Search NASA⌕ Search

SEARCH · Search NASA

Results for “gloves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

Bekdash, Omar↗

Analysis of Potential Glove-Induced Hand Injury Metrics During Typical Neutral Buoyancy Training Operations

Injuries to the hands are common among astronauts who train for extravehicular activity. When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of NASA's Lifetime Surveillance of Astronaut Health's injury database reveals that 76 percent of astronaut hand and arm injuries from training between 1993 and 2010 occurred either to the fingernail, finger crotch, metacarpophalangeal joint, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure forces acting on the fingers and hand within pressurized gloves and other variables such as skin temperature, humidity, and fingernail strain of a NASA crewmember during typical NBL (Neutral Buoyancy Laboratory) training activity. During the 5-hour exercise, the crewmember seemed to exhibit very large forces on some fingers, resulting in higher strain than seen in previous glove-box testing. In addition, vital information was collected on the glove cavity environment with respect to temperature and humidity. All of this information gathered during testing will be carried forward into future testing, potentially in glove-box- or 1G- (1 gravitational force) or NBL-suited environments, to better characterize and understand the possible causes of hand injury amongst NASA crew.

McFarland, Shane↗

Multifunctional textured graphene-based coatings on elastomeric gloves for chemical protection

Nanotechnology offers a variety of new tools for the design of next-generation personal protective equipment (PPE). One example is the use of two-dimensional materials as coatings that enhance the performance and ergonomics of elastomeric gloves designed to protect users from hazardous chemicals. Desirable features in such coatings may include molecular barrier function, liquid droplet repellency, stretchability for compatibility with the elastomer, breathability, and an ultrathin profile that preserves the user's manual dexterity and tactile sensation. The present work explores the potential of engineered graphene-based films with out-of-plane texturing as a novel platform to meet these multifold requirements. Graphene-based films in different formulations were fabricated from water-borne inks by vacuum filtration and solution casting methods on glove-derived nitrile rubber substrates. The various coatings were then subjected to tests of molecular permeation by model volatile organic compounds, droplet contact angle, breathability, and mechanical stability during stretching and solvent immersion. The films dramatically improve the barrier properties of glove-derived nitrile. The out-of-plane graphene texturing imparts stretchability through microscale folding/unfolding, while also enhancing droplet repellency in some cases through a lotus-like roughening effect. The combined results suggest that engineered textured graphene-based films are a promising platform for creating multifunctional coatings for a next generation of chemically protective gloves and other elastomer-based PPE.

36 MATERIALS SCIENCE↗

EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)

A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.

Coss, F. A.↗

Glove Box For Hazardous Liquids

Proposed glove box enables technician to handle hazardous liquids safely and to clean up quickly if spill occurs. Technician places hands and arms in gloves at port to manipulate materials within the box. Glove box includes hatch that seals off glove ports so box vented and purged when necessary.

Rossier, R. N.↗

Ballast system for maintaining constant pressure in a glove box

A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

Shlichta, Paul J.↗

The effect of pressure suit gloves on hand performance

The effects of pressure gloves on human hand capabilities is a major concern in the performance of extravehicular activity (EVA) for space maintenance and construction missions. The effects of EVA gloves on six hand performance domains was investigated in this NASA sponsored research. They were range of motion, strength, tactile perception, dexterity, fatigue, and comfort. All tests were designed to be performed in a glove box using the barehand as well as the glove at 0 and 4.3 pressure differentials. Ten subjects participated in the test in a repeated measures design. The results of the experiments are summarized in this paper.

O'Hara, John M.↗

NASA Research Announcement Phase 1 Report and Phase 2 Proposal for the Development of a Power Assisted Space Suit Glove Assembly

In July of 1996, ILC Dover was awarded Phase 1 of a contract for NASA to develop a prototype Power Assisted Space Suit glove to enhance the performance of astronauts during Extra-Vehicular Activity (EVA). This report summarizes the work performed to date on Phase 1, and details the work to be conducted on Phase 2 of the program. Phase 1 of the program consisted of research and review of related technical sources, concept brainstorming, baseline design development, modeling and analysis, component mock-up testing, and test data analysis. ILC worked in conjunction with the University of Maryland's Space Systems Laboratory (SSL) to develop the power assisted glove. Phase 2 activities will focus on the design maturation and the manufacture of a working prototype system. The prototype will be tested and evaluated in conjunction with existing space suit glove technology to determine the performance enhancement anticipated with the implementation of the power assisted joint technology in space suit gloves.

Cadogan, Dave↗

Ballast system for maintaining constant pressure in a glove box

A ballast system for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

Shlichta, Paul J.↗

The Effects of Extravehicular Activity (EVA) Glove Pressure on Hand Strength

The purpose of this study was to characterize hand strength, while wearing a Phase VI Extravehicular Activity (EVA) glove in an Extravehicular Mobility Unit (EMU) suit. Three types of data were collected: hand grip, lateral pinch, and pulp-2 pinch, wider three different conditions: bare-handed, gloved with no Thermal Micrometeoroid Garment (TMG), and glove with TMG. In addition, during the gloved conditions, subjects were tested when unpressurized and pressurized (43 psi). As a percentage of bare-hand strength, the TMG condition showed reduction in grip strength to 55% unpressurized and 46% pressurized. Without the TMG, grip strength increased to 66% unpressurized and 58% pressurized of bare-hand strength. For lateral pinch strength, the reduction in strength was the same for both pressure conditions and with and without the TMG, about 8.5% of bare-hand Pulp-2 pinch strength with no TMG showed an increase to 122% unpressurized and 115% pressurized of bare-hand strength. While wearing the TMG, pulp-2 pinch strength was 115% of bare-hand strength for both pressure conditions.

Mesloh, Miranda↗

The Effects of Extravehicular Activity (EVA) Glove Pressure on Tactility

The purpose of the current study was to quantify finger tactility, while wearing a Phase VI Extravehicular Activity (EVA) glove. Subjects were fully suited in an Extravehicular Mobility Unit (EMU) suit. Data was collected under three conditions: bare-handed, gloved at 0 psi, and gloved at 4.3 psi. In order to test tactility, a series of 30 tactile stimuli (bumps) were created that varied in both height and width. With the hand obscured, subjects applied pressure to each bump until detected tactilely. The amount of force needed to detect each bump was recorded using load cells located under a force-plate. The amount of force needed to detect a bump was positively related to width, but inversely related to height. In addition, as the psi of the glove increased, more force was needed to detect the bump. In terms of application, it was possible to determine the optimal width and height a bump needs to be for a specific amount of force applied for tactility.

Thompson, Shelby↗

Feasibility Assessment of an EVA Glove Sensing Platform to Evaluate Potential Hand Injury Risk Factors

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals that 58% of total astronaut hand and arm injuries from NBL training between 1993 and 2010 occurred either to the fingernail, MCP, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure force acting on the fingers and hand within pressurized gloves and other variables such as blood perfusion, skin temperature, humidity, fingernail strain, skin moisture, among others. Tasks were performed gloved and ungloved in a pressurizable glove box. The test demonstrated that fingernails saw greater transverse strain levels for tension or compression than for longitudinal strain, even during axial fingertip loading. Blood perfusion peaked and dropped as the finger deformed during finger presses, indicating an initial dispersion and decrease of blood perfusion levels. Force sensitive resistors to force plate comparisons showed similar force curve patterns as fingers were depressed, indicating suitable functionality for future testing. Strategies for proper placement and protection of these sensors for ideal data collection and longevity through the test session were developed and will be implemented going forward for future testing.

Reid, Christopher R.↗

Control of a Glove-Based Grasp Assist Device

A grasp assist system includes a glove and sleeve. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. The glove contains a tendon connected at a first end to the digit. The sleeve has an actuator assembly connected to a second end of the tendon and a controller in communication with the sensor. The controller includes a configuration module having selectable operating modes and a processor that calculates a tensile force to apply to the tendon for each of the selectable operating modes to assist the grasping force in a manner that differs for each of the operating modes. A method includes measuring the grasping force, selecting the mode, calculating the tensile force, and applying the tensile force to the tendon using the actuator assembly.

Bergelin, Bryan J↗

An advanced highly mobile 8 psig pressure glove

Description of the current status and design features of the advanced highly mobile 8-psig-pressure Phase-I and Phase-II gloves. Advantages and shortcomings of the Phase-I glove are reviewed. The Phase-II glove is expected to provide the nearly optimum mobility and tactility required for an effective extravehicular-activity system.

Elkins, W.↗

The WPI space glove design project

Worcester Polytechnic Institute (WPI) was one of four colleges and universities awarded NASA grants for student design and development of an improved glove for space suits. This paper traces the design, development and testing of the WPI prototype glove. Test results showed that the glove did not significantly limit hand and finger motion when pressurized at 8 psi, except in the spherical grip mode. This project demonstrated that problems originating from space technology provide excellent vehicles for student learning and can generate creative solutions.

Durgin, W. W.↗

The development of a test methodology for the evaluation of EVA gloves

This paper describes the development of a standardized set of tests designed to assess EVA-gloved hand capabilities in six measurement domains: range of motion, strength, tactile perception, dexterity, fatigue, and comfort. Based upon an assessment of general human-hand functioning and EVA task requirements, several tests within each measurement domain were developed to provide a comprehensive evaluation. All tests were designed to be conducted in a glove box with the bare hand as a baseline and the EVA glove at operating pressure.

O'Hara, John M.↗

Variable-Sweep Transition Flight Experiment (VSTFE): Stability code development and clean-up glove data analysis

The primary objective of the Variable Sweep Transition Flight Experiment (VSTFE) was to establish an improved swept wing transition criterion. The development of the Unified Stability System gave a way of quickly examining disturbance growth for a wide variety of laminar boundary layers. The disturbance growth traces shown are too scattered to define a transition criteria to replace the F-111 data band, which has been used successfully to design NLF gloves. Still, a careful review of the clean-up glove data may yield cases for which the transition location is known more accurately. Liquid crystal photographs of the clean-up glove show much spanwise variation in the transition front for some conditions, and this further complicates the analyses. Several high quality cases are needed in which the transition front is well defined and at a relatively constant chordwise station.

Rozendaal, Roger A.↗

Evaluation of hole sizes in structures requiring EVA services as a means to prevent gloved-hand finger entrapment

One of the concerns of Space Station designers was making sure that the suited crewmembers' gloved fingers are not trapped in the holes that may be present in the structures during EVA activities. A study was conducted on 11 subjects to determine the minimum and maximum possible hole sizes that would eliminate the possibility of finger entrapment. Subjects wore pressurized gloves and attempted to insert their fingers into holes of various sizes. Based on the experimental results, it is recommended that the smallest diameter should be less than 13.0 mm and the largest diameter should be greater than 35.0 mm in order to eliminate the possibility of finger entrapment while wearing gloves. It is also recommended that the current requirements specified by the MSIS-STD-3000 (Section 6.3.3.4) should be modified accordingly.

Rajulu, Sudhakar L.↗