Search NASA⌕ Search

SEARCH · Search NASA

Results for “force vector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fault Tolerant Magnetic Bearing for Turbomachinery

NASA Glenn Research Center (GRC) has developed a Fault-Tolerant Magnetic Bearing Suspension rig to enhance the bearing system safety. It successfully demonstrated that using only two active poles out of eight redundant poles from each radial bearing (that is, simply 12 out of 16 poles dead) levitated the rotor and spun it without losing stability and desired position up to the maximum allowable speed of 20,000 rpm. In this paper, it is demonstrated that as far as the summation of force vectors of the attracting poles and rotor weight is zero, a fault-tolerant magnetic bearing system maintained the rotor at the desired position without losing stability even at the maximum rotor speed. A proportional-integral-derivative (PID) controller generated autonomous corrective actions with no operator's input for the fault situations without losing load capacity in terms of rotor position. This paper also deals with a centralized modal controller to better control the dynamic behavior over system modes.

Choi, Benjamin↗

Ground Reaction Force and Mechanical Differences Between the Interim Resistive Exercise Device (iRED) and Smith Machine While Performing a Squat

Musculoskeletal unloading in microgravity has been shown to induce losses in bone mineral density, muscle cross-sectional area, and muscle strength. Currently, an Interim Resistive Exercise Device (iRED) is being flown on board the ISS to help counteract these losses. Free weight training has shown successful positive musculoskeletal adaptations. In biomechanical research, ground reaction forces (GRF) trajectories are used to define differences between exercise devices. The purpose of this evaluation is to quantify the differences in GRF between the iRED and free weight exercise performed on a Smith machine during a squat. Due to the differences in resistance properties, inertial loading and load application to the body between the two devices, we hypothesize that subjects using iRED will produce GRF that are significantly different from the Smith machine. There will be differences in bar/harness range of motion and the time when peak GRF occurred in the ROMbar. Three male subjects performed three sets of ten squats on the iRED and on the Smith Machine on two separate days at a 2-second cadence. Statistically significant differences were found between the two devices in all measured GRF variables. Average Fz and Fx during the Smith machine squat were significantly higher than iRED. Average Fy (16.82 plus or minus.23; p less than .043) was significantly lower during the Smith machine squat. The mean descent/ascent ratio of the magnitude of the resultant force vector of all three axes for the Smith machine and iRED was 0.95 and 0.72, respectively. Also, the point at which maximum Fz occurred in the range of motion (Dzpeak) was at different locations with the two devices.

Amonette, William E.↗

A Damage-Dependent Finite Element Analysis for Fiber-Reinforced Composite Laminates

A progressive damage methodology has been developed to predict damage growth and residual strength of fiber-reinforced composite structure with through penetrations such as a slit. The methodology consists of a damage-dependent constitutive relationship based on continuum damage mechanics. Damage is modeled using volume averaged strain-like quantities known as internal state variables and is represented in the equilibrium equations as damage induced force vectors instead of the usual degradation and modification of the global stiffness matrix.

Coats, Timothy W.↗

EMG responses to maintain stance during multidirectional surface translations

To characterize muscle synergy organization underlying multidirectional control of stance posture, electromyographic activity was recorded from 11 lower limb and trunk muscles of 7 healthy subjects while they were subjected to horizontal surface translations in 12 different, randomly presented directions. The latency and amplitude of muscle responses were quantified for each perturbation direction. Tuning curves for each muscle were examined to relate the amplitude of the muscle response to the direction of surface translation. The latencies of responses for the shank and thigh muscles were constant, regardless of perturbation direction. In contrast, the latencies for another thigh [tensor fascia latae (TFL)] and two trunk muscles [rectus abdominis (RAB) and erector spinae (ESP)] were either early or late, depending on the perturbation direction. These three muscles with direction-specific latencies may play different roles in postural control as prime movers or as stabilizers for different translation directions, depending on the timing of recruitment. Most muscle tuning curves were within one quadrant, having one direction of maximal activity, generally in response to diagonal surface translations. Two trunk muscles (RAB and ESP) and two lower limb muscles (semimembranosus and peroneus longus) had bipolar tuning curves, with two different directions of maximal activity, suggesting that these muscle can play different roles as part of different synergies, depending on translation direction. Muscle tuning curves tended to group into one of three regions in response to 12 different directions of perturbations. Two muscles [rectus femoris (RFM) and TFL] were maximally active in response to lateral surface translations. The remaining muscles clustered into one of two diagonal regions. The diagonal regions corresponded to the two primary directions of active horizontal force vector responses. Two muscles (RFM and adductor longus) were maximally active orthogonal to their predicted direction of maximal activity based on anatomic orientation. Some of the muscles in each of the synergic regions were not anatomic synergists, suggesting a complex central organization for recruitment of muscles. The results suggest that neither a simple reflex mechanism nor a fixed muscle synergy organization is adequate to explain the muscle activation patterns observed in this postural control task. Our results are consistent with a centrally mediated pattern of muscle latencies combined with peripheral influence on muscle magnitude. We suggest that a flexible continuum of muscle synergies that are modifiable in a task-dependent manner be used for equilibrium control in stance.

NASA Discipline Neuroscience↗

Recovery of postural equilibrium control following space flight

DSO 605 represents the first large study of balance control following spaceflight. Data collected during DSO 605 confirm the theory that postural ataxia following short duration spaceflight is of vestibular origin. We used the computerized dynamic posturography technique developed by Nashner et al. to study the role of the vestibular system in balance control in astronauts during quiet stance before and after spaceflight. Our results demonstrate unequivocally that balance control is disrupted in all astronauts immediately after return from space. The most severely affected returning crew members performed in the same way as vestibular deficient patients exposed to this test battery. We conclude that otolith mediated spatial reference provided by the terrestrial gravitational force vector is not used by the astronauts balance control systems immediately after spaceflight. Because the postflight ataxia appears to be mediated primarily by CNS adaptation to the altered vestibular inputs caused by loss of gravitational stimulation, we believe that intermittent periods of exposure to artificial gravity may provide an effective in-flight countermeasure. Specifically, we propose that in-flight centrifugation will allow crew members to retain their terrestrial sensory-motor adapted states while simultaneously developing microgravity adapted states. The dual-adapted astronaut should be able to make the transition from microgravity to unit gravity with minimal sensory-motor effects. We have begun a ground based program aimed at developing short arm centrifuge prescriptions designed to optimize adaptation to altered gravitational environments. Results from these experiments are expected to lead directly to in-flight evaluation of the proposed centrifuge countermeasure. Because our computerized dynamic posturography system was able to (1) quantify the postflight postural ataxia reported by crew members and observed by flight surgeons and scientists, (2) track the recovery of normal (preflight) balance control, (3) differentiate between rookie and veteran subjects, and (4) provide normative and clinical databases for comparison, and because our study successfully characterized postflight balance control recovery in a large cross-section of Shuttle crew members, we recommend that this system and protocol be adopted as a standard dependent measure for evaluating the efficacy of countermeasures and/or evaluating the postflight effects of changing mission durations or activities.

Paloski, William H.↗

Raked circular-cone aerobraking orbital transfer vehicle

An aerobraking orbital transfer vehicle (AOTV) (80) has aerobrake (82) with a blunted raked-off circular-cone configuration. The other components of the AOTV, including command/control module (95), fuel tanks (86, 88, 89 and 91), rocket engines (94) and afterbody (84), are positioned substantially along resultant force axis (104) of the AOTV (80). The axis (104) coincides with the resultant (sum of lift and drag) force vector. Afterbody (84) is mounted behind the aerobrake (82) with its length extending rearwardly from the aerobrake. The base flow clearance angle .phi. of the aerobrake (80) is 25.degree., thus allowing the afterbody (84) to extend rearwardly from the aerobrake (82) to a much greater extent than possible with a raked-off elliptic-cone aerobraking shield configuration. Afterbody size limitation and other problems associated with the raked-off elliptic-cone aerobraking shield configuration are alleviated by the combination of the aerobrake shape and positioning of the fuel tanks (86, 88, 89 and 91), rocket engines (94) and afterbody (84).

Park, Chul↗

Numerical Simulations of Flow Separation Control in Low-Pressure Turbines using Plasma Actuators

A recently introduced phenomenological model to simulate flow control applications using plasma actuators has been further developed and improved in order to expand its use to complicated actuator geometries. The new modeling approach eliminates the requirement of an empirical charge density distribution shape by using the embedded electrode as a source for the charge density. The resulting model is validated against a flat plate experiment with quiescent environment. The modeling approach incorporates the effect of the plasma actuators on the external flow into Navier Stokes computations as a body force vector which is obtained as a product of the net charge density and the electric field. The model solves the Maxwell equation to obtain the electric field due to the applied AC voltage at the electrodes and an additional equation for the charge density distribution representing the plasma density. The new modeling approach solves the charge density equation in the computational domain assuming the embedded electrode as a source therefore automatically generating a charge density distribution on the surface exposed to the flow similar to that observed in the experiments without explicitly specifying an empirical distribution. The model is validated against a flat plate experiment with quiescent environment.

Suzen, Y. B.↗

A Two-Axis Direct Fluid Shear Stress Sensor

This innovation is a miniature or micro sized semiconductor sensor design that provides two axis direct non-intrusive measurement of skin friction or wall shear stress in fluid flow. The sensor is fabricated by micro-electro-mechanical system (MEMS) technology, enabling small size and low cost reproductions. The sensors have been fabricated by utilizing MEMS fabrication processes to bond a sensing element wafer to a fluid coupling wafer. This layering technique provides for an out of plane dimension that is on the same order of length as the inplane dimensions. The sensor design has the following characteristics: a shear force collecting plate with dimensions that can be tailored to various application specific requirements such as spatial resolution, temporal resolution and shear force range and resolution. This plate is located coplanar to both the sensor body and flow boundary, and is connected to a dual axis gimbal structure by a connecting column or lever arm. The dual axis gimbal structure has torsional hinges with embedded piezoresistive torsional strain gauges which provide a voltage output that is correlated to the applied shear stress (and excitation current) on force collection plate that is located on the flow boundary surface (hence the transduction method). This combination of design elements create a force concentration and resolution structure that enables the generation of a large stress on the strain gauge from the small shear stress on the flow boundary wall. This design as well as the use of back side electrical contacts establishes a non-intrusive method to quantitatively measure the shear force vector on aerodynamic bodies.

Adcock, Edward E.↗

Evaluation of Drogue Parachute Damping Effects Utilizing the Apollo Legacy Parachute Model

Drogue parachute damping is required to dampen the Orion Multi Purpose Crew Vehicle (MPCV) crew module (CM) oscillations prior to deployment of the main parachutes. During the Apollo program, drogue parachute damping was modeled on the premise that the drogue parachute force vector aligns with the resultant velocity of the parachute attach point on the CM. Equivalent Cm(sub q) and Cm(sub alpha) equations for drogue parachute damping resulting from the Apollo legacy parachute damping model premise have recently been developed. The MPCV computer simulations ANTARES and Osiris have implemented high fidelity two-body parachute damping models. However, high-fidelity model-based damping motion predictions do not match the damping observed during wind tunnel and full-scale free-flight oscillatory motion. This paper will present the methodology for comparing and contrasting the Apollo legacy parachute damping model with full-scale free-flight oscillatory motion. The analysis shows an agreement between the Apollo legacy parachute damping model and full-scale free-flight oscillatory motion.

Currin, Kelly M.↗

Single and Multi-Pulse Low-Energy Conical Theta Pinch Inductive Pulsed Plasma Thruster Performance

Fabricated and tested CTP IPPTs at cone angles of 20deg, 38deg, and 60deg, and performed direct single-pulse impulse bit measurements with continuous gas flow. Single pulse performance highest for 38deg angle with impulse bit of approx.1 mN-s for both argon and xenon. Estimated efficiencies low, but not unexpectedly so based on historical data trends and the direction of the force vector in the CTP. Capacitor charging system assembled to provide rapid recharging of capacitor bank, permitting repetition-rate operation. IPPT operated at repetition-rate of 5 Hz, at maximum average power of 2.5 kW, representing to our knowledge the highest average power for a repetitively-pulsed thruster. Average thrust in repetition-rate mode (at 5 kV, 75 sccm argon) was greater than simply multiplying the single-pulse impulse bit and the repetition rate.

Hallock, Ashley K.↗

Modeling and Simulation for Exercise Vibration Isolation and Stabilization System Design

The microgravity environment that crew members experience on orbit presents a well-known health challenge, particularly when it comes to loss of muscle and bone mass. To counteract these negative effects, exercise countermeasures play a critical role in the daily routine of the crew on the International Space Station (ISS). To help inform requirements for upcoming exploration missions such as the Gateway Program, a new device, called the European Enhanced Exploration Exercise Device (E4D), is being built by the European Space Agency through their contractor, the Danish Aerospace Company. The E4D is being demonstrated on the ISS and is unique from other current exercise devices in that it provides four separate modalities in a single device: resistive, cycle ergometry, seated aerobic rowing, and rope pulling. To support the integration of E4D on ISS, a passive Vibration Isolation and Stabilization (VIS) system was required by NASA, and this responsibility was given to the Johnson Space Center. This paper describes the end-to-end process of modeling, simulation, and analysis used to inform the mechanical design of the VIS system. The process begins with the collection of representative exerciser motion capture (MoCap) through ground-based testing with the developmental E4D in both the Prototype Immersive Technology (PIT) Laboratory and the Active Response Gravity Offload System (ARGOS) facility at the Johnson Space Center. These collected MoCap data are processed through human biomechanics modeling to create forcing functions as input to a multibody dynamics simulation of the combined E4D/VIS system, with numerous resulting outputs. These outputs include microgravity accelerations, overall system displacements, internal and transmitted loads, as well as collisions. Microgravity accelerations are compared for compliance against ISS requirements while displacements are used for sway space determinations on the design and volumetric constraints within the targeted module. Internal loads are supplied to the supporting stress analysis teams and external loads for structural loads and dynamics teams, both at NASA and ESA. Finally, contact and clearance analysis is performed using the simulation to eliminate potential design issues. To ensure that the elements of the multibody simulation were verified and validated, correlation against multiple VIS related ground hardware testbeds was performed and characterized. In addition to the isolation part of the VIS problem, stabilization is also key to the integrated performance and evaluation. Due to the difficulty in defining ISS requirements in this area, the stability of the exerciser was inspected via analysis. Loss of balance was defined analytically as occurring when the resultant force vector acting on the exerciser lies outside the base of support of the feet. Both the VIS and E4D teams have recently gone through their Critical Design Reviews (CDRs) and the iterative model-based approach has been integral to inform mechanical design, particularly in the case of the VIS. This same end-to-end approach is now being applied for the Gateway Program, where an Exploration Exercise Device (EED) derived from the E4D and notional VIS for the device are under concept development.

Countermeasures↗

Modeling holes and voids in three dimensions using a single element within the Extended Finite Element framework

This paper introduces a highly efficient computational approach using the extended finite element method to model three-dimensional mechanics of holes and voids. The defect is encapsulated within a single element with a tailored exponential enrichment function that captures the behavior near the discontinuity boundary and can account for the pressure acting on the void’s surface through an equivalent nodal force vector. The method’s results were compared against analytical solutions and conventional finite element method results for problems involving single and multiple holes. The comparison demonstrated that the method provides accurate stress concentration estimates while adhering to computational constraints.

Adnan Shahriar↗

Single-Vector Calibration of Wind-Tunnel Force Balances

An improved method of calibrating a wind-tunnel force balance involves the use of a unique load application system integrated with formal experimental design methodology. The Single-Vector Force Balance Calibration System (SVS) overcomes the productivity and accuracy limitations of prior calibration methods. A force balance is a complex structural spring element instrumented with strain gauges for measuring three orthogonal components of aerodynamic force (normal, axial, and side force) and three orthogonal components of aerodynamic torque (rolling, pitching, and yawing moments). Force balances remain as the state-of-the-art instrument that provide these measurements on a scale model of an aircraft during wind tunnel testing. Ideally, each electrical channel of the balance would respond only to its respective component of load, and it would have no response to other components of load. This is not entirely possible even though balance designs are optimized to minimize these undesirable interaction effects. Ultimately, a calibration experiment is performed to obtain the necessary data to generate a mathematical model and determine the force measurement accuracy. In order to set the independent variables of applied load for the calibration 24 NASA Tech Briefs, October 2003 experiment, a high-precision mechanical system is required. Manual deadweight systems have been in use at Langley Research Center (LaRC) since the 1940s. These simple methodologies produce high confidence results, but the process is mechanically complex and labor-intensive, requiring three to four weeks to complete. Over the past decade, automated balance calibration systems have been developed. In general, these systems were designed to automate the tedious manual calibration process resulting in an even more complex system which deteriorates load application quality. The current calibration approach relies on a one-factor-at-a-time (OFAT) methodology, where each independent variable is incremented individually throughout its full-scale range, while all other variables are held at a constant magnitude. This OFAT approach has been widely accepted because of its inherent simplicity and intuitive appeal to the balance engineer. LaRC has been conducting research in a "modern design of experiments" (MDOE) approach to force balance calibration. Formal experimental design techniques provide an integrated view to the entire calibration process covering all three major aspects of an experiment; the design of the experiment, the execution of the experiment, and the statistical analyses of the data. In order to overcome the weaknesses in the available mechanical systems and to apply formal experimental techniques, a new mechanical system was required. The SVS enables the complete calibration of a six-component force balance with a series of single force vectors.

Parker, P. A.↗

MSFC-TVC | TB-03: Derivation of Thrust Vector Control (TVC) Actuator-Force / Gimbal-Torque Transformation Matrix

Thrust vector control (TVC) systems for rocket engine propulsion traditionally use a simple linear relationship to convert between actuator forces and torques about the engine gimbal’s center-of-rotation (COR). As shown in Equation (1), the torque about the gimbal COR is proportional to the applied actuator force and the TVC moment arm (MA)—the perpendicular distance between the TVC actuator’s line-of-action (LOA) and the engine gimbal’s COR. While this fundamental relationship remains valid and accurate in a two-dimensional (2D), one-degree-of-freedom (1-DOF) context—particularly in its non-linear formulation as described in the ER63 Technical Bulletin TB-02 (Derivation of Thrust Vector Control (TVC) Engine-Gimbal / Actuator Moment-Arm Geometry)—it becomes limited when extended to three-dimensional (3D), two-degree-of-freedom (2-DOF) analyses. In 3D, out-of-plane angular displacements can arise, causing the gimbaled engine plane-of-motion to become non-coplanar with the respective actuator plane-of-motion. Such misalignments occur due to the rod-end (RE) and/or tail-stock (TE) mounting geometry of individual TVC actuators. These geometric complexities lead to inaccuracies in calculating engine torques and corresponding actuator forces if only the traditional TVC MA relationship is employed. For higher gimbal angular displacements (e.g., greater than 5 degrees), these inaccuracies become more pronounced, necessitating a more robust mathematical framework. This document presents a comprehensive 3D (2-DOF) derivation of a transformation matrix that accurately converts between gimbaled engine torques and TVC actuator forces. By incorporating the necessary geometric and rotational considerations, this new approach corrects the limitations of the traditional TVC MA method. Subsequent sections compare the newly formulated approach to the traditional method, demonstrating its enhanced accuracy and reliability for a broad range of gimbaled engine conditions.

Thrust Vector Control↗

Thermal and Pressure Characterization of a Wind Tunnel Force Balance Using the Single Vector System

Wind tunnel research at NASA Langley Research Center s 31-inch Mach 10 hypersonic facility utilized a 5-component force balance, which provided a pressurized flow-thru capability to the test article. The goal of the research was to determine the interaction effects between the free-stream flow and the exit flow from the reaction control system on the Mars Science Laboratory aeroshell during planetary entry. In the wind tunnel, the balance was exposed to aerodynamic forces and moments, steady-state and transient thermal gradients, and various internal balance cavity pressures. Historically, these effects on force measurement accuracy have not been fully characterized due to limitations in the calibration apparatus. A statistically designed experiment was developed to adequately characterize the behavior of the balance over the expected wind tunnel operating ranges (forces/moments, temperatures, and pressures). The experimental design was based on a Taylor-series expansion in the seven factors for the mathematical models. Model inversion was required to calculate the aerodynamic forces and moments as a function of the strain-gage readings. Details regarding transducer on-board compensation techniques, experimental design development, mathematical modeling, and wind tunnel data reduction are included in this paper.

Lynn, Keith C.↗