Search NASA⌕ Search

SEARCH · Search NASA

Results for “gated imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Image Processing Algorithms for Tuning Quantum Devices and Nitrogen-Vacancy Imaging

Semiconductor quantum dot devices can be challenging to configure into a regime where they are suitable for qubit operation. This challenge arises from variations in gate control of quantum dot electron occupation and tunnel coupling between quantum dots on a single device or across several devices. Furthermore, a single control gate usually has capacitive coupling to multiple quantum dots and tunnel barriers between dots. If the device operator, be it human or machine, has quantitative knowledge of how gates control the electrostatic and dynamic properties of multiqubit devices, the operator can more quickly and easily navigate the multidimensional gate space to find a qubit operating regime. We have developed and applied image analysis techniques to quantitatively detect where charge offsets from different quantum dots intersect, so called anticrossings. In this document we outline the details of our algorithm for detecting single anticrossings, which has been used to fine-tune the inter-dot tunnel rates for a three quantum dot system. Additionally, we show that our algorithm can detect multiple anticrossings in the same dataset, which can aid in the coarse tuning the electron occupation of multiple quantum dots. We also include an application of cross correlation to the imaging of magnetic fields using nitrogen vacancies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging Electrons in Two Dimensional Materials (Final report)

Two-dimensional (2D) materials have extraordinary characteristics that offer promising new approaches for science and technology. Electrons in graphene can move ballistically through a sheet, even though it is only a single atom thick. And transition metal dichalcogenide materials can be cleaved into 2D flakes of all types – metals, semiconductors, insulators, magnetic materials, and superconductors. To benefit from these discoveries, the science needs to be understood to transform 2D materials into useful new devices and systems. The evolution in time of atomic scale graphene structures has been studied in time with a transmission electron microscope (TEM), and ballistic transport of electrons in graphene was been imaged using a cooled scanning probe microscope (SPM), as well as electron motion in MoS 2 . Graphene is only one atom thick but is extremely strong, creating the opportunity to fabricate atomic scale structures in the lateral direction. Using an atomic resolution TEM, a suspended sheet of graphene can be shaped by a Si impurity atom on its surface that acts like a chisel to open up apertures, one atom at a time. The electrons in the TEM provide both the chiseling energy and the ability to image the results. Electrons and holes in graphene form a new type of electronic system with conical conduction and valence bands that meet at the Dirac point, with no energy gap. For moderate densities, the carriers form a Fermi liquid with ballistic transport over micron-scale distances. Using a cooled SPM the cyclotron orbit of electrons in graphene has been imaged. In the magnetic focusing regime, electrons leaving a point contact circle around and leave from a second point contact when the cyclotron diameter is equal to the contact spacing. The paths of electrons are focused - they enter at different angles but converge again at the exiting contact. When the SPM tip knocks an electron out of its orbit, an imaging signal is created. The ballistic motion of carriers in graphene opens the way for ballistic devices that manipulate beams of electrons and holes. Our collaborator Gil-Ho Lee, in Philip Kim's group, created a collimating contact by placing zig-zag absorbers on either side of entering electrons. Our cooled SPM was used to image the electron beam and determine its 9-degree halfwidth. By changing the gate voltage, a collimated beam of holes was also created, opening the way for colliding beam experiments. Coherent beams of carriers are desirable for quantum information processing. Via Andreev reflection, superconducting contacts can covert Cooper pairs in a superconductor to an ingoing and outgoing electrons and holes. Using our cooled SPM, Andreev reflection was imaged from a superconducting contact on a graphene device. Magnetic focusing was used to create an incoming beam of electrons and an outgoing beam of holes, detected by a third point contact. The images show a clear transition from normal reflection above the superconducting transition temperature to Andreev reflection as the device is cooled. Transition metal dichalcogenides offer a wide array of materials that can be exfoliated into ultrathin 2D sheets. A cooled SPM can be used to detect quantum dots as well as to image electron flow. The tip charge capacitively couples to electrons on the dot, acting as a gate to tune the dot conductance. Coulomb blockade peaks appear as a bullseye pattern in an SPM image as the tip is raster scanned above the dot. This approach was used to detect quantum dots in a MoS 2 channel as the carrier density was reduced and electrons pooled in low energy points. Through our DOE supported research, cooled SPM imaging has proven to be a very useful tool to uncover the motion of electrons and holes in the new quantum materials graphene and MoS 2 .

36 MATERIALS SCIENCE↗

Three-dimensional reconstruction of implosion stagnation in laser direct drive on OMEGA

Multidimensional effects on hot-spot formation must be considered to better understand the current limits on the performance of direct-drive inertial confinement fusion experiments on OMEGA with cryogenically layered solid deuterium–tritium targets. A comprehensive reconstruction effort has been established at the Laboratory for Laser Energetics to infer hot-spot and shell conditions at stagnation from a large collection of x-ray, neutron, and particle detectors along multiple lines of sight. Several time-gated and time-integrated x-ray imagers are being used to record the shape of the hot-spot plasma. A 3D hot-spot x-ray emission tomography technique has been developed to infer low-mode drive asymmetries from the hot-spot shape. A suite of neutron diagnostics is used to provide measurements of hot-spot flow velocity, ion temperature, and areal density. Here, the information obtained from the x-ray and neutron detectors will be combined into a coherent model of the shape of the hot spot and shell assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Distance-Weighted Graph Neural Networks on FPGAs for Real-Time Particle Reconstruction in High Energy Physics

Graph neural networks have been shown to achieve excellent performance for several crucial tasks in particle physics, such as charged particle tracking, jet tagging, and clustering. An important domain for the application of these networks is the FGPA-based first layer of real-time data filtering at the CERN Large Hadron Collider, which has strict latency and resource constraints. We discuss how to design distance-weighted graph networks that can be executed with a latency of less than one μs on an FPGA. To do so, we consider a representative task associated to particle reconstruction and identification in a next-generation calorimeter operating at a particle collider. We use a graph network architecture developed for such purposes, and apply additional simplifications to match the computing constraints of Level-1 trigger systems, including weight quantization. Using the hls4ml library, we convert the compressed models into firmware to be implemented on an FPGA. Performance of the synthesized models is presented both in terms of inference accuracy and resource usage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualizing the impact of quenched disorder on 2D electron Wigner solids

Electron Wigner solids (WSs) provide an ideal system for understanding the competing effects of electron–electron and electron–disorder interactions, a central unsolved problem in condensed matter physics. Progress in this topic has been limited by a lack of single-defect-resolved experimental measurements as well as accurate theoretical tools to enable realistic experiment/theory comparison. Here, in this study, we overcome these limitations by combining atomically resolved scanning tunnelling microscopy (STM) with neural-quantum-state quantum Monte Carlo (NQS-QMC) simulation of disordered 2D electron WSs to discover new disorder-induced physical regimes of correlated electron behaviour. STM was used to image the electron density (n e )-dependent evolution of electron WSs in gate-tunable bilayer MoSe 2 (BL-MoSe 2 ) devices with varying long-range (n LR ) and short-range (n SR ) disorder densities. These images were compared with NQS-QMC simulations using realistic disorder maps extracted from experiment, thus allowing the roles of different disorder types to be disentangled. We identify two distinct physical regimes for disordered electron WSs that depend on n SR . For n SR ≲ n e , the WS behaviour is dominated by long-range disorder and features extensive mixed solid–liquid phases, a new type of local re-entrant melting/crystallization and prominent Friedel oscillations. By contrast, when n SR ≫ n e , these features are suppressed and a more robust amorphous WS phase emerges that persists to higher n e , highlighting the importance of short-range disorder in this regime. Our work establishes a powerful framework for studying disordered quantum solids through a combined experimental–theoretical approach.

Ge, Zhehao [University of California, Berkeley, CA↗

Distinguishing Potassium Channel Resting State Conformations in Live Cells with Environment-Sensitive Fluorescence

Ion channels are polymorphic membrane proteins whose high-resolution structures offer images of individual conformations, giving us starting points for identifying the complex and transient allosteric changes that give rise to channel physiology. Here, we report live-cell imaging of voltage-dependent structural changes of voltage-gated Kv2.1 channels using peptidyl tarantula toxins labeled with an environment-sensitive fluorophore, whose spectral shifts enable identification of voltage-dependent conformation changes in the resting voltage sensing domain (VSD) of the channel. We synthesize a new environment-sensitive, far-red fluorophore, julolidine phenoxazone (JP) azide, and conjugate it to tarantula toxin GxTX to characterize Kv2.1 VSD allostery during membrane depolarization. JP has an inherent response to the polarity of its immediate surroundings, offering site-specific structural insight into each channel conformation. Using voltage-clamp spectroscopy to collect emission spectra as a function of membrane potential, we find that they vary with toxin labeling site, the presence of Kv2 channels, and changes in membrane potential. With a high-affinity conjugate in which the fluorophore itself interacts closely with the channel, the emission shift midpoint is 50 mV more negative than the Kv2.1 gating current midpoint. This suggests that substantial conformational changes at the toxin-channel interface are associated with early gating charge transitions and these are not concerted with VSD motions at more depolarized potentials. These fluorescent probes enable study of conformational changes that can be correlated with electrophysiology, putting channel structures and models into a context of live-cell membranes and physiological states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Density determination of the thermonuclear fuel region in inertial confinement fusion implosions

Understanding of the thermonuclear burn in an inertial confinement fusion implosion requires knowledge of the local deuterium–tritium (DT) fuel density. Neutron imaging of the core now provides this previously unavailable information. Two types of neutron images are required. The first is an image of the primary 14-MeV neutrons produced by the D +T fusion reaction. The second is an image of the 14-MeV neutrons that leave the implosion hot spot and are downscattered to lower energy by elastic and inelastic collisions in the fuel. These neutrons are measured by gating the detector to record the 6–12 MeV neutrons. Using the reconstructed primary image as a nonuniform source, a set of linear equations is derived that describes the contribution of each voxel of the DT fuel region to a pixel in the downscattered image. Using the measured intensity of the 14-MeV neutrons and downscattered images, the set of equations is solved for the density distribution in the fuel region. The method is validated against test problems and simulations of high-yield implosions. The calculated DT density distribution from one experiment is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-gated fast neutron transmission radiography system and method

The present disclosure relates to a time-gated fast neutron transmission radiography system and method. The system makes use of a pulsed neutron source for producing neutrons in a plurality of directions, with at least a subplurality of the neutrons being directed at an object to be imaged. The system also includes a neutron detector system configured to time-gate the detection of neutrons emitted from the pulsed neutron source to within a time-gated window.

Schmidt, Andrea↗

Real-time biomass feedstock particle quality detection using image analysis and machine vision

Abstract A common and costly challenge in the nascent biorefinery industry is the consistent handling and conveyance of biomass feedstock materials, which can vary widely in their chemical, physical, and mechanical properties. Solutions to cope with varying feedstock qualities will be required, including advanced process controls to adjust equipment and reject feedstocks that do not meet a quality standard. In this work, we present and evaluate methods to autonomously assess corn stover feedstock quality in real time and provide data to process controls with low-cost camera hardware. We explore the use of neural networks to classify feedstocks based on actual processing behavior and pixel matrix feature parameterization to further assess particle attributes that may explain the variable processing behavior. We used the pretrained ResNet neural network coupled with a gated recurrent unit (GRU) time-series classifier trained on our image data, resulting in binary classification of feedstock anomalies with favorable performance. The textural aspects of the image data were statistically analyzed to determine if the textural features were predictive of operational disruptions. The significant textural features were angular second moment, prominence, mean height of surface profile, mean resultant vector, shade, skewness, variation of the polar facet orientation, and direction of azimuthal facets. Expansion of these models is recommended across a wider variety of labeled feedstock images of different qualities and species to develop a more robust tool that may be deployed using low-cost cameras within biorefineries.

09 BIOMASS FUELS↗

A pulsed-power implementation of “Laser Gate” for increasing laser energy coupling and fusion yield in magnetized liner inertial fusion (MagLIF)

Magnetized Liner Inertial Fusion (MagLIF) at Sandia National Laboratories involves a laser preheating stage,where a few-ns laser pulse passes through a few-micron-thick plastic window to preheat gaseous fusion fuel contained within the MagLIF target. Interactions with this window reduce heating e ciency and mix window and target materials into the fuel. A recently proposed idea called \Laser Gate" involves removing the window well before the preheating laser is applied. In this article, we introduce experimental proof-of-principle results for a pulsed-power implementation of Laser Gate, where a thin current-carrying wire weakens the perimeter of the window, allowing the fuel pressure to push the window open and away from the preheating laser path. For this e ort, transparent targets were fabricated and a test facility capable of studying this version of Laser Gate was developed. A 12-frame bright- eld laser schlieren/shadowgraphy imaging system captured the window opening dynamics on microsecond timescales. The images exhibit that the window remains largely intact as it opens and detaches from the target. A column of escaping pressurized gas appears to prevent the detached window from inadvertently moving into the preheating laser path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic-scale imaging and charge state manipulation of NV centers by scanning tunneling microscopy

Nitrogen-vacancy (NV) centers in diamond are among the most promising solid-state qubit candidates, owing to their exceptionally long spin coherence times, efficient spin-photon coupling, room-temperature operation, and steadily advancing fabrication and integration techniques. Despite significant progress in the field, atomic-scale characterization and control of individual NV centers have remained elusive. In this work, we utilize a conductive graphene capping layer to enable direct imaging and manipulation of NV - defects via scanning tunneling microscopy (STM). By investigating over 40 individual NV - centers, we identify their spectroscopic signatures and spatial configurations. Our dI/dV conductance spectra reveal the ground state resonance approximately 300 meV below the Fermi level and density-of-states maps uncover a two-lobed wavefunction aligned along the [111] crystallographic direction. Remarkably, we demonstrate the ability to manipulate the charge state of the NV centers from NV - to NV 0 through STM tip-induced gating. This work represents a significant advance in the atomic-scale imaging, spectroscopic characterization, and charge-state manipulation of NV centers, potentially paving the way for future quantum device development.

Raghavan, Arjun [Univ. of Illinois at Urbana-Champ↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dam-Break Flow Measurements of Liquid–Granular Mixtures in a Channelized Reservoir

Dam-break flows of granular materials exhibit a complex non-Newtonian rheology, which is strongly influenced by various factors, such as the characteristics of the granular material, the degree of initial compaction, and saturation level of the granular matrix. Specially adapted nonintrusive techniques are required to investigate these flows in the laboratory. This paper investigated the nonintrusive technique of image analysis. The methodologies used in the measurement of bulk flow parameters, such as flow depth, front velocity, and flow rate, and the extraction of detailed flow characteristics such as velocity profiles, were discussed in the context of a series of granular dam-break flow experiments. These experiments were performed under three types of initial conditions: dry, saturated (water filling the pore space), and submerged (a layer of saturated granular material submerged under water) using four types of granular materials—PET pellets, crushed walnut shells, urea, and sand—with grain sizes ranging from 200 μm to 2.9 mm. High-speed cameras were used to capture the evolution and local properties of the flow, such as velocity fields using particle image velocimetry (PIV). Bulk properties of the flow were obtained by tracking the surface profile of the granular matrix and the water table. The extracted profiles were used to measure the evolution of the volume of the granular matrix and the fluid phase separately upstream and downstream of the gate, which allowed measuring the dilatancy (increase in pore space). The study showed that the image analysis techniques are versatile and can be adapted to measure different flow parameters in a variety of granular flows to better understand and analyze their complex behavior. Finally, the advantages and drawbacks of each image analysis technique were discussed and best-practice recommendations were provided.

42 ENGINEERING↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗