Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid life”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Optimal design and integration of decentralized electrochemical energy storage with renewables and fossil plants

Increasing renewable energy requires improving the electricity grid flexibility. Existing measures include power plant cycling and grid-level energy storage, but they incur high operational and investment costs. Using a systems modeling and optimization framework, we study the integration of electrochemical energy storage with individual power plants at various renewable penetration levels. Furthermore, our techno-economic analysis includes both Li-ion and NaS batteries to encompass different technology maturity levels. A California case-study indicates localized integration to be cost-effective for greater grid flexibility. Li-ion batteries can mitigate the residual demand fluctuations of small to medium-sized plants, while NaS batteries would be best-suited for larger storage with higher renewable penetration. Overall, the battery-enabled renewable integration could reduce the unmet grid demand by 75%, the renewable curtailment by 58%, and the CO 2 emission intensity by 16% while including the life cycle emissions of the battery and the renewable farm. Our scenario-based analysis also indicates that rather than replacing all fossil power plants, it is more economical to combine batteries and renewables with individual fossil plants to achieve a clean energy grid.

25 ENERGY STORAGE↗

Global urban growth between 1870 and 2100 from integrated high resolution mapped data and urban dynamic modeling

Long term, global records of urban extent can help evaluate environmental impacts of anthropogenic activities. Remotely sensed observations can provide insights into historical urban dynamics, but only during the satellite era. Here, we develop a 1 km resolution global dataset of annual urban dynamics between 1870 and 2100 using an urban cellular automata model trained on satellite observations of urban extent between 1992 and 2013. Hindcast (1870–1990) and projected (2020–2100) urban dynamics under the five Shared Socioeconomic Pathways (SSPs) were modeled. We find that global urban growth under SSP5, the fossil-fuelled development scenario, was largest with a greater than 40-fold increase in urban extent since 1870. The high resolution dataset captures grid level urban sprawl over 200 years, which can provide insights into the urbanization life cycle of cities and help assess long-term environmental impacts of urbanization and human–environment interactions at a global scale.

54 ENVIRONMENTAL SCIENCES↗

Predicting Power Outage During Extreme Weather with EAGLE-I and NWS Datasets

Extreme weather events, such as hurricanes, severe thunderstorms, and floods can significantly disrupt power grid systems, leading to electrical outages that result in inconvenience, economic losses, and life-threatening situations. There is a growing need for a robust and precise predictive model to forecast power outages, which will help prioritize emergency response before, during, and after extreme weather events. In this paper, we introduce machine-learning models that predict power outage risk at the state level during and after extreme weather events. We jointly utilized two publicly available datasets: the U.S. historical power outage data collected by the Environment for Analysis of Geo-Located Energy Information (EAGLE-I™) system, and the National Weather Service historical weather alert data sets. We highlight our initial result and discuss future work aimed at enhancing the model's robustness and accuracy for real-world applications.

Lee, Sangkeun (Matt)↗

Integration of Superconducting Magnetic Energy Storage (SMES) Systems Optimized with Second-Generation, High-Temperature Superconducting (2G-HTS) Technology with a Major Fossil-Fueled Asset

Utility companies and fossil fueled generation assets are seeking combinations of “hybrid energy storage” to allow power to be provided in advance of, and to otherwise complement, peaking natural gas-fired generation. American Maglev Technology of Florida Inc. (AMT) learned during the Phase I program based on interactions with NRG Energy (NRG) that energy storage such as superconducting magnetic energy storage (SMES) can qualify as a Black Start unit in most markets, ensuring orderly re-start of grid operations and fossil fueled power plants and serving as an important asset of hybrid energy storage technology. In conjunction with the University of Houston (UH), AMT and NRG are working together to scale up low-cost, high- efficiency, second-generation high-temperature superconducting (2G-HTS) technology for deployment across several markets, with a primary focus on the commercial development of utility grid-scale SMES (g-SMES) systems. Ultimately the program confirmed that the novel g-SMES design can meet the performance and financial requirements of the fossil power plant industry, while exhibiting continuous grid-voltage regulation; cost-effective, peak-hour energy storage with almost infinite life; increased input/output efficiency; and the capability to undergo millions of charging cycles, without degradation, representing a significant improvement over lithium ion and other conventional storage technologies. We believe wide scale deployment of this technology is feasible and practical when compared to the higher life cycle cost and relatively short lifespan of chemical batteries. Based on these findings, the future for deployment of SMES at many fossil-fueled power plants exceeding 100MW capability is bright. Further de-risking g-SMES technology would pave the way for the construction of a subscale prototype. Eventually, scaled-down versions of SMES are expected to be competitive with the multi-billion-dollar lithium-ion market for a wide range of commercial, industrial, and transportation uses. There is long-term potential for commercialization and widespread deployment of this disruptive technology, which would spawn a new worldwide supply chain and create domestic, high-tech manufacturing jobs in the green industry.

20 FOSSIL-FUELED POWER PLANTS↗

High-Reliability Systems and the Control of National Security Data and Information

High-reliability systems are characterized by catastrophic implications in the event of failure. These implications can include substantive damage to the environment, social order, and loss of life. Examples of high-reliability systems include nuclear submarines, nuclear reactors, the electric grid, and nuclear weapons. Due to the catastrophic implications of failure, there are heightened awareness and control mechanisms surrounding related data and information. However, defining the difference between data and information is often ambiguous across scholarly disciplines and in United States policy and legislation. For high-reliability systems, the implications of ambiguity between data and information may affect the security of United States interests and even cost lives. For security, data are raw facts or figures without context, while information is the compilation or articulation of data that forms context. Security depends on clarity in the differences between data and information and how to control them. Control is necessary to ensure that data and information are not unintentionally released to foreign governments, the public, or those without need-to-know. A primary concern in the practice of security is the control of data to avoid the unintended conversion to information. Intra-institutionally, this control is highly complex given the amalgam of legacy data systems and the numerous and constantly evolving nature of modern data systems that were not necessarily designed to be integrated. The complexity of this concern is augmented when institutions are part of interinstitutional collaborations or networks of public-private partnerships that share data and information. Additionally, institutions that share data as a function of policy and legislative action— particularly formally integrated data and information system infrastructures—may be at higher security risk. This paper will present an intra-institutional paradigm that utilizes and integrates concepts from numerous disciplines to frame a critical and underspecified practical issue in security—controlling for the unintended conversion of data to information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

High-Reliability Systems and the Control of National Security Data and Information

High-reliability systems are characterized by catastrophic implications in the event of failure. These implications can include substantive damage to the environment, social order, and loss of life. Examples of high-reliability systems include nuclear submarines, nuclear reactors, the electric grid, and nuclear weapons. Due to the catastrophic implications of failure, there are heightened awareness and control mechanisms surrounding related data and information. However, defining the difference between data and information is often ambiguous across scholarly disciplines and in United States policy and legislation. For high-reliability systems, the implications of ambiguity between data and information may affect the security of United States interests and even cost lives. For security, data are raw facts or figures without context, while information is the compilation or articulation of data that forms context. Security depends on clarity in the differences between data and information and how to control them. Control is necessary to ensure that data and information are not unintentionally released to foreign governments, the public, or those without need-to-know. A primary concern in the practice of security is the control of data to avoid the unintended conversion to information. Intra-institutionally, this control is highly complex given the amalgam of legacy data systems and the numerous and constantly evolving nature of modern data systems that were not necessarily designed to be integrated. The complexity of this concern is augmented when institutions are part of inter-institutional collaborations or networks of public-private partnerships that share data and information. Additionally, institutions that share data as a function of policy and legislative action—particularly formally integrated data and information system infrastructures—may be at higher security risk. This paper will present an intra-institutional paradigm that utilizes and integrates concepts from numerous disciplines to frame a critical and underspecified practical issue in security—controlling for the unintended conversion of data to information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fundamental benchmarking of the discharge properties of negative electrodes in lead acid batteries

The unprecedented scale of energy storage deployment needed to allow high penetration of intermittent renewable energy sources into the electrical grid places significant economic cost and performance targets on battery technologies. Lead batteries, owing to their highly abundant and inexpensive raw materials, can be considered an important solution to grid storage as long as they achieve high material utilization, fast recharge rates, and long cycle life. To address the limitations in material utilization, we need to revisit the electrochemical processes during the discharge step and answer the following question: what are the fundamental limits of the discharge reaction? In this work we discuss how well-defined lead metal surfaces with nanometer scale roughness allow us to resolve the accessible discharge capacity for both faradaic and non-faradaic processes as a function of electrolyte concentration and in the presence of traditional additives. The direct connection between PbSO 4 layer morphology and discharge rates gives us important insights on the mechanism of discharge as related to the dissolution and passivation events. In conclusion, this work sets the stage for reimagining the design of lead batteries with implications to grid storage applications.

25 ENERGY STORAGE↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Evaluate Distributed Energy Technologies for Cost Savings and Resilience With REopt Lite

NREL's REopt Lite TM web tool evaluates the economics of grid connected photovoltaics (PV), wind, and battery storage at a site. It allows users to identify the system sizes and battery dispatch strategy that minimize a site's life cycle cost of energy, and it estimates the amount of time a PV, wind, battery, and diesel generator system can sustain the site's critical load during a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sustainable Electric Vehicle Batteries for a Sustainable World: Perspectives on Battery Cathodes, Environment, Supply Chain, Manufacturing, Life Cycle, and Policy

Abstract Li‐ion batteries (LIBs) can reduce carbon emissions by powering electric vehicles (EVs) and promoting renewable energy development with grid‐scale energy storage. However, LIB production and electricity generation still heavily rely on fossil fuels at present, resulting in major environmental concerns. Are LIBs as environmentally friendly and sustainable as expected at the current stage? In the past 5 years, a skyrocketing growth of the EV market has been witnessed. LIBs have garnered huge attention from academia, industry, government, non‐governmental organizations, investors, and the general public. Tremendous volumes of LIBs are already implemented in EVs today, with a continuing, exponential growth expected for the years to come. When LIBs reach their end‐of‐life in the next decades, what technologies can be in place to enable second‐life or recycling of batteries? Herein, life cycle assessment studies are examined to evaluate the environmental impact of LIBs, and EVs are compared with internal combustion engine vehicles regarding environmental sustainability. To provide a holistic view of the LIB development, this Perspective provides insights into materials development, manufacturing, recycling, legislation and policy, and beyond. Last but not least, the future development of LIBs and charging infrastructures in light of emerging technologies are envisioned.

36 MATERIALS SCIENCE↗

Comparison of ammonia with methanol, liquefied natural gas and conventional marine transportation fuels through life cycle cost and emissions analysis

This work evaluates ammonia as a potential marine fuel for a SUEZMAX tanker and compares it with methanol, liquefied natural gas, and conventional fuel oils. The motivation arises from the need to identify low-emission, cost-competitive fuel options that can reduce greenhouse gas emissions from international shipping. The central hypothesis is that ammonia produced from renewable energy sources can achieve lower well-to-wake greenhouse gas emissions with varying life cycle costs based on the region. Life cycle assessment and techno-economic analysis were performed for a thirty-year vessel lifetime on two representative trade routes: from Saudi Arabia to Japan and from Saudi Arabia to the Netherlands. Four ammonia production pathways were assessed: natural gas, natural gas with carbon capture, natural gas pyrolysis, and renewable electricity–based synthesis. Results show that wind-based ammonia produced in Saudi Arabia achieved the lowest life cycle well-to-wake greenhouse gas emissions, between 0.58 and 0.64 million metric tons, among all fuels when using regional grid process electricity. With renewable process electricity, ammonia produced from natural gas pyrolysis in Saudi Arabia showed comparable emissions of 0.37 to 0.44 million metric tons with wind-based ammonia of 0.37 to 0.43 million metric tons. Liquefied natural gas exhibited the lowest life cycle cost, between 402 and 412 million United States dollars, and the only negative carbon abatement cost, ranging from −277 to –322 United States dollars per metric ton of greenhouse gas, compared with high sulfur fuel oil. The findings indicate that renewable ammonia offers a promising long-term pathway for reducing shipping emissions, while liquefied natural gas remains the most cost-effective option in the near term.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable layered cathode with suppressed phase transition for long-life sodium-ion batteries

Sodium-ion batteries are among the most promising alternatives to lithium-based technologies for grid and other energy storage applications due to their cost benefits and sustainable resource supply. For the cathode—the component that largely determines the energy density of a sodium-ion battery cell—one major category of materials is P2-type layered oxides. Unfortunately, at high state-of-charge, such materials tend to undergo a phase transition with a very large volume change and consequent structural degradation during long-term cycling. Here we address this issue by introducing vacancies into the transition metal layer of P2-Na$_{0.7}$Fe$_{0.1}$Mn$_{0.75\square}$$_{0.15}$O2 (‘$_{\square}$’ represents a vacancy). The transition metal vacancy serves to suppress migration of neighbouring Na ions and therefore maintain structural and thermal stability in Na-depleted states. Moreover, the specific Na-O-$_{\square}$ configuration triggers a reversible anionic redox reaction and boosts the energy density. As a result, the cathode design here enables pouch cells with energy densities of 170 Wh kg -1 and 120 Wh kg -1 that can operate for over 600 and 1,000 cycles, respectively. In conclusion, our work not only suggests a feasible strategy for cathode design but also confirms the possibility of developing a battery chemistry that features a reduced need for critical raw materials.

25 ENERGY STORAGE↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Light-Duty Vehicle Transportation Policy and Implication on Greenhouse Gas Emissions

The transportation sector accounts for 16% of global greenhouse gas (GHG) emissions and is under formidable pressure to decarbonize. With a growing number of countries making commitments to achieve carbon neutrality or “net-zero” emissions within the next few decades, it is imperative for transportation researchers and policymakers to understand the viable pathways towards achieving carbon neutrality for light-duty transport. This chapter discusses the transportation policies and GHG emissions of the three largest markets in the world—the U.S., China, and the European Union. The life cycle GHG emissions of various vehicle technologies are evaluated while highlighting the regional and temporal differences. We then use market penetration and fleet models, developed specifically for each market, to comprehensively assess the light-duty transport energy demand and GHG emissions under various scenarios. The modeling results show that battery electric vehicles (BEVs) will increase in market share, but internal combustion engine vehicles (ICEV) will continue to dominate the passenger vehicle stock in the next 20 years under most scenarios. Improving ICEV efficiency can play a critical role in meeting GHG regulations in the near- and medium-term. BEVs, whose GHG emissions are highly dependent on the source of electricity generation, will play an essential role in the long-term as the electric grid becomes cleaner. In summary, transportation policies should be technology agnostic and consider emissions based on the whole life cycle. Moreover, a holistic approach to reducing transportation GHG emissions is key to achieving global environmental goals.

Ou, Shawn↗

REopt Lite User Manual

REopt Lite evaluates the economic viability of grid-connected solar photovoltaics, wind, combined heat and power, and electric and thermal storage at commercial and small industrial sites. It allows building owners to identify the system sizes and dispatch strategies that minimize the site’s life cycle cost of energy. REopt Lite also estimates the amount of time on-site generation and storage can sustain the site's critical load during a grid outage and allows the user the choice of optimizing for energy resilience. It is primarily used to inform project development decisions and to support research on the factors that drive project feasibility for market development and policy analysis. It is available through a web interface, application programing interface, and open-source code. This user manual provides an overview of the model, including its capabilities and typical applications; inputs and outputs; economic calculations; technology descriptions; and model parameters, variables, and equations. The model is highly flexible and is continually evolving to meet the needs of each analysis. Therefore, this report is not an exhaustive description of all capabilities, but rather a summary of the core components of the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Home charging for all: Techno-economic and life cycle assessment of multi-unit dwelling electric vehicle charging hubs

Ubiquitous electric vehicle adoption can drastically reduce greenhouse gas emissions (GHG) but will require equitable home charging infrastructure for all residences. Unlike single-family homes, Multi-Unit Dwellings (MUD) currently lack market share and access to nearby charging infrastructure partly due to expensive capital costs for reluctant residential property-owners. Further, this work evaluates the levelized cost of charging (LCOC) for Battery Electric Vehicles (BEVs) at MUD community charging hubs through a techno-economic analysis (TEA) that leverages real-world charging data and costs. Three different MUD charging types are investigated for a baseline and optimistic case: 1.9-kW Level 1 (L1), 6.6-kW Level 2 (L2), and 50-kW Direct Current Fast Charging (DCFC) stations under three different ownership models: resident, utility, and private company. Results demonstrate L1 and L2 chargers to be less expensive than the gasoline equivalent across the United States. Further, utility and private company ownership models, which avoid initial costs for residential property owners, result in a large LCOC premium for L1 and moderate LCOC premium for L2 relative to the resident ownership model. In contrast, DCFC is shown to be expensive for baseline scenarios but economical for optimistic scenarios especially under private company ownership. This work also performs a cradle to grave (C2G) life cycle assessment (LCA) of an average passenger BEV and gasoline conventional vehicle (CV) using yearly (grid mix & vehicle parameters), hourly (grid mix), and state-level (grid mix) resolution. Results show BEVs to have lower GHG emissions (-86% to-10%) than gasoline CVs in the contiguous U.S. Next, the system boundary of the TEA is extended to the total cost of ownership (TCO) of BEVs. The TCO is then coupled with the C2G GHG emissions to calculate the cost of GHG emissions reduction. Ultimately, the cost of GHG emissions reduction from MUD BEVs relative to gasoline CVs is shown to be negative for every scenario except baseline DCFC, meaning MUD BEV charging infrastructure can be a cost-effective endeavor to reduce GHG emissions.

33 ADVANCED PROPULSION SYSTEMS↗