Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensic signatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

83 records · Page 5

Demonstration of 151 Sm analysis using Trinity nuclear debris samples

Here, the long-lived fission product 151 Sm (T 1/2 ≈ 90 y) present in archived dissolved Trinity nuclear test debris samples was analyzed using liquid scintillation counting and the results were compared to the expected values based upon historical analysis results. The measured 151 Sm activities were found to agree with the expected values within experimental error. This demonstration validates the use of this technique in situations where the sample is too old for traditional shorter half-life radioactive fission product signatures such as 99 Mo (T 1/2 = 2.75 d), 97 Zr (T 1/2 = 16.7 h), 147 Nd (T 1/2 = 10.98 d), and 153 Sm (T 1/2 = 46.3 h), or too dilute for determining fissions through stable isotope ratio measurements.

151Sm↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

The Seismic Signature of a High-Energy Density Physics Laboratory and Its Potential for Measuring Time-Dependent Velocity Structure

The Z Machine at Sandia National Laboratories is a pulsed power facility for high-energy density physics experiments that can shock materials to extreme temperatures and pressures through a focused energy release of up to ~ 25 MJ in < 100 nanoseconds. It has been in operation for more than two decades and conducts up to ~ 100 experiments, or “shots,” per year. Based on a set of 74 known shot times from 2018, we determined that Z Machine shots produce detectable ~ 3–17 Hz ground motion 12 km away at the Albuquerque Seismological Laboratory, New Mexico (ANMO), borehole seismograph, with peak signal at ~ 7 Hz. The known shot waveforms were used to create a three-component template, leading to the detection of 2339 Z Machine shots since 1998 through single-station cross-correlation. Local seismic magnitude estimates range from local magnitude (M L ) —2 to —1.3 and indicate that only a small fraction of the shot energy is transmitted by seismic phases observable at 12 km distance. The most recent major facility renovation, which was intended to decrease mechanical dissipation, is associated with an abrupt decrease in observed seismic amplitudes at ANMO despite stable maximum shot energy. The highly repetitive impulsive sources are well suited to coda-wave interferometry to investigate time-dependent velocity structures. Relative velocity variations (dv/v) show an annual cycle with amplitude of ~ 0.2%. Local minima are observed in the late spring, and dv/v increases through the summer monsoon rainfall, possibly reflecting patchy saturation as rainfall infiltrates near the eastern edge of the Albuquerque basin. Importantly, the cumulative results demonstrate that forensic seismology can provide insight into long-term operation of facilities such as pulsed-power laboratories, and that their recurring signals may be valuable for studies of time-dependent structure

54 ENVIRONMENTAL SCIENCES↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical vibrational spectroscopic signatures of ammonium diuranate process parameters

Ammonium diuranate (ADU) is commonly encountered in the nuclear fuel cycle; however, previous investigations have shown that ADU is a complex mixture of distinct compounds. Moreover, production parameters are known to heavily influence the composition of the resulting ADU. Here, we examine four samples of ADU prepared at Oak Ridge National Laboratory (ORNL), and one sample of ADU made at Pacific Northwest National Laboratory (PNNL), with the goal of further characterizing and elucidating the effect of processing parameters such as stir rate, strike direction, and temperature on material composition. Process parameters during ADU precipitation at ORNL and PNNL were well documented, and we relate process variables to optical vibrational spectroscopic signatures observed using Raman and infrared (IR) spectroscopy. In addition, powder X-ray diffraction (PXRD) reveals differences in the solid-phase composition of ADU precipitates, but we find that the primary phase is similar to the uranyl oxyhydroxyhydrate mineral metaschoepite. Despite the significant phase contributions of a metaschoepite-like phase, spectroscopic evidence of both nitrate and ammonium are observed for all samples. To gain a more holistic understanding of spectroscopic features of process parameters in ADU, principal component analysis (PCA) is employed and results in observable signatures that relate to the stir rate used during synthesis. These results provide further information about the process-dependence of ADU precipitate composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

An experimental and computational investigation of the structure and spectroscopic signatures of α -UO 3

α-UO 3 is a common intermediate compound found in the nuclear fuel cycle, yet the exact crystal structure of this material has long been debated. Inconsistent computational and experimental data in previous works has led to varying conclusions between authors. Furthermore, to ensure the validity of our results in this work, the structural and spectroscopic signatures of pure phase α-UO 3 are investigated using powder X-ray diffraction and optical vibrational spectroscopy (infrared and Raman). Rietveld refinement of powder X-ray diffraction data on pure phase α-UO 3 collected in this work allows us to propose an alteration to the currently accepted C2mm structure (a = 3.9705 Å, b = 6.8553 Å, c = 4.15955 Å, α = β = γ = 90°) for α-UO 3 with no uranyl [UO 2 2+ ] bonds. Raman spectra collected using two excitation wavelengths (two instruments using 532 nm and one 785 nm) are presented, and differences with recently published results are discussed. Infrared spectra from two instruments used here agree well with recently published results, but the spectral range encompassed in our data extends past what has been reported with modern techniques. Additionally, we provide tentative vibrational mode assignments based on density functional perturbation theory calculations and resulting phonon eigenvector visualizations. Unexpected features in the optical vibrational spectra of α-UO 3 are explained by unique features in the structure we present.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Fractionation of Oxygen Isotopes in Uranium Oxides during Peroxide Precipitation and Dry Air Calcination

The interaction between uranium and oxygen-containing substrates is nearly ubiquitous within the nuclear fuel cycle. Given the well-known and predictable oxygen stable isotope compositions of atmospheric oxygen and meteoric waters around the world, the use of these isotopes as a potential geolocation or processing signature of uranium compounds has been of interest within the nuclear safeguards community. This study focuses on measuring the oxygen-stable isotope composition of synthetically produced uranium oxides to determine the mechanism and extent of fractionation during materials processing relevant to the nuclear fuel cycle. Here, metastudtite [UO 2 O 2 (H 2 O) 2 ] samples were first produced using water and hydrogen peroxide of a known oxygen isotope composition. This starting material was calcined in dry air at temperatures ranging from 300 °C to 1000 °C for 20 h producing oxides ranging in composition from UO 3 +x (0 ≤ x ≤ 0.5) to U 3 O 8 . In addition, calcinations between 500 and 800 °C were performed at different time intervals to evaluate the rate of isotopic equilibration. The δ 18 O values of water bound to metastudtite were measured by thermogravimetric analysis coupled to isotope ratio infrared spectroscopy (TGA–IRIS). A redesigned fluorination manifold was constructed at the University of Utah and was used to extract the bulk oxygen from precipitated and calcined products using bromine pentafluoride (BrF 5 ). Mineralization water on metastudtite (measured by TGA–IRIS) was closely associated with the aqueous environment of precipitation with a fractionation of +3.5 ± 0.6‰. In contrast, bulk oxygen from metastudtite (measured by fluorination and gas chromatography combined with isotope ratio mass spectrometry) was found to have an inconsistent fractionation with precipitation water. Samples calcined in dry air exhibited a wide range of oxygen isotope compositions which increased from δ 18 O = +1.4 ± 0.9‰ at 300 °C to +17.3 ± 0.9‰ at 1000 °C. This variation in δ 18 O values was a result of oxygen exchange with atmospheric O 2 and was found to be rapid at calcination temperatures greater than 600°C—with equilibration occurring in less than 2 h. These results provide insights into the incorporation and exchange of oxygen isotopes during precipitation and calcination processes comparable to those employed within the nuclear fuel cycle and establish a foundation for future investigations to build upon.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗