Mechanical Environment Test Specifications Derived from Equivalent Energy in Fixed Base Modes with Frequency Shifts from Unit-to-Unit Variability.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Not Available
The outline for this presentation includes: Motivation, Test hardware and loads, Modal test of RC on 6 DOF test fixture, and Analysis--develop one specification accounting for unit-to-unit variability and develop independently tailored test specifications for unit-to-unit variability.
Explore the source record for details and available documents.
Cochannel interference reduction in FSK system by applying Hilbert transform techniques
Carbon dioxide oscillation frequency shift of rotation-vibration band, measuring variation dependence on pressure, discharge current and excitation
Uniaxial stress was used on Fe single crystals to induce muon precession frequency shifts. The frequency shift for a nominally pure Fe sample at 302K was -0.34 + or - .023 MHz per 100 microstrain along the 100 magnetization axis. This corresponds to a change of magnetic field at the muon of 25.1 + to 1.6G/100 magnetic moment. For an Fe (3wt%Si) single crystal the shifts were -0.348 + or - .008 MHz/100 magnetic moment. The agreement between the shifts for Fe and Fe(3wt%Si) shows the effect to be intrinsic to iron and not strongly impurity sensitive. These shifts and their temperature dependence (1/T) are dominated by the effect of strain inducted population shifts between crystallographically equivalent, but mgnetically inequivalent sites. Their magnitudes are in good agreement ith previous theoretical predictions and by previous extrapolation from calculations on Nb and V especially if both 4T(0) and 1T sites contribute comparably.
Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).
We calculate the effect of nonlinear interactions among solar acoustic modes upon the modal frequencies and energy loss rates (or line widths). The frequency shift for a radial p-mode of frequency 3 mHz is found to be about -0.5 microHz. The magnitude of nonlinear frequency shift increases more rapidly with frequency than the inverse mode mass (mode mass is defined as the ratio of energy in the mode to its surface velocity amplitude squared). This frequency shift is primarily due to nonresonant three-mode interactions and is dominated by high l surface gravity waves (f-modes) and p-modes. The line width of a radial p-mode of frequency 3 mHz, due to resonant nonlinear interactions, is about 0.3 microHz. This result is consistent with that of Kumar and Goldreich (1989). We also find, in agreement with these authors, that the most important nonlinear interactions of trapped p-modes involve f-modes and high-frequency p-modes (frequency greater than about 5 mHz) which propagate in the solar photosphere. Thus, using the arguments advanced by Kumar & Goldreich (1989), we conclude that nonlinear couplings cannot saturate the overstable solar p-modes at their small observed amplitudes. Both the nonlinear frequency shifts and line widths, at a fixed frequency, are proportional to the inverse of mode mass which for modes of degree greater than about 100 is approximately l(exp 0.8). Therefore, the frequency of an f-mode of l = 1000, due to nonlinear interactions, is decreased by approximately 0.4%.
There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.
Unified transponder system with hydrogen-maser oscillators at both stations can compensate for both motional and ionospheric components of Doppler shift. Appropriate choices of frequency shift in output of mixer m3. System exploits proportionality between dispersive component of frequency shift and reciprocal of frequency to achieve cancellation of dispersive component at output.
Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.
Temporal reflection is a process where an optical pulse reflects off a moving boundary with different refractive indices across it. In a dispersive medium, this process creates a reflected pulse with a frequency shift that changes its speed. Such frequency shifts depend on the speed of the moving boundary. In this work, we propose and experimentally show that it is possible to probe the trajectory of the boundary by measuring the frequency shifts while changing the initial delay between the incident pulse and the boundary. We demonstrate this effect by reflecting a probe pulse off a short soliton, acting as a moving boundary that decelerates inside a photonic crystal fiber because of intrapulse Raman scattering. We deduce trajectory of the soliton from the measured spectral data for the reflected pulse.