Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency selective surfaces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A machining digital twin for hybrid manufacturing

Hybrid manufacturing consisting of metal additively manufactured preforms and computer numerical control (CNC) machining has been established to be an effective method for high material use rates. However, hybrid manufacturing introduces unique challenges. Near-net shape designs are typically selected, which result in a smaller margin for part placement within the stock and stringent requirements for work coordinate system identification. Additionally, less stock material reduces the preform stiffness, which limits the material removal rates during machining. This paper demonstrates a digital twin for CNC machining of a wire arc additively manufactured preform that implements: 1) structured light scanning for stock model identification and tool path generation; 2) a fused filament fabrication apparatus to attach temporary fiducials and scan targets to the preform that enable coordinate system definition for both the CAM and CNC machine; 3) preform and tool tip frequency response function measurements to enable stable milling parameter selection; and 4) post-manufacturing measurements of geometry, surface finish, and structural dynamics to confirm designer intent. These efforts define key components of the machining digital twin for hybrid manufacturing.

36 MATERIALS SCIENCE↗

Making Curved Frequency-Selective Microwave Reflectors

Prototype curved lightweight dichroic microwave reflectors designed to be highly reflective in X and K(suba) frequency bands and highly transmissive in K(subu) and S bands. Conductive grid elements formed photolithographically on curved reflector surfaces. Intended for use as subreflectors of main paraboloidal antenna reflector to enable simultaneous operation in both prime-focus configuration in K(subu) and S bands and Cassegrain configuration in X and K(suba) bands. Basic concepts of reflectors described in "Frequency-Selective Microwave Reflectors" (NPO-18701). "Double Square-Loop Dichroic Microwave Reflector" (NPO-18676), "Triband Circular-Loop Dichroic Microwave Reflector" (NPO-18714), and "Improved Dichroic Microwave Reflector" (NPO-18664).

Hickey, Gregory S.↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗

Methods and devices configured to operated scanning tunneling microscopes using out-of-bandwidth frequency components added to bias voltage and related software

In the system and method disclosed, an ultrahigh vacuum (UHV) scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from the Si(100)-2X1:H surface by injecting electrons at a negative sample bias voltage. A new lithography method is disclosed that allows the STM to operate under imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative sample bias voltage to deliver the required energy for hydrogen removal. The resulted current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM's feedback loop. This approach offers a significant potential for controlled and precise removal of hydrogen atoms from a hydrogen-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

Moheimani, Seyed Omid Reza↗

Modeling the Effect of Surface Platinum–Tin Alloys on Propane Dehydrogenation on Platinum–Tin Catalysts

Uncertainty analysis, reported experimental literature data, and density functional theory were synthesized to model the effect of surface tin coverage on platinum-based catalysts for nonoxidative propane dehydrogenation to propylene. Here, this study tests four different platinum–tin skin surface models as potential catalytic sites, Pt 3 Sn/Pt(100), PtSn/Pt(100), Pt 3 Sn/Pt(111), and Pt 2 Sn/Pt(211), and compares them to the corresponding pure Pt surface sites using an uncertainty analysis methodology that uses BEEF-vdW with its ensembles (BMwE) to generate the uncertainty for the energies of the intermediates and transition states. One experimental data set with two experimental observations, selectivity to propylene and turnover frequency of propylene, was used as a calibration data set to evaluate the impact of the experimental data on informing the models. This study finds that the prior model for Pt 3 Sn/Pt(100) is the most active and Pt 2 Sn/Pt(211) is the most selective toward propylene. Active sites on the (100) facet have the highest probability of being responsible for C 1 and C 2 product formations (C–C bond cleavage). Increasing the Sn coverage on the (100) surface facet to a PtSn/Pt(100) active site leads to a significantly reduced rate and might explain the experimentally observed higher selectivity of Sn-doped catalysts relative to pure Pt catalysts. Next, this study finds that for all surfaces, except PtSn/Pt(100), the rate-controlling steps are the initial dehydrogenation steps alongside some partially rate-controlling second dehydrogenation steps. For PtSn/Pt(100), only the initial terminal dehydrogenation step to CH 3 CH 2 CH 2 * and second dehydrogenation steps are rate-controlling. Next, the calibrated models for all surfaces were found to be selective toward propylene production and model the reported turnover frequency successfully. Nevertheless, Pt 2 Sn/Pt(211) emerges as the active site with some (minor) evidence as the main active site based on Jeffreys’ scale interpretation of Bayes factors. This observation agrees with prior studies that also found step sites to be most likely the most relevant active sites for pure Pt catalysts. Overall, the results indicate that tin, in addition to affecting the binding strength of the adsorbed species, prevents deeper dehydrogenation (reducing coking) and cracking reactions through increasing activation barriers for unwanted side reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vibrational sum frequency generation spectroscopy reveals the inertness of chromium oxide (001) surfaces

Nanoengineered metal oxides such as Cr(III)-oxide (chromia) films have diverse potential applications in corrosion inhibition, remediation, energy generation, catalysis, data storage, and biological and environmental systems. Concerns about material degradation or oxidation to toxic chromate necessitate an understanding of chromia/aqueous interfaces, beginning with their hydroxylation and hydration behavior. Vibrational sum-frequency generation spectroscopy (vSFG) provides specific molecular-level information about water at the oxide/aqueous junction with high surface selectivity. To overcome the strong absorber problem typical of certain metal oxides in the UV–visible range during nonlinear optical studies, we employed molecular beam epitaxy to deposit transparent, epitaxial nanofilms of Cr 2 O 3 with (001) crystalline orientation on sapphire (Al 2 O 3 (001)) substrates, as confirmed by atomic force microscopy and X-ray diffraction. vSFG spectra of the air and water interfaces of the Cr 2 O 3 (001) films reveal hydroxyl features corresponding to both dissociated and molecular water on the surface. In contrast to the dangling hydroxyls found on the bare Al 2 O 3 (001) substrate, the hydroxyl groups on the deposited Cr 2 O 3 (001) nanofilm do not readily undergo isotopic H/D exchange when exposed to varying forms of D 2 O under ambient conditions. When considering the chemistries of the corresponding trivalent cations in aqueous solution, the finding is at variance with their similar acidities and proton exchange dynamics but consistent with markedly slower inner-sphere water ligand exchange of hexaquo Cr 3+ . This finding challenges the idea that proton and water exchange at the water/Cr₂O₃(001) interface are solely correlated, driven by the strength of metal-bridging oxygen bonds and surface hydroxyl distribution, without direct causation.

Boamah-Agyemang, Mavis D. [Pacific Northwest Natio↗

Validating a large geophysical data set: Experiences with satellite-derived cloud parameters

We are validating the global cloud parameters derived from the satellite-borne HIRS2 and MSU atmospheric sounding instrument measurements, and are using the analysis of these data as one prototype for studying large geophysical data sets in general. The HIRS2/MSU data set contains a total of 40 physical parameters, filling 25 MB/day; raw HIRS2/MSU data are available for a period exceeding 10 years. Validation involves developing a quantitative sense for the physical meaning of the derived parameters over the range of environmental conditions sampled. This is accomplished by comparing the spatial and temporal distributions of the derived quantities with similar measurements made using other techniques, and with model results. The data handling needed for this work is possible only with the help of a suite of interactive graphical and numerical analysis tools. Level 3 (gridded) data is the common form in which large data sets of this type are distributed for scientific analysis. We find that Level 3 data is inadequate for the data comparisons required for validation. Level 2 data (individual measurements in geophysical units) is needed. A sampling problem arises when individual measurements, which are not uniformly distributed in space or time, are used for the comparisons. Standard 'interpolation' methods involve fitting the measurements for each data set to surfaces, which are then compared. We are experimenting with formal criteria for selecting geographical regions, based upon the spatial frequency and variability of measurements, that allow us to quantify the uncertainty due to sampling. As part of this project, we are also dealing with ways to keep track of constraints placed on the output by assumptions made in the computer code. The need to work with Level 2 data introduces a number of other data handling issues, such as accessing data files across machine types, meeting large data storage requirements, accessing other validated data sets, processing speed and throughput for interactive graphical work, and problems relating to graphical interfaces.

Kahn, Ralph↗

Piezoelectric cantilever sensors

A piezoelectric cantilever with a non-piezoelectric, or piezoelectric tip useful as mass and viscosity sensors. The change in the cantilever mass can be accurately quantified by monitoring a resonance frequency shift of the cantilever. For bio-detection, antibodies or other specific receptors of target antigens may be immobilized on the cantilever surface, preferably on the non-piezoelectric tip. For chemical detection, high surface-area selective absorbent materials are coated on the cantilever tip. Binding of the target antigens or analytes to the cantilever surface increases the cantilever mass. Detection of target antigens or analytes is achieved by monitoring the cantilever's resonance frequency and determining the resonance frequency shift that is due to the mass of the adsorbed target antigens on the cantilever surface. The use of a piezoelectric unimorph cantilever allows both electrical actuation and electrical sensing. Incorporating a non-piezoelectric tip (14) enhances the sensitivity of the sensor. In addition, the piezoelectric cantilever can withstand damping in highly viscous liquids and can be used as a viscosity sensor in wide viscosity range.

Shih, Wan Y.↗

Finite element solution of low bond number sloshing

The dynamics of liquid propellant in a low Bond number environment which are critical to the design of spacecraft systems with respect to orbital propellant transfer and attitude control system were investigated. Digital computer programs were developed for the determination of liquid free surface equilibrium shape, lateral slosh natural vibration mode shapes, and frequencies for a liquid in a container of arbitrary axisymmetric shape with surface tension forces the same order of magnitude as acceleration forces. A finite volume element representation of the liquid was used for the vibration analysis. The liquid free surface equilibrium shapes were computed for several tanks at various contact angles and ullage volumes. A configuration was selected for vibration analysis and lateral slosh mode shapes and natural frequencies were obtained. Results are documented.

Wohlen, R. L.↗

Surface acoustic wave sensor for refrigerant leakage detection

A SAW sensor is optimized for detection of refrigerant leakage in a refrigerant system or other gases, vapors, explosives or chemicals of interest. The SAW sensor includes a piezoelectric substrate; an interdigitated transducer deposited on the piezoelectric substrate, the interdigitated transducer having an input portion that receives input surface acoustic waves and an output portion that emits output surface acoustic waves; and a refrigerant sensor film located between the input portion and the output portion of the interdigitated transducer, the refrigerant sensor film including a sorbent material that is selected for preferential adsorption of a target refrigerant over atmospheric gases. Adsorption of the target refrigerant by the sorbent material results in a frequency shift of a frequency of the output surface acoustic waves relative to a frequency of the input surface acoustic waves. The sorbent material may be a metal organic framework (MOF) material, a covalent organic framework (COF) material, a porous organic cage or organic macrocyles such as calix [n] arene and its related derivatives.

Kunapuli, Raghuit Prasad↗

Resonance plasmonic coupling: selective enhancement of band edge emission over trap state emission of CdSe quantum dots

The photoluminescence properties of quantum dots (QDs) are often enhanced by eliminating surface trap states through chemical methods. Alternatively, a physical approach is presented here for improving photoluminescence purity in QDs by employing frequency-specific plasmon resonance coupling. Emitter-bound plasmonic hybrids are designed by electrostatically binding negatively charged QDs in water to positively charged gold nanoparticles having a thin polymer coating. Herein, two types of QDs are used: (i) bare CdSe, which exhibits both band edge and trap state emission, and (ii) CdSe overcoated with a ZnS shell (CdSe/ZnS) devoid of trap state emission. Tuning the extinction spectrum of the plasmonic system to match the band edge emission of CdSe enables the selective enhancement of band edge emission over trap state emission. Excellent match in the extinction spectrum of the gold nanoparticle with both, experimentally calculated photoluminescence enhancement factor and theoretically calculated radiative rate enhancement signifies the role of frequency-specific plasmon resonance coupling. Plasmon-coupled photoluminescence of CdSe/ZnS is further investigated by varying the number density of emitter on the surface of plasmonic nanoparticle. An enhancement in the photoluminescence is observed at a lower emitter density of CdSe/ZnS and the photoluminescence enhancement factor closely follows the plasmon resonance. However, photoluminescence quenching occurs with an increase in CdSe/ZnS due to plasmon-assisted nonradiative energy transfer between nearby QDs, as indicated by a red shift in the PL maximum. These studies establish that resonance plasmonic coupling is a convenient physical strategy for tuning the intrinsic photoluminescence properties of QDs for various optoelectronic applications.

Paul, Livin↗

Optimum frequencies of passive microwave radiometer for tropospheric path-length correction

Radio-astronomical observations require accurate calibration of tropospheric path length. Such calibration can be achieved by microwave radiometers operating near the 22-GHz water vapor line. However, the performances of current passive microwave radiometers are meteorology-profile dependent. This is due mainly to incorrect frequency combinations and to saturation of brightness temperatures. By properly selecting an optimum frequency pair and removing the saturation effect, the dependency is alleviated and can be further adjusted by surface measurements alone. Hence, a universal calibration equation is applicable to all environmental conditions. Optimum frequency pairs are systematically searched. Simulation analysis indicates that calibration for the tropospheric water-vapor path-length error is better than 0.3 cm at zenith and better than 2 cm for an elevation angle as low as 10 deg.

Wu, S.-C.↗

A Review of Variable-impedance Acoustic Liner Concepts Developed at NASA

This paper presents results attained in the NASA Langley Research Center test rigs using acoustic liners for which the impedance varies over the liner surface. These liners are typically designed for significant sound absorption over a wide frequency range, but it is also possible to design them to achieve increased absorption at selected frequencies. A brief review is provided regarding a number of variable-impedance concepts. The first is a modified version of a conventional two-layer liner, in which the embedded septum location and flow resistance are different for adjacent core chambers. Two concepts employ core chambers with different lengths, one with bent chambers to allow packaging within a limited volume, and the other with shared inlet ports to reduce the surface porosity. The last employs a perforated facesheet in which the hole diameter and porosity are varied over the surface of the liner. Data acquired in the NASA normal incidence and grazing flow impedance tubes are used to demonstrate the capabilities of these concepts. Impedance prediction models are also presented for comparison with these measured data.

Michael G. Jones↗

Harnessing the photonic local density of states in graphene moiré superlattices

In this work we investigate the electromagnetic local density of states (LDOS) near a twisted bilayer graphene (TBG) deposited over a general isotropic substrate. The band structure of the TBG is calculated within a tight-binding framework, and then used to determine the TBG's conductivity. The latter presents a nontrivial dependence upon the angle of twist, which shows up in the LDOS, allowing for a moiré pattern-dependent quantum emission. For some specific twist angles we show that it is possible to either enhance or decrease the LDOS by an order of magnitude at selected frequencies when compared to the monolayer. Furthermore, this impressive variation is explained in terms of the presence/absence of well defined surface plasmon polaritons (SPPs). Altogether our findings demonstrate that TBG is an alternative, versatile material platform for controlling spontaneous emission and enhancing light-matter interactions, and pave the way for further studies and applications of quantum emission in the emerging class of two-dimensional moiré materials.

36 MATERIALS SCIENCE↗

Frequency selection and calibration of a water vapor radiometer

The calibration coefficients of existing water vapor radiometers are dependent upon meteorology profiles. This is shown to be due mainly to incorrect frequency pairs. By properly selecting an optimum frequency pair, the dependency can be reduced to a relatively small amount which can be handily adjusted by surface measurement alone. Hence, a universal calibration equation is applicable to all environmental conditions - site, seasonal and diurnal variations. Optimum frequency pairs are systematically searched. Error analysis indicates that calibration for the water vapor phase delay accurate to less than 2 cm is possible at all elevation angles greater than 15 degrees.

Wu, S. C.↗

Spaceborne weather radar

The present work on the development status of spaceborne weather radar systems and services discusses radar instrument complementarities, the current forms of equations for the characterization of such aspects of weather radar performance as surface and mirror-image returns, polarimetry, and Doppler considerations, and such essential factors in spaceborne weather radar design as frequency selection, scanning modes, and the application of SAR to rain detection. Attention is then given to radar signal absorption by the various atmospheric gases, rain drop size distribution and wind velocity determinations, and the characteristics of clouds, as well as the range of available estimation methods for backscattering, single- and dual-wavelength attenuation, and polarimetric and climatological characteristics.

Meneghini, Robert↗

Searching for Hyperspectral Optical Proxies to Aid Chesapeake Bay Resource Managers in the Detection of Poor Water Quality

Shellfish aquaculture is a growing industry in the Chesapeake Bay. As population grows near the coast, extreme weather events cause a greater volume of pollutant runoff from impervious surfaces and agricultural lands. Resource managers who monitor shellfish beds need reliable information on a variety of water quality indicators at higher frequency than is possible through field monitoring programs and at a higher level of detail than current satellite products can provide. Although many factors causing degraded water quality that can impact human health are not currently discernable by traditional multispectral techniques, hyperspectral imagery offers a new opportunity to detect phytoplankton communities associated with harmful algal blooms and biotoxin production. Together with resource managers in their routine monitoring of sites around the bay from small boats, we have been exploring remotely sensed optical proxies for the detection of harmful algal blooms and sewage. Early warning by remote sensing could guide sampling and improve the efficiency of shellfish bed closures, ultimately improving health outcomes for humans and animals. An extensive network of routine sampling by Chesapeake Bay Program managers makes this is an ideal location to develop and test future satellite data products to support management decisions. Next generation hyperspectral measurements from the future Plankton Aerosol Cloud ocean Ecosystem (PACE) mission at nearly daily frequency, combined with the potential of higher spatial resolution from the Surface Biology and Geology (SBG) observing system recommended in the recent Decadal Survey, along with high frequency observations from the newly selected Geostationary Littoral Imaging and Monitoring Radiometer (GLIMR) Earth Venture Instrument make this a critical time for defining the needs of the aquaculture and resource management community to save lives, time, and money.

Schollaert Uz, Stephanie↗

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗