Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluid systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Transient thermal analysis of fluid systems

Computer program performs transient thermal analysis of any 2-node to 200-node-thermal network, which transports heat by fluid flow convection. Program can be modified to add conduction along tubes and radiation.

Chandler, G. D.↗

Fluid system design for a superfluid helium space tanker

The design of a superfluid helium space tanker is described, which has the characteristics of minimum boil-off, low-g venting and maintenance of the superfluid state, transfer operations that include a pumping method, the additional fluid conditioning required during transfer, and a liquid acquisition system for transfer in a weightless environment. A concept for loading and ground conditioning of He, that simplifies launch operations and maximizes the quantity available at launch is presented. Configuration diagrams are included.

Gille, John P.↗

Computer simulation of thermal and fluid systems for MIUS integration and subsystems test /MIST/ laboratory

This paper describes the application of the SINDA (systems improved numerical differencing analyzer) computer program to simulate the operation of the NASA/JSC MIUS integration and subsystems test (MIST) laboratory. The MIST laboratory is designed to test the integration capability of the following subsystems of a modular integrated utility system (MIUS): (1) electric power generation, (2) space heating and cooling, (3) solid waste disposal, (4) potable water supply, and (5) waste water treatment. The SINDA/MIST computer model is designed to simulate the response of these subsystems to externally impressed loads. The computer model determines the amount of recovered waste heat from the prime mover exhaust, water jacket and oil/aftercooler and from the incinerator. This recovered waste heat is used in the model to heat potable water, for space heating, absorption air conditioning, waste water sterilization, and to provide for thermal storage. The details of the thermal and fluid simulation of MIST including the system configuration, modes of operation modeled, SINDA model characteristics and the results of several analyses are described.

Rochelle, W. C.↗

A Cryogenic Fluid System Simulation in Support of Integrated Systems Health Management

Simulations serve as important tools throughout the design and operation of engineering systems. In the context of sys-tems health management, simulations serve many uses. For one, the underlying physical models can be used by model-based health management tools to develop diagnostic and prognostic models. These simulations should incorporate both nominal and faulty behavior with the ability to inject various faults into the system. Such simulations can there-fore be used for operator training, for both nominal and faulty situations, as well as for developing and prototyping health management algorithms. In this paper, we describe a methodology for building such simulations. We discuss the design decisions and tools used to build a simulation of a cryogenic fluid test bed, and how it serves as a core technology for systems health management development and maturation.

cryogenics↗

Balanced Flow Metering and Conditioning: Technology for Fluid Systems

Revolutionary new technology that creates balanced conditions across the face of a multi-hole orifice plate has been developed, patented and exclusively licensed for commercialization. This balanced flow technology simultaneously measures mass flow rate, volumetric flow rate, and fluid density with little or no straight pipe run requirements. Initially, the balanced plate was a drop in replacement for a traditional orifice plate, but testing revealed substantially better performance as compared to the orifice plate such as, 10 times better accuracy, 2 times faster (shorter distance) pressure recovery, 15 times less acoustic noise energy generation, and 2.5 times less permanent pressure loss. During 2004 testing at MSFC, testing revealed several configurations of the balanced flow meter that match the accuracy of Venturi meters while having only slightly more permanent pressure loss. However, the balanced meter only requires a 0.25 inch plate and has no upstream or downstream straight pipe requirements. As a fluid conditioning device, the fluid usually reaches fully developed flow within 1 pipe diameter of the balanced conditioning plate. This paper will describe the basic balanced flow metering technology, provide performance details generated by testing to date and provide implementation details along with calculations required for differing degrees of flow metering accuracy.

Kelley, Anthony R.↗

Advanced Physics-Based Fluid System Performance Monitoring to Support Nuclear Power Plant Operations. Final CRADA report

This project targeted performance monitoring requirements for nuclear power plants with the goal of improving plant economics. We introduced a new and innovative technology to the industry that can reduce operations staffing levels by automating surveillance and can reduce maintenance staffing levels by providing early detection of degrading equipment. A beta-stage release of the PRO-AID power plant equipment fault diagnostic software ready for deployment in nuclear power plants will be delivered and demonstrated in a utility pilot project. To provide for efficient use of DOE funds the aim is to generate a minimum viable product for which we can prove the value of the product. The end state product will be serviceable for use in either a simulator environment or plant environment. The former provides a means for demonstration of the diagnostic capability for faults unlikely to be encountered in day-to-day operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study to develop improved methods to detect leakage in fluid systems, phase 2

An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.

Janus, J. C.↗

Study to develop improved methods to detect leakage in fluid systems, phase 3

Research was undertaken to design and fabricate a prototype flight weight ultrasonic contact sensor leak detection system and to perform the necessary testing to collect enough data to establish design parameters and develop necessary baseline operating characteristics. The prototype system consists of five channels and is capable for monitoring frequencies from 1 KHz to 110 KHz.

Janus, J. C.↗

Zero Gravity Facility for space vehicle fluid systems research.

Review of the major features and characteristics of the 5- to 10-second Zero Gravity Facility of the NASA Lewis Research Center. The facility consists primarily of a vertical (155 m) vacuum chamber wherein a variety of free-fall (weightless) experiments can be performed.-

Petrash, D. A.↗

Ageostrophic instabilities in a two fluid system with rotation

The stability of synoptic scale waves formed on a frontal surface is studied including nongeostrophic effects with the basic flow subjected to both vertical and horizontal shear. Spectral method is used to obtain the desired solutions. The stability characteristics of the developed unstable modes are presented as a function of shears of the basic flow. With the inclusion of barotropic shear the spectrum of instabilities increase. The lower speeded member of the mixed mode (gravitational-rotational) pair is influenced by the barotropic shear in the basic current and it appears at lower vertical shears. The structure of the height perturbations are utilized to distinguish the various unstable modes developed in the system together with their stability characteristics. This investigation has shown that the ageostrophic effects can be a significant factor in the development of synoptic scale waves on a frontal surface.

Ramanathan, N.↗

Convection in a two-layer fluid system

Experimental results are presented, and preliminary computations are performed on a system of two immiscible liquid layers with a temperature gradient applied parallel to the interface. The experiments reflect the combined contribution of buoyancy and surface-tension-induced (Marangoni) convection. It is concluded that buoyancy effects appear to be dominant and mask any surface-tension-induced convection present. Numerical computations show significant modification of pure buoyant convection by surface-tension gradients. The results are of interest in connection with the liquid encapsulation of GaAs melts in a microgravity environment.

Prakash, A.↗

Slosh wave excitation and stability of spacecraft fluid systems

The instability of liquid and gas interface can be induced by the pressure of longitudinal and lateral accelerations, vehicle vibration, and rotational fields of spacecraft in a microgravity environment. Characteristics of slosh waves excited by the restoring force field of gravity jitters have been investigated. Results show that lower frequency gravity jitters excite slosh waves with higher ratio of maximum amplitude to wave length than that of the slosh waves generated by the higher frequency gravity jitters.

Hung, R. J.↗