Search NASA⌕ Search

SEARCH · Search NASA

Results for “full width at half maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fine structure of the isovector giant dipole resonance in Nd 142 – 150 and Sm 152

Inelastic proton scattering at energies of a few hundred MeV and very-forward scattering angles including 0° has been established as a tool for the study of electric-dipole strength distributions in nuclei. The present work reports a systematic investigation of the chain of stable even-mass Nd isotopes representing a transition from spherical to quadrupole-deformed nuclei. Extraction of the equivalent photo-absorption cross sections and analysis of their fine structure in the energy region of the isovector giant dipole resonance (IVGDR). Method: Proton inelastic scattering reactions of 200 MeV protons were measured at the iThemba Laboratory for Accelerator Based Sciences in Cape Town, South Africa. The scattering products were momentum-analyzed by the K600 magnetic spectrometer positioned at θ Lab = 0°. Using dispersion-matching techniques, energy resolutions of ΔE ≈ 40–50 keV (full width at half maximum) were obtained. After subtraction of background and contributions from other multipoles, the spectra were converted to photoabsorption cross sections using the equivalent virtual-photon method. Wavelet-analysis techniques are used to extract characteristic energy scales of the fine structure of the IVGDR from the experimental data. Fine structure of the IVGDR is observed even for the most deformed nuclei studied. Comparisons between the extracted experimental energy scales and those energy scales obtained from the quasiparticle-phonon model (QPM) and Skyrme separable random phase approximation (SSRPA) predictions provide insight into the role of different giant-resonance damping mechanisms. It can be seen that the scales in the spherical and most likely also in the deformed nuclei mainly result from the fragmentation of the one-particle-one-hole (1p1h) strength into several dominant transitions serving as doorway states. In cases where calculations beyond the 1p1h level are available, some impact of the spreading due to coupling of the two-particle-two-hole (2p2h) states to the 1p1h doorway states is observed. New virtual-photon absorption data for the chain of stable Nd isotopes and 152 Sm are presented, with a focus on the phenomenon of nonstatistical cross-section fluctuations, referred to as fine structure, in the energy region of the IVGDR. The wavelet-analysis techniques used allowed for the features of the fine structure to be quantified in the form of characteristic scales. Finally, comparisons between experimental results and model predictions indicate that Landau damping seems to be the main source of the fine structure in both the spherical and deformed nuclei, but calculations including 2p2h degrees of freedom would be beneficial to confirm this for the deformed cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the lineshape of the χ c1 (3872) state

A study of the lineshape of the χ c1 (3872) state is made using a data sample corresponding to an integrated luminosity of 3 fb –1 collected in pp collisions at center-of-mass energies of 7 and 8 TeV with the LHCb detector. Candidate χ c1 (3872) and ψ(2S) mesons from b-hadron decays are selected in the J/ψπ + π – decay mode. Describing the lineshape with a Breit-Wigner function, the mass splitting between the χ c1 (3872) and ψ(2S) states, Δm, and the width of the χ c1 (3872) state, Γ BW , are determined to be Δm=185.598 ± 0.067 ± 0.068 MeV, Γ BW = 1.39 ± 0.24 ± 0.10 MeV, where the first uncertainty is statistical and the second systematic. Using a Flatté-inspired model, the mode and full width at half maximum of the lineshape are determined to be mode = 3871.69+0.00+0.05 – 0.04–0.13 MeV, FWHM=0.22 +0.07+0.11–0.06–0.13 MeV. An investigation of the analytic structure of the Flatté amplitude reveals a pole structure, which is compatible with a quasibound D 0 D¯ *0 state but a quasivirtual state is still allowed at the level of 2 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic Population Transfer via Impulsive Stimulated X-Ray Raman Scattering with Attosecond Soft-X-Ray Pulses

Free electron lasers provide a source of X-ray pulses short enough and intense enough to drive nonlinearities in molecular systems. Impulsive interactions driven by these X-ray pulses provide a way to create and probe valence electron motions with high temporal and spatial resolution. Observing these electronic motions is crucial to understand the role of electronic coherence in chemical processes. A simple nonlinear technique for probing electronic motion, impulsive stimulated X-ray Raman scattering (ISXRS), involves a single impulsive interaction to produce a coherent superposition of electronic states. In this work, we demonstrate electronic population transfer via ISXRS using broad bandwidth (5.5 eV full width at half maximum) attosecond X-ray pulses produced by the Linac Coherent Light Source (LCLS). The impulsive excitation is resonantly enhanced by the oxygen 1s → 2π* resonance of nitric oxide (NO), and excited state neutral molecules are probed with a time-delayed UV laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of van der Waals phonons in the single-layer cuprate ( Bi , Pb ) 2 ( Sr , La ) 2 CuO 6 + δ

Interlayer van der Waals (vdW) coupling is generic in two-dimensional materials such as graphene and transition-metal dichalcogenides, which can induce very low-energy phonon modes. Using high-resolution inelastic hard x-ray scattering, we uncover the ultralow energy phonon mode along the Cu-O bond direction in the high- T c cuprate (Bi,Pb) 2 (Sr,La) 2 ⁢CuO 6+$\delta$ (Bi2201). The energy and full-width half-maximum (FWHM) of these modes are independent of temperature, while their intensity decreases with doping in accordance with an increasing c -axis lattice parameter. Here, we compare the experimental results to first-principles density functional theory simulations and identify the observed mode as a van der Waals phonon, which arises from the shear motion of the adjacent Bi-O layers. This shows that Bi-based cuprate has vibrational properties similar to graphene and transition-metal dichalcogenides, which can be exploited to engineer novel heterostructures.

36 MATERIALS SCIENCE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invariant Features for Accurate Predictions of Quantum Chemical UV-vis Spectra of Organic Molecules

Including invariance of global properties of a phys-ical system as an intrinsic feature in graph neural networks (GNNs) enhances the model's robustness and generalizability and reduces the amount of training data required to obtain a desired accuracy for predictions of these properties. Existing open source GNN libraries construct invariant features only for specific GNN architectures. This precludes the generalization of invariant features to arbitrary message passing neural network (MPNN) layers which, in turn, precludes the use of these libraries for new, user-specified predictive tasks. To address this limitation, we implement invariant MPNNs into the flexible and scalable HydraGNN architecture. HydraGNN enables a seamless switch between various MPNNs in a unified layer sequence and allows for a fair comparison between the predictive performance of different MPNNs. We trained this enhanced HydraGNN archi-tecture on the ultraviolet-visible (UV-vis) spectrum of GDB-9 molecules, a feature that describes the molecule's electronic exci-tation modes, computed with time-dependent density functional tight binding (TD-DFTB) and available open source through the GDB-9-Ex dataset. We assess the robustness (i.e., accuracy and generalizability) of the predictions obtained using different invariant MPNNs with respect to different values of the full width at half maximum (FWHM) for the Gaussian smearing of the theoretical peaks. Our numerical results show that incorporating invariance in the HydraGNN architecture significantly enhances both accuracy and generalizability in predicting UV-vis spectra of organic molecules.

Baker, Justin↗

Filtered Backprojection in Compton Imaging using a Spherical Harmonic Wiener Filter with Pixelated CdZnTe

Filtered backprojection is an image reconstruction technique for Compton imaging that provides reasonably high resolution at much lower computational costs when compared to iterative methods. Here, this work applies a Wiener filter that has been derived for spherical harmonics on Compton imaging using the OrionUM pixelated CdZnTe imaging-spectrometer. To regularize the filter, an investigation is made into the power spectral density of the signal and noise to develop an appropriate spectral signal-to-noise ratio model for the restoration process. Experimental measurements were conducted with two 228Th sources placed 30° apart. The resulting filtered image of the two sources have an average full-width-at-half-maximum (FWHM) of 9.8° or 7.5° when using a mean squared error and structural similarity optimization approach respectively; an improvement from the 29.0° FWHM image when using simple backprojection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Firm spin and parity assignments for high-lying, low-spin levels in stable Si isotopes

A natural silicon target was investigated in a nat Si(γ,γ') photon-scattering experiment with fully linearly-polarised, quasi-monochromatic γ rays in the entrance channel. The mean photon energies used were < E γ >= 9.33, 9.77, 10.17, 10.55, 10.93, and 11.37 MeV, and the relative energy spread (full width at half maximum) of the incident beam was ΔE γ /< E γ >≈ 3.5–4 %. The observed angular distributions for the ground-state decay allow firm spin and parity assignments for several levels of the stable even-even silicon isotopes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser-Induced Plasmas of Plutonium Dioxide in a Double-Walled Cell

Plutonium research has been stifled by the significant number of administrative controls and safety procedures, space and instrumentation limitations in radiological gloveboxes, and the potential for personnel and equipment contamination. To address the limited number of spectroscopic studies in Pu-bearing compounds in the current scientific literature, this work presents the use of double-walled cells (DWCs) in “clean” buildings/laboratories as an alternative to research in radiological gloveboxes. This study reports the first laser-induced breakdown spectroscopy (LIBS) experiments of a PuO 2 pellet contained within a DWC, where the formation of elemental (atomic and ionic) species as well as the evolution from elemental to molecular products (Pu x O y ) was measured. Raman spectroscopy was also used to characterize the surface of the ablated pellet and the particulates deposited on the window of the inner cell. The full width half-maximum of the T 2g band enabled us to obtain an estimate of the temperature at the pellet surface after the ablation pulse and the particulates based on the crystal lattice disorder. Particulates deposited on the window of the DWC during laser ablation were characterized using scanning electron microscopy, where molten irregular particulates and spheroids were observed. This exciting research conducted in a DWC describes our initial attempts to incorporate LIBS in the arsenal of spectroscopic tools for nuclear forensics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amorphous silicon carbide high contrast gratings as highly efficient spectrally selective visible reflectors

We report spectrally selective visible wavelength reflectors using hydrogenated amorphous silicon carbide (a-SiC:H) as a high index contrast material. Beyond 610nm and through the near infrared spectrum, a-SiC:H exhibits very low loss and exhibits an wavelength averaged index of refraction of n = 3.1. Here we design, fabricate, and characterize such visible reflectors using a hexagonal array of a-SiC:H nanopillars as wavelength-selective mirrors with a stop-band of approximately 40 nm full-width at half maximum. The fabricated high contrast grating exhibits reflectivity R >94% at a resonance wavelength of 642nm with a single layer of a-SiC:H nanopillars. The resonance wavelength is tunable by adjusting the geometrical parameters of the a-SiC:H nanopillar array, and we observe a stop-band spectral center shift from 635 nm up to 642 nm. High contrast gratings formed from a-SiC:H nanopillars are a promising platform for various visible wavelength nanophotonics applications.

Bauser, Haley C.↗

Dotted-line FLEET for two-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) is a powerful unseeded velocimetry technique typically used to measure one component of velocity along a line, or two or three components from a dot. In this Letter, we demonstrate a dotted-line FLEET technique which combines the dense profile capability of a line with the ability to perform two-component velocimetry with a single camera on a dot. Our set-up uses a single beam path to create multiple simultaneous spots, more than previously achieved in other FLEET spot configurations. We perform dotted-line FLEET measurements downstream of a highly turbulent, supersonic nitrogen free jet. Dotted-line FLEET is created by focusing light transmitted by a periodic mask with rectangular slits of 1.6 × 40 mm 2 and an edge-to-edge spacing of 0.5 mm, then focusing the imaged light at the measurement region. Up to seven symmetric dots spaced approximately 0.9 mm apart, with mean full-width at half maximum diameters between 150 and 350 µm, are simultaneously imaged. Both streamwise and radial velocities are computed and presented in this Letter.

47 OTHER INSTRUMENTATION↗

Super-resolution demodulation for fiber sensor arrays based on the MUSIC algorithm

This paper studies the use of MUltiple SIgnal Classification (MUSIC) as a super-resolution algorithm to improve demodulation results for intrinsic Fabry–Perot interferometer (IFPI) sensor arrays. Through distinction between noise and signal subspaces in an observation matrix, this paper shows that a 38-fold improvement in the full width at half maximum (FWHM) estimation of IFPI optical path differences (OPD) can be achieved using this algorithm. Based on this improved method, this paper demonstrates that a tunable laser with a 1.3-nm tuning range can achieve the same sensor demodulation performance as a tunable laser with a 50-nm tuning range if a conventional Fourier transform-based algorithm is used. This paper presents a new approach to analyzing optical signals produced by multiple multiplexed interferometers with similar OPDs with potential applications for both single-mode and multiple-mode devices.

Li, Yuqi (ORCID:0000000291643663)↗

Few-femtosecond time resolution in optically pumped hard X-ray scattering at a free-electron laser

Capturing chemical dynamics in real time is a central goal of ultrafast science, necessitating measurements fast enough to track atomic motion on few-femtosecond timescales with high precision. We present time-resolved hard X-ray scattering that meets these criteria by combining 7 fs full-width at half maximum (FWHM) near-infrared laser pulses with sub10 fs FWHM hard X-ray pulses from a free-electron laser. Using heavy water’s electronic response to strong-field ionization as a benchmark, we achieve a sub-8 fs FWHM instrument response function. These optical pump X-ray probe measurements enable direct observation of chemical dynamics with angstrom spatial and few-fs temporal resolution.

Weckwerth, Eleanor [Stanford University, CA (Unite↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗

Examining ICARUS Cosmic Muon Signal Shapes

In the search for new physics, such as sterile neutrinos, we must compare our experimental data to the case where this new physics does not exist, which is provided by simulations. However, our detectors and simulations are not perfect, so we need to be able to differentiate imperfections in our simulations, detector effects, and unknown unknowns from new physics. Thus, we need to quantify ICARUS detector systematic uncertainties; in other words, we need to know how much difference between experiment and simulation we can expect due to only detector systematics, so when we see differences greater than this, we can be confident they are due to new physics. To calculate this uncertainty, we study the signals produced in ICARUS by cosmic muons, since these muons are well understood. Ideally, we want to fit these waveforms as Gaussians and compare the fits from experimental data to fits from simulations to calculate the uncertainties, but first, we need to know how accurately these curve s can be described by Gaussians. We examined the peak and the full width at half maximum (FHWM) of signals from simulations, and we produced plots of the distribution of peaks and FHWMs for these signals. We further studied how the peaks and FHWMs varied depending on where the signal came from in the detector. Ultimately, by comparing the actual distribution of peaks and FHWMs to the distribution predicted by the Gaussian fits, we hope to determine how well these signals can be described as Gaussians.

Patino, Nicolas↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset [Slides]

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Six csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database. [Isotope]_provenance Details on the csv data provider, including laboratory and contract information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗