Search NASA⌕ Search

SEARCH · Search NASA

Results for “gated imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

Chemical Imaging for In Situ Detection and Discrimination of Aquatic Toxins Targeting Voltage Gated Sodium Channels

Biologically derived neurotoxins from cyanobacteria and algae impact environmental resources in addition to being considered a potential biological threat to human and animal health. Activity based assays are essential to detecting and responding to toxic neurotoxin events either naturally occurring or deliberate. Two toxins of interest include saxitoxin and brevetoxin. These toxins bind to and alter the function of voltage-gated sodium channels (NaV channels) which are essential for generating cell membrane action potential. We report the development and refinement of a System for Analysis at Liquid Vacuum Interface (SALVI) to assess the functional activity of saxitoxin and brevetoxin. This approach utilizes a vacuum-compatible microfluidic reactor that permits analysis at the liquid vacuum interface of human derived cells with a neurotoxin of interest in a biologically relevant environment.

54 ENVIRONMENTAL SCIENCES↗

Quantum graph learning and algorithms applied in quantum computer sciences and image classification

Graph and network theory play a fundamental role in quantum computer sciences, including quantum information and computation. Random graphs and complex network theory are pivotal in predicting novel quantum phenomena, where entangled links are represented by edges. Quantum algorithms have been developed to enhance solutions for various network problems, giving rise to quantum graph computing and quantum graph learning (QGL). Here, in this review, we explore graph theory and graph learning methods as powerful tools for quantum computers to generate efficient solutions to problems beyond the reach of classical systems. We delve into the development of quantum complex network theory and its applications in quantum computation, materials discovery, and research. We also discuss quantum machine learning (QML) methodologies for effective image classification using qubits, quantum gates, and quantum circuits. Additionally, the paper addresses the challenges of QGL and algorithms, emphasizing the steps needed to develop flexible QGL solvers. This review presents a comprehensive overview of the fields of QGL and QML, highlights recent advancements, and identifies opportunities for future research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma flows during the ablation stage of an over-massed pulsed-power-driven exploding planar wire array

We characterize the plasma flows generated during the ablation stage of an over-massed exploding planar wire array, fielded on the COBRA pulsed-power facility (1 MA peak current, 250 ns rise time). The planar wire array is designed to provide a driving magnetic field (80–100 T) and current per wire distribution (about 60 kA), similar to that in a 10 MA cylindrical exploding wire array fielded on the Z machine. Over-massing the arrays enables continuous plasma ablation over the duration of the experiment without implosion. The requirement to over-mass on the Z machine necessitates wires with diameters of 75–100μm, which are thicker than wires usually fielded on wire array experiments. To test ablation with thicker wires, we perform a parametric study by varying the initial wire diameter between 33 and 100 μm. The largest wire diameter (100 μm) array exhibits early closure of the cathode-wire gap, while the gap remains open over the duration of the experiment for wire diameters between 33 and 75 μm. Laser plasma interferometry and time-gated extreme-ultraviolet (XUV) imaging are used to probe the plasma flows ablating from the wires. The plasma flows from the wires converge to generate a pinch, which appears as a fast-moving (V≈100kms−1) column of increased plasma density (n¯e≈2×1018cm−3) and strong XUV emission. Finally, we compare the results with three-dimensional resistive-magnetohydrodynamic (MHD) simulations performed using the code GORGON, the results of which reproduce the dynamics of the experiment reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precipitation measurements for earth-space communications: Accuracy requirements and ground-truth techniques

Rainfall which is regarded as one of the more important observations for the measurements of this most variable parameter was made continuously, across large areas and over the sea. Ships could not provide the needed resolution nor could available radars provide the needed breadth of coverage. Microwave observations from the Nimbus-5 satellite offered some hope. Another possibility was suggested by the results of many comparisons between rainfall and the clouds seen in satellite pictures. Sequences of pictures from the first geostationary satellites were employed and a general correspondence between rain and the convective clouds visible in satellite pictures was found. It was demonstrated that the agreement was best for growing clouds. The development methods to infer GATE rainfall from geostationary satellite images are examined.

Ippolito, L. J.↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗

Fluorescent toxins as ion channel activity sensors.

Voltage gated ion channels (VGICs) shape the electrical character of cells by undergoing structural changes in response to membrane depolarization. High-resolution techniques have provided a wealth of data on individual VGIC structures, but the conformational changes of endogenous channels in live cell membranes have remained unexplored. Here, we describe methods for imaging structural changes of voltage-gated K + channels in living cells, using peptidyl toxins labeled with fluorophores that report specific protein conformations. These Endogenous Voltage-sensor Activity Probes (EVAPs) enable study of both VGIC allostery and function in the context of endogenous live-cell membranes under different physiological states. In this chapter, we describe methods for the synthesis, imaging, and analysis of dynamic EVAPs, which can report K + channel activity in complex tissue preparations via 2-photon excitation microscopy, and environment-sensitive EVAPs, which report voltage-dependent conformational changes at the VGIC-toxin interface. The methods here present the utility of current EVAPs and lay the groundwork for the development of other probes that act by similar mechanisms. EVAPs can be correlated with electrophysiology, offering insight into the molecular details of endogenous channel function and allostery in live cells. This enables investigation of conformational changes of channels in their native, functional states, putting structures and models into a context of live-cell membranes. The expansive array of state-dependent ligands and optical probes should enable probes more generally for investigating the molecular motions of endogenous proteins.

Stewart, Robert↗

Event-driven charge-coupled device design and applications therefor

An event-driven X-ray CCD imager device uses a floating-gate amplifier or other non-destructive readout device to non-destructively sense a charge level in a charge packet associated with a pixel. The output of the floating-gate amplifier is used to identify each pixel that has a charge level above a predetermined threshold. If the charge level is above a predetermined threshold the charge in the triggering charge packet and in the charge packets from neighboring pixels need to be measured accurately. A charge delay register is included in the event-driven X-ray CCD imager device to enable recovery of the charge packets from neighboring pixels for accurate measurement. When a charge packet reaches the end of the charge delay register, control logic either dumps the charge packet, or steers the charge packet to a charge FIFO to preserve it if the charge packet is determined to be a packet that needs accurate measurement. A floating-diffusion amplifier or other low-noise output stage device, which converts charge level to a voltage level with high precision, provides final measurement of the charge packets. The voltage level is eventually digitized by a high linearity ADC.

Doty, John P.↗

Device-Level Multidimensional Thermal Dynamics With Implications for Current and Future Wide Bandgap Electronics

Researchers have been extensively studying wide-bandgap (WBG) semiconductor materials such as gallium nitride (GaN) with an aim to accomplish an improvement in size, weight, and power of power electronics beyond current devices based on silicon (Si). However, the increased operating power densities and reduced areal footprints of WBG device technologies result in significant levels of self-heating that can ultimately restrict device operation through performance degradation, reliability issues, and failure. Typically, self-heating in WBG devices is studied using a single measurement technique while operating the device under steady-state direct current measurement conditions. However, for switching applications, this steady-state thermal characterization may lose significance since the high power dissipation occurs during fast transient switching events. Therefore, it can be useful to probe the WBG devices under transient measurement conditions in order to better understand the thermal dynamics of these systems in practical applications. In this work, the transient thermal dynamics of an AlGaN/GaN high electron mobility transistor (HEMT) were studied using thermoreflectance thermal imaging and Raman thermometry. Also, the proper use of iterative pulsed measurement schemes such as thermoreflectance thermal imaging to determine the steady-state operating temperature of devices is discussed. These studies are followed with subsequent transient thermal characterization to accurately probe the self-heating from steady-state down to submicrosecond pulse conditions using both thermoreflectance thermal imaging and Raman thermometry with temporal resolutions down to 15 ns.

42 ENGINEERING↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

Differential phase acoustic microscope for micro-NDE

A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.

Waters, David D.↗

Pulsed laser synthesis of mesoporous metal chalcogenide thin films

Mesoporous films of the metal chalcogenide B-FeSe were grown on MgO substrates by KrF pulsed laser deposition (PLD) in an argon background. At 100 mTorr, gated intensified charge-coupled device imaging and ion probe measurements showed that the plasma plume responsible for crystal growth initially comprised three components, with distinct expansion velocities. Plume interactions with the substrate heater and ablation target gave rise to complex dynamics, including collisions between the charged leading edge—rebounding between the substrate and the target—and slower-moving species in the plume interior. Film growth was dominated by species with kinetic energies ≤0.5 eV/atom. X-ray reflectivity revealed that films grown in this environment—with a substrate temperature of 350 ° C, a laser fluence of 1.0 J cm −2 , and a 7.5 mm 2 spot area—formed a porous framework with 15% porosity. Atomic force microscopy showed surface features that suggest pore sizes below 100 nm. X-ray diffraction indicated that the porous films were epitaxial with respect to the substrate and likely grew by oriented-attachment of gas-phase molecular clusters or very small nanoparticles, in contrast to the conventional epitaxy of vacuum films from atomic constituents. The in-plane orientation of the mesoporous films was B-FeSe [100]||[110] MgO, attributed to the soft landing of pre-formed crystallites on the MgO substrates, where protruding Se rows of B-FeSe aligned with corrugations of the MgO surface. In conclusion, this work implies that growth of candidate electrocatalyst materials by PLD in inert gas background may allow mesoporous frameworks with a single crystallographic orientation that expose specific crystal facets for electrochemical reactions and active site engineering.

cluster epitaxy↗

Advances in mapping of x-ray emission from NIF hohlraums

A newly available ns-gated laser-entrance-hole (GLEH) imager in the National Ignition Facility provides a routine, non-perturbative measurement of hohlraum x-ray emission from inner and outer laser beam deposition regions. The GLEH records the x-ray flux integrated over complex interactions of various part of hohlraum plasma that evolves on a sub-nanosecond time scale. In using these images to unravel hohlraum physics, the first step is to pinpoint the origin inside the hohlraum of the observed x-ray image features. By mapping the hohlraum emission to the GLEH images using high-resolution simulations, one can interpret the GLEH images and gain insight into the hohlraum dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a Multi-Monochromatic X-ray Imager (MMI) for Kr K-shell line emission

We report the Multi-Monochromatic X-ray Imager (MMI) is a time-gated spectrometer used in implosion experiments at the OMEGA laser facility. From the data, electron temperature and density spatial distributions can be obtained at different implosion times. Previous MMI designs used Ar K-shell emission (3–6 keV) as a spectroscopic tracer and provided a spectral resolution of around 20 eV. However, Ar K-shell line emission becomes less useful at electron temperatures above 2 keV due to over-ionization. Kr K-shell (12–16 keV) has been shown to be an attractive alternative to diagnose hot implosion cores in recent publications. The purpose of this paper is to show a new point design that allows the MMI to detect this higher photon energy range with suitable spectral resolution. The algorithm used to find the optimal design couples a ray-tracing code and an exhaustive parameter space search. This algorithm may be useful as a tool to find optimal MMI designs for other purposes, i.e., other spectral regions for other spectroscopic tracers. So, the main change between the two designs is the replacement of the multi-layer mirror with a flat Bragg Ge (220) crystal. The final Kr K-shell MMI design has a photon energy range from 12 to 16.1 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduced thermal resistance of Al-rich AlGaN HEMTs via top-side diamond integration

We report back-end-of-line growth of nanocrystalline diamond (NCD) on ultrawide bandgap (UWBG) high Al content aluminum gallium nitride (AlGaN) channel high electron mobility transistors for thermal management. A thin (∼15 nm) silicon nitride (SiN x ) interlayer was deposited to protect the device surface before performing a low temperature (500 °C) NCD growth process in an attempt to protect the gates on these fully fabricated devices. Notably, atomic force microscopy showed that the maximum lateral grain size exceeded 300 nm even though the film thickness was ∼250 nm. Comparing electrical (DC) performance before and after NCD growth, the gate leakage increased by ∼10 2 after NCD growth. Despite the lower NCD growth temperature, intermixing of the Ni and Au was observed in the Schottky gate metal stack; however, we believe there is another mechanism, possibly hydrogen-related, that is responsible for the measured increase in gate leakage. Regarding thermal management, the device-level thermal resistance (quantified using the average gate temperature rise measured by thermoreflectance imaging) was reduced by 29% through the incorporation of the top-side diamond film. Using time-domain thermoreflectance, the thermal conductivity of the ≈250 nm thick NCD film was measured to be 45 ± 25 W m −1 K −1 . This is expected to be at least 5× greater than the thermal conductivity of the thin disordered AlGaN alloy. There could also be a coupled electrothermal component contributing to the reduced temperature rise from electric field spreading and consequent heat spreading. This study demonstrates a promising first step toward device-level thermal management of high power UWBG Al-rich AlGaN devices.

Lundh, James Spencer [U.S. Naval Research Laborato↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗