Search NASASearch

SEARCH · Search NASA

Results for “fluid flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

System for measuring Reynolds in a turbulently flowing fluid

A system for measuring momentum flux in a turbulently flowing fluid includes: a sensing apparatus for dynamically sensing the mainstream and the cross velocity components of the fluid, a transducer operative to provide two electrical output signals representative of the velocity components in the mainstream and in the cross direction, and signal processors to derive the Reynolds stress wave and the Reynolds stress.

Cheng, D. Y.

Method and Apparatus for Measuring Fluid Flow

Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.

Arndt, G. Dickey

Eocene-Oligocene Metamorphism, Fluid Flow and Deformation in the Ruby Mountains-East Humboldt Range Metamorphic Core Complex

Metamorphic core complexes are ubiquitous in collapsed orogens globally and play a primary role in crustal exhumation. Here, we investigate the metamorphic history of the Ruby Mountains-East Humboldt Range metamorphic core complex, Nevada, using petrochronology to understand how magmatism, metamorphism and deformation interact to modulate crustal rheology, and the timing of exhumation within the Sevier orogenic belt. Field study, microstructural analysis, thermobarometry and laser ablation split-stream monazite, titanite and allanite petrochronology of the mylonitic footwall were integrated to elucidate the pressure-temperature-time (P-T-t) evolution. Major-, trace-element and quartz-in-garnet thermobarometry show peak metamorphism occurred at 5.5–6 kbar and 600–650°C across the study area. Monazite and titanite U-(Th)-Pb petrochronology constrain this episode of metamorphism to 88–81 Ma with the structurally deepest samples yielding dates down to ca. 71 Ma. The preservation of peak metamorphic mineral assemblages indicates these rocks remained at near-peak temperature conditions into the Cenozoic. Cenozoic metamorphism occurred during a punctuated episode contemporaneous with the Great Basin ignimbrite flare up. All samples show a distinct 39–37 Ma population of monazite, titanite and allanite dates that correlate with the emplacement of quartz diorite and gabbro intrusions throughout the footwall. Accessory phases contain zoning textures in backscattered electron images that are consistent with fluid-mediated dissolution-reprecipitation reactions. The U-(Th)-Pb analyses from these zones yield 39–27 Ma dates interpreted as the timing of fluid flow. The results of this study elucidate the integrated importance of magmatism, melting and fluid flow in driving the coupled evolution of Late Cretaceous metamorphism within the Sevier hinterland and the subsequent Cenozoic metamorphic core complex development that exhumed the middle crust.

58 GEOSCIENCES

Simple models of fluid flow at the core surface derived from geomagnetic field models

The fluid flow at the core surface is determined for a given model of temporal magnetic field variation, assuming steady flow and adopting the frozen-flux approximation. Evidence is presented for ageostrophic flow in the form of flow across the geographical equator. A simple pattern of the large-scale toroidal part of the flow is found. The pattern is nearly symmetric about the equator. Changes in the flow pattern are obtained from flow maps covering 5-year intervals beginning in 1915.

Bloxham, Jeremy

Simulation of Fluid Flow and Collection Efficiency at Low Stokes Number

Numerical simulations of fluid flow and collection efficiency for a Science Engineering Associates (SEA) Robust probe are presented. The cases cover a range of freestream velocity from 10-135 m/s, and particle sizes from 1-200 µm. This combination produces results for Stokes numbers in the range of 0.07-1092. A blended modified Stokes (defined in the paper) is introduced which covers a range of 0.07-146. Of particular interest is the collection efficiency of the sensing element (a forward-facing half-pipe), Etot, in the low Stokes number regime. It was observed that the collection efficiency of the sensing area approached one for large Stokes numbers (>100) as expected. As blended modified Stokes number approached one, the Etot dropped to approximately 0.5. By blended modified Stokes numbers of 0.3, the Etot has dropped to essentially zero. Plotting collection versus blended modified Stokes number, the different freestream velocities collapsed quite well on to a single curve. The paper presents a discussion on the flowfield and local collection efficiency, beta, in an effort to explain the predictions. Of particular interest is what is essentially a shadow zone in plain sight. As the Stokes number is reduced, the local beta along the centerline of the half-pipe goes to zero. This occurs at Stokes numbers where the overall collection, Etot, is still appreciable. An empirical relation was developed to allow for corrected collection values at low Stokes numbers. The correlation remains within 2% for blended modified Stokes numbers above 1, and within 6% for all cases.

Instrumentation

Simulation of Fluid Flow and Collection Efficiency at Low Stokes Number

Numerical simulations of fluid flow and collection efficiency for a Science Engineering Associates (SEA) Robust probe are presented. The cases cover a range of freestream velocity from 10-135 m/s, and particle sizes from 1-200 µm. This combination produces results for Stokes numbers in the range of 0.07-1092. A blended modified Stokes (defined in the paper) is introduced which covers a range of 0.07-146. Of particular interest is the collection efficiency of the sensing element (a forward-facing half-pipe), Etot, in the low Stokes number regime. It was observed that the collection efficiency of the sensing area approached one for large Stokes numbers (>100) as expected. As blended modified Stokes number approached one, the Etot dropped to approximately 0.5. By blended modified Stokes numbers of 0.3, the Etot has dropped to essentially zero. Plotting collection versus blended modified Stokes number, the different freestream velocities collapsed quite well on to a single curve. The paper presents a discussion on the flowfield and local collection efficiency, beta, in an effort to explain the predictions. Of particular interest is what is essentially a shadow zone in plain sight. As the Stokes number is reduced, the local beta along the centerline of the half-pipe goes to zero. This occurs at Stokes numbers where the overall collection, Etot, is still appreciable. An empirical relation was developed to allow for corrected collection values at low Stokes numbers. The correlation remains within 2% for blended modified Stokes numbers above 1, and within 6% for all cases.

Instrumentation

Osteoblasts respond to pulsatile fluid flow with short-term increases in PGE(2) but no change in mineralization

Although there is no consensus as to the precise nature of the mechanostimulatory signals imparted to the bone cells during remodeling, it has been postulated that deformation-induced fluid flow plays a role in the mechanotransduction pathway. In vitro, osteoblasts respond to fluid shear stress with an increase in PGE(2) production; however, the long-term effects of fluid shear stress on cell proliferation and differentiation have not been examined. The goal of this study was to apply continuous pulsatile fluid shear stresses to osteoblasts and determine whether the initial production of PGE(2) is associated with long-term biochemical changes. The acute response of bone cells to a pulsatile fluid shear stress (0.6 +/- 0.5 Pa, 3.0 Hz) was characterized by a transient fourfold increase in PGE(2) production. After 7 days of static culture (0 dyn/cm(2)) or low (0.06 +/- 0.05 Pa, 0.3 Hz) or high (0.6 +/- 0.5 Pa, 3.0 Hz) levels of pulsatile fluid shear stress, the bone cells responded with an 83% average increase in cell number, but no statistical difference (P > 0.53) between the groups was observed. Alkaline phosphatase activity per cell decreased in the static cultures but not in the low- or high-flow groups. Mineralization was also unaffected by the different levels of applied shear stress. Our results indicate that short-term changes in PGE(2) levels caused by pulsatile fluid flow are not associated with long-term changes in proliferation or mineralization of bone cells.

NASA Discipline Musculoskeletal

Transient heat and fluid flow in porous annuli

An analysis of the transient behavior of heat and fluid flow in porous annuli is reported. The problem analyzed has relevance to the design of adsorption compressors. Consideration is given to filling a porous annulus with a fluid while cooling is applied. The governing equations for the transport process considered have been solved numerically using a finite-difference method. A parametric study has been conducted to reveal the influence of the different parameters. The conditions for maximizing the mass intake are identified.

Sathe, S. B.

Electromagnetic probe technique for fluid flow measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constant of the fluid is possible, several or even many fluids can be measured in the same flow stream. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans to solve this problem will be discussed herein.

Arndt, G. D.

Electromagnetic Probe Technique for Fluid Flow Measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constants of each fluid is possible, several or even many fluids can be measured in the same flow steam. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this industry, a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans and program to solve this problem will be discussed herein.

Arndt, G. D.

Low-gravity fluid flows

The behavior of fluids in micro-gravity conditions is examined, with particular regard to applications in the growth of single crystals. The effects of gravity on fluid behavior are reviewed, and the advent of Shuttle flights are noted to offer extended time for experimentation and processing in a null-gravity environment, with accelerations resulting solely from maneuvering rockets. Buoyancy driven flows are considered for the cases stable-, unstable-, and mixed-mode convection. Further discussion is presented on g-jitter, surface-tension gradient, thermoacoustic, and phase-change convection. All the flows are present in both gravity and null gravity conditions, although the effects of buoyancy and g-jitter convection usually overshadow the other effects while in a gravity field. Further work is recommended on critical-state and sedimentation processes in microgravity conditions.

Ostrach, S.

Fluid flow volume measurements using a capacitance/conductance probe system

A probe system has been developed to measure the flow volume of a single fluid passing through an orifice or flow line. The system employs both capacitance and a conductance probe at the orifice, together with phase detection and data acquisition circuitry to measure flow volume and salinity under low or zero gravity conditions. A wide variety of frequencies can be used for the radio frequency (RF) signal source which is chosen primarily by the capacitance of the orifice probe and the fluid passing through the orifice. Rapid measurements are made using the reflected signal from the orifice probe to determine the 'instantaneous' permittivity of the fluid/gas mixture passing through. The 'instantaneous' measurements are integrated over time to determine flow volume. Analysis reveals that a narrow orifice helps to reduce non-linearities caused by differing flow rates. The geometry of 'deflectors' and 'directors' for the flowing fluid are important in obtaining linearity. Measured data shows that a volume measurement accuracy of approximately four percent can be consistently achieved. The prototype hardware system and associated software have been optimized and are available for further applications. The system has immediate application in low or zero gravity environments for measurements of urine or other liquid volumes.

Nguyen, T. X.