Search NASA⌕ Search

SEARCH · Search NASA

Results for “grade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

In-situ fabrication of graded material with the application of a horizontal magnetic field during directional solidification

Highlights: • The horizontal magnetic field caused the migration of primary grains and the formation of graded material. • TEMF play a major effect on the formation of graded material. • The magnitude of TEMF increases with the increase of magnetic field intensity. • This work initiates a new method to prepare the “graded material” via an applied horizontal magnetic field. - Abstract: The present paper proposes a method of graded materials preparation under a low horizontal magnetic field during directional solidification. The external horizontal magnetic field was applied to the mushy zone of the directionally solidified Al-10 wt% Cu and Al-18 wt% Si samples, which was perpendicular to the growth direction. Experimental results demonstrate that the applied horizontal magnetic field produces a gradient size distribution of the primary α(Al) grains in Al-10 wt% Cu alloys and a gradient fraction distribution of primary Si particles in Al-18 wt% Si alloys. 3D numerical simulations indicate that the formation of graded structure should be attributed to the migration of primary phase driven by the thermoelectric magnetic force (TEMF). The formation of segregation channel should be attributed to the TEM convection (TEMC) in the mushy zone. Further, in situ synchrotron X-ray radiography observations of the initial transient of directional solidification show that the primary α(Al) phases were migrated approximately along the direction perpendicular to the magnetic field. These results suggest that the TEM effects can greatly change the growth of primary grains and the solidification structure, and the application of an external horizontal magnetic field would be beneficial to fabricate the graded material during directional solidification.

36 MATERIALS SCIENCE↗

Hybrid sensor for metal grade measurement of a falling stream of solid waste particles

Highlights: Black-Right-Pointing-Pointer A new sensor system is developed for metal grade measurement of falling bottom ash particles. Black-Right-Pointing-Pointer The system is hybrid, consisting of an optical and an electromagnetic sensor. Black-Right-Pointing-Pointer Grade of ECS concentrated bottom ash in 1-6 mm sieve size accurately measured up to 143 p/s feed rate. Black-Right-Pointing-Pointer Accuracy reached was 2.4% with respect to manual analysis. Black-Right-Pointing-Pointer Measures for elimination of both stationary and stochastic errors are discussed. - Abstract: A hybrid sensor system for accurate detection of the metal grade of a stream of falling solid waste particles is investigated and experimentally verified. The system holds an infrared and an electromagnetic unit around a central tube and counts all the particles and only the metal particles, respectively. The count ratio together with the measured average particle mass ratio (k) of non-metal and metal particles is sufficient for calculation of grade. The performance of the system is accurately verified using synthetic mixtures of sand and metal particles. Towards an application a case study is performed using municipal solid waste incineration bottom ash in size fractions 1-6 mm, which presents a major challenge for nonferrous metal recovery. The particle count ratio was inherently accurate for particle feed rates up to 13 per second. The average value and spread of k for bottom ash was determined as 0.49 {+-} 0.07 and used to calculate grade within 2.4% from the manually analysed grade. At higher feed rates the sensors start missing particles which fall simultaneously through the central tube, but the hybrid system still counted highly repeatable. This allowed for implementation of a count correction ratio to eliminate the stationary error. In combination with averaging in measurement intervals for suppression of stochastic variations the hybrid system regained its accuracy for particle feed rates up to 143 per second. This performance and its special design, intended to render it insensitive to external interference and noise when applied in an eddy current separator, make the hybrid sensor suitable for applications such as quality control and sensor controlled separation.

42 ENGINEERING↗

Fatigue Characterization of Functionally Graded Metallic Alloys

Functionally graded components exhibit spatial variations of mechanical properties in contrast with, and as an alternative to, purely homogeneous components. A large class of graded materials, however, are in fact mostly homogeneous materials with property variations (chemical or mechanical) restricted to a specific area or layer produced by applying for example a coating or by introducing sub-surface residual stresses. However, it is also possible to obtain graded materials with a smooth transition of mechanical properties along the entire component, for example in a 40 mm component. This is possible, for example, by using centrifugal casting technique or incremental melting and solidification technique. In this paper we will study fully metallic functionally graded components with a smooth gradient, focusing on fatigue crack propagation. Fatigue propagation will be assessed in the direction parallel to the gradation (in different homogeneous layers of the functionally graded component) to assess what would be fatigue crack propagation on the direction perpendicular to the gradation. Fatigue crack growth rate (standard mode I fatigue crack growth) will be correlated to the mode I stress intensity factor range. Other mechanical properties of different layers of the component (Young's modulus) will also be considered in this analysis. The effect of residual stresses along the component gradation on crack propagation will also be taken into account. A qualitative analysis of the effects of some important features, present in functionally graded materials, will be made based on the obtained results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multipoint Lax operator algebras: almost-graded structure and central extensions

Recently, Lax operator algebras appeared as a new class of higher genus current-type algebras. Introduced by Krichever and Sheinman, they were based on Krichever's theory of Lax operators on algebraic curves. These algebras are almost-graded Lie algebras of currents on Riemann surfaces with marked points (in-points, out-points and Tyurin points). In a previous joint article with Sheinman, the author classified the local cocycles and associated almost-graded central extensions in the case of one in-point and one out-point. It was shown that the almost-graded extension is essentially unique. In this article the general case of Lax operator algebras corresponding to several in- and out-points is considered. As a first step they are shown to be almost-graded. The grading is given by splitting the marked points which are non-Tyurin points into in- and out-points. Next, classification results both for local and bounded cocycles are proved. The uniqueness theorem for almost-graded central extensions follows. To obtain this generalization additional techniques are needed which are presented in this article. Bibliography: 30 titles.

97 MATHEMATICS AND COMPUTING↗

Strategies for Thinning Graded Buffer Regions in Metamorphic Solar Cells and Performance Tradeoffs

Compositionally graded buffers (CGBs) have enabled the development of inverted metamorphic (IMM) multijunction solar cells that contain three or more junctions and exhibit record efficiencies. Typically, the CGB is grown thick with a constant grading rate, because this is the most straightforward way to minimize the threading dislocation density (TDD) in device active regions. The CGB growth represents a significant expense, in terms of materials consumption and capital cost, however, hampering the economic viability of metamorphic devices. This work explores strategies for thinning Ga1-xInxP CGBs from GaAs to InP while minimizing performance loss, as evaluated by the open-circuit voltage (VOC) of ~0.74 eV Ga0.47In0.53As solar cells. Using the Ga1-xInxP CGB as a model, we demonstrate that slower grading is necessary in certain regions of the grade where dislocation nucleation rates are higher. Grading must be more gradual in these regions to suppress threading dislocation density. Grading rates can be increased in non-critical areas where dislocation nucleation is lower, permitting a thinner buffer. We demonstrate the relationship between VOC and TDD, establishing tradeoffs between thickness and performance. Through careful design, we demonstrate a CGB with a 40% thickness reduction (2 im) achieved with a VOC decrease of only 6.3% (21 mV).

14 SOLAR ENERGY↗

Theoretical investigation of variable periodicity (graded) multilayers for hard x ray applications

The objective of this research was to investigate the possibility of increasing the useful bandwidth of multilayer mirrors. Mirrors 'constructed' with non-periodically spaced reflecting surfaces were considered. These structures included depth-graded and laterally-graded mirrors as well as those with reflectors located via a log-periodic spacing rule. No enhancement of bandwidth resulted from simulations of simple versions of any of the three non-periodic mirrors. However, certain depth-graded structures did exhibit reflectances essentially the same as from uniform mirrors. Moreover, it was found that some control was possible regarding the location (with respect to energy) of the maximum reflectance peak. Effective bandwidth was increased when composite models were simulated. In two of the cases studied, bandwidth was enhanced by a factor of approximately 3. One model consisted of a depth-graded mirror constructed with three separately defined structures, or blocks. Each block consisted of two layer-pairs repeated three times. Then, the entire 18 layer-pair group was repeated several times. Simulation of this 3 block depth-graded configuration yielded three reflectance peaks, one representative of each depth-graded block. The other configurations resulting in enhanced bandwidth assumed independently constructed mirrors immediately adjacent to each other and sharing the same substrate. Reflectance peaks from each mirror appeared in the response. Both basic models show greatly enhanced effective bandwidths even though the reflectance curves appear as non-overlapping for these specific models. Additionally, these configurations are realizable. Details are contained in the section, DESIGN SIMULATIONS.

Kinney, Ralph A.↗

Higher-Order Theory for Functionally Graded Materials

This paper presents the full generalization of the Cartesian coordinate-based higher-order theory for functionally graded materials developed by the authors during the past several years. This theory circumvents the problematic use of the standard micromechanical approach, based on the concept of a representative volume element, commonly employed in the analysis of functionally graded composites by explicitly coupling the local (microstructural) and global (macrostructural) responses. The theoretical framework is based on volumetric averaging of the various field quantities, together with imposition of boundary and interfacial conditions in an average sense between the subvolumes used to characterize the composite's functionally graded microstructure. The generalization outlined herein involves extension of the theoretical framework to enable the analysis of materials characterized by spatially variable microstructures in three directions. Specialization of the generalized theoretical framework to previously published versions of the higher-order theory for materials functionally graded in one and two directions is demonstrated. In the applications part of the paper we summarize the major findings obtained with the one-directional and two-directional versions of the higher-order theory. The results illustrate both the fundamental issues related to the influence of microstructure on microscopic and macroscopic quantities governing the response of composites and the technologically important applications. A major issue addressed herein is the applicability of the classical homogenization schemes in the analysis of functionally graded materials. The technologically important applications illustrate the utility of functionally graded microstructures in tailoring the response of structural components in a variety of applications involving uniform and gradient thermomechanical loading.

Aboudi, Jacob↗

Grading NASA's Solar System Exploration Program: A Midterm Report

The Committee on Assessing the Solar System Exploration Program has reviewed NASA's progress to date in implementing the recommendations made in the National Research Council's (NRC's) solar system exploration decadal survey covering the period 2003-2013, New Frontiers in the Solar System, and in its Mars Architecture report, Assessment of NASA s Mars Architecture 2007-2016. The committee assessed NASA's progress with respect to each individual recommendation in these two reports, assigning an academic-style grade, explaining the rationale for the grade and trend, and offering recommendations for improvement. The committee generally sought to develop recommendations in cases where it determined that the grade, the trend, or both were worrisome and that the achievement of a decadal survey recommendation would require some kind of corrective action on NASA's part. This usually meant that the committee sought to offer a recommendation when the grade was a "C" or lower. However, the committee did offer recommendations in connection with some higher grades when it believed that minor corrective action was possible and desirable. More importantly, the committee did not offer recommendations for some of the activities given lower grades, particularly in the enabling technologies area (Chapter 6), because the committee determined that only the restoration of funding and the development of a strategic technology development program would solve these problems.

Source record↗

An Adaptation of ISO 11204 using Customized Correction Grades to Mitigate Ambient Noise Effects when Computing Sonic Boom Loudness Levels

A spectral-based correction adapted from ISO 11204 [1] is investigated here to mitigate the effects of ambient noise contamination of sonic booms recorded by noise monitors during field tests. The algorithm from sections 5.4.2 and 7 of ISO 11204 is customized using six nonstandard correction grades in addition to implementing the two standardized grades described in ISO 11204. The six nonstandard grades allow for more aggressive correction of the levels of the sonic boom spectrum when they are proximate to the ambient spectrum. Of the eight correction grades, the most aggressive custom correction grade, termed “Custom F” here, performed best under the conditions that were studied. Consequently, “Custom F” is recommended for use when processing in-field recordings of X-59 sonic booms. To evaluate the eight correction grades, mock X-59 acoustic recordings were generated using predicted ground-level X-59 sonic booms. These ground-level waveforms were created by Doebler [2] by propagating nearfield CFD solutions of the X-59 C612A configuration to the ground using PCBoom [3] (please see Acknowledgements and Refs. [4, 5, 2, 6]). To generate the mock acoustic recordings from those ground-level waveforms, they were further modified using turbulence filters developed during the NASA SonicBAT effort [7], post boom noise audio clips from the NASA SonicBAT tests [7], and ambient noise from the NASA QSF18 test [8, 9]. These mock acoustic recordings enabled evaluation of the ambient noise mitigation methods since the proper loudness levels of the X-59 waveforms in absence of ambient noise are known. Specifically, these known levels provide a benchmark against which the corrected loudness levels are compared, where the corrected loudness levels are computed when ambient noise is present within the waveforms. Importantly, similar analyses using in-field recordings are not possible since the proper loudness levels of the sonic boom waveforms in absence of ambient noise are unknowable when analyzing in-field recordings. Consequently, if additional analyses of ambient noise mitigation methods are needed, then use of mock recordings like those used here is recommended.

Sonic boom↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Graded approach for assessing digital system failure susceptibilities - 305

Owner/operators of nuclear plants must be able to identify and assess susceptibilities to digital system failures and unintended behaviors that could lead to plant system malfunctions, including common-cause failures (CCFs) of multiple controlled components that may impact overall plant safety. Nuclear plant designers and regulators often assess and manage potential failure modes by assuming the failure occurs and showing by analysis that the results are acceptable. In 2016 EPRI published a guideline on Methods for Assuring Safety and Dependability when Applying Digital Instrumentation and Control Systems (EPRI 3002005326), which takes a more holistic approach that considers digital system failure modes from the perspective of their impact on plant risk and includes a graded approach based on safety significance. This paper describes that graded approach. The methodology in EPRI 3002005326 systematically identifies potential I and C vulnerabilities that could lead to significant malfunctions of controlled components and systems, including common-cause failures (CCF), and discusses in detail methods to protect against them. It considers both preventive measures that reduce the likelihood of failures, and plant systems and features that mitigate the effects of component failures and misbehaviors. Coping analysis is then performed as appropriate to provide additional assurance of protection. The safety significance based graded approach is an important feature in that it can help users focus attention on overall plant safety, including potentially risk-significant scenarios that might not be considered in traditional safety analyses. The purpose is to help the user ensure that modifications to the I and C that could potentially be safety significant are treated appropriately and at the same time not waste valuable resources on excessive protection against changes that have little or no impact on safety. The graded approach allows the design engineer to tailor the rigor of the preventive, limiting, and mitigative measures commensurately with the effects the I and C modification has on overall plant safety. The graded approach focuses on safety significance impact, which is effectively a qualitative measure of the potential change in safety (or risk) caused by a proposed I and C modification, as compared to the I and C that is being replaced. Safety significance impact should not be confused with importance to safety or risk significance. It is possible that an upgrade to safety-related and/or risk-significant I and C systems may have little or no safety significant impact and vice versa. The approach considers three factors that influence the impact on safety significance of a proposed I and C modification: context, likelihood of failure, and consequences of failure. The most significant of the three factors is context - what the I and C is connected to, both directly and indirectly, including its potential effects on plant systems that respond to transients or accidents. The graded approach is particularly helpful in assessing potential CCFs resulting from digital I and C failures, and shows why the most problematic CCFs will be those that can affect multiple plant systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning-enhanced design for functionally graded auxetic lattices

Auxetic materials with counterintuitive negative Poisson’s ratio have been of significant interest due to potential applications across diverse engineering fields. Functionally grading such auxetics further enables customization of the structural response and harnesses the potential for multi-functional applications. However, a critical challenge in designing functionally graded lattices is to efficiently determine the spatial variation of the functional gradient and the corresponding geometric designs to achieve the desired response. In this paper, a highly efficient deep learning-based inverse design framework for functionally graded tetra-petal auxetics with spatially tailored properties is presented. This framework significantly improves the efficiency of tailoring functionally graded auxetics where many unit cells need to be tailor-designed. The graded tetra-petal auxetics obtained from the inverse design framework are additively manufactured and subjected to impact tests. The results show superior impact performance compared with uniform designs, demonstrating the effectiveness of the proposed inverse design framework, which can be inspirable to promote advanced structures/materials with enhanced impact resistance.

42 ENGINEERING↗

Estimating the reaction parameters of oil shale pyrolysis and oil shale grade using temperature transient analysis and inverse modeling

Grade of oil shale and reaction parameters of in-situ pyrolysis must be identified for the prediction of productivity before actual heating and production. Identification of oil shale grade and reaction parameters depends on laboratory experiments on core samples. However, laboratory-determined parameters can be different from those representing in-situ reservoir conditions. We use inverse modeling to determine oil shale grade and reaction parameters. The inversions are based on a forward model that simulates heat injection into a well. Temperature at the heating well is affected by a thermal skin effect as a result of a decrease of composite thermal conductivity around the heater due to the decomposition-induced porosity increase. Synthetic observations of heater temperature are generated from a forward simulation. Temperature difference and its derivative are used in synthetic inversions to estimate oil shale grade and parameters of active decomposition reactions with an error below 1%. Finally, the proposed methodology of inverse modeling is expected to successfully estimate the oil shale grade and reaction parameters without core sampling and subsequent surface experiments.

04 OIL SHALES AND TAR SANDS↗

FY17 Status Report on the Micromechanical Finite Element Modeling of Creep Fracture of Grade 91 Steel

Advanced reactors designed to operate at higher temperatures than current light water reactors require structural materials with high creep strength and creep-fatigue resistance to achieve long design lives. Grade 91 is a ferritic/martensitic steel designed for long creep life at elevated temperatures. It has been selected as a candidate material for sodium fast reactor intermediate heat exchangers and other advanced reactor structural components. This report focuses on the creep deformation and rupture life of Grade 91 steel. The time required to complete an experiment limits the availability of long-life creep data for Grade 91 and other structural materials. Design methods often extrapolate the available shorter-term experimental data to longer design lives. However, extrapolation methods tacitly assume the underlying material mechanisms causing creep for long-life/low-stress conditions are the same as the mechanisms controlling creep in the short-life/high-stress experiments. A change in mechanism for long-term creep could cause design methods based on extrapolation to be non-conservative. The goal for physically-based microstructural models is to accurately predict material response in experimentally-inaccessible regions of design space. An accurate physically-based model for creep represents all the material mechanisms that contribute to creep deformation and damage and predicts the relative influence of each mechanism, which changes with loading conditions. Ideally, the individual mechanism models adhere to the material physics and not an empirical calibration to experimental data and so the model remains predictive for a wider range of loading conditions. This report describes such a physically-based microstructural model for Grade 91 at 600° C. The model explicitly represents competing dislocation and diffusional mechanisms in both the grain bulk and grain boundaries. The model accurately recovers the available experimental creep curves at higher stresses and the limited experimental data at lower stresses, predominately primary creep rates. The current model considers only one temperature. However, because the model parameters are, for the most part, directly related to the physics of fundamental material processes, the temperature dependence of the properties are known. Therefore, temperature dependence can be included in the model with limited additional effort. The model predicts a mechanism shift for 600° C at approximately 100 MPa from a dislocation- dominated regime at higher stress to a diffusion-dominated regime at lower stress. This mechanism shift impacts the creep life, notch-sensitivity, and, likely, creep ductility of Grade 91. In particular, the model predicts existing extrapolation methods for creep life may be non-conservative when attempting to extrapolate data for higher stress creep tests to low stress, long-life conditions. Furthermore, the model predicts a transition from notchstrengthening behavior at high stress to notch-weakening behavior at lower stresses. Both behaviors may affect the conservatism of existing design methods.

36 MATERIALS SCIENCE↗

Microvascular invasion and grading in hepatocellular carcinoma: correlation with major and ancillary features according to LIRADS

Purpose: To assess major and ancillary parameters that could be correlated with Microvascular Invasion (MIV) and with histologic grade of HCC. Materials and methods: In this retrospective study, we assessed 62 patients (14 women–48 men; mean age, 63 years; range 38–80 years) that underwent hepatic resection for HCC. All patients were subject to Multidetector computed tomography (MDCT); 40 to Magnetic Resonance (MR) study. The radiologist assessed major and ancillary features according to LIRADS (v. 2018) and reported any radiological accessory findings if detected. Results: No major feature showed statistically significant differences and correlation with grading. Mean ADC value was correlated with grading and with MIV status. No major feature was correlated to MIV; progressive contrast enhancement and satellite nodules showed statistically different percentages with respect to the presence of MIV, so as at the monovariate correlation analysis, satellite nodules were correlated with the presence of MIV. At multivariate regression analysis, no factor proved to be strong predictors of grading while progressive contrast enhancement and satellite nodules were significantly associated with the MIV. Conclusion: Mean ADC value is correlated to HCC grading and MIV status. Progressive contrast enhancement and the presence of satellite nodules are correlated to MIV status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dose-Volume Relationship of Small Bowel Irradiation and Acute Grade 3 Diarrhea During Chemoradiotherapy for Rectal Cancer

Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volume parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Using Bevacizumab With Radiation Therapy and Temozolomide in Newly Diagnosed High-Grade Glioma

Introduction: Bevacizumab, a monoclonal antibody against vascular endothelial growth factor (VEGF), has shown promise in the treatment of patients with recurrent high-grade glioma. The purpose of this study is to test the feasibility of using bevacizumab with chemoradiation in the primary management of high-grade glioma. Methods and Materials: Fifteen patients with high-grade glioma were treated with involved field radiation therapy to a dose of 59.4 Gy at 1.8 Gy/fraction with bevacizumab 10 mg/kg on Days 14 and 28 and temozolomide 75 mg/m{sup 2}. Subsequently, bevacizumab 10 mg/kg was continued every 2 weeks with temozolomide 150 mg/m{sup 2} for 12 months. Changes in relative cerebral blood volume, perfusion-permeability index, and tumor volume measurement were measured to assess the therapeutic response. Immunohistochemistry for phosphorylated VEGF receptor 2 (pVEGFR2) was performed. Results: Thirteen patients (86.6%) completed the planned bevacizumab and chemoradiation therapy. Four Grade III/IV nonhematologic toxicities were seen. Radiographic responses were noted in 13 of 14 assessable patients (92.8%). The pVEGFR2 staining was seen in 7 of 8 patients (87.5%) at the time of initial diagnosis. Six patients have experienced relapse, 3 at the primary site and 3 as diffuse disease. One patient showed loss of pVEGFR2 expression at relapse. One-year progression-free survival and overall survival rates were 59.3% and 86.7%, respectively. Conclusion: Use of antiangiogenic therapy with radiation and temozolomide in the primary management of high-grade glioma is feasible. Perfusion imaging with relative cerebral blood volume, perfusion-permeability index, and pVEGFR2 expression may be used as a potential predictor of therapeutic response. Toxicities and patterns of relapse need to be monitored closely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Survival With Radiation Therapy in High-Grade Soft Tissue Sarcomas of the Extremities: A SEER Analysis

Purpose: The benefit of radiation therapy in extremity soft tissue sarcomas remains controversial. The purpose of this study was to determine the effect of radiation therapy on overall survival among patients with primary soft tissue sarcomas of the extremity who underwent limb-sparing surgery. Methods and Materials: A retrospective study from the Surveillance, Epidemiology, and End Results (SEER) database that included data from January 1, 1988, to December 31, 2005. A total of 6,960 patients constituted the study population. Overall survival curves were constructed using the Kaplan-Meir method and for patients with low- and high-grade tumors. Hazard ratios were calculated based on multivariable Cox proportional hazards models. Results: Of the cohort, 47% received radiation therapy. There was no significant difference in overall survival among patients with low-grade tumors by radiation therapy. In high-grade tumors, the 3-year overall survival was 73% in patients who received radiation therapy vs. 63% for those who did not receive radiation therapy (p < 0.001). On multivariate analysis, patients with high-grade tumors who received radiation therapy had an improved overall survival (hazard ratio 0.67, 95% confidence interval 0.57-0.79). In patients receiving radiation therapy, 13.5% received it in a neoadjuvant setting. The incidence of patients receiving neoadjuvant radiation did not change significantly between 1988 and 2005. Conclusions: To our knowledge, this is the largest population-based study reported in patients undergoing limb-sparing surgery for soft tissue sarcomas of the extremities. It reports that radiation was associated with improved survival in patients with high-grade tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗