 luminous red galaxy sample

We present a measurement of the non-Gaussian four-point correlation function (4PCF) from the DESI DR1 luminous red galaxy (LRG) sample. For the gravitationally induced parity-even 4PCF, we detect a signal with a significance of 14.7⁢𝜎 using our fiducial setup. We assess the robustness of this detection through a series of validation tests, including auto and cross-correlation analyses, sky partitioning across multiple patch combinations, and variations in radial scale cuts. Due to the low completeness of the sample, we find that differences in fiber assignment implementation schemes can significantly impact estimation of the covariance and introduce biases in the data vector. After correcting for these effects, all tests yield consistent results. This is one of the first measurements of the connected 4PCF on the DESI LRG sample; the good agreement between the simulation and the data implies that the amplitude of the density fluctuation inferred from the connected 4PCF is consistent with the Planck Λ⁢ CDM cosmology. The methodology and diagnostic framework established in this work provide a foundation for interpreting parity-odd 4PCF.

Cosmology↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Model

The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.

Fang, J. [Princeton Plasma Physics Laboratory (PPP↗

Analysis of runaway electron driven whistler wave instability experiments

Data acquired on the DIII-D tokamak were analyzed. The data are from experiments that were conducted to study an instability that is driven unstable by intense populations of electrons with MeV energies that are known as runaway electrons. The instability is a type of plasma wave called a whistler wave that occurs at frequencies above the ion cyclotron frequency but well below the electron cyclotron frequency. The waves were measured by magnetic fluctuation coils that are embedded in the DIII-D vacuum vessel wall. After upgrades to this diagnostic were completed, new experiments were conducted on July 13, 2020 in order to measure the toroidal mode number of the whistler waves and to extend the frequency of the detected waves. Through the use of mixers, instability between 600-700 MHz was detected. (The initial experiments only measured up to 200 MHz.) Analysis of the data was led by Hari Choudhury, a PhD student at Columbia University. Mr. Choudhury has submitted two papers for publication that include contributions by UC Irvine (UCI) Professor Heidbrink and his graduated PhD student Genevieve DeGrandchamp: “Detailed Characterization of Runaway Electron Driven Whistler Waves in Low-Density DIII-D Discharges” and “First Demonstration of Resonant Pitch-Angle Scattering of Relativistic Electrons by Externally-Launched Helicon Waves.” The first paper, which has been submitted to Physics of Plasmas, has significant contributions to both the data and the interpretation by UCI scientists. In contrast, UCI contributions to the second paper, which has been submitted to Physical Review Letters, are relatively minor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in physics and applications of 3D magnetic perturbations on the J-TEXT tokamak

In the last two years, three major technical improvements have been made on J-TEXT in supporting of the expanded operation regions and diagnostic capabilities. (1) The successful commission of the 105 GHz/500 kW/1 s electron cyclotron resonance heating (ECRH) system increasing the core electron temperature from 0.9 keV up to around 1.5 keV. (2) The poloidal divertor configuration with an X-point in the high-field side has been achieved. In particular, the 400 kW electron cyclotron wave has also been successfully injected into the diverted plasma. (3) A 256-channel electron cyclotron emission imaging diagnostic system and two sets of four-channel Doppler backscattering diagnostics have been successfully developed on J-TEXT, allowing detailed measurement of the electron temperature and density fluctuations for turbulence and MHD research. The locked mode (LM), especially the 2/1 LM, is one of the biggest threats to the plasma operation. Both the thresholds of 2/1 and 3/1 LM are observed to vary non-monotonically on electron density. The electrode biasing was applied successfully to unlock the LM from either a rotating or static resonant magnetic perturbation (RMP) field. In the presence of 2/1 LM, three kinds of standing wave (SW) structures have been observed to share a similar connection to the island structure, i.e. the nodes of the SWs locate around the O- or X-points of the 2/1 island. The control and mitigation of disruption is essential to the safe operation of ITER, and it has been systematically studied by applying a RMP field, massive gas injection (MGI) and shattered pellet injection on J-TEXT. When the RMP-induced 2/1 LM is larger than a critical width, the MGI shutdown process can be significantly influenced. If the phase difference between the O-point of LM and the MGI valve is +90° (or –90°), the penetration depth and the assimilation of impurities can be enhanced (or suppressed) during the pre-thermal quench (TQ) phase and result in a faster (or slower) TQ. A secondary MGI can also suppress the runaway electron (RE) generation, if the additional high-Z impurity gas arrives at the plasma edge before TQ. When the secondary MGI has been applied after the formation of the RE current plateau, the RE current can be dissipated, and the dissipation rate increases with the injected impurity quantity but saturates with a maximum of 28 MA s –1 . The non-local transport is experimentally observed in the ion transport channel. The electron thermal diffusivity significantly increases with the ECRH power. Theoretical work shows that significant intrinsic current can be driven by electromagnetic turbulence, and the robust formation mechanism of the E × B staircase is identified from the Hasegawa–Wakatani system.

divertor↗

Emulation of quantum correlations by classical dynamics in a spin-$\frac{1}{2}$ Heisenberg chain

We simulate the dynamical spin structure factor (DSSF) 𝒮⁡(𝑞,𝜔) of the spin-1/2 Heisenberg antiferromagnetic chain using classical simulations. By employing Landau-Lifshitz Dynamics, we emulate quantum correlations through temperature-dependent corrections, including rescaling of magnetic dipoles and renormalization of exchange interactions. Here, our results closely match Quantum Monte-Carlo calculations for 𝑘 B⁢ 𝑇/𝐽≳1, extending the applicability of classical dynamics to the challenging case of gapless excitations. At higher temperatures, our simulations comply with general predictions for uncorrelated paramagnetic fluctuations in the infinite temperature limit. Entanglement witnesses derived from the quantum-equivalent DSSF act as sensitive diagnostics for the quantum-to-classical crossover. Their reliability stems from their dependence on spectral features alone, enabling classical dynamics to emulate quantum thresholds without genuine entanglement. This framework also reproduces transverse spin correlations in finite magnetic fields, in agreement with quantum simulations. Together, our results establish quantum-corrected classical dynamics as a scalable and predictive tool for interpreting scattering experiments and exploring quantum correlations in strongly correlated spin systems.

Inelastic neutron scattering↗

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗

Heavy ion beam probe for Wendelstein 7-X measurement capabilities as projected through its design

A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.

Instruments & Instrumentation↗

Validation of gyrokinetic simulations in NSTX and projections for high-k turbulence measurements in NSTX-U

An extensive validation effort performed for a modest-beta NSTX NBI-heated H-mode discharge predicts that electron thermal transport can be entirely explained by electron-scale turbulence fluctuations driven by the electron temperature gradient mode (ETG), both in conditions of strong and weak ETG turbulence drive. Thermal power-balance estimates computed by TRANSP as well as the shape of the high-k density fluctuation wavenumber spectrum and the fluctuation level ratio between strongly driven and weakly driven ETG-turbulence conditions can be matched by nonlinear gyrokinetic simulations and a synthetic diagnostic for high-k scattering. Linear gyrokinetic simulations suggest that the ion-scale instability in the weak ETG condition is close to the critical threshold for the kinetic ballooning mode instability, and nonlinear ion-scale gyrokinetic simulations show that turbulence might be in a state reminiscent of a Dimits' shift regime, opening speculation on the role that ion-scale turbulence might play for the weak ETG condition. A simulation that matched all experimental constraints is chosen to project high-k turbulence spectra in NSTX-U, revealing that the new high-k system [R. Barchfeld et al., Rev. Sci. Instrum. 89, 10C114 (2018)] should be sensitive to density fluctuations from radially elongated streamer structures. In this study, two schemes are designed to characterize the radial and poloidal wavenumber dependence of the density fluctuation wavenumber power spectrum around the streamer peak, suggesting future high-k fluctuation measurements could be sensitive to an asymmetry in the k r spectrum introduced due to the presence of strong background flow shear.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D

A recent upgrade to the Imaging Neutral Particle Analyzer (INPA) on DIII-D has allowed for the first fluctuation measurements using an INPA to be taken during a neoclassical tearing mode (NTM). The INPA signal tracked the mode over 150 ms as the mode frequency dropped to zero, capturing both the NTM with poloidal and toroidal mode numbers $m/n=2/1$ and a $3/2$ mode at double the frequency. Analysis shows that the signals originate from charge exchange events near the edge of the plasma, and relative fluctuation amplitudes are greater than 25% for the duration of the NTM. Filtered signals show frequency beating patterns that are phase-space dependent. Simulated signal is dominated by prompt transport from the neutral beams to the INPA sightline, while the contribution from the slowing down distribution is significantly lower. Simulated measurements in the range of pitches that the diagnostic is sensitive to (0.5≤|v∥/v|≤ 0.75) show the signal is dominated by trapped orbits that pass through magnetic islands near the edge of the plasma. Calculations of expected fluctuation levels show that only direct interaction with the NTM can provide the strong relative fluctuation levels seen experimentally. The prompt nature of the orbits and thin radial layer found to contribute to synthetic signals suggest INPA passive data may be used to measure the perturbations of confined orbits on a single pass through a plasma instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗