Dynamic and Regression Modeling of Ocean Variability in the Tide-Gauge Record at Seasonal and Longer Periods

Comparison of monthly mean tide-gauge time series to corresponding model time series based on a static inverted barometer (IB) for pressure-driven fluctuations and a ocean general circulation model (OM) reveals that the combined model successfully reproduces seasonal and interannual changes in relative sea level at many stations. Removal of the OM and IB from the tide-gauge record produces residual time series with a mean global variance reduction of 53%. The OM is mis-scaled for certain regions, and 68% of the residual time series contain a significant seasonal variability after removal of the OM and IB from the tide-gauge data. Including OM admittance parameters and seasonal coefficients in a regression model for each station, with IB also removed, produces residual time series with mean global variance reduction of 71%. Examination of the regional improvement in variance caused by scaling the OM, including seasonal terms, or both, indicates weakness in the model at predicting sea-level variation for constricted ocean regions. The model is particularly effective at reproducing sea-level variation for stations in North America, Europe, and Japan. The RMS residual for many stations in these areas is 25-35 mm. The production of "cleaner" tide-gauge time series, with oceanographic variability removed, is important for future analysis of nonsecular and regionally differing sea-level variations. Understanding the ocean model's strengths and weaknesses will allow for future improvements of the model.

Hill, Emma M.↗

Statistical Evaluation of Combined Daily Gauge Observations and Rainfall Satellite Estimations over Continental South America

This paper describes a comprehensive assessment of a new high-resolution, high-quality gauge-satellite based analysis of daily precipitation over continental South America during 2004. This methodology is based on a combination of additive and multiplicative bias correction schemes in order to get the lowest bias when compared with the observed values. Inter-comparisons and cross-validations tests have been carried out for the control algorithm (TMPA real-time algorithm) and different merging schemes: additive bias correction (ADD), ratio bias correction (RAT) and TMPA research version, for different months belonging to different seasons and for different network densities. All compared merging schemes produce better results than the control algorithm, but when finer temporal (daily) and spatial scale (regional networks) gauge datasets is included in the analysis, the improvement is remarkable. The Combined Scheme (CoSch) presents consistently the best performance among the five techniques. This is also true when a degraded daily gauge network is used instead of full dataset. This technique appears a suitable tool to produce real-time, high-resolution, high-quality gauge-satellite based analyses of daily precipitation over land in regional domains.

Vila, Daniel↗

Nanocomposite Strain Gauges Having Small TCRs

Ceramic strain gauges in which the strain-sensitive electrically conductive strips made from nanocomposites of noble metal and indium tin oxide (ITO) are being developed for use in gas turbine engines and other power-generation systems in which gas temperatures can exceed 1,500 F (about 816 C). In general, strain gauges exhibit spurious thermally induced components of response denoted apparent strain. When temperature varies, a strain-gauge material that has a nonzero temperature coefficient of resistance (TCR) exhibits an undesired change in electrical resistance that can be mistaken for the change in resistance caused by a change in strain. It would be desirable to formulate straingauge materials having TCRs as small as possible so as to minimize apparent strain. Most metals exhibit positive TCRs, while most semiconductors, including ITO, exhibit negative TCRs. The present development is based on the idea of using the negative TCR of ITO to counter the positive TCRs of noble metals and of obtaining the benefit of the ability of both ITO and noble metals to endure high temperatures. The noble metal used in this development thus far has been platinum. Combinatorial libraries of many ceramic strain gauges containing nanocomposites of various proportions of ITO and platinum were fabricated by reactive co-sputtering from ITO and platinum targets onto alumina- and zirconia-based substrates mounted at various positions between the targets.

Gregory, Otto↗

Thermal Properties of Microstrain Gauges Used for Protection of Lithium-Ion Cells of Different Designs

The purpose of this innovation is to use microstrain gauges to monitor minute changes in temperature along with material properties of the metal cans and pouches used in the construction of lithium-ion cells. The sensitivity of the microstrain gauges to extremely small changes in temperatures internal to the cells makes them a valuable asset in controlling the hazards in lithium-ion cells. The test program on lithium-ion cells included various cell configurations, including the pouch type configurations. The thermal properties of microstrain gauges have been found to contribute significantly as safety monitors in lithium-ion cells that are designed even with hard metal cases. Although the metal cans do not undergo changes in material property, even under worst-case unsafe conditions, the small changes in thermal properties observed during charge and discharge of the cell provide an observable change in resistance of the strain gauge. Under abusive or unsafe conditions, the change in the resistance is large. This large change is observed as a significant change in slope, and this can be used to prevent cells from going into a thermal runaway condition. For flexible metal cans or pouch-type lithium-ion cells, combinations of changes in material properties along with thermal changes can be used as an indication for the initiation of an unsafe condition. Lithium-ion cells have a very high energy density, no memory effect, and almost 100-percent efficiency of charge and discharge. However, due to the presence of a flammable electrolyte, along with the very high energy density and the capability of releasing oxygen from the cathode, these cells can go into a hazardous condition of venting, fire, and thermal runaway. Commercial lithium-ion cells have current and voltage monitoring devices that are used to control the charge and discharge of the batteries. Some lithium-ion cells have internal protective devices, but when used in multi-cell configurations, these protective devices either do not protect or are themselves a hazard to the cell due to their limitations. These devices do not help in cases where the cells develop high impedance that suddenly causes them to go into a thermal runaway condition. Temperature monitoring typically helps with tracking the performance of a battery. But normal thermistors or thermal sensors do not provide the accuracy needed for this and cannot track a change in internal cell temperatures until it is too late to stop a thermal runaway.

Jeevarajan, Judith↗

Thermistor Pressure Gauge Design

Thermistor pressure gauges are characterized by large pressure range, good accuracy and stability, fast measurement, insensitivity to over-pressure, negligible out-gassing, ease in cleaning, and physical and electrical simplicity and ruggedness. A number of excellent papers have been published describing these gauges. However, a detailed account of design procedure and characteristics for a specific gauge would eliminate much of the trial and error encountered in designing a gauge having prescribed range, sensitivity, and stability.

Flanick, A. P.↗

A 10-Year Comparison of Water Levels Measured with a Geodetic GPS Receiver Versus a Conventional Tide Gauge

A standard geodetic GPS receiver and a conventional Aquatrak tide gauge, collocated at Friday Harbor, Washington, are used to assess the quality of 10 years of water levels estimated from GPS sea surface reflections.The GPS results are improved by accounting for (tidal) motion of the reflecting sea surface and for signal propagation delay by the troposphere. The RMS error of individual GPS water level estimates is about 12 cm. Lower water levels are measured slightly more accurately than higher water levels. Forming daily mean sea levels reduces the RMS difference with the tide gauge data to approximately 2 cm. For monthly means, the RMS difference is 1.3 cm. The GPS elevations, of course, can be automatically placed into a well-defined terrestrial reference frame. Ocean tide coefficients, determined from both the GPS and tide gauge data, are in good agreement, with absolute differences below 1 cm for all constituents save K1 and S1. The latter constituent is especially anomalous, probably owing to daily temperature-induced errors in the Aquatrak tide gauge

Larson, Kristine M.↗

A Strain Gauge Monitor (SGM) for Continuous Valve Gape Measurements In Bivalve Molluscs in Response to Laboratory Induced Diel-Cycling Hypoxia and pH

An inexpensive, laboratory-based, strain gauge valve gape monitor (SGM) was developed to monitor the valve gape behavior of bivalve molluscs in response to diel-cycling hypoxia. A Wheatstone bridge was connected to strain gauges that were attached to the shells of oysters (Crassostrea virginica). The recorded signals allowed for the opening and closing of the bivalves to be recorded continuously over two-day periods of experimentally-induced diel-cycling hypoxia and diel-cycling changes in pH. Here, we describe a protocol for developing an inexpensive strain gauge monitor and describe, in an example laboratory experiment, how we used it to measure the valve gape behavior of Eastern oysters (C. virginica), in response to diel-cycling hypoxia and cyclical changes in pH. Valve gape was measured on oysters subjected to cyclical severe hypoxic (0.6 mg/L) dissolved oxygen conditions with and without cyclical changes in pH, cyclical mild hypoxic (1.7 mg/L) conditions and normoxic (7.3 mg/L) conditions. We demonstrate that when oysters encounter repeated diel cycles, they rapidly close their shells in response to severe hypoxia and close with a time lag to mild hypoxia. When normoxia is restored, they rapidly open again. Oysters did not respond to cyclical pH conditions superimposed on diel cycling severe hypoxia. At reduced oxygen conditions, more than one third of the oysters closed simultaneously. We demonstrate that oysters respond to diel-cycling hypoxia, which must be considered when assessing the behavior of bivalves to dissolved oxygen. The valve SGM can be used to assess responses of bivalve molluscs to changes in dissolved oxygen or contaminants. Sealing techniques to better seal the valve gape strain gauges from sea water need further improvement to increase the longevity of the sensors.

Porter, Elka T.↗

Impact of Gauge-Based Precipitation Corrections on the Skill of SMAP Level-4 Soil Moisture Estimates

The NASA Soil Moisture Active Passive (SMAP) mission provides observations of L-band (1.4 GHz) passive microwave brightness temperature (Tb) observations at a resolution of ~40 km globally every 2-3 days. These observations are routinely assimilated into the NASA Catchment land surface model to generate the Level-4 Soil Moisture (L4_SM) product, which provides global estimates of surface and root-zone soil moisture, soil temperature, and surface fluxes (among others) at 9-km, 3-hourly resolution with ~2.5-day latency. The Catchment land surface model in the L4_SM algorithm is driven with 0.25°, hourly surface meteorological forcing data from the NASA Goddard Earth Observing System (GEOS) "forward-processing" product. Outside of Africa and the high latitudes, the GEOS precipitation forcing is corrected using the Climate Prediction Center Unified (CPCU) gauge-based, 0.5°, daily precipitation product.Soil moisture estimates from the L4_SM product were previously shown to improve over land model-only estimates that do not benefit from the assimilation of Tb observations, thereby demonstrating the value of assimilating SMAP observations for soil moisture estimation. In this presentation, we further isolate the contribution of the gauge-based precipitation corrections to the skill of the L4_SM soil moisture estimates. Specifically, we compare the skill of the L4_SM soil moisture to that of separate model-only and assimilation estimates obtained without the benefit of the gauge-based precipitation corrections.Preliminary results suggest that the soil moisture skill added by the CPCU-based precipitation corrections primarily depends on the quality of the CPCU precipitation product and is greatest in regions where the CPCU gauge network is dense and reliable. Conversely, in regions where the CPCU product is known to be of poor quality, for example in central Australia, the assimilation of SMAP Tb observations provides the most benefit. The presentation will provide an in-depth evaluation of the soil moisture skill of the model-only and assimilation estimates vs. independent in situ and satellite measurements.

Reichle, Rolf↗

Laser Metrology Gauges for OSI

Heterodyne interferometers have been commercially available for many years. In addition, many versions have been built at JPL for various projects. This activity is aimed at improving the accuracy of such interferometers from the 1-30 nanometer level to the picometer level for use in the proposed OSI and SONATA missions as metrology gauges. In the null-gauge configuration, we obtained a precision of 0.6 picometers at time scales of 2,500 seconds. In the relative-gauge configuration, we obtained an accuracy of 3.5 picometers rms in vacuum at time scales of few minutes. An absolute gauge with an accuracy of 10 microns over a distance of 10 meters is under construction.

Gursel, Yekta↗

Alpha-particle Gas Pressure Gauge

Described are preliminary results obtained on a novel gas pressure gauge that operates between 0.1 and 1000 mb. This gauge uses a 1- micron Ci alpha particle source to ionize the gas in a small chamber with an electric field imposed between anode and cathode electrodes that drives positive ions to the cathode where they are collected electronically. This gauge could make Martian pressure measurements.

gas pressure sensor micro-pressure gauge alpha-par↗

Safety of hydrogen pressure gauges.

Study of the relative safety afforded an operator by various hydrogen-pressure gauge case designs. It is shown that assurance of personnel safety, should a failure occur, requires careful selection of available gauge designs, together with proper mounting. Specific gauge case features and mounting requirements are recommended.

Voth, R. O.↗

Gauge invariance, current conservation, and GIAO's

The well known relationship between gauge invariance and current conservation is exhibited within the usual quantum mechanical formalism. It is then shown that the use of gauge-invariant atomic orbitals (GIAO) does not necessarily lead to the expected current conservation. The reason is found to lie in the constrained nature of the gauge invariance which is provided by the use of GIAO's. It is concluded that this invariance is, of itself, no argument in favor of their use.

Epstein, S. T.↗

Gauge calibration by diffusion

Vacuum gage calibration by diffusing a known quantity of gas through a heated barrier into a gauge is examined. The gas flow raises the pressure in the gauge to known level and is then compared with the gauge's pressure reading.

Brock, F. J.↗

An improved thin-film gauge for shock-tube thermal studies.

An improved type of thin-film heat gauge has been developed and used to measure heat-transfer rates from a shock-heated plasma to the end wall of a shock tube. The gauge is a resistance thermometer consisting of a triple-layered sensor coated by a moderately thick film of SiO2. It was used to measure heat transfer from nonionized argon at temperatures of up to 16000 K. A marked increase in heat transfer at the onset of ionization near the wall indicates that the gauge can be used to obtain the contribution of free electrons to the thermal transport.

Willeke, K.↗

Gauge invariance, current conservation, and GIAO's.

The well-known relationship between gauge invariance and current conservation is exhibited within the usual quantum mechanical formalism. It is then shown that the use of Gauge Invariant Atomic Orbitals does not necessarily lead to the expected current conservation. The reason is found to lie in the constrained nature of the gauge invariance which is provided by the use of GIAO's. It is concluded that this invariance is, of itself, no argument in favor of their use.

Epstein, S. T.↗

Graphite ionization vacuum gauge

Triode gauge with electron source, electron collector, and positive ion collector made from either graphite or carbon material extends low-pressure ranges of existing gauges by changing only materials used in construction. Advantages of graphite gauge stem from physical properties of graphite (or carbon).

Beitel, G. A.↗

Design, development and manufacture of a breadboard radio frequency mass gauging system

The feasibility of the RF gauging mode, counting technique was demonstrated for gauging liquid hydrogen and liquid oxygen under all attitude conditions. With LH2, it was also demonstrated under dynamic fluid conditions, in which the fluid assumes ever changing positions within the tank, that the RF gauging technique on the average provides a very good indication of mass. It is significant that the distribution of the mode count data at each fill level during dynamic LH2 and LOX orientation testing does approach a statistical normal distribution. Multiple space-diversity probes provide better coupling to the resonant modes than utilization of a single probe element. The variable sweep rate generator technique provides a more uniform mode versus time distribution for processing.

Source record↗

Modified gauge for time-resolved skin-friction measurements

A new gauge for skin-friction measurements in turbulent flows involving a wire close to the surface and a second, flush-mounted film which serves as a constant temperature guard heater is described and evaluated. It is shown that a laminar calibration of the gauge applies to measurements in turbulent flow and that the frequency response of the gauge is appropriate for time-resolved data in such a flow. Initial results from a turbulent channel flow are presented.