Global Radiological Source Sorting, Tracking, and Monitoring (Gradsstram) Using Emergin RFID and Web 2.0 Technologies to Provide Total Asset and Information Visualization, Paper at 2009 INMM

Background Thousands of shipments of radioisotopes developed in the United States (U.S.) are transported domestically and internationally for medical and industrial applications, including to partner laboratories in European Union (EU) countries. Over the past five years, the Environmental Protection Agency (EPA), the Department of Energy (DOE), and Oak Ridge National Laboratory (ORNL)1 have worked with state first responder personnel, key private sector supply chain stakeholders, the Department of Homeland Security (DHS), the Department of Transportation (DOT), the Department of Defense (DoD) and the Nuclear Regulatory Commission (NRC) on Radio Frequency Identification (RFID) tracking and monitoring of medical, research and industrial radioisotopes in commerce. ORNL was the pioneer of the international radioisotope shipping and production business. Most radioisotopes made and used today were either made or discovered at ORNL. While most of the radioisotopes used in the commercial sector are now produced and sold by the private market, ORNL still leads the world in the production of exotic, high-value and/or sensitive industrial, medical and research isotopes. The ORNL-EPA-DOE Radiological Source Tracking and Monitoring (RadSTraM) project tested, evaluated, and integrated RFID technologies in laboratory settings and at multiple private-sector shipping and distribution facilities (Perkin Elmer and DHL) to track and monitor common radioisotopes used in everyday commerce. The RFID tracking capability was also tested in association with other deployed technologies including radiation detection, chemical/explosives detection, advanced imaging, lasers, and infrared scanning. At the 2007 EU-U.S. Summit, the leaders of the US Department of Commerce (DOC) and EU European Commission (EC) committed to pursue jointly directed Lighthouse Priority Projects. These projects are intended to foster cooperation and reduce regulatory burdens with respect to transatlantic commerce. The Transatlantic Economic Council (TEC) Lighthouse Project on Radio Frequency Identification (RFID) has been directed to develop a joint framework for cooperation on identification and development of best practices for Radio Frequency Identification (RFID) technologies The RFID Lighthouse Priority Project commits both sides to endeavor to align U.S. and EU regulatory and policy approaches on RFID technologies, including pilot projects in the public sector.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The x-ray light valve: A low-cost, digital radiographic imaging system--Spatial resolution

An x-ray light valve (XLV) coupled with an optical scanner has the potential to meet the need for a low-cost, high quality digital imaging system for general radiography. The XLV/scanner concept combines three well-established, and hence, low-cost technologies: An amorphous selenium (a-Se) layer as an x-ray-to-charge transducer, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. The XLV consists of an a-Se layer and LC cell in a sandwich structure which produces an optical image in the LC layer upon x-ray exposure. The XLV/scanner system consists of an XLV in combination with an optical scanner for image readout. Here, the effect of each component on the spatial resolution of an XLV/scanner system is investigated. A theoretical model of spatial resolution of an XLV is presented based on calculations of the modulation transfer function (MTF) for a-Se and a LC cell. From these component MTFs, the theoretical MTF of the XLV is derived. The model was validated by experiments on a prototype XLV/scanner system. The MTF of the scanner alone was obtained by scanning an optical test target and the MTF of the XLV/scanner system was measured using x rays. From the measured MTF of the scanner, the theoretical MTF of the XLV/scanner system was established and compared with the experimental results. Good general agreement exists between experimental and theoretical results in the frequency range of interest for general radiography, although the theoretical curves slightly overstate the measured MTFs. The experimental MTF of the XLV was compared with the MTF of two clinical systems and was shown to have the capability to exceed the resolution of flat-panel detectors. From this, the authors can conclude that the XLV has an adequate resolution for general radiography. The XLV/scanner also has the potential to eliminate aliasing while maintaining a MTF that exceeds that of a flat-panel imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

60 APPLIED LIFE SCIENCES↗

Design and implementation of wire tension measurement system for MWPCs used in the STAR iTPC upgrade

The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which will be used in the TPC upgrade. The wire tension measurement system causes the wires to vibrate and then it measures the fundamental frequency of the oscillation via a laser based optical platform. The platform can scan the entire wire plane, automatically, in a single run and obtain the wire tension on each wire with high precision. In this paper, the details about the measurement method and the system setup will be described. In addition, the test results for a prototype MWPC to be used in the STAR-iTPC upgrade will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sustainable Shape Memory Elastomers with Reduced Melt Viscosity and Enhanced Stiffness

Melt reactive processing of lignin with nitrile rubber is a promising approach to synthesizing shape memory materials. The strong intramolecular interactions in lignin macromolecular structures, caused by π–π stacking in aromatic rings and hydrogen bonding, often result in large phase separation or low miscibility with rubbers. In this study, we investigated the chemical and molecular characteristics, as well as the stiffness and complex viscosity, of modified kraft lignin melt-reacted with an acrylonitrile/butadiene copolymer containing 41% acrylonitrile (NBR41). To enhance the macromolecular compatibility of kraft lignin with NBR41, kraft lignin was cross-linked with poly(propylene glycol) diglycidyl ether (PPDE) and trimethylolpropane triglycidyl ether (TTE), both rich in epoxy reactive groups capable of forming chemical bonds with hydroxyl and carboxyl groups. Here, our findings demonstrate that the modification of kraft lignin with PPDE and TTE resulted in significantly increased stiffness of the composites. The elastic modulus of NBR41-Kraft lignin-PPDE and NBR41-Kraft lignin-TTE increased by 82 and 162%, respectively. Both the yield strength and Young’s modulus of these two samples showed dramatic improvements. Specifically, the yield strength and Young’s modulus of NBR41-Kraft lignin-TTE increased nearly 4 and 3-fold, respectively, compared to the control sample. Interestingly, despite significant improvements in mechanical properties, the viscosity of NBR41-Kraft lignin-PPDE was substantially lower than that of the control sample. At 210 °C and an angular frequency of 1 rad/s, the complex viscosity of NBR41-Kraft lignin was approximately 100.25 ± 4.77 kPa·s, while that of NBR41-Kraft lignin-PPDE was significantly lower at 56 ± 0.93 kPa·s. These findings were validated through Fourier transform infrared spectroscopy, scanning electron microscopy, dynamic mechanical analysis, thermal characterization, rheological tests, and quasi-elastic neutron scattering techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal strategy for polarization modulation in the LSPE-SWIPE experiment

Context. Cosmic microwave background (CMB) B-mode experiments are required to control systematic effects with an unprecedented level of accuracy. Polarization modulation by a half wave plate (HWP) is a powerful technique able to mitigate a large number of the instrumental systematics. Aims. Our goal is to optimize the polarization modulation strategy of the upcoming LSPE-SWIPE balloon-borne experiment, devoted to the accurate measurement of CMB polarization at large angular scales. Methods. We departed from the nominal LSPE-SWIPE modulation strategy (HWP stepped every 60 s with a telescope scanning at around 12 deg/s) and performed a thorough investigation of a wide range of possible HWP schemes (either in stepped or continuously spinning mode and at different azimuth telescope scan-speeds) in the frequency, map and angular power spectrum domain. In addition, we probed the effect of high-pass and band-pass filters of the data stream and explored the HWP response in the minimal case of one detector for one operation day (critical for the single-detector calibration process). We finally tested the modulation performance against typical HWP-induced systematics. Results. Our analysis shows that some stepped HWP schemes, either slowly rotating or combined with slow telescope modulations, represent poor choices. Moreover, our results point out that the nominal configuration may not be the most convenient choice. While a large class of spinning designs provides comparable results in terms of pixel angle coverage, map-making residuals and BB power spectrum standard deviations with respect to the nominal strategy, we find that some specific configurations (e.g., a rapidly spinning HWP with a slow gondola modulation) allow a more efficient polarization recovery in more general real-case situations. Conclusions. Although our simulations are specific to the LSPE-SWIPE mission, the general outcomes of our analysis can be easily generalized to other CMB polarization experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic-resolution scanning transmission electron microscopy through 50-nm-thick silicon nitride membranes

Silicon nitride membranes can be used for windows of environmental chambers for in situ electron microscopy. We report that aberration corrected scanning transmission electron microscopy (STEM) achieved atomic resolution on gold nanoparticles placed on both sides of a 50-nm-thick silicon nitride membrane at 200 keV electron beam energy. Spatial frequencies of 1/1.2 A were visible for a beam semi-angle of 26.5 mrad. Imaging though a 100-nm-thick membrane was also tested. The achieved imaging contrast was evaluated using Monte Carlo simulations of the STEM imaging of a sample of with a representative geometry and composition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel covariance-based neutrality test of time-series data reveals asymmetries in ecological and economic systems

Systems as diverse as the interacting species in a community, alleles at a genetic locus, and companies in a market are characterized by competition (over resources, space, capital, etc) and adaptation. Neutral theory, built around the hypothesis that individual performance is independent of group membership, has found utility across the disciplines of ecology, population genetics, and economics, both because of the success of the neutral hypothesis in predicting system properties and because deviations from these predictions provide information about the underlying dynamics. However, most tests of neutrality are weak, based on static system properties such as species-abundance distributions or the number of singletons in a sample. Time-series data provide a window onto a system’s dynamics, and should furnish tests of the neutral hypothesis that are more powerful to detect deviations from neutrality and more informative about to the type of competitive asymmetry that drives the deviation. Here, we present a neutrality test for time-series data. We apply this test to several microbial time-series and financial time-series and find that most of these systems are not neutral. Our test isolates the covariance structure of neutral competition, thus facilitating further exploration of the nature of asymmetry in the covariance structure of competitive systems. Much like neutrality tests from population genetics that use relative abundance distributions have enabled researchers to scan entire genomes for genes under selection, we anticipate our time-series test will be useful for quick significance tests of neutrality across a range of ecological, economic, and sociological systems for which time-series data are available. Here, future work can use our test to categorize and compare the dynamic fingerprints of particular competitive asymmetries (frequency dependence, volatility smiles, etc) to improve forecasting and management of complex adaptive systems.

59 BASIC BIOLOGICAL SCIENCES↗

In situ corrosion analysis of Al-Zn-In-Mg-Ti-Ce sacrificial anode alloy

The corrosion behaviour of Al-5Zn-0.02In-1Mg-0.05Ti-0.5Ce (wt.%) alloy has been investigated by immersion test, scanning electron microscopy, energy dispersive X-ray detector, electrochemical impedance spectroscopy and electrochemical noise. The results show that there exist different corrosion types of the alloy in 3.5% NaCl solution with the immersion time. At the initial stage of immersion, pitting due to the precipitates predominates the corrosion with a typical inductive loop at low frequencies in electrochemical impedance spectroscopy. The major precipitates of the alloy are MgZn{sub 2} and Al{sub 2}CeZn{sub 2} particles. The corrosion potentials of the bulk MgZn{sub 2} and Al{sub 2}CeZn{sub 2} alloys are negative with respect to that of {alpha}-Al, so the MgZn{sub 2} and Al{sub 2}CeZn{sub 2} precipitates can act as activation centre and cause the pitting. In the late corrosion, a relative uniform corrosion predominates the corrosion process controlled by the dissolution/precipitation of the In ions and characterized by a capacitive loop at medium-high frequencies in electrochemical impedance spectroscopy. The potential noise of the pitting shows larger amplitude fluctuation and lower frequency, but the potential noise of the uniform corrosion occurs with smaller amplitude fluctuation and higher frequency.

36 MATERIALS SCIENCE↗

THREE-DIMENSIONAL STRUCTURE OF MICROWAVE SOURCES FROM SOLAR ROTATION STEREOSCOPY VERSUS MAGNETIC EXTRAPOLATIONS

We use rotation stereoscopy to estimate the height of a steady-state solar feature relative to the photosphere, based on its apparent motion in the image plane recorded over several days of observation. The stereoscopy algorithm is adapted to work with either one- or two-dimensional data (i.e., from images or from observations that record the projected position of the source along an arbitrary axis). The accuracy of the algorithm is tested on simulated data, and then the algorithm is used to estimate the coronal radio source heights associated with the active region NOAA 10956, based on multifrequency imaging data over seven days from the Siberian Solar Radio Telescope near 5.7 GHz, the Nobeyama Radio Heliograph at 17 GHz, as well as one-dimensional scans at multiple frequencies spanning the 5.98-15.95 GHz frequency range from the RATAN-600 instrument. The gyroresonance emission mechanism, which is sensitive to the coronal magnetic field strength, is applied to convert the estimated radio source heights at various frequencies, h(f), to information about magnetic field versus height B(h), and the results are compared to a magnetic field extrapolation derived from photospheric magnetic field observations obtained by Hinode and Michelson Doppler Imager. We found that the gyroresonant emission comes from heights exceeding the location of the third gyrolayer irrespective of the magnetic extrapolation method; implications of this finding for coronal magnetography and coronal plasma physics are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooperative Adsorption of Trehalose to DPPC Monolayers at the Water-Air Interface Studied with Vibrational Sum Frequency Generation

A combination of surface tension, surface-specific vibrational spectroscopy, and differential scanning calorimetry experiments were performed to examine the ability of lipid films to enrich interfacial organic content by attracting soluble, neutral saccharides from bulk aqueous solution. This “cooperative adsorption” hypothesis has been proposed as a possible source of the high organic fractions found in sea spray aerosols and is believed to be responsible for cryoprotection in some organisms. Experiments described in this work show that the neutral disaccharide trehalose (Tre) is drawn to lipid films comprised of dipalmitoylphosphatidylcholine (DPPC), a saturated lipid that is a major component of most eukaryotic cells. The effects of Tre on DPPC monolayer structure and organization were tested with tightly packed monolayers in the two-dimensional solid phase (40 Å2/molecule) and more expanded monolayers in the two dimensional liquid condensed phase (55 Å2/molecule). Surface tension data show that DPPC monolayer behaviour remains largely unchanged until Tre bulk concentrations are sufficiently high (= 50 mM). In contrast, surface specific vibrational sum frequency spectra show that when Tre bulk concentrations are = 10 mM, DPPC monolayers in their liquid condensed state (55 Å2/molecule) became more ordered, implying relatively strong noncovalent interactions between the two species. Tre also induces changes in DPPC bilayer behaviour as evidenced by a gel to liquid crystalline phase transition temperature that increases with increasing Tre concentration. This result suggests that Tre associates with the DPPC headgroups in very specific ways leading to partial dehydration. Together, these results support the cooperative adsorption mechanism under some circumstances, namely that there is a minimum aqueous phase Tre concentration required to induce observable structural changes in a lipid monolayer, and that these effects are most pronounced with DPPC monolayers in their liquid condensed state compared to a tightly packed 2-dimensional solid.

Link, Katie A.↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

Brillouin optical reflectometer with a Brillouin active filter

A new scheme of a fibre-optic Brillouin reflectometer is experimentally studied, in which the spectral line of spontaneous Brillouin scattering is selected by an active Brillouin filter represented by the tested fibre itself. To improve the reflectometer characteristics, a cyclic code and Raman amplification of the scattering signal are applied. With an averaging time of 5 min, scanning of 25 km of fibre with a spatial resolution of 4 m and a sampling resolution of 1 m are provided. The root-mean-square deviation in determining the Brillouin frequency is less than 1.1 MHz. The reflectometer sensitivity is evaluated with respect to the temperature changes and mechanical deformation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

False-Positive Results and Incidental Findings with Annual CT or PET/CT Surveillance in Asymptomatic Patients with Resected Stage III Melanoma

Objective: The aim of this study was to quantify false-positive and incidental findings from annual surveillance imaging in asymptomatic, American Joint Committee on Cancer stage III melanoma patients. Methods: This was a cohort study of patients treated at Melanoma Institute Australia (2000–2015) with baseline computed tomography (CT) or positron emission tomography (PET)/CT imaging and at least two annual surveillance scans. False-positives were defined as findings suspicious for melanoma recurrence that were not melanoma, confirmed by histopathology, subsequent imaging, or clinical follow-up, while incidental findings were defined as non-melanoma-related findings requiring further action. Outcomes of incidental findings were classified as ‘benign’ if they resolved spontaneously or were not seriously harmful; ‘malignant’ if a second malignancy was identified; or ‘other’ if potentially harmful. Results: Among 154 patients, 1022 scans were performed (154 baseline staging, 868 surveillance) during a median follow-up of 85 months (interquartile range 56–112); 57 patients (37%) developed a recurrence. For baseline and surveillance imaging, 124 false-positive results and incidental findings were identified in 81 patients (53%). The frequency of these findings was 5–14% per year, and an additional 181 tests, procedures, and referrals were initiated to investigate these findings. The diagnosis was benign in 109 findings of 124 findings (88%). Fifteen patients with a benign finding underwent an unnecessary invasive procedure. Surveillance imaging identified distant metastases in 20 patients (13%). Conclusion: False-positive results and incidental findings occur in at least half of all patients undergoing annual surveillance imaging, and the additional healthcare use is substantial. These findings persist over time. Clinicians need to be aware of these risks and discuss them with patients, alongside the expected benefits of surveillance imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

Here, we report the rf performance of a single-cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120-160 °C with a nitrogen partial pressure of ~25 mTorr. This increase in quality factor as well as the Q-rise phenomenon (anti-Q-slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N 2 -treated at 120 °C and at 140 °C, showed no degradation in accelerating gradient, however the accelerating gradient was reduced by ~25% with a 160 °C N 2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb 2 O 5 , NbO and NbN (1-x) O x within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.

36 MATERIALS SCIENCE↗

Effect of Multi-Walled Carbon Nanotubes on Viscoelastic Properties of PP/Reed Flour Composites

The objective of this investigation was to evaluate the influence of multi-wall carbon nanotubes (MWCNTs) on the dynamic mechanical properties of polypropylene (PP)/reed flour (RF) composites. The experimental samples were prepared through the melt mixing of PP/RF at 50% weight ratios, with various amounts of MWCNTs (0, 1, 2, 3 and 5 phr) in a twin-screw extruder, then the samples made by injection molding. The amount of maleic anhydride grafted polypropylene (PP-g-MA) as a coupling agent was fixed at 2 phr for all formulations. Dynamic mechanical analysis (DMA) tests were carried out to investigate the viscoelastic behavior of nanocomposites. The dynamic mechanical properties such as storage modulus (Eʹ), loss modulus (Eʺ), and damping coefficient (tan δ) of nanocomposites were investigated in the temperature range of −80 to 160 °C at a step of 5 °C and frequency of 1 Hz. The morphology of the specimens was characterized using field emission scanning electron microscope (FE-SEM) technique. Results indicated that the storage modulus of samples was found to increase with incorporation of MWCNTs while damping properties registered a decrease, owing to the reinforcing effect of CNTs into the composites. Moreover, CNTs addition leads to a positive shift in glass transition temperature (T{sub g}), which is explained on the molecular mobility of the polymer chains behavior. Additionally, the minimum adhesion factor is related to samples containing 2 phr MWCNTs which provides the best interaction between polymer and fibers. FE-SEM micrographs showed a predominantly homogeneous CNTs distribution through the composites; however, some aggregates were observed at higher CNTs fractions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of bond line discontinuities in a high-Mn TWIP steel pipe welded by HF-ERW

In this work, the microstructure and defects in a high-frequency electrical resistance welded (HF-ERW) pipe of high-Mn twinning-induced plasticity (TWIP) steel were characterized. The microstructure of the base metal and the bond line were examined using both optical microscopy and scanning electron microscopy. The features of the bond line were similar to those of conventional steel. Simultaneously, the circumferential ductility was evaluated via a flaring test. It was concluded that the deterioration of the circumferential ductility in a high-Mn TWIP steel pipe was caused by irregular shaped oxide defects and a penetrator that had been formed during welding. Specifically, the penetrator, which is composed of MnO and Mn{sub 2}SiO{sub 4}, was found to be the most influential on the circumferential ductility of the welded pipe. The penetrator was analyzed using both an electron probe micro analyzer and transmission electron microscopy, and the formation sequence of the penetrator was evaluated. - Highlights: •This study focused on applying the HF-ERW process to the seam welding of expandable pipe using TWIP steels. •For improvement of the circumferential ductility, deterioration factors were characterized. •Penetrator which would mainly deteriorate the circumferential ductility consisted of round MnO and Mn{sub 2}SiO{sub 4}. •Metallurgical evidence of existing theory regarding the mechanism of defect formation during the HF-ERW was characterized.

36 MATERIALS SCIENCE↗

Surface treatment of polypropylene (PP) film by 50 Hz dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure

Thin films of polypropylene (PP) are treated for improving hydrophilicity using non-thermal plasma generated by 50 Hz line frequency dielectric barrier discharge produced in air and argon/air mixture at atmospheric pressure. PP samples before and after the treatments are studied using contact angle measurements, surface free energy calculations and scanning electron microscopy (SEM). Distilled water (H{sub 2}O), glycerol (C{sub 3}H{sub 8}O{sub 3}) and diiodomethane (CH{sub 2}I{sub 2}) are used as test liquids. The contact angle measurements between test liquids and PP samples are used to determine total surface free energy using sessile drop technique. PP films show a remarkable increase in surface free energy after plasma treatment. SEM analysis of the plasma-treated PP films shows that plasma treatment introduces greater roughness on the surface leading to the increased surface free energy. Furthermore, it is found that introducing a small quantity of argon can enhance the surface treatment remarkably.

36 MATERIALS SCIENCE↗