Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A system definition study for the Advanced Meteorological Temperature Sounder (AMTS)

The functional requirements of Exhibit A (11) were used as the baseline for the conceptual design of a fixed grating out of plane multidetector spectrometer for the Space Shuttle application. Because the grating instrument would be large and the 28 element detector array would be difficult to cool radiatively from a free flying spacecraft and because increasing the spectral resolution of the grating instrument would be difficult in an instrument of reasonable size, a parallel study of a Nichelson interferometer spectrometer was undertaken. This type of instrument offers compact size, fewer detectors to cool, and the possibility of increased spectral resolution. The design and performance parameters of both the grating and interferometer approaches are described. The tradeoffs involved in comparing the two systems for sounding applications are discussed.

Source record↗

Curved Diffractive X-ray Optics for X-ray Astronomy

We report on a concept for curved diffractive X-ray optics (CDXO). CDXO would enable potential new optical designs for X-ray instruments, such as a two element spectrometer, in which the secondary element of an X-ray mirror pair is patterned with an X-ray grating. A two-element spectrometer design eliminates the grating assembly, resulting in decreased instrument mass and reduced power requirements. In addition, a two-element spectrometer may realize cost/schedule savings by eliminating a separate grating alignment effort, and yield increased effective area over three element designs. We present a raytrace concept study of a two-element spectrometer compact enough to fit within a sounding rocket payload. We also review the progress made in electron-beam lithography (EBL) techniques that would enable curved diffractive X-ray optics to be patterned, and outline a procedure by which the accuracy of the EBL patterning process can be measured interferometrically.

Casey T. DeRoo↗

SIRTF/IRS cryogenic grating drive mechanism (ARC second positioning at 4 K)

The requirements, design, and test results of a grating drive mechanism for the Infrared Spectrograph (IRS) science instrument on the proposed superfluid helium-cooled Space Infrared Telescope Facility (SIRTF) are described. The IRS grating drive mechanism, tested in the fall of 1989, satisfied all performance requirements in vacuum at 4 K. Measured mechanism performance included: 1.4 arc sec root-mean-square (rms) error positioning resolution; 2.2 arc sec rms position repeatability error, less than 10 millijoules/deg dissipated power; and 170 deg angular range of travel. Mechanisms that precisely position optical elements at very low cryogenic temperatures (at/below 4 K) are vital to the operating success of a number of proposed infrared scientific instruments like those in SIRTF.

Kubitschek, Michael J.↗

Aberrations of varied line-space grazing incidence gratings in converging light beams

Analyses of the imaging properties of several designs for varied-line space gratings in converging beams of light in grazing-incidence spectrometers are presented. An explicit model is defined for the case of a plane-reflection grating intercepting light that converges and is reflected to a stigmatic point associated with the zero-order image of the grating. Smooth spatial variation of the grating constant then permits aberration correction. The aberrations are expressed as polynomials in the grating lens coordinates using power series expansions. Application of the model is illustrated in terms of aberrations experienced with the short wavelength spectrometer on the EUVE satellite. Attention is given to straight and parallel in-plane grooves, curved groove in-plane designs and off-plane grooves. Aberrations due to dispersions and misalignment are also considered.

Hettrick, M. C.↗

Optical Waveguide Output Couplers Fabricated in Polymers

Waveguide output couplers fabricated in Norland Optical Adhesive (NOA) #81 and AMOCO Ultradel 9020D polyimide are investigated. The output couplers are implemented using periodic relief gratings on a planar waveguide. Design theory of the couplers is based on the perturbation approach. Coupling of light from waveguide propagation modes to output radiation modes is described by coupled mode theory and the transmission line approximation of the perturbed area (grating structure). Using these concepts, gratings can be accurately designed to output a minimum number of modes at desired output angles. Waveguide couplers were designed using these concepts. These couplers were fabricated and analyzed for structural accuracy, output beam accuracy, and output efficiency. The results for the two different materials are compared.

Watson, Michael D.↗

A Very High Resolution Mid Infrared Spectrograph for SOFIA

The purpose of this project was to study the design of a high resolution mid-infrared spectrograph for the SOFIA airborne observatory. The primary motivation for the construction and use of such an instrument is the study of vibrational transitions of molecules in molecular clouds, circumstellar inflows and outflows, and planetary atmospheres, which are blocked from ground-based observations by absorption by the Earth's atmosphere. The instrument design studied is a cross-dispersed grating spectrograph with several modes of operation giving spectral resolving powers of approximately 4000, 20,000, and 100,000. In the two lower resolution modes a single grating is used in a long-slit spectrograph. At high resolution that grating serves as the cross-disperser for a 1-m long echelon, a very coarsely and steeply ruled grating, diamond-machined in aluminum. Several design study tasks were carried out: 1. An optical and mechanical design was developed. It differed from the preliminary design by using a reflecting focal reducer in the fore-optics and by rearranging the echelon and cross-dispersing chambers to improve the efficiency of the long-slit modes. 2. A finite-element analysis of the dewar and echelon support structures was done. It led us to change the echelon support to improve its rigidity. 3. Further information was obtained which convinced us that Hyperfine Inc. was capable of diamond-machining the echelon. 4. Several possible vendors of readout electronics and software were identified. It was decided that it is more cost-effective to purchase these items rather than developing them ourselves. 5. Observing and calibration procedures were studied. we did not identify significant changes needed from procedures used previously. 6. Possible expansions of instrument capabilities, including wavelength coverage, were studied. It appears unlikely that the echelon will perform well at wavelengths shortward of 5 microns, but the spectral coverage could be extended longward of 28 microns with the use of an Si:Sb detector. No patentable inventions were made during this study. Based on this design study, a proposal was submitted to construct the instrument. It was chosen as one of the first-light instruments for SOFIA.

Lacy, John H.↗

Dispersion Leverage Coronagraph: a nulling coronagraph for use on primary objective grating telescopes

Here, we present the Dispersion Leverage Coronagraph (DLC), a variation of the Achromatic Interfero Coronagraph (AIC) that is designed for optical systems featuring large, dispersive primary objective gratings. DLC was originally designed for the Diffractive Interfero Coronagraph Exoplanet Resolver (DICER), a notional 20 m class infrared space telescope utilizing the enhanced one-dimensional angular resolution of large diffraction gratings to discover and characterize near-Earth exoplanets. Here we develop the theoretical foundation for DLC, and apply it to DICER as an example use case. We derive important properties of the DLC system, including focal plane transmission maps, stellar leakage, residual optical path difference tolerance, and pointing error/jitter considerations. Ultimately, we found that DLC effectively nulls an on-axis target across the entire spectrum in the focal plane, allowing for 2D/λ diffraction-limited imaging. It requires asymmetrical fine-guidance tolerances on pointing error/jitter. We work through a benchmark DICER design, explaining the need for a second disperser to reduce background from Zodiacal light, and showing that it could plausibly find and characterize ∼4 nearby, habitable exoplanets around Sun-like stars in a 7-year mission; about 30% of the habitable exoplanets within 8 pc were found in our simulation. The DLC may be useful for any application requiring extremely high-resolution, close companion spectroscopy.

AIC↗

Plasmon device design: Conversion from surface to junction plasmons with grating-couplers

Scaling calculations and numerical studies are used to show that grating couplers provide effective energy transfer between surface plasmons and slower modes localized in the tunnel diodes. Within first order perturbation theory in grating amplitude, 90% efficiency energy transfer occurs within micrometers for realistic structures and materials parameters. Scaling laws are derived. Seventy to 90% of the electromagnetic field energy is concentrated in the oxide layer of an MOM diode after the energy is distributed by longer range modes that have less than 0.1% overlap with the tunneling region. The mode conversion allows the requirements separation for energy transport and power production by inelastic tunneling.

Anderson, L. M.↗

The design and fabrication of a single leakage-channel grating coupler

The modeling and fabrication is described of waveguide grating couplers with out-coupling efficiencies into a single diffracted order nearing 100 pct. Termed Single Leakage Channel Grating Couplers (SLCGCs), these devices use a high reflectivity dielectric stack to reflect the out-coupled beam diffracted toward the substrate, back up into the air region where it constructively adds with the beam diffracted into the air region. Computer modeling shows that the branching ratio and the leakage rate can be independently controlled, and that the branching ratio is independent of grating depth and grating period. A SLCGC with a branching ratio of 97.1 pct. was fabricated using a combination of vacuum evaporation and wet chemical techniques.

Roncone, Ronald L.↗

Direct and Inverse Techniques of Guided-Mode Resonance Filters Designs

Guided-mode resonances arise in single or multilayer waveguides where one or more homogeneous layers are replaced by diffraction gratings (Fig. 1.) The diffractive element enables an electromagnetic wave incident on a waveguide grating to be coupled to the waveguide modes supportable by the structure in the absence of the modulation (i.e. the difference between the high and low dielectric constants of the grating) at specific values of the wavelength and incident angle. The periodic modulation of the guide makes the structure leaky, preventing sustained propagation of modes in the waveguide and coupling the waves out into the substrate and cover. As the wavelength is varied around resonance a rapid variation in the intensities of the external propagating waves occurs. By selecting a grating period small enough to eliminate the higher-order propagating waves, an increase in the zero-order intensities up to 100% can result. The pronounced frequency selectivity of guided-mode resonances in dielectric waveguide gratings can be applied to design high-efficiency reflection and transmission filters [1-3].

Tibuleac, Sorin↗

A high resolution echelle spectrometer for soft X-ray and EUV astronomy

A new design is presented for high resolution spectroscopy from 80 to 400 A. This design employs grazing incidence optics and variable line-spaced gratings to achieve high resolution. Unlike some previously proposed EUV echelles, this design employs straight groove planar gratings, which are a well-proven, easily manufactured design. The instrument delivers a peak resolution of 7500 and a peak effective area of 3 sq cm.

Green, James↗

Time-domain theory of transient heat conduction in the local limit

Ultrafast and nanoscale heat conduction demands a unified theoretical framework that rigorously bridges macroscopic transport equations with microscopic material properties derived from statistical physics. Existing empirical generalizations of Fourier's law often lack a solid microscopic foundation, failing to connect observed non-Fourier behavior with underlying atomic-scale mechanisms. In this work, we present a time-domain theory of transient heat conduction rooted in Zwanzig's statistical theory of irreversible processes. Central to this framework is the time-domain transport function $\overleftrightarrow{𝑍}$⁡(𝑡) defined through equilibrium time-correlation functions of heat fluxes. This function generalizes the conventional concept of steady-state thermal conductivity, governing the transition of conduction dynamics from onset second sound type wave propagation at finite speeds to diffusion-dominated behavior across broad temporal and spatial scales. Unlike phonon hydrodynamic models that rely on mesoscopic constructs such as phonon drift velocity, our approach provides a quantitative and microscopic description of intrinsic memory effects in transient heat fluxes and applies universally to bulk materials at any temperature or length scale. By integrating atomistic-scale first-principles calculations with continuum-level macroscopic equations, this framework offers a robust foundation for numerical simulations of transient temperature fields. Furthermore, it facilitates the interpretation and design of transient thermal grating experiments using nanometer-scale heat sources and ultrafast laser systems in the extreme ultraviolet and x-ray wavelength ranges, advancing our understanding of heat dissipation dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

Dispersive spectroscopy on AXAF

The designs of two transmission grating spectrometers and a Bragg crystal spectrometer that are being developed for the Advanced X-ray Astrophysics Facility (AXAF) are described. The gratings, which are composed of arrays of small facets mounted on plates which can be inserted immediately behind the AXAF telescope, divide the AXAF energy band (80 eV-10 keV) into three regions and attain very high resolving powers for point sources. The Bragg Crystal Spectrometer (BCS) is a focal plane instrument, in which X-rays that satisfy the Bragg law are reflected from a curved crystal which refocuses the beam onto an imaging detector. The BCS achieves the highest spectral resolutions of the AXAF spectrometers: for E values between 500 and 1600 eV, the FWHM of a narrow line is less than 1 eV.

Markert, T. H.↗

Color separation gratings

In this paper, we describe the theory, fabrication and test of a binary optics 'echelon'. The echelon is a grating structure which separates electromagnetic radiation of different wavelengths, but it does so according to diffraction order rather than by dispersion within one diffraction order, as is the case with conventional gratings. A prototype echelon, designed for the visible spectrum, is fabricated using the binary optics process. Tests of the prototype show good agreement with theoretical predictions.

Farn, Michael W.↗

Health Monitoring of RLV Airframe Structures

This final report is divided into three sections on health monitoring technologies: 1) Analysis of Optical Fiber Bragg Grating Sensor Data from Composite Wing Box Experiment; 2) Current Optical Fiber Bragg Grating Sensor Data Acquisition Design; and 3) Damages Identification of a Composite Plate by Prestack Reverse-Time Migration Technique. The report also includes an appendix, 'Group Velocities of Flexural Waves in a Composite Plate'.

Yuan, F. G.↗

New Convex Grating Types for Concentric Imaging Spectrometers

The properties of convex gratings fabricated by electron-beam lithography are investigated. Three grating types are shown. These gratings allow the optical designer to fully realize the considerable advantages of concentric spectrometer forms.

spectrometers concentric imaging electron beam↗